VFD for tower crane

I. Overview
The tower crane is a lifting device with extensive application in construction site. The traditional controlling means usually employ AC wound-type electromotor serial resistance for starting and speed regulating. Because of long-term heavy load operation, frequent positive and negative revolving, the impulse current is rather great. Combing the bad environment of some working fields, the slip ring, carbon brush and contactor of the motor are often damaged. The phenomenon like burnt contact terminal of the contactor, flaming carbon brush, over burning of the motor and resistance usually occur. tower craneIn addition, because of the complicated circuit, the bearing of the swing mechanism has to be exchanged usually. Since the main hoisting mechanism is mainly working on one shaft by two motors, the high-speed motor is still in working status while the low-speed motor is in braking status. They are always in the contradiction of one working and one braking. In addition, the mechanical shock of switching from high speed to low speed is great, the tooth striking phenomenon usually occurs. There was once the case that the product has been positioned and the worker has already hold the mooring rope, tooth striking phenomenon happened in switching from high speed into low speed, then the low-speed motor has brake failure. It is very dangerous. Occasionally, there is also axle breaking phenomenon. The high malfunction rate has big influence to the manufacturing, thus causing high maintenance quantity and cost.
Because the induction motor has incomparable advantages: Simple and solid structure, cheap price, and easy maintenance. So using the means of VFD dragging three-phase induction motor replaces the means of traditional speed regulating, can solve the problem of high failure rate of the tower crane fundamentally. Moreover, it has advanced technology and significant energy saving effect. It is the ideal transmission controlling device of the tower crane.
II. Working principle

  1. Cart operating organization: Drag the whole crane to have "horizontal" movement as the direction of the construction field. It is constituted by a motor, a braking device, a deceleration device and wheels.
  2. Trolley operating organization: Drag the lifting hook to have "vertical" movement as the direction of the crane span structure. It is constituted by a motor, a braking device, a deceleration device and wheels.
  3. Lifting organization: It is used to drag the heavy products to have lifting or descending movements. It is constituted by a motor, a deceleration device, a coiling block and a braking device. The large-scale crane (more than 10 tons) has two lifting organizations: "main hook" and "secondary hook". Normally, the "main hook" and "secondary hook" can't lift products at the same time.
  4. Swing mechanism: Drag the bridge arm to conduct revolving movement with the shaft as the center. For preventing from line deflection, it is mainly constituted by double motors, a deceleration mechanism and a braking device.

III. Technical requirement of VFD control tower crane

  1. The safe and reliable operation of the tower crane
  2. Can realize forward and reverse revolving, multi-stage speed operation, external reset of the frequency conversion malfunction, emergent stop of the frequency conversion malfunction to ensure safety.
  3. Frequency conversion starting, stopping and malfunction, ensure the effective movement of the mechanical brake and the safe operation of the device.

IV. Debugging parameters of ATO VFD for tower crane

Function codeNameSet value of main hookRemark (use main hook only)
P0.00Selection of the frequency setting channel5Multi-stage speed operation setting
P0.02Selection of the operating command channel1Terminal command
P0.04Control mode0Without PG vector control
P0.10Acceleration time 11.5Unit (s)
P0.11Deceleration time 12Unit (s)
P0.15Torque rising10Unit (%)
P2.01Starting frequency3Unit (Hz)
P3.08Multistage speed10

Unit (%), set according to customer requirements

P3.09Multistage speed 140
P3.11Multistage speed 360
P3.15Multistage speed 780
P4.34Multistage speed 1450Unit (Hz)
P6.00Functional selection of terminal X11Forward revolving operation
P6.01Functional selection of terminal X22Reverse revolving operation
P6.02Functional selection of terminal X37Fault reset
P6.03Functional selection of terminal X412Multi-stage speed 1
P6.04Functional selection of terminal X513Multi-stage speed 2
P6.05Functional selection of terminal X614Multi-stage speed 3
P6.06Functional selection of terminal X725Multi-stage speed 4
P6.12Output selection of the relay (RA RB RC)4Frequency level detection FDT output
P6.13Output selection of the relay (RA RB RC)3Fault output
P6.19Frequency detection value (FDT electrical level)4Unit (Hz), set according to the field condition (for reference only)
P8.00Self-learning of the motor paramete2Set according to the field condition
P8.01Motor power15
P8.02Rated revolving speed of the motor0.6
P8.03Rated current of the motor40

Buying an ATO VFD for tower crane speed control now, 10 hp VFD, 25 hp VFD, 50 hp VFD...