VFD for wire-cut EDM

I. Overview
The wire-cut EDM is to utilize the metal linear tool electrode (or named as wire electrode) to process workpieces with the principle of impulsive discharge to erode the metals. High speed wire-cut EDM is applied in the processing of the metal pieces with high precision, complicated shape, especially the mould and so on.
II. The contrast before and after using the VFD
The electrical and motor control parts of the wire-cut EDM. The wire bucket motor control part controls the motor and the wire bucket, drives the molybdenum wire to have fast negative and positive starting operation and stopping. In addition, it will provide the corresponding protective functions. The electrical control of other types of the machinery tools usually employs the relay control mode, which is also practical. However, such control mean has the following a series of problems:

  1. The contactor of the relay has frequent movement and relatively high consumption. The intermediate conversion is complicated and the possibility of having problems is high.
  2. The frequent positive and negative full-pressure starting of the motor has big starting current and big shock to the mechanical part of the wire bucket.
  3. The frequent close and disconnection of the touch spot of the contactor, thus causing great noise.

The main consequence resulted by such problems is the declining of the entire processing reliability, increasing of the wire burning and other problems. Therefore, it is sure to generate a second processing, thus affecting the product quality and generating unnecessary economic loss finally. Aimed at the above existing problems, the VFD with small power has been used to improve the original control mode. The reason mainly includes the following several points:

  1. The frequency conversion products have matured technology and reliable performance. They have been widely used in the control systems of the induction motor widely.
  2. Utilizing the circumscribed control input terminal, output terminal which reflects the operating status and the powerful programmable function of the VFD, flexible selections and settings can be conducted according to the different control objects and control means, thus saving the complicated switching control in the middle.
  3. The starting and stopping time as well as the current of the motor can be completed through manual coding and automatic setting, which has reduced the disadvantages of the original mean with big starting current and mechanical shock.
  4. The phase sequence switch of the main circuit is completed through the internal integrated control circuit in the VFD (no touch point switchover). In addition, there is also DC braking function in the VFD. And it has been set that when the revolving speed of the motor becomes 0, the braking process can be eliminated automatically, thus avoiding the unnecessary big current sustained by the motor caused by improper operation.
    wire-cut EDM

III. The parameter setting of ATO VFD is as follows:

Function codeNameSetting rangeSet value
P0.02Unilateral cutting reverse speedP0.19 lower limiting frequency~P0.20 upper limiting frequency50.00Hz
P3.00Mean of the processing finishes0: Immediate deceleration + DC braking stop
1: Left entering of positive revolving signal valid stop
2: Right entering of negative revolving signal valid stop
0
P3.02Operating mode0: Switch inverting, 1: Timely inverting, 2: Unilateral cutting0
P3.03Effective polarity of processing finishes0: Normal open, 1: Normal closed1
P3.11Reversing delay time0s~5.0s0.1
P0.17Acceleration time 10.1~6000.00.5
P0.18Deceleration time 10.1~6000.00.5
P3.14Acceleration time 20.1~6000.00.5
P3.15Deceleration time 20.1~6000.00.5
P3.16Acceleration time 30.1~6000.00.5
P3.17Deceleration time 30.1~6000.00.5
P3.18Acceleration time 40.1~6000.00.5
P3.19Deceleration time 40.1~6000.00.5
P3.20Acceleration time 50.1~6000.00.5
P3.21Deceleration time 50.1~6000.00.5
P3.22Acceleration time 60.1~6000.00.5
P3.23Deceleration time 60.1~6000.00.5
P3.24Acceleration time 70.1~6000.00.5
P3.25Deceleration time 70.1~6000.00.5
P3.26Multistage frequency 1P0.19 lower limiting frequency~P0.20 upper limiting frequency50.00Hz
P3.27Multistage frequency 2P0.19 lower limiting frequency~P0.20 upper limiting frequency40.00Hz
P3.28Multistage frequency 3P0.19 lower limiting frequency~P0.20 upper limiting frequency30.00Hz
P3.29Multistage frequency 4P0.19 lower limiting frequency~P0.20 upper limiting frequency25.00Hz
P3.30Multistage frequency 5P0.19 lower limiting frequency~P0.20 upper limiting frequency20.00Hz
P3.31Multistage frequency 6P0.19 lower limiting frequency~P0.20 upper limiting frequency15.00Hz
P3.32Multistage frequency 7P0.19 lower limiting frequency~P0.20 upper limiting frequency10.00Hz
P3.33Keyboard setting speed 1P0.19 lower limiting frequency~P0.20 upper limiting frequency5.00Hz
P3.34Keyboard setting speed 2P0.19 lower limiting frequency~P0.20 upper limiting frequency10.00Hz
P3.35Keyboard setting speed 3P0.19 lower limiting frequency~P0.20 upper limiting frequency20.00Hz
P3.36Keyboard speed set value1: P3.33, 2: P3.34, 3: P3.351
P4.05Multistage speed control terminal 110.00Hz
P4.06Multistage speed control terminal 220.00Hz
P4.07Multistage speed control terminal 330.00Hz
P8.00Simple PLC operating mode0113
P8.01Stage 1 setting000
P8.02Stage 1 time setting3
P8.03Stage 2 setting010
P8.04Stage 2 time setting5
P8.06Stage 3 time setting3
P8.08Stage 4 time setting5
P8.10Stage 5 time setting0
P8.12Stage 6 time setting0
P8.14Stage 7 time setting0