VFD for ball mill

I. Overview
For a long period, the chemical, cement, ceramic industries and so on normally adopt the ball mill to grind the raw materials. Usually, the decompression start-up mode is employed. The high starting current has great shocks to the equipment and power grid. Meanwhile, in working frequency, it is easily to over grid the materials. The required grinding circle is long, with low grinding efficiency and high unit product consumption. This promotes people to study and develop the ball mill system with smooth start, high grinding efficiency, high output and low consumption. This is exactly the VFD control system.
II. Working principle of the ball mill
The ball mill is mainly constituted by cylindrical barrel, end cap, bearing and transmission big gear ring and other components. The ore grinding operation is conducted in the tubular structure of the ball mill. When the grinding medium in the barrel is lifted to a certain height as the barrel revolves, the medium will fall because of gravity. The ore in the barrel will suffer from violent shocks of the medium. On the other hand, because the grinding medium revolves and rotates along the axis in the barrel, the extrusion machine and grinding force will be generated between the mediums and in the contact area between the medium and the barrel, so as to grind the ore.
working principle of ball mill
III. The advantages of improved ball mill

  1. The VFD start is the soft start, which has avoided the start-up impulse current in the working frequency. Meanwhile, it will protect the equipment.
  2. It can operate as the set multi-stage PLC which is set automatically. The operation mode of multi-stage speed can reduce the input current in the status of lower than the working frequency. Under the conditions of satisfying the technological requirements of the equipment, different operating frequency and operating time are set at different time periods, thus having a good energy-save effect. The electricity saving rate can usually reach 7-18%. In addition, it has the halt memory function and elimination memory function.
  3. The rich protective functions of VFD, such as overflow, overvoltage, overload, phase loss, overheat and so on reduce the breakdown rate of the equipment.
  4. After entering into the grinding stage of the later period, the operating speed of the motor has reduced. The noise sent by the ball mill has been reduced greatly than the time period in the full-speed operation in working frequency, thus improving the working environment of the operators. It is beneficial for environmental protection and the health of the employees.

IV. Basic parameter setting of ATO VFD

Function codeNameSet valueRemark
P0.03Operating command channel1Terminal operation
P0.09Torque rising3.0Set the torque properly
P0.17Acceleration time50Set according to the field condition
P0.18Deceleration time50
P3.26Multistage frequency 148Set according to technological requirement
P3.27Multistage frequency 245
P3.28Multistage frequency 342
P3.29Multistage frequency 446
P2.05Halt mode1Free halt
P8.00

Selection of the simple PLC operating mode1111

The stage and frequency in storage power off
Continue to operate from the stage frequency in breakoff moment
Halt after single cycle, time unit: minute
P8.01Stage 1 setting0 0 0set according to the technological requirement
P8.02Stage 1 operating time130
P8.03Stage 2 setting0 0 0
P8.04Stage 2 operating time280
P8.05Stage 3 setting0 0 0
P8.06Stage 3 operating time250
P8.07Stage 4 setting0 0 0
P8.08Stage 4 operating time260
P4.01Function selection of the input terminal X217External reset input
P5.09Malfunction automatic recovery times10Times

Note: The parameters in the unused multi-stage speed, simple PLC stage are all set to be zero.

Buying an ATO VFD for ball mill improvement now, 30 hp VFD, 125 hp VFD, 300 hp VFD...