Sliding Vane Pump Price List

A 380V sliding vane pump in the 2–10 HP range costs $4,205–$7,942. Each HP tier adds approximately $900–$1,100, driven by motor frame size, body material, and flow capacity.

This pump series, provided by ATO Industrial Automation, is commonly used in fuel transfer, chemical processing, and industrial fluid handling systems.

Price range$4,205 – $7,942
Power range2 HP (1.5 kW) – 10 HP (7.5 kW)
Voltage380V three-phase
Working pressure0.4 MPa (all models)
Self-priming heightUp to 6.5 m (all models)
Max flow rateUp to 40 m³/h (10 HP model)
Operating temperature−10 °C to +80 °C
Viscosity limitUp to ~500 cSt
Pump typeRotary positive displacement (also: rotary vane pump)

Key Takeaways

  • Price range: $4,205 (2 HP) to $7,942 (10 HP), 380V three-phase
  • Best fluid range: up to 500 cSt — diesel, kerosene, light oils, solvents
  • Self-priming: up to 6.5 m vertical lift — no flooded suction required
  • Road-mobile applications: specify ATO-SVP-075 — the only ductile iron model in the series
  • Maximum throughput: ATO-SVP-10 delivers up to 40 m³/h at 960 r/min
  • Do not use for: fluids above 2,000 cSt, abrasive solids, or Zone 1/2 hazardous areas without explosion-proof motor certification
  • Sizing rule: select the smallest HP that covers required flow rate plus 15–20% margin

Contents:

What Is a Sliding Vane Pump?

A sliding vane pump is a positive displacement pump that delivers constant, metered flow regardless of discharge pressure variation, using spring-loaded vanes to form sealed chambers inside an eccentric rotor-casing assembly.

How it works:

  1. Spring-loaded vanes slide radially in and out of a slotted rotor mounted eccentrically inside a cylindrical casing
  2. As the rotor turns, vanes maintain contact with the casing wall, forming chambers that expand at the inlet (drawing in fluid) and compress at the outlet (discharging)
  3. Flow output is proportional to rotor speed — not affected by downstream pressure changes

Comparison: Sliding vane pumps provide more consistent flow than centrifugal pumps under variable back-pressure, and self-prime from below-grade tanks where centrifugal designs require flooded suction.

FeatureSliding vane pumpCentrifugal pump
Flow under back-pressure changeConstantDrops as pressure increases
Self-primingUp to 6.5 mRequires flooded suction
Viscosity handlingUp to ~500 cStBest for thin, low-viscosity fluids
Typical useFuel transfer, chemical dosing, marine bunkeringHigh-volume water, HVAC, general process

When to use — and when not to:

ConditionSuitable?
Fluid viscosity < 500 cSt✓ Yes — full rated performance
Fluid viscosity 500–2,000 cSt⚠ Conditional — consult ATO derating data
Fluid viscosity > 2,000 cSt✗ No — use a gear pump
Suction lift ≥ 3 m from below-grade tank✓ Yes — self-primes to 6.5 m
Abrasive or particle-laden fluid✗ No — accelerates vane and stator wear
Hazardous area Zone 1 / Zone 2⚠ Only with explosion-proof motor certification

Pro Tip: "Sliding vane pump" and "rotary vane pump" refer to the same device. "Sliding vane pump" is standard in North American catalogs; "rotary vane pump" is more common in European and marine documentation.

Price List by Model

All five models share: 380V three-phase · 0.4 MPa working pressure · mechanical seal · self-priming to 6.5 m.

ModelPowerBody materialPrice (USD)SKU
2 HP Sliding Vane Pump2 HP / 1.5 kWCast iron$4,205.56ATO-SVP-02
4 HP Sliding Vane Pump4 HP / 3 kWCast iron$5,310.32ATO-SVP-04
5.5 HP Sliding Vane Pump5.5 HP / 4 kWCast iron$6,159.13ATO-SVP-055
7.5 HP Sliding Vane Pump7.5 HP / 5.5 kWDuctile iron$6,899.60ATO-SVP-075
10 HP Sliding Vane Pump10 HP / 7.5 kWCast iron$7,942.86ATO-SVP-10

ATO-SVP-02 · 2 HP · $4,205.56

Cast iron body, mechanical seal, fixed installation only — not rated for road-mobile or high-vibration mounting.

Specify when: low flow demand, fixed indoor installation, unit cost is the primary constraint.

ATO-SVP-04 · 4 HP · $5,310.32

Self-priming to 6.5 m covers the majority of below-grade fuel tank configurations without auxiliary priming equipment. High-efficiency vane geometry reduces energy consumption at this power level.

Specify when: suction lift 3–5 m, moderate throughput, fixed installation at fuel retail or depot sites.

ATO-SVP-055 · 5.5 HP · $6,159.13

Operates at 960 r/min — below typical pump speeds — reducing vane tip contact velocity and extending service intervals in continuous-duty environments. Suited to variable-viscosity batch transfer where consistent output pressure matters more than peak flow.

Specify when: continuous 24/7 process transfer, variable-viscosity batches, low unplanned maintenance frequency required.

ATO-SVP-075 · 7.5 HP · $6,899.60

The only ductile iron model in this series. Ductile iron tensile strength is approximately 414 MPa versus 180 MPa for gray cast iron. Road-mobile tank trucks subject pump bodies to simultaneous road vibration and repeated pressure cycling — a combined load that causes fatigue cracking in cast iron bodies within 18–24 months of field use. Ductile iron eliminates this failure mode.

Specify when: road-mobile installation, oil tank truck, or any application with mechanical shock or sustained pressure cycling.

ATO-SVP-10 · 10 HP · $7,942.86

Highest flow in the series: up to 40 m³/h at 960 r/min. For marine bunkering and port fuel operations, transfer throughput per hour directly determines vessel turnaround time per berth. Specify over the 7.5 HP when throughput — not viscosity or lift — is the binding operational constraint.

Specify when: marine bunkering, high-volume port or depot operations, refinery pipeline circulation.

How to Choose the Right Sliding Vane Pump?

Step 1 — Calculate required flow rate

Required flow rate (m3/h) = total volume ÷ available hours × 1.15–1.20 (margin factor).

  • Add 15–20% margin for suction line losses and efficiency variance
  • Select the smallest HP model whose rated flow exceeds this figure
  • Over-specifying HP adds $900–$1,100 per tier with no operational benefit if peak flow is already covered

Step 2 — Assess suction conditions

All models self-prime to 6.5 m vertical lift. Effective lift is reduced by:

  • Suction pipe ID smaller than pump inlet port — never reduce pipe diameter at any point
  • Each 3 m of horizontal suction run adds approximately 0.3–0.5 m of effective lift loss
  • Each foot valve or elbow fitting adds resistance — minimise the number of fittings

Step 3 — Check fluid viscosity

  • Up to ~500 cSt: all models perform within specification
  • 500–2,000 cSt: flow rate will decrease; consult ATO for derating curves
  • Above 2,000 cSt: sliding vane pump not recommended — use a gear pump

Step 4 — Confirm installation type

InstallationRecommendedReason
Fixed (indoor/depot)ATO-SVP-02 to ATO-SVP-055Cast iron adequate for static mounting
Road-mobile (tank truck)ATO-SVP-075 (ductile iron)Ductile iron resists road vibration and fatigue cracking
Marine / portATO-SVP-10Highest throughput in the series
Hazardous areaContact ATOExplosion-proof motor certification required

Application Guide by Use Case

The following guide shows typical model selection based on different application scenarios and operating conditions.

Underground Fuel Tank Unloading · ATO-SVP-04 ($5,310)

Underground storage tanks at retail fuel sites typically sit 3–5 m below grade. The 4 HP self-prime height covers this range without auxiliary priming equipment.

  • Suction line must run continuously uphill — no air-trapping high points
  • Fit a foot valve at the tank pickup to hold prime between operations
  • Suitable for: underground diesel storage, fuel retail stations, small fuel distribution depots

Oil Tank Truck Loading and Unloading · ATO-SVP-075 ($6,899)

Road-mobile pumps face three concurrent stresses absent in fixed installations: highway vibration, pressure spikes at each delivery stop, and temperature cycling between ambient and warmed fluid. Cast iron develops fatigue micro-cracks under this combination within 18–24 months. Ductile iron (414 MPa tensile strength) does not.

  • Verify seal elastomer before ordering — NBR is not suitable for E10 or higher ethanol-blended fuels
  • Specify PTFE or FKM (Viton) for E10–E85 grades
  • Suitable for: oil tank trucks, mobile diesel transfer units, fuel delivery fleets

Typical applications:

  • Oil tank trucks
  • Mobile diesel transfer units
  • Fuel delivery fleets
  • Road-based fuel transportation systems

Petroleum and Chemical Process Transfer · ATO-SVP-055 ($6,159)

Process lines transferring multiple products on a batch schedule require consistent displacement output across varying viscosities. At 960 r/min, the 5.5 HP model reduces internal wear rate in 24/7 environments compared to higher-speed alternatives, lowering unplanned maintenance frequency.

  • Stable output pressure across viscosity variation within a batch cycle
  • Lower vane tip contact velocity extends service intervals
  • Suitable for: petroleum refinery transfer lines, chemical batch processing, solvent handling systems

Typical applications:

  • Petroleum processing systems
  • Chemical transfer pipelines
  • Solvent handling systems
  • Continuous circulation processes

Marine Bunkering and Port Fuel Transfer · ATO-SVP-10 ($7,942)

At up to 40 m³/h, this is the standard specification for shore-to-ship and ship-to-ship fuel transfer at commercial ports. Transfer throughput per hour directly determines vessel turnaround time per berth.

  • Verify seal compatibility with marine fuel grades before installation — IFO 180, MGO, and VLSFO viscosity ranges widely with temperature
  • Specify over the 7.5 HP when throughput, not viscosity or lift, is the binding constraint
  • Suitable for: ship-to-shore transfer, marine bunkering terminals, large petroleum storage facilities

Typical applications:

  • Ship-to-shore fuel transfer
  • Marine bunkering systems
  • Port fuel distribution stations
  • Large petroleum storage facilities

Light Chemical and Small-Scale Fuel Transfer · ATO-SVP-02 ($4,205)

For low-flow applications where cast iron body is adequate and minimising unit cost is the priority.

  • Suitable for: chemical dosing lines, small above-ground diesel storage, low-capacity industrial transfer
  • Not rated for road-mobile or high-vibration environments

Sliding vane pump used for chemical and petroleum transfer

Sliding Vane Pump vs. Gear Pump

Rule: Use a sliding vane pump for low-to-medium viscosity fuels and chemicals requiring self-priming or temperature-stable transfer. Use a gear pump for fluids above 500 cSt or when upfront cost dominates at small scale.

ScenarioBetter choiceReason
Low-viscosity fuel < 10 cSt (diesel, kerosene)Sliding vane pumpLower heat generation; flow stable under back-pressure variation
High-viscosity fluid > 500 cSt (heavy oil, asphalt)Gear pumpMaintains rated flow; vane performance degrades above 500 cSt
Below-grade tank, suction lift ≥ 3 mSliding vane pumpSelf-primes to 6.5 m; gear pump requires flooded suction
Volatile / low-flash-point chemicalsSliding vane pumpLower internal friction = more stable fluid temperature
Precise metering, low flow rateEitherBoth deliver smooth positive displacement output
Small scale < 2 HP, budget priorityGear pumpComparable gear pumps often available at lower upfront cost
Road-mobile / tank truckSliding vane pumpDuctile iron body option (SVP-075) — rare in gear pump range

Frequently Asked Questions

Find quick answers to the most common questions about sliding vane pump pricing, operation, and applications.

Q1: What affects sliding vane pump price?

A: Sliding vane pump price is mainly affected by motor power (HP), flow rate, material construction, sealing method, and application requirements. Higher-power models generally provide greater transfer capacity and may include heavier-duty construction for fuel, chemical, or marine applications.

Q2: Can a sliding vane pump run dry?

A: Sliding vane pumps are generally not designed for dry running because the pumped liquid helps lubricate and cool internal components. Running dry for extended periods may increase wear on vanes and internal surfaces, potentially reducing service life.

Q3: What liquids are suitable for a sliding vane pump?

A: Sliding vane pumps are commonly used for diesel, gasoline, kerosene, solvents, light oils, lubricants, and some industrial chemicals. They are generally more suitable for low to medium viscosity liquids rather than highly viscous fluids.

Q4: What is the difference between a sliding vane pump and a centrifugal pump?

A: A sliding vane pump is a positive displacement pump, meaning flow output remains relatively stable under changing pressure conditions. A centrifugal pump relies on velocity and is often better suited for high-flow, low-viscosity liquid transfer where precise flow consistency is less critical.

Leave your comment
*
Only registered users can leave comments.
Blog archive