When selecting a output line reactor, its function shall be firstly determined, then the reactance ratio can be selected according to its functions, finally, the output line reactor capacity is selected according to the capacitor capacity (reactor capacity is equal to the capacitor capacity multiplied by reactance ratio). Selection of a reactor is complex, power grid quality and parameters, capacitor parameters shall be determined.
2018, November
ATO sells VFD's power range from 1/2hp to 300hp, include single phase input and output VFDs from 1/2hp to 7.5hp, 110v/120v input VFDs from 1hp to 7.5hp, single phase input to three phase output VFDs from 1/2hp to 10hp, three phase input/output VFDs from 1hp to 300hp. All VFDs are manufacturer direct sale and quality guaranteed. Widely used in fans, pumps, lathes, cable machinery, printing and dyeing equipment, chemical machinery, plastic machinery, etc. The following are ATO variable frequency drive price lists for your reference. If you want more information, please go to ATO VFD products page.
Solid state relay (SSR) is a non-contact switch which drives a high-current load with a small control signal. The solid state relay consists of three parts, namely, the input circuit, the isolation (coupling) and the output circuit.Compared with the electromagnetic relays, solid state relays are characterized with high reliability, no contact, no spark, no noise, strong anti-interference ability, long lifetime, and fast switching speed. Now SSR are widely used in automation equipment, CNC machines, remote control system, instrumentation, medical equipment and so on.
Measurement method of a safety relay's DC resistance with a digital multiemter is similar to that with a pointer multimeter. According to the nominal DC resistance of safety relay, place the multimeter in an appropriate resistor and connect two test pens to the leading wire of the relay coil, then measure the resistance. Comparing the measurement result with the nominal resistance, if the error is within ±l0%, it's normal. If the resistance is obviously smaller, partial short-circuit fault exists in the coil; If the resistance is zero, the coil is short circuited; If the multiemter shows "1", the coil breaks.
A device that converts alternating current with constant voltage and frequency into alternating current with variable voltage or frequency is called "variable frequency drive". VFD has the functions of voltage regulation, frequency modulation, voltage stabilization, speed regulation etc. VFD is generally used to control 3 phase AC motor in variable speeds. Now the three phase 220v-240v motor can run on single phase 120v power supply. ATO offers you 110v/120v input, 220v/230v/240v output VFDs. It can not only realize single phase input & output, but also convert single phase to three phase.
Safety relay has special color, generally yellow. Current safety relay acts reliably and flexibly, it's mainly used to control the power supply circuit. When an emergency occurs, the circuit controlled by the safety relay is disconnected by pressing the emergency stop switch, thus ensuring safety.