40 hp (30 kW) Soft starter, 60 A, 3ph 220v/380v/480v

$449.20
Cheap price 40 hp soft starter for sale, 30 kW three phase 220v, 380v, 480v AC motor soft starter for choice, make motor in soft start & soft stop, buy from manufacturer directly.
SKU: GS-030
Free Shipping
Delivery date: 6-12 days

40 hp soft starter, 30 kW three phase 220v, 380v, 480v, 690v AC motor starter, manufacturer direct sale.

ModelGS2-030 (220v, 240v), GS3-030 (380v, 400v, 415v), GS4-030 (460v, 480v), GS6-030 (575v, 690v).
Capacity40 hp (30 kw)
Current60 amps at 380v/480v, 110 amps at 220v, 37 amps at 690v
Weight5 kgs
Dimension270*146*160 mm
InputVoltageThree-phase 240v, 420v, 480v, 660v AC
Frequency50Hz/ 60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.
485 CommunicationDB9 interface, male plug, ① is RS485+, ⑥ is RS485-
Control Mode
  1. Operation panel control.
  2. Operation panel + external control.
  3. External control.
  4. External control + COM control.
  5. Operation panel + external + COM control.
  6. Operation panel + COM control.
  7. COM control.
  8. No start or stop operation.
Start Mode
  1. Current-limiting to start.
  2. Voltage ramp to start.
  3. Torque control + current-limiting to start.
  4. Torque control + voltage ramp to start.
  5. Current ramp to start.
  6. Voltage current-limiting double closed-loop start.
Stop Mode
  1. Soft stop.
  2. Free stop.
Protective Function
  1. Open loop protection for external instantaneous stop terminals.
  2. Over-heat protection for soft starter.
  3. Protection for too long starting time.
  4. Input open phase protection.
  5. Output open phase protection.
  6. Unbalanced three-phase protection.
  7. Starting over current protection.
  8. Running overload protection.
  9. Under voltage protection for power voltage.
  10. Overvoltage protection for power voltage.
  11. Protection for fault parameter setting of the soft starter.
  12. Load short circuit protection.
  13. Auto restart or incorrect wiring protection.
  14. Incorrect wiring protection of external control stop terminals.
AmbientPlace to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
AltitudeBelow 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
Temperature-30 +55 oC
Humidity90%RH without dew condensation.
Vibration<0.5G
StructureEnclosureIP 20
CoolingNatural wind cooling.

Details

30KW Soft Starters Details

Tips: Soft starter principle
Soft-start is a motor starting mode. Compared to the hard start, in the motor soft-start process the voltage gradually increases to the rated voltage, the starting current gradually goes up to the rated current and then goes down. Soft-start makes the motor speed gradually increasing, and there is no impact torque phenomenon, motors always running smoothly and have no damage. The soft-start of the motor is achieved by a soft starter, which places the voltage regulator (typically a three-phase anti-parallel thyristor) between the power supply and the stator of the motor. The circuit is like a three-phase fully-controlled bridge rectifier circuit.
When the output voltage increases to the rated voltage, to achieve a smooth start, and gradually reduce the starting current, in order to avoid the motor trip phenomenon caused by too large starting current. When the speed increases to the rated speed, the motor's soft-start process ends, the soft starter automatically uses the bypass contactor to replace the thyristor to provide the voltage, making the motor has been rotating at constant speed invariably.
The soft starter not only can complete the motor soft-start, but also can complete the motor soft-stop. Soft starter soft-stop working principle is exactly opposite to soft-start working principle. It is mainly reducing output voltage gradually to reduce its speed until zero, and up to the motor stopping slowly.

Soft Starter Works with a Bypass Contactor

Soft starter works with a bypass contactor saving energy by eliminating thyristor losses during the run. The bypass contactor shunts the current flowing through the soft starter switch circuit to reduce heat accumulation in the soft starter power electronics during motor operation. This provides maximum efficiency and prolongs the life of soft-start switching components because they only work during the start and stop cycles of the motor.

How to Change the Soft Starter Rated Current

Delayed Soft Start of A Motor

In this video, we introduce how to use a soft starter together with a bypass contactor to achieve a delayed soft start of a motor.

Product reviews
Can we modify the order?
5
Igoclick
Avatar
1/19/2022 1:23 AM
Yesterday, we ordered a 25 hp (18 kW) soft starter for 220V input voltage. Can we modify the order to be 208V? What is the price?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we modified the order and no payment is required, free of charge.
We have some issues
5
Hygge
Avatar
8/28/2024 2:10 AM
We have had issues where if it lost incoming power but was being called to run it would trip and there was no way to auto restart that. We had to push the reset button on the unit.  The power is so bad here I see that causing a lot of manual restarts.
Will the soft start auto-rest or rest itself? Is there any way for our soft starter to restart automatically after the power supply recovery?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our soft starter does Not have this function. But you can achieve restart automatically after the power supply through external control terminals. For example, use external relay contacts to control the pneumatic/stop soft starter of the soft start.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

40 hp soft starter, 30 kW three phase 220v, 380v, 480v, 690v AC motor starter, manufacturer direct sale.

ModelGS2-030 (220v, 240v), GS3-030 (380v, 400v, 415v), GS4-030 (460v, 480v), GS6-030 (575v, 690v).
Capacity40 hp (30 kw)
Current60 amps at 380v/480v, 110 amps at 220v, 37 amps at 690v
Weight5 kgs
Dimension270*146*160 mm
InputVoltageThree-phase 240v, 420v, 480v, 660v AC
Frequency50Hz/ 60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.
485 CommunicationDB9 interface, male plug, ① is RS485+, ⑥ is RS485-
Control Mode
  1. Operation panel control.
  2. Operation panel + external control.
  3. External control.
  4. External control + COM control.
  5. Operation panel + external + COM control.
  6. Operation panel + COM control.
  7. COM control.
  8. No start or stop operation.
Start Mode
  1. Current-limiting to start.
  2. Voltage ramp to start.
  3. Torque control + current-limiting to start.
  4. Torque control + voltage ramp to start.
  5. Current ramp to start.
  6. Voltage current-limiting double closed-loop start.
Stop Mode
  1. Soft stop.
  2. Free stop.
Protective Function
  1. Open loop protection for external instantaneous stop terminals.
  2. Over-heat protection for soft starter.
  3. Protection for too long starting time.
  4. Input open phase protection.
  5. Output open phase protection.
  6. Unbalanced three-phase protection.
  7. Starting over current protection.
  8. Running overload protection.
  9. Under voltage protection for power voltage.
  10. Overvoltage protection for power voltage.
  11. Protection for fault parameter setting of the soft starter.
  12. Load short circuit protection.
  13. Auto restart or incorrect wiring protection.
  14. Incorrect wiring protection of external control stop terminals.
AmbientPlace to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
AltitudeBelow 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
Temperature-30 +55 oC
Humidity90%RH without dew condensation.
Vibration<0.5G
StructureEnclosureIP 20
CoolingNatural wind cooling.

Details

30KW Soft Starters Details

Tips: Soft starter principle
Soft-start is a motor starting mode. Compared to the hard start, in the motor soft-start process the voltage gradually increases to the rated voltage, the starting current gradually goes up to the rated current and then goes down. Soft-start makes the motor speed gradually increasing, and there is no impact torque phenomenon, motors always running smoothly and have no damage. The soft-start of the motor is achieved by a soft starter, which places the voltage regulator (typically a three-phase anti-parallel thyristor) between the power supply and the stator of the motor. The circuit is like a three-phase fully-controlled bridge rectifier circuit.
When the output voltage increases to the rated voltage, to achieve a smooth start, and gradually reduce the starting current, in order to avoid the motor trip phenomenon caused by too large starting current. When the speed increases to the rated speed, the motor's soft-start process ends, the soft starter automatically uses the bypass contactor to replace the thyristor to provide the voltage, making the motor has been rotating at constant speed invariably.
The soft starter not only can complete the motor soft-start, but also can complete the motor soft-stop. Soft starter soft-stop working principle is exactly opposite to soft-start working principle. It is mainly reducing output voltage gradually to reduce its speed until zero, and up to the motor stopping slowly.

Product reviews
Can we modify the order?
5
Igoclick
Avatar
1/19/2022 1:23 AM
Yesterday, we ordered a 25 hp (18 kW) soft starter for 220V input voltage. Can we modify the order to be 208V? What is the price?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we modified the order and no payment is required, free of charge.
We have some issues
5
Hygge
Avatar
8/28/2024 2:10 AM
We have had issues where if it lost incoming power but was being called to run it would trip and there was no way to auto restart that. We had to push the reset button on the unit.  The power is so bad here I see that causing a lot of manual restarts.
Will the soft start auto-rest or rest itself? Is there any way for our soft starter to restart automatically after the power supply recovery?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our soft starter does Not have this function. But you can achieve restart automatically after the power supply through external control terminals. For example, use external relay contacts to control the pneumatic/stop soft starter of the soft start.
Only registered users can write reviews
Customers who bought this item also bought

200 hp (160 kW) VFD, 3 Phase 240V, 420V, 480V

GK3000-4T1600G
$6,979.36
Favorable price 200 hp (160 kW) VFD for electric motor speed controls, 3 phase 240V, 420V, 480V is optional, brand new variable frequency drive sale by manufacturer directly.

15 hp (11 kW) Soft starter, 22A, 3ph 240v/400v/480v

GS-011
$367.93
Low cost 15 hp soft starter, 11 kW three phase 240v, 400v, 480v AC motor soft starter, protecting AC motor from over-voltage, over-current and phase unbalance etc.

25 hp (18 kW) Soft starter, 37 A, 3ph 220v/400v/460v

GS-018
$415.92
25 hp soft starter, 18 kW (18.5 kW) three phase 220v, 400v, 460v AC motor soft starter direct sale by manufacturer, control motor in soft start & soft stop.

10 kVA Isolation Transformer, 3 phase, 400 Volt to 240 Volt

ATO-T-SG10KVA
$2,635.71
Safety 10 kVA isolation transformer is suitable for circuit of 50 or 60Hz, 3 phase, primary voltage 400V to secondary voltage 240V. The transformers is high quality with lower cost, manufactured direct sale and fully compliant with reduced low voltage regulations.

10 hp (7.5 kW) Soft starter, 15 A, 3ph 220v/400v/480v

GS-7d5
$352.31
Favorable price 10 hp soft starter, 7.5 kW 3 phase 220v, 400v, 480v electric motor soft starts, make motor in soft start & soft stop, direct sale from manufacturer.