10 kVA Isolation Transformer Specifications

BasicsModelATO-SG10KVA
Phase3 phase
Capacity10 kVA
Weight of Aluminium Wire TransformerOpen type: 75kg
Protected type: 96kg
Weight of Copper Wire TransformerOpen type: 78kg
Protected type: 98kg
Technical ParametersPrimary Voltage400V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage240V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

3-phase isolation transformer details

10 kVA Isolation Transformer Installation Dimension

3 phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=380*240*380mmOpen type: a*b*c=380*240*380mm
Mouting size: d*e=260*150mmMouting size: d*e=260*150mm
Protected type: A*B*C=380*530*560mmProtected type: A*B*C=380*530*560mm

Tips: What is a 10 kVA isolation transformer?

10 kVA isolation transformer is a step up & step down 3 phase isolation transformer whose input windings and output windings have electrical isolation, it can avoid accidentally contact with the charged body at the same time. The transformer can isolate the respective current of primary and secondary windings. Its principle is the same with ordinary dry-type transformer, also use electromagnetic induction principle to isolate primary power circuit and secondary circuit ground floating to ensure electrical safety. ATO isolation transformers are widely used for control power of general circuit, power of safety lighting and indicator light in the electronics industry, mining enterprises and machine equipment.

How to Test Step Up & Step Down Isolation Transformer?

Need more detail of ATO isolation transformer? Here is a good explanation about it in this video. To test the accuracy of the transformer voltage, we take a 3000 VA single phase 220V iuput to 110V output isolation transformer as an example.

Product reviews
Converts 480V to 240V or 240V to 480V
5
Thomas
Avatar
6/4/2018 7:07 PM
The 10 kVA isolation transformer converts 480V to 240V or 240V to 480V. It does not change the frequency.
Was this review helpful? Yes No (1/0)
Excellent protection for my service bench
5
Don Abraham
Avatar
7/28/2018 4:46 AM
The isolation transformer appears to be well constructed, and it does. Excellent protection for my service bench while live operating testing circuits.
Was this review helpful? Yes No (0/0)
A question about 10 kVA isolation transformer
5
Shairad
Avatar
9/25/2018 7:47 PM
I buy a machine in China which is 220 v, and I bring it to USA to use. Should I choose this 10kVA transformer to convert 220 v- 110v, or convert 110v-220v?
Was this review helpful? Yes No (0/0)
ATO Responded
Dear friend, the machine you bought in China is 220V therefore your output on the transformer should be 220V. The input into the transformer should be 110V because you are in US. 220V primary voltage, 110V secondary voltage transformer is the item you need. And all isolation transformers om ATO.com are step up & step down transformers.
Questions
5
Melanie
Avatar
1/5/2020 7:10 PM
What is the momentary overload tolerance of your 3 phase isolation transformers before the core begins to saturate?
Was this review helpful? Yes No (0/0)
ATO Responded
It depends on the loading time.
If it is within 30 minutes, the overload capacity can reach 1.2 times the capacity.
And if it is within 10 seconds, the overload capacity can reach 3-5 times the capacity.
Perfect isolation transformer
5
Fudd
Avatar
6/4/2021 1:13 AM
Can you provide IECEx flameproof isolation transformers?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can provide IECEx flameproof transformer fit for zone 1 or at least gas group IIB.
What is max. allowable operating temperature for this one?
5
Drew
Avatar
4/5/2023 8:09 PM
Referring to this one, what is the max. allowable operating temperature for the 10 kVA isolation transformer?
Was this review helpful? Yes No (0/0)
ATO Responded
The ambient temperature plus indoor temperature of 10kVA isolation transformer is generally about 60-70 degrees, and the maximum temperature rise inside the transformer is about 110-120 degrees.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

10 kVA dry type isolation transformer step down 3 phase voltage 400V to 3 phase 240V, step up 240V to 400V version is available. It is designed for use in control circuits and general applications such as mechanical and electronic equipment, precision machine tool, CNC machine tool, lighting, etc.

10 kVA Isolation Transformer Specifications

BasicsModelATO-SG10KVA
Phase3 phase
Capacity10 kVA
Weight of Aluminium Wire TransformerOpen type: 75kg
Protected type: 96kg
Weight of Copper Wire TransformerOpen type: 78kg
Protected type: 98kg
Technical ParametersPrimary Voltage400V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Secondary Voltage240V (Optional: 120V/ 190V/ 208V/ 220V/ 230V/ 240V/ 380V/ 400V/ 415V/ 480V)
Frequency50Hz / 60 Hz
Winding MaterialAluminium/Copper wire (Optional)
Work Efficiency≥95%
Insulation Resistance≥50 MΩ
Electrical Strength3000V AC/1 min
Noise<35-65dB (1 meter)
Insulation GradeH level
Wiring ModeDyn11
Cooling ModeDry type air cooling
Overload CapacityAllow more than 1.2 times rated load to work for up to 4 hours
Enclosure Protection GradeIP 24
CertificateCE, ISO
Warranty12 months
Working EnvironmentTemperature-15℃~+40℃
Humidity≤90%RH, without condensation
Altitude<1000m, non corrosive gas and conductive dust

Note:

Transformer can only convert voltage and CANNOT convert frequency.
Transformer CANNOT convert single phase voltage to 3 phase voltage.
Input/output voltage, power rating and whether with shell of all transformers, can be customized according to clients' requirements.

3 Phase Isolation Transformer Schematic Diagram

ATO isolation transformers schematic diagram

3 Phase Isolation Transformer Details

3-phase isolation transformer details

10 kVA Isolation Transformer Installation Dimension

3 phase isolation transformer dimension

Aluminium Wire Transformer SizeCopper Wire Transformer Size
Open type: a*b*c=380*240*380mmOpen type: a*b*c=380*240*380mm
Mouting size: d*e=260*150mmMouting size: d*e=260*150mm
Protected type: A*B*C=380*530*560mmProtected type: A*B*C=380*530*560mm

Tips: What is a 10 kVA isolation transformer?

10 kVA isolation transformer is a step up & step down 3 phase isolation transformer whose input windings and output windings have electrical isolation, it can avoid accidentally contact with the charged body at the same time. The transformer can isolate the respective current of primary and secondary windings. Its principle is the same with ordinary dry-type transformer, also use electromagnetic induction principle to isolate primary power circuit and secondary circuit ground floating to ensure electrical safety. ATO isolation transformers are widely used for control power of general circuit, power of safety lighting and indicator light in the electronics industry, mining enterprises and machine equipment.

Product reviews
Converts 480V to 240V or 240V to 480V
5
Thomas
Avatar
6/4/2018 7:07 PM
The 10 kVA isolation transformer converts 480V to 240V or 240V to 480V. It does not change the frequency.
Was this review helpful? Yes No (1/0)
Excellent protection for my service bench
5
Don Abraham
Avatar
7/28/2018 4:46 AM
The isolation transformer appears to be well constructed, and it does. Excellent protection for my service bench while live operating testing circuits.
Was this review helpful? Yes No (0/0)
A question about 10 kVA isolation transformer
5
Shairad
Avatar
9/25/2018 7:47 PM
I buy a machine in China which is 220 v, and I bring it to USA to use. Should I choose this 10kVA transformer to convert 220 v- 110v, or convert 110v-220v?
Was this review helpful? Yes No (0/0)
ATO Responded
Dear friend, the machine you bought in China is 220V therefore your output on the transformer should be 220V. The input into the transformer should be 110V because you are in US. 220V primary voltage, 110V secondary voltage transformer is the item you need. And all isolation transformers om ATO.com are step up & step down transformers.
Questions
5
Melanie
Avatar
1/5/2020 7:10 PM
What is the momentary overload tolerance of your 3 phase isolation transformers before the core begins to saturate?
Was this review helpful? Yes No (0/0)
ATO Responded
It depends on the loading time.
If it is within 30 minutes, the overload capacity can reach 1.2 times the capacity.
And if it is within 10 seconds, the overload capacity can reach 3-5 times the capacity.
Perfect isolation transformer
5
Fudd
Avatar
6/4/2021 1:13 AM
Can you provide IECEx flameproof isolation transformers?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can provide IECEx flameproof transformer fit for zone 1 or at least gas group IIB.
What is max. allowable operating temperature for this one?
5
Drew
Avatar
4/5/2023 8:09 PM
Referring to this one, what is the max. allowable operating temperature for the 10 kVA isolation transformer?
Was this review helpful? Yes No (0/0)
ATO Responded
The ambient temperature plus indoor temperature of 10kVA isolation transformer is generally about 60-70 degrees, and the maximum temperature rise inside the transformer is about 110-120 degrees.
Only registered users can write reviews
Customers who bought this item also bought

200 hp (160 kW) VFD, 3 Phase 240V, 420V, 480V

GK3000-4T1600G
$6,979.36
Favorable price 200 hp (160 kW) VFD for electric motor speed controls, 3 phase 240V, 420V, 480V is optional, brand new variable frequency drive sale by manufacturer directly.

40 hp (30 kW) Soft starter, 60 A, 3ph 220v/380v/480v

GS-030
$449.20
Cheap price 40 hp soft starter for sale, 30 kW three phase 220v, 380v, 480v AC motor soft starter for choice, make motor in soft start & soft stop, buy from manufacturer directly.

Digital Rotary Torque Sensor, 0.1/5/300/1000 Nm to 10000 Nm

ATO-TQS-D03
$939.15
Digital rotary torque sensor with LCD display has the capacity range from 0.1 Nm/0.3 Nm/1 Nm/5 Nm/10 Nm/300 Nm/1000 Nm to 10000 Nm. LCD display can show torque, speed and power value at the same time. Dynamic torque sensor adopts two NSK shafts to ensure starting torque as low as 0.00001 Nm. Rotary torque transducer with 7 pin waterproof circular connector and 3m cable can measure both forward and reverse torque, and then output ±5V/0-10V/4-20mA/RS485 torque signal to PLC.

10 hp (7.5 kW) Soft starter, 15 A, 3ph 220v/400v/480v

GS-7d5
$352.31
Favorable price 10 hp soft starter, 7.5 kW 3 phase 220v, 400v, 480v electric motor soft starts, make motor in soft start & soft stop, direct sale from manufacturer.