10 hp (7.5 kW) Soft starter, 15 A, 3ph 220v/400v/480v

$352.31
Favorable price 10 hp soft starter, 7.5 kW 3 phase 220v, 400v, 480v electric motor soft starts, make motor in soft start & soft stop, direct sale from manufacturer.
SKU: GS-7d5
Free Shipping
Delivery date: 6-12 days

10 hp motor soft starter, 7.5 kW three phase 220v, 400v, 480v, 690v for choice.

ModelGS2-7d5 (220v, 240v), GS3-7d5 (380v, 400v, 415v), GS4-7d5 (460v, 480v), GS6-7d5 (575v, 690v).
Capacity10 hp (7.5 kw)
Current

15 amps at 380/480v, 30 amps at 220v, 11 amps at 690v

Weight5 kgs
Dimension270*146*160 mm
InputVoltageThree-phase 220v, 380v, 480v, 690v AC
Frequency50Hz/ 60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.
485 CommunicationDB9 interface, male plug, ① is RS485+, ⑥ is RS485-
Control Mode
  1. Operation panel control.
  2. Operation panel + external control.
  3. External control.
  4. External control + COM control.
  5. Operation panel + external + COM control.
  6. Operation panel + COM control.
  7. COM control.
  8. No start or stop operation.
Start Mode
  1. Current-limiting to start.
  2. Voltage ramp to start.
  3. Torque control + current-limiting to start.
  4. Torque control + voltage ramp to start.
  5. Current ramp to start.
  6. Voltage current-limiting double closed-loop start.
Stop Mode
  1. Soft stop.
  2. Free stop.
Protective Function
  1. Open loop protection for external instantaneous stop terminals.
  2. Over-heat protection for soft starter.
  3. Protection for too long starting time.
  4. Input open phase protection.
  5. Output open phase protection.
  6. Unbalanced three-phase protection.
  7. Starting over current protection.
  8. Running overload protection.
  9. Under voltage protection for power voltage.
  10. Overvoltage protection for power voltage.
  11. Protection for fault parameter setting of the soft starter.
  12. Load short circuit protection.
  13. Auto restart or incorrect wiring protection.
  14. Incorrect wiring protection of external control stop terminals.
AmbientPlace to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
AltitudeBelow 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
Temperature-30 +55 oC
Humidity90%RH without dew condensation.
Vibration<0.5G
StructureEnclosureIP 20
CoolingNatural wind cooling.

Details

7.5KW Soft Starters Details

Tips: Motor soft starter model selection
In actual working should consider the specific product features and technical parameters and product reliability, and according to the actual usage to choose the soft starter. Here it is necessary to differentiate that motor is frequent start or infrequent start. For the soft starter, in general, if the motor start interval time does not exceed 2 minutes, and 30 times per hour, can be identified as infrequent start. Less than 2 minutes should be considered as frequent start. Fan and pump load generally belong to infrequent start. Mechanical transmission type like belt machine, grinding mill, and others can be considered as infrequent start. If the motor is starter, or electromotor that is equipped for the large machinery equipment needing reversible function, mostly belongs to frequent start.
Choosing a soft starter for frequent working place should according to the motor starting current. Normal soft starter silicone controlled rectifier current is 2.5 times of motor rated current. Limit the maximum motor starting current is 4.5 times of the rated current. In the infrequent operation can take full advantage of SCR short-term overload capacity. In the conditions of frequent starting, should select increasing the soft starter capacity, according to the different of frequency take 1.2 to 1.5 times of the capacity. At the same time, due to the SCR frequent working and generating a lot of heat, the soft starter must be equipped with mechanical air-cooled to dissipate heat. It is best to put a mechanical air-cooled soft start device for each switchgear, and the switchgear should also be set with mechanical ventilation.

Soft Starter Works with a Bypass Contactor

Soft starter works with a bypass contactor saving energy by eliminating thyristor losses during the run. The bypass contactor shunts the current flowing through the soft starter switch circuit to reduce heat accumulation in the soft starter power electronics during motor operation. This provides maximum efficiency and prolongs the life of soft-start switching components because they only work during the start and stop cycles of the motor.

How to Change the Soft Starter Rated Current

Delayed Soft Start of A Motor

In this video, we introduce how to use a soft starter together with a bypass contactor to achieve a delayed soft start of a motor.

Product reviews
Good product, meets my need
5
Wright
Avatar
3/5/2019 7:37 PM
This 15A soft starter is applied to my 25A motor. I can handle the unit with no trouble. All the parameters are set on the panel by knob potentiometers and dial switch, that is intuitive and accurate. I feel my motor works really much better than before.
Was this review helpful? Yes No (0/0)
Can I start your 50hp soft starter remotely with a 120 volt switch?
5
Dale
Avatar
12/2/2021 2:10 AM
Can I start your 50hp soft starter remotely with a 120 volt switch?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, sure. This soft starter remote control can be done via (wires + switch), therefore, you can use 120V to control a relay, and then control the start and stop of the soft starter through the contact switch of the relay. It is a very simple control method.
One thing I found weird
5
Glack
Avatar
4/4/2023 12:03 AM
I just installed this soft starter. One thing I found weird as well (which sucks) is I ran power through the by pass contacts (1
Was this review helpful? Yes No (0/0)
ATO Responded
1. The bypass contact (1&2) of the soft starter is used to control the coil of the bypass contactor. The rated capacity of the bypass contact (1&2) is only 250V/5A.  The coil voltage of the bypass contactor is also required to be lower than 250V.
2. Suppose your grid voltage is three-phase 380V, and the bypass contactor coil is 220V, then the voltage of one live wire and one natural wire in the grid (L+N=220V).  You can connect a live wire L in the grid to a terminal A1 of the contactor coil through the bypass contact (1&2), and connect the other end A2 of the contactor coil to the natural wire N.
3. If the soft starter has burned out, you need to buy another new one, please refer to the link: https://www.ato.com/softstarter
Could you please provide your motor nameplate to us for further confirmation?
What terminals I need to hook into for a start/stop switch on this drive?
5
wyatt
Avatar
11/26/2023 8:11 PM
Hello,  I'm wondering what terminals I need to hook into for a start/stop switch on this drive.  I watched the YouTube video but I don't have that 3 position switch. All I have is a start/stop button or an on/off switch. Thanks
Was this review helpful? Yes No (0/0)
ATO Responded
Please short-circuit terminals 7 and 10 of the soft starter to lead out a wire, short-circuit terminals 8 and 9 to lead out a wire, and connect these two wires to your switch or button.
When these two wires are closed, the machine will start, and when these two wires are disconnected, the machine will stop.
reliable 10 hp soft starter
4
Oscar1
Avatar
10/7/2025 8:52 PM
I've been using the 10 hp soft starter for a few months now, and it delivers really smooth startups for my machinery. The variety of voltage options and built in protective functions are a major advantage. My only minor gripe is that the 20 starts per hour limit can be a bit tight during peak operations. Still, it's a dependable device that gets the job done well.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

10 hp motor soft starter, 7.5 kW three phase 220v, 400v, 480v, 690v for choice.

ModelGS2-7d5 (220v, 240v), GS3-7d5 (380v, 400v, 415v), GS4-7d5 (460v, 480v), GS6-7d5 (575v, 690v).
Capacity10 hp (7.5 kw)
Current

15 amps at 380/480v, 30 amps at 220v, 11 amps at 690v

Weight5 kgs
Dimension270*146*160 mm
InputVoltageThree-phase 220v, 380v, 480v, 690v AC
Frequency50Hz/ 60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.
485 CommunicationDB9 interface, male plug, ① is RS485+, ⑥ is RS485-
Control Mode
  1. Operation panel control.
  2. Operation panel + external control.
  3. External control.
  4. External control + COM control.
  5. Operation panel + external + COM control.
  6. Operation panel + COM control.
  7. COM control.
  8. No start or stop operation.
Start Mode
  1. Current-limiting to start.
  2. Voltage ramp to start.
  3. Torque control + current-limiting to start.
  4. Torque control + voltage ramp to start.
  5. Current ramp to start.
  6. Voltage current-limiting double closed-loop start.
Stop Mode
  1. Soft stop.
  2. Free stop.
Protective Function
  1. Open loop protection for external instantaneous stop terminals.
  2. Over-heat protection for soft starter.
  3. Protection for too long starting time.
  4. Input open phase protection.
  5. Output open phase protection.
  6. Unbalanced three-phase protection.
  7. Starting over current protection.
  8. Running overload protection.
  9. Under voltage protection for power voltage.
  10. Overvoltage protection for power voltage.
  11. Protection for fault parameter setting of the soft starter.
  12. Load short circuit protection.
  13. Auto restart or incorrect wiring protection.
  14. Incorrect wiring protection of external control stop terminals.
AmbientPlace to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
AltitudeBelow 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
Temperature-30 +55 oC
Humidity90%RH without dew condensation.
Vibration<0.5G
StructureEnclosureIP 20
CoolingNatural wind cooling.

Details

7.5KW Soft Starters Details

Tips: Motor soft starter model selection
In actual working should consider the specific product features and technical parameters and product reliability, and according to the actual usage to choose the soft starter. Here it is necessary to differentiate that motor is frequent start or infrequent start. For the soft starter, in general, if the motor start interval time does not exceed 2 minutes, and 30 times per hour, can be identified as infrequent start. Less than 2 minutes should be considered as frequent start. Fan and pump load generally belong to infrequent start. Mechanical transmission type like belt machine, grinding mill, and others can be considered as infrequent start. If the motor is starter, or electromotor that is equipped for the large machinery equipment needing reversible function, mostly belongs to frequent start.
Choosing a soft starter for frequent working place should according to the motor starting current. Normal soft starter silicone controlled rectifier current is 2.5 times of motor rated current. Limit the maximum motor starting current is 4.5 times of the rated current. In the infrequent operation can take full advantage of SCR short-term overload capacity. In the conditions of frequent starting, should select increasing the soft starter capacity, according to the different of frequency take 1.2 to 1.5 times of the capacity. At the same time, due to the SCR frequent working and generating a lot of heat, the soft starter must be equipped with mechanical air-cooled to dissipate heat. It is best to put a mechanical air-cooled soft start device for each switchgear, and the switchgear should also be set with mechanical ventilation.

Product reviews
Good product, meets my need
5
Wright
Avatar
3/5/2019 7:37 PM
This 15A soft starter is applied to my 25A motor. I can handle the unit with no trouble. All the parameters are set on the panel by knob potentiometers and dial switch, that is intuitive and accurate. I feel my motor works really much better than before.
Was this review helpful? Yes No (0/0)
Can I start your 50hp soft starter remotely with a 120 volt switch?
5
Dale
Avatar
12/2/2021 2:10 AM
Can I start your 50hp soft starter remotely with a 120 volt switch?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, sure. This soft starter remote control can be done via (wires + switch), therefore, you can use 120V to control a relay, and then control the start and stop of the soft starter through the contact switch of the relay. It is a very simple control method.
One thing I found weird
5
Glack
Avatar
4/4/2023 12:03 AM
I just installed this soft starter. One thing I found weird as well (which sucks) is I ran power through the by pass contacts (1
Was this review helpful? Yes No (0/0)
ATO Responded
1. The bypass contact (1&2) of the soft starter is used to control the coil of the bypass contactor. The rated capacity of the bypass contact (1&2) is only 250V/5A.  The coil voltage of the bypass contactor is also required to be lower than 250V.
2. Suppose your grid voltage is three-phase 380V, and the bypass contactor coil is 220V, then the voltage of one live wire and one natural wire in the grid (L+N=220V).  You can connect a live wire L in the grid to a terminal A1 of the contactor coil through the bypass contact (1&2), and connect the other end A2 of the contactor coil to the natural wire N.
3. If the soft starter has burned out, you need to buy another new one, please refer to the link: https://www.ato.com/softstarter
Could you please provide your motor nameplate to us for further confirmation?
What terminals I need to hook into for a start/stop switch on this drive?
5
wyatt
Avatar
11/26/2023 8:11 PM
Hello,  I'm wondering what terminals I need to hook into for a start/stop switch on this drive.  I watched the YouTube video but I don't have that 3 position switch. All I have is a start/stop button or an on/off switch. Thanks
Was this review helpful? Yes No (0/0)
ATO Responded
Please short-circuit terminals 7 and 10 of the soft starter to lead out a wire, short-circuit terminals 8 and 9 to lead out a wire, and connect these two wires to your switch or button.
When these two wires are closed, the machine will start, and when these two wires are disconnected, the machine will stop.
reliable 10 hp soft starter
4
Oscar1
Avatar
10/7/2025 8:52 PM
I've been using the 10 hp soft starter for a few months now, and it delivers really smooth startups for my machinery. The variety of voltage options and built in protective functions are a major advantage. My only minor gripe is that the 20 starts per hour limit can be a bit tight during peak operations. Still, it's a dependable device that gets the job done well.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews
Customers who bought this item also bought

Custom Order

ATO-CUSTOM
Pay for custom orders, or extra amount of existing orders.
Indicate the item specification you pay for, and specify PI / PO number if you have.

Float Switch Level Sensor, Stainless Steel/ Plastic

ATO-ES12010-2A1
$61.43
Stainless steel and plastic float switch level sensor is composed magnetic spring switch and floating ball to detecting the position of the liquid level. Vertical mounted, contact power rating 50W.

200 hp (160 kW) VFD, 3 Phase 240V, 420V, 480V

GK3000-4T1600G
$6,979.36
Favorable price 200 hp (160 kW) VFD for electric motor speed controls, 3 phase 240V, 420V, 480V is optional, brand new variable frequency drive sale by manufacturer directly.

15 hp (11 kW) Soft starter, 22A, 3ph 240v/400v/480v

GS-011
$367.93
Low cost 15 hp soft starter, 11 kW three phase 240v, 400v, 480v AC motor soft starter, protecting AC motor from over-voltage, over-current and phase unbalance etc.

40 hp (30 kW) Soft starter, 60 A, 3ph 220v/380v/480v

GS-030
$449.20
Cheap price 40 hp soft starter for sale, 30 kW three phase 220v, 380v, 480v AC motor soft starter for choice, make motor in soft start & soft stop, buy from manufacturer directly.