25 hp AC motor soft starter, 18 kW three phase 220v, 400v, 460v, 690v motor soft starter.
| Model | GS2-018 (220v, 240v), GS3-018 (380v, 400v, 415v), GS4-018 (460v, 480v), GS6-018 (575v, 690v). | ||
| Capacity | 25 hp (18 kw) | ||
| Current | 37 amps at 380v/480v, 75 amps at 220v, 26 amps at 690v | ||
| Weight | 5 kgs | ||
| Dimension | 270*146*160 mm | ||
| Input | Voltage | Three-phase 230v, 415v, 480v, 660v AC | |
| Frequency | 50Hz/ 60Hz | ||
| Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
| Starting Times | It is recommended not to exceed 20 times per hour. | ||
| 485 Communication | DB9 interface, male plug, ① is RS485+, ⑥ is RS485- | ||
| Control Mode |
| ||
| Start Mode |
| ||
| Stop Mode |
| ||
| Protective Function |
| ||
| Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
| Altitude | Below 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M. | ||
| Temperature | -30 +55 oC | ||
| Humidity | 90%RH without dew condensation. | ||
| Vibration | <0.5G | ||
| Structure | Enclosure | IP 20 | |
| Cooling | Natural wind cooling. | ||
Details

Tips: Soft starter application fields
The soft starter can effectively limit the starting current of AC asynchronous motor, and can be widely used in fans, water pumps, transportation, compressor and other loads. It is the ideal replacement product of traditional star-delta conversion, self-couple decrease-voltage, and magnetic-control decrease-voltage equipment. AC motor soft starter has a very good energy saving effect. It uses a thyristor to reduce voltage, the power factor is low when the soft start load is light, and the soft starter can improve the power factor by reducing the control voltage, in order to achieve light load energy saving effect. The fans, pumps and other load starting torque is low, the torque will increase with the speed. When using the soft start mode can reduce the inrush starting current well, and in the shutdown we can use soft-stop to avoid water hammer effect. When you need to reduce the exciting current, you can change the effective value of the output voltage, so to achieve the purpose of adjusting the speed, while improving the system power factor, achieving optimizing the energy saving effect.
I have not powered on your device at all because the information supplied is uncomplete. I need to see how your soft starter is connected to neutral and a neutral connection to the 3φ motor. Please show this essential information plainly in wiring diagram and pictures. Your pictures are not adequate. There are only 2 color wires Red and blue. The white labels are mostly unreadable. No ground wire shown. No neutral or ground to the motor or soft starter. This is not right. Please show all of this information clearly.