75 hp motor soft starter, 55 kW three phase 220v, 380v, 480v, 690v for choice.
| Model | GS2-055 (220v, 240v), GS3-055 (380v, 400v, 415v), GS4-055 (460v, 480v), GS6-055 (575v, 690v). | ||
| Capacity | 75 hp (55 kw) | ||
| Current | 110 amps at 380v/480v, 230 amps at 220v, 70 amps at 690v | ||
| Weight | 5 kgs | ||
| Dimension | 270*146*160 mm | ||
| Input | Voltage | Three-phase 240v, 440v, 480v, 660v AC | |
| Frequency | 50Hz/ 60Hz | ||
| Adaptive Motor | Squirrel-cage three-phase asynchronous motor | ||
| Starting Times | It is recommended not to exceed 20 times per hour. | ||
| 485 Communication | DB9 interface, male plug, ① is RS485+, ⑥ is RS485- | ||
| Control Mode |
| ||
| Start Mode |
| ||
| Stop Mode |
| ||
| Protective Function |
| ||
| Ambient | Place to be used | Indoor location with good ventilation free from corrosive gas and conductive dust. | |
| Altitude | Below 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M. | ||
| Temperature | -30 +55 oC | ||
| Humidity | 90%RH without dew condensation. | ||
| Vibration | <0.5G | ||
| Structure | Enclosure | IP 20 | |
| Cooling | Natural wind cooling. | ||
Details

Soft starter starting fault and its handling method part 1
- When the user using the soft starter, the display screen has no display or there is messy code and the soft starter does not work. The causes for the malfunction may be:
In the use process, the vibrations of the soft starter caused by the external components make the internal connection of the soft starter loose. (Open the soft starter cover to re-insert the screen connection.)
Soft starter control board failure. (Connect with the manufacturers to replace the control panel.) - When the soft starter is in the starting load, there is overtime starting phenomenon. The soft starter stops working and the motor is free to stop. The causes for the malfunction are:
Parameter settings are unreasonable. (Reset the parameters, appropriately rise the starting voltage and appropriately lengthen the time.)
Start at full load. (Minimize the load when starting.) - In the starting process, if there is superheat malfunction, the light is on, and the soft starter to stop working:
Frequent start results in excess temperature, causes soft starter overheating protection action. (The number of starts of the soft starter shall be controlled at no more than 6 times per hour, especially pay attention to the heavy load.)
During the starting process, the protective element is actuated so that the contactor cannot be bypassed and the soft starter is operated for a long time, causing a protective action. (Check the peripheral circuit.)
The heavy load and the over-length starting time cause overheating protection. (When starting, reduce the load as much as possible.)
Soft starter parameter setting is unreasonable. Time is too long, and the starting voltage is too low. (Increase the starting voltage.)
The soft starter's cooling fan is damaged and does not work properly. (Replace the fan.) - In the use process of the users, there are phenomena that the starting is completed and the bypass contactor does not have pull-in phenomena. The causes for the malfunction may be:
In the starting process, the protection device is malfunctioning due to the setting. (The protective device can be reset.)
In the debugging, the soft starter parameter settings are unreasonable. (Mainly for the soft starter below 75hp, reset the parameters of the soft starter.)
Poor control line contact. (Check control line.)
Product reviews
High quality 75hp soft starter
Mroz
7/20/2021 9:37 PM
I am looking at your “75 hp soft starters“, what is the input current reduction using the soft starter? Your spec does not say if it reduces 20%, 50%, or what? Some soft starters reduce current to 200% nominal (300% inrush vs 600%). What do yours do?
Was this review helpful? (0/0)
I need a bypass contactor.
Della
7/27/2022 3:07 AM
I am trying to locate the bypass contactor that is needed for soft motor starter Model: EM-GS4-055.
Was this review helpful? (0/0)
We need help soft starter wiring for remote start
norbert
6/7/2023 3:42 AM
We need help wiring for remote start.
We tried the way it is in your schematic and it comes on without hitting remote start.
We tried the way it is in your schematic and it comes on without hitting remote start.
Was this review helpful? (0/0)
I am using your soft starter on an irrigation pump.
rayparker
6/29/2023 7:12 PM
I will use my contactor from my pump to start the soft starter. When my pump contactor kicks in the soft starter starts when I push the run button it ramps up for a few seconds and shut down. the contactor is still on. I need it start when the pump contactor kicks in and stay running until the pump has finished. I am not using a bypass contactor. can you help with this installation?
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
30 hp (22 kW) Soft starter, 43 A, 3ph 240v/415v/480v
GS-022
$426.11
Low cost 30 hp soft starter, 22 kW 3 phase 240v, 415v, 480v affordable motor soft starter direct sale from manufacturer from China.
15 hp (11 kW) Soft starter, 22A, 3ph 240v/400v/480v
GS-011
$367.93
Low cost 15 hp soft starter, 11 kW three phase 240v, 400v, 480v AC motor soft starter, protecting AC motor from over-voltage, over-current and phase unbalance etc.
60 hp (45 kW) Soft starter, 90 A, 3ph 240v/400v/480v
GS-045
$543.91
Affordable 60 hp soft starter, 45 kW three phase 240v, 400v, 480v AC motor starter, protect AC induction motor from inrush current impact, buy from Chinese manufacturer directly.
200 hp (150 kW) Soft starter, 300 A, 3ph 240v/400v/480v
GS-150
$1,379.53
Low price 200 hp soft starter, 150 kW 3 phase 240v, 400v, 480v, 690v motor starter, control AC induction motor in soft start & soft stop, buy from China manufacturer directly.