50 hp (37 kW) Soft starter, 75 A, 3ph 240v/400v/480v

$479.12
Inexpensive 50 hp soft starter, 37 kW three phase 240v, 400v, 480v for selection, make induction motor in soft start & soft stop, sell by manufacturer directly.
SKU: GS-037
Free Shipping
Delivery date: 2-3 days

50 hp soft starter, 37 kW three phase 240v, 400v, 480v, 690v AC motor starter for selection.

ModelGS2-037 (220v, 240v), GS3-037 (380v, 400v, 415v), GS4-037 (460v, 480v), GS6-037 (575v, 690v).
Capacity50 hp (37 kw)
Current75 amps at 380v/480v, 150 amps at 220v
Weight5 kgs
Dimension270*146*160 mm
InputVoltageThree-phase 230v, 380v, 460v, 690v AC
Frequency50Hz/ 60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.
485 CommunicationDB9 interface, male plug, ① is RS485+, ⑥ is RS485-
Control Mode
  1. Operation panel control.
  2. Operation panel + external control.
  3. External control.
  4. External control + COM control.
  5. Operation panel + external + COM control.
  6. Operation panel + COM control.
  7. COM control.
  8. No start or stop operation.
Start Mode
  1. Current-limiting to start.
  2. Voltage ramp to start.
  3. Torque control + current-limiting to start.
  4. Torque control + voltage ramp to start.
  5. Current ramp to start.
  6. Voltage current-limiting double closed-loop start.
Stop Mode
  1. Soft stop.
  2. Free stop.
Protective Function
  1. Open loop protection for external instantaneous stop terminals.
  2. Over-heat protection for soft starter.
  3. Protection for too long starting time.
  4. Input open phase protection.
  5. Output open phase protection.
  6. Unbalanced three-phase protection.
  7. Starting over current protection.
  8. Running overload protection.
  9. Under voltage protection for power voltage.
  10. Overvoltage protection for power voltage.
  11. Protection for fault parameter setting of the soft starter.
  12. Load short circuit protection.
  13. Auto restart or incorrect wiring protection.
  14. Incorrect wiring protection of external control stop terminals.
AmbientPlace to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
AltitudeBelow 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
Temperature-30 +55 oC
Humidity90%RH without dew condensation.
Vibration<0.5G
StructureEnclosureIP 20
CoolingNatural wind cooling.

Details

37KW Soft Starters Details

Tips: Soft starter installation methods

  1. The soft starter should install indoors in accordance with the shell protection level (usually IP20) requirement.
  2. Should install vertically, in the top and bottom of the soft starter should leave space at least 200mm width to facilitate heat dissipation.
  3. If the control cabinet is equipped with thermal relay, should use segregation board to prevent cold or hot airflow blowing to the thermal relay, to avoid affecting the action value of the thermal relay.
  4. Carefully read the instructions to understand the function of each terminal, ensure correct wiring.
  5. Usually don't use megger test the phase and relative to the ground insulation resistance. If it is necessary, must let three-phase input and output short circuit, and unplug all the plugs on the control panel, and then testing.
  6. When the soft starter input connects to the power supply, the output will bring a high induction voltage when the load opens circuit or loss of phase. So when in installation, commission, maintenance and use, prohibit contacting the soft starter output terminal, so as not to causing electric shock accident.
  7. If soft starter connects compensation capacitors to improve the power factor, the capacitor must connect to the soft starter input terminal, not output terminal, otherwise it will cause damage to the soft starter.
  8. The soft starter input and output terminals can't be connected reversely, otherwise it may cause damage to the soft starter and motor.
  9. If the soft starter has bypass contactor, carefully wiring (connect the contactor main contact) , can't cause short-circuit accident.
  10. When measure the motor insulation resistance, must disconnect the three lines between soft starter before proceeding.

Soft Starter Works with a Bypass Contactor

Soft starter works with a bypass contactor saving energy by eliminating thyristor losses during the run. The bypass contactor shunts the current flowing through the soft starter switch circuit to reduce heat accumulation in the soft starter power electronics during motor operation. This provides maximum efficiency and prolongs the life of soft-start switching components because they only work during the start and stop cycles of the motor.

How to Change the Soft Starter Rated Current

Delayed Soft Start of A Motor

In this video, we introduce how to use a soft starter together with a bypass contactor to achieve a delayed soft start of a motor.

Product reviews
Control method of 50 hp soft starter
5
Jules
Avatar
5/17/2021 1:21 AM
Can I start your 50hp soft starter remotely with a 120 volt switch?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, sure. This soft starter remote control can be done via (wires + switch), therefore, you can use 120V to control a relay, and then control the start and stop of the soft starter through the contact switch of the relay. It is a very simple control method.
50hp 480V soft starter
5
Oliver
Avatar
11/6/2023 1:37 AM
We purchased a 50hp 480V soft starter last year and finally got around to installing it.
Upon start up it powered up and started the motor but would shut off after about 20-30 seconds.
We tried several different settings but could not get it to remain running
The application is a submersible motor and turbine pump.
The motor is 40Hp
Any help or guidance is appreciated
Was this review helpful? Yes No (0/0)
ATO Responded
We need your feedback on the following information to better support you:
1. Please send us the nameplate pictures of the soft start and motor. And tell us how far away is the submersible motor from soft start?
2. Please send complete wiring pictures of our soft starter and motor.
3. Please provide us with a video to confirm how the soft start operation works. What is the fault code that occurs during operation? You can send us the large video file via wetransfer.com.
Regarding wiring, you can refer to our demonstration video, see on: https://www.youtube.com/watch?v=GkSo1DOBHlM
Use large-sized devices
5
Biente
Avatar
1/12/2025 8:28 PM
I plan to use a greatly oversize unit to be certain that I can make the required number of reversals for one part of the application that could exceed your 20/hour limit. Since your unit is not fan cooled and the larger sizes are a tolerable price. If necessary, I could provide a little forced ventilation.
Was this review helpful? Yes No (0/0)
ATO Responded
We do Not recommend frequent soft start for more than 20 times. Because this may cause the internal thyristor to heat up severely and damage, even if an external fan is added for cooling. So if you want to start the motor frequently, would you consider using a VFD to control the motor? VFD can increase the capacity and have its own fan for cooling. It would be better if you can provide us with a picture of the motor nameplate label and tell us what the load is that is driven.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

50 hp soft starter, 37 kW three phase 240v, 400v, 480v, 690v AC motor starter for selection.

ModelGS2-037 (220v, 240v), GS3-037 (380v, 400v, 415v), GS4-037 (460v, 480v), GS6-037 (575v, 690v).
Capacity50 hp (37 kw)
Current75 amps at 380v/480v, 150 amps at 220v
Weight5 kgs
Dimension270*146*160 mm
InputVoltageThree-phase 230v, 380v, 460v, 690v AC
Frequency50Hz/ 60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.
485 CommunicationDB9 interface, male plug, ① is RS485+, ⑥ is RS485-
Control Mode
  1. Operation panel control.
  2. Operation panel + external control.
  3. External control.
  4. External control + COM control.
  5. Operation panel + external + COM control.
  6. Operation panel + COM control.
  7. COM control.
  8. No start or stop operation.
Start Mode
  1. Current-limiting to start.
  2. Voltage ramp to start.
  3. Torque control + current-limiting to start.
  4. Torque control + voltage ramp to start.
  5. Current ramp to start.
  6. Voltage current-limiting double closed-loop start.
Stop Mode
  1. Soft stop.
  2. Free stop.
Protective Function
  1. Open loop protection for external instantaneous stop terminals.
  2. Over-heat protection for soft starter.
  3. Protection for too long starting time.
  4. Input open phase protection.
  5. Output open phase protection.
  6. Unbalanced three-phase protection.
  7. Starting over current protection.
  8. Running overload protection.
  9. Under voltage protection for power voltage.
  10. Overvoltage protection for power voltage.
  11. Protection for fault parameter setting of the soft starter.
  12. Load short circuit protection.
  13. Auto restart or incorrect wiring protection.
  14. Incorrect wiring protection of external control stop terminals.
AmbientPlace to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
AltitudeBelow 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
Temperature-30 +55 oC
Humidity90%RH without dew condensation.
Vibration<0.5G
StructureEnclosureIP 20
CoolingNatural wind cooling.

Details

37KW Soft Starters Details

Tips: Soft starter installation methods

  1. The soft starter should install indoors in accordance with the shell protection level (usually IP20) requirement.
  2. Should install vertically, in the top and bottom of the soft starter should leave space at least 200mm width to facilitate heat dissipation.
  3. If the control cabinet is equipped with thermal relay, should use segregation board to prevent cold or hot airflow blowing to the thermal relay, to avoid affecting the action value of the thermal relay.
  4. Carefully read the instructions to understand the function of each terminal, ensure correct wiring.
  5. Usually don't use megger test the phase and relative to the ground insulation resistance. If it is necessary, must let three-phase input and output short circuit, and unplug all the plugs on the control panel, and then testing.
  6. When the soft starter input connects to the power supply, the output will bring a high induction voltage when the load opens circuit or loss of phase. So when in installation, commission, maintenance and use, prohibit contacting the soft starter output terminal, so as not to causing electric shock accident.
  7. If soft starter connects compensation capacitors to improve the power factor, the capacitor must connect to the soft starter input terminal, not output terminal, otherwise it will cause damage to the soft starter.
  8. The soft starter input and output terminals can't be connected reversely, otherwise it may cause damage to the soft starter and motor.
  9. If the soft starter has bypass contactor, carefully wiring (connect the contactor main contact) , can't cause short-circuit accident.
  10. When measure the motor insulation resistance, must disconnect the three lines between soft starter before proceeding.

Product reviews
Control method of 50 hp soft starter
5
Jules
Avatar
5/17/2021 1:21 AM
Can I start your 50hp soft starter remotely with a 120 volt switch?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, sure. This soft starter remote control can be done via (wires + switch), therefore, you can use 120V to control a relay, and then control the start and stop of the soft starter through the contact switch of the relay. It is a very simple control method.
50hp 480V soft starter
5
Oliver
Avatar
11/6/2023 1:37 AM
We purchased a 50hp 480V soft starter last year and finally got around to installing it.
Upon start up it powered up and started the motor but would shut off after about 20-30 seconds.
We tried several different settings but could not get it to remain running
The application is a submersible motor and turbine pump.
The motor is 40Hp
Any help or guidance is appreciated
Was this review helpful? Yes No (0/0)
ATO Responded
We need your feedback on the following information to better support you:
1. Please send us the nameplate pictures of the soft start and motor. And tell us how far away is the submersible motor from soft start?
2. Please send complete wiring pictures of our soft starter and motor.
3. Please provide us with a video to confirm how the soft start operation works. What is the fault code that occurs during operation? You can send us the large video file via wetransfer.com.
Regarding wiring, you can refer to our demonstration video, see on: https://www.youtube.com/watch?v=GkSo1DOBHlM
Use large-sized devices
5
Biente
Avatar
1/12/2025 8:28 PM
I plan to use a greatly oversize unit to be certain that I can make the required number of reversals for one part of the application that could exceed your 20/hour limit. Since your unit is not fan cooled and the larger sizes are a tolerable price. If necessary, I could provide a little forced ventilation.
Was this review helpful? Yes No (0/0)
ATO Responded
We do Not recommend frequent soft start for more than 20 times. Because this may cause the internal thyristor to heat up severely and damage, even if an external fan is added for cooling. So if you want to start the motor frequently, would you consider using a VFD to control the motor? VFD can increase the capacity and have its own fan for cooling. It would be better if you can provide us with a picture of the motor nameplate label and tell us what the load is that is driven.
Only registered users can write reviews
Customers who bought this item also bought

7.5 hp (5.5 kW) VFD, 3 Phase 208V, 380V, 480V

GK3000-4T0055G
$415.08
7.5 hp (5.5 kW) VFD with wholesale price, 3 phase 208V/380V/480V 50Hz/60Hz for option, heavy duty variable frequency drive, 13 amps at 380V ~480V, strong overload capacity, manufacturer direct sale.

60 hp (45 kW) Soft starter, 90 A, 3ph 240v/400v/480v

GS-045
$543.91
Affordable 60 hp soft starter, 45 kW three phase 240v, 400v, 480v AC motor starter, protect AC induction motor from inrush current impact, buy from Chinese manufacturer directly.

30 hp (22 kW) Soft starter, 43 A, 3ph 240v/415v/480v

GS-022
$426.11
Low cost 30 hp soft starter, 22 kW 3 phase 240v, 415v, 480v affordable motor soft starter direct sale from manufacturer from China.

12 Amps 3 Pole AC Contactor 24V/110V/220V Coil

ATO-ACCON-012
$51.46
Buy AC contactors from manufacturer at good price, 3 pole contactor relay has the advantage of small volume, light wight and low cost. With coil voltages of 24V/110V or 220V AC, rated current 12A at 380V, 9A at 660V. As a bypass contactor frequently start and control AC electric motors.

10 hp (7.5 kW) VFD, Three Phase 220V, 440V, 480V

GK3000-4T0075G
$463.25
Affordable 10 hp (7.5 kW) VFD, three phase 220V/440V/480V input for option, three phase output variable frequency drive, 17 amps, V/F & vector control, manufacturer direct sale.