200 hp (160 kW) VFD, 3 Phase 240V, 420V, 480V

$6,979.36
Favorable price 200 hp (160 kW) VFD for electric motor speed controls, 3 phase 240V, 420V, 480V is optional, brand new variable frequency drive sale by manufacturer directly.
SKU: GK3000-4T1600G
Free Shipping
Delivery date: 6-12 days

200 hp VFD, 160 kW high quality three phase 240V, 420V, 480V variable frequency drive.

Specification:

BasicsModelGK3000-4T1600G/ GK3000-2T1600G
Capacity200 hp (160 kW)
Shipping weight90 kg
Dimension760*390*320 mm
I/O FeatureRated current304A at 380V ~ 480V, 585A at 220V ~ 240V
Input voltageThree phase 240V /420V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltageThree phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150 % of rated current for 1 minute, 200 % of rated current for 1 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive lightning protection measures

  1. To prevent the destruction of surge voltage, a varistor can be installed to the VFD input terminal, of which the withstand voltage should be lower than the voltage of power module to protect the components not being breakdown.
  2. Use a circuit breaker generated low surge voltage, as well as a varistor.
  3. When the transformer primary side is disconnected, VFD can be disconnected earlier by program control. At the same time, it also needs to be added the relevant varistor protection, through the excitation storage energy calculates resistance value. In addition, main circuit should use special arrester and fuse.

At the same time, VFD is generally equipped with lightning absorption network, mainly to prevent instantaneous lightning intrusion and causing damage. In the actual operation, especially in the case of the power cord overhead, the absorption network alone cannot meet the requirements. In lightning areas, this problem is particularly important. If the power cord is overhead, VFD should install with dedicated lightning arrester at the power wire, or according to specifications bury steel pipe for special ground protection in the distance 20m away from VFD. If the power supply is cable introduction, should manage the control room lightning protection system to prevent lightning damaging equipment.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
200 hp VFD output
5
Christina
Avatar
4/1/2021 7:11 PM
How clean is the output of your 200 hp VFD?
Was this review helpful? Yes No (0/0)
ATO Responded
200 hp VFD output is pulse width modulation wave (square).
Modbus protocol of VFD
5
Dvice
Avatar
12/17/2021 12:38 AM
I would like to know if the 1 phase to 1 phase smallest VFD comes with Modbus RTU protocol.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, and all our VFDs have Modbus RTU protocol.
Questions about VFD
5
Janr
Avatar
12/28/2021 1:30 AM
Do I need an additional relay to use with the VFD or can I wire it directly to the motor?
Was this review helpful? Yes No (0/0)
ATO Responded
Wire it directly to the motor.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

200 hp VFD, 160 kW high quality three phase 240V, 420V, 480V variable frequency drive.

Specification:

BasicsModelGK3000-4T1600G/ GK3000-2T1600G
Capacity200 hp (160 kW)
Shipping weight90 kg
Dimension760*390*320 mm
I/O FeatureRated current304A at 380V ~ 480V, 585A at 220V ~ 240V
Input voltageThree phase 240V /420V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltageThree phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150 % of rated current for 1 minute, 200 % of rated current for 1 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive lightning protection measures

  1. To prevent the destruction of surge voltage, a varistor can be installed to the VFD input terminal, of which the withstand voltage should be lower than the voltage of power module to protect the components not being breakdown.
  2. Use a circuit breaker generated low surge voltage, as well as a varistor.
  3. When the transformer primary side is disconnected, VFD can be disconnected earlier by program control. At the same time, it also needs to be added the relevant varistor protection, through the excitation storage energy calculates resistance value. In addition, main circuit should use special arrester and fuse.

At the same time, VFD is generally equipped with lightning absorption network, mainly to prevent instantaneous lightning intrusion and causing damage. In the actual operation, especially in the case of the power cord overhead, the absorption network alone cannot meet the requirements. In lightning areas, this problem is particularly important. If the power cord is overhead, VFD should install with dedicated lightning arrester at the power wire, or according to specifications bury steel pipe for special ground protection in the distance 20m away from VFD. If the power supply is cable introduction, should manage the control room lightning protection system to prevent lightning damaging equipment.

Product reviews
200 hp VFD output
5
Christina
Avatar
4/1/2021 7:11 PM
How clean is the output of your 200 hp VFD?
Was this review helpful? Yes No (0/0)
ATO Responded
200 hp VFD output is pulse width modulation wave (square).
Modbus protocol of VFD
5
Dvice
Avatar
12/17/2021 12:38 AM
I would like to know if the 1 phase to 1 phase smallest VFD comes with Modbus RTU protocol.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, and all our VFDs have Modbus RTU protocol.
Questions about VFD
5
Janr
Avatar
12/28/2021 1:30 AM
Do I need an additional relay to use with the VFD or can I wire it directly to the motor?
Was this review helpful? Yes No (0/0)
ATO Responded
Wire it directly to the motor.
Only registered users can write reviews
Customers who bought this item also bought

40 hp (30 kW) Soft starter, 60 A, 3ph 220v/380v/480v

GS-030
$449.20
Cheap price 40 hp soft starter for sale, 30 kW three phase 220v, 380v, 480v AC motor soft starter for choice, make motor in soft start & soft stop, buy from manufacturer directly.

10 kVA Isolation Transformer, 3 phase, 400 Volt to 240 Volt

ATO-T-SG10KVA
$2,635.71
Safety 10 kVA isolation transformer is suitable for circuit of 50 or 60Hz, 3 phase, primary voltage 400V to secondary voltage 240V. The transformers is high quality with lower cost, manufactured direct sale and fully compliant with reduced low voltage regulations.

10 hp (7.5 kW) Soft starter, 15 A, 3ph 220v/400v/480v

GS-7d5
$352.31
Favorable price 10 hp soft starter, 7.5 kW 3 phase 220v, 400v, 480v electric motor soft starts, make motor in soft start & soft stop, direct sale from manufacturer.