7.5 hp (5.5 kW) VFD, 3 Phase 208V, 380V, 480V

$415.08
7.5 hp (5.5 kW) VFD with wholesale price, 3 phase 208V/380V/480V 50Hz/60Hz for option, heavy duty variable frequency drive, 13 amps at 380V ~480V, strong overload capacity, manufacturer direct sale.
SKU: GK3000-4T0055G
Availability: In stock
Free Shipping
Delivery date: 2-3 days

7.5 hp heavy duty variable frequency drive, three phase 50Hz/60Hz 208V /380V /480V ±15%, brand new direct sale by manufacturer.

Specification:

BasicsModelGK3000-4T0055G/ GK3000-2T0055G
Capacity7.5 hp (5.5 kW)
Shipping weight5 kg
Dimension272*172*182 mm for GK3000-4T0055G/ 330*200*200 mm for GK3000-2T0055G
I/O FeatureRated current13A at 380V ~ 480V, 25A at 220V ~ 240V
Input voltage3 phase 208V /380V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive fault static test method
For a faulty VFD, power off the device and test its rectification and inversion part, in most cases the fault can be found this way. Pay attention that VFD cannot be measured immediately after power off, because there are large capacitors store with hundreds of volts of high voltage. The testing only can be launched more than ten minutes later. In order ensure personal safety, the operator must ensure that the machine is off, and the power input lines R/S/T and output lines U/V/W are removed.
Static test method
First turn the multimeter to "diode", and then use the multimeter's red and black pens to detect according to the following steps:

  1. Use black pen to touch the DC bus P (+), and the red pen touch R/S/T in turn, record the displayed values; and then the red pen touch N (-), black pen touch R/S/T, record the displayed values. If the six displayed values are balance, then the VFD diode rectifier or soft start resistance have no problem, otherwise the rectifier module or soft start resistance from the corresponding position is damaged.
  2. Use red pen touch the DC bus P (+), and the black pen touch U/V/W in turn, record the displayed values; and then the black pen touch N (-), red pen touch U/V/W, record the displayed values. If the six displayed values are balance, then the IGBT inverter module has no problem, otherwise the IGBT inverter module of the corresponding location is damaged.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
Fast receipt of 7.5 hp VFD
5
Hubert
Avatar
4/21/2021 8:15 PM
I will be visiting a friend in Chicago from April 5th to 10th. Will I be able to receive this 7.5hp VFD next week?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can. Just place an order online via a credit card and then confirm it again, which can save a lot of time.
7.5 hp VFD questions and answers
5
Sadie
Avatar
9/8/2021 12:44 AM
Hello, I live in French polynesia. Here we have 220 v (60hz) between 1 phase and 1 neutral: L N. As I see in the manual, your 1 phase 220v is between 2 phases: L1 L2. Do you have some VFD available for 1phase   1 neutral 220v input? My goal is to buy a 3 phases 220v air compressor (5 hp) in the USA, so I need a VFD TO CONVERT my 220v (1 phase   1 neutral) to a 3 phases 220v and for soft start too.
Maybe a 7.5HP VFD will be better for my 5 hp air compressor.
Thank you for your help.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Our 1-phase to 3-phase drive will cover your needs, as its input is 1-phase + 1 neutral 220V basically, and it works for 2-phase input (L1+L2, G) as well.
2. Yes, if your 3-phase, 220/230V motor rated current is less than 19A, then you can use our 7.5hp 1-phase to 3-phase drive. >> Model: GK3000-2S0055G
See specs, price, and you can order online by credit card at: https://www.ato.com/7-5hp-single-phase-to-three-phase-vfd
The panel providing power to the 7.5 hp VFD
5
niki
Avatar
6/6/2023 7:06 PM
The panel providing power to the VFD is fed by an American rotary phase converter. In normal operation, the power is A phase 120 to ground, B phase 120 to ground, C phase 240 to ground. A to B 240, B to C 240, A to C 240.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry for the late response.
So you are saying that although the three-phase 240V power output from the American rotary phase converter, C is relatively high, the three-phase voltages A, B, and C at the output end are all 240V, right?
If so, you can only connect the three-phase 240V power supply, first start the VFD with no load and then check whether the VFD can start up to 60HZ normally.  Then use a multimeter to continuously measure the voltage at the VFD input terminal to see if there is any change or fluctuation.
It would be better if you could provide us with a video for confirmation, the video should include the continuous measurement of the voltage at the VFD input terminal, and the running status displayed on the LCD panel.
You can send us the large video file via wetransfer.com.  Thank you for your understanding.
VFD video has been sent
5
paddy
Avatar
6/15/2023 3:21 AM
Video was sent at 6:25 pm mountain time on wetransfer.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for your feedback.
We reviewed the video you gave us feedback.    
We noticed that your three-phase 240V voltage is unbalanced,  one of the phases has a high voltage, and the highest voltage reaches 263V. We suggest that you remove the high phase C and use single-phase 240V voltage input to VFD instead. Our VFD can also receive single-phase 240V voltage, but the difference is that the current at the input terminal will increase, which is about 1.5 times the current at the output terminal.  
Regarding the reverse rotation of the motor, you need to set P3.46=031 (the ones digit is 1), and P0.04=00 (reverse rotation is allowed).
Hope my explanation is able to assist you.
Please feel free to let us know if you have any further questions.
Remote function
5
Katie
Avatar
3/31/2025 7:34 PM
Could you please tell me if this VFD has remote function? If so, which two terminals on the circuit board should I connect?
Was this review helpful? Yes No (0/0)
ATO Responded
Our VFD can be remotely controlled through external terminals, you can refer to the terminal control in the manual quick setup guide.
External Potentiometer
4
Schulich
Avatar
1/6/2026 11:35 PM
After configuring the VFD, do I need an external potentiometer? If so, how do I wire it?
Was this review helpful? Yes No (0/0)
ATO Responded
You can add an external potentiometer, or not. Please refer to the video example for wiring instructions: https://www.youtube.com/watch?v=Wkb9s5Q19pA&list=PLlo8RulDRnthB_yJeKHLcVVbUFz2r9ked&index=17
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

7.5 hp heavy duty variable frequency drive, three phase 50Hz/60Hz 208V /380V /480V ±15%, brand new direct sale by manufacturer.

Specification:

BasicsModelGK3000-4T0055G/ GK3000-2T0055G
Capacity7.5 hp (5.5 kW)
Shipping weight5 kg
Dimension272*172*182 mm for GK3000-4T0055G/ 330*200*200 mm for GK3000-2T0055G
I/O FeatureRated current13A at 380V ~ 480V, 25A at 220V ~ 240V
Input voltage3 phase 208V /380V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive fault static test method
For a faulty VFD, power off the device and test its rectification and inversion part, in most cases the fault can be found this way. Pay attention that VFD cannot be measured immediately after power off, because there are large capacitors store with hundreds of volts of high voltage. The testing only can be launched more than ten minutes later. In order ensure personal safety, the operator must ensure that the machine is off, and the power input lines R/S/T and output lines U/V/W are removed.
Static test method
First turn the multimeter to "diode", and then use the multimeter's red and black pens to detect according to the following steps:

  1. Use black pen to touch the DC bus P (+), and the red pen touch R/S/T in turn, record the displayed values; and then the red pen touch N (-), black pen touch R/S/T, record the displayed values. If the six displayed values are balance, then the VFD diode rectifier or soft start resistance have no problem, otherwise the rectifier module or soft start resistance from the corresponding position is damaged.
  2. Use red pen touch the DC bus P (+), and the black pen touch U/V/W in turn, record the displayed values; and then the black pen touch N (-), red pen touch U/V/W, record the displayed values. If the six displayed values are balance, then the IGBT inverter module has no problem, otherwise the IGBT inverter module of the corresponding location is damaged.
Product reviews
Fast receipt of 7.5 hp VFD
5
Hubert
Avatar
4/21/2021 8:15 PM
I will be visiting a friend in Chicago from April 5th to 10th. Will I be able to receive this 7.5hp VFD next week?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can. Just place an order online via a credit card and then confirm it again, which can save a lot of time.
7.5 hp VFD questions and answers
5
Sadie
Avatar
9/8/2021 12:44 AM
Hello, I live in French polynesia. Here we have 220 v (60hz) between 1 phase and 1 neutral: L N. As I see in the manual, your 1 phase 220v is between 2 phases: L1 L2. Do you have some VFD available for 1phase   1 neutral 220v input? My goal is to buy a 3 phases 220v air compressor (5 hp) in the USA, so I need a VFD TO CONVERT my 220v (1 phase   1 neutral) to a 3 phases 220v and for soft start too.
Maybe a 7.5HP VFD will be better for my 5 hp air compressor.
Thank you for your help.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Our 1-phase to 3-phase drive will cover your needs, as its input is 1-phase + 1 neutral 220V basically, and it works for 2-phase input (L1+L2, G) as well.
2. Yes, if your 3-phase, 220/230V motor rated current is less than 19A, then you can use our 7.5hp 1-phase to 3-phase drive. >> Model: GK3000-2S0055G
See specs, price, and you can order online by credit card at: https://www.ato.com/7-5hp-single-phase-to-three-phase-vfd
The panel providing power to the 7.5 hp VFD
5
niki
Avatar
6/6/2023 7:06 PM
The panel providing power to the VFD is fed by an American rotary phase converter. In normal operation, the power is A phase 120 to ground, B phase 120 to ground, C phase 240 to ground. A to B 240, B to C 240, A to C 240.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry for the late response.
So you are saying that although the three-phase 240V power output from the American rotary phase converter, C is relatively high, the three-phase voltages A, B, and C at the output end are all 240V, right?
If so, you can only connect the three-phase 240V power supply, first start the VFD with no load and then check whether the VFD can start up to 60HZ normally.  Then use a multimeter to continuously measure the voltage at the VFD input terminal to see if there is any change or fluctuation.
It would be better if you could provide us with a video for confirmation, the video should include the continuous measurement of the voltage at the VFD input terminal, and the running status displayed on the LCD panel.
You can send us the large video file via wetransfer.com.  Thank you for your understanding.
VFD video has been sent
5
paddy
Avatar
6/15/2023 3:21 AM
Video was sent at 6:25 pm mountain time on wetransfer.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for your feedback.
We reviewed the video you gave us feedback.    
We noticed that your three-phase 240V voltage is unbalanced,  one of the phases has a high voltage, and the highest voltage reaches 263V. We suggest that you remove the high phase C and use single-phase 240V voltage input to VFD instead. Our VFD can also receive single-phase 240V voltage, but the difference is that the current at the input terminal will increase, which is about 1.5 times the current at the output terminal.  
Regarding the reverse rotation of the motor, you need to set P3.46=031 (the ones digit is 1), and P0.04=00 (reverse rotation is allowed).
Hope my explanation is able to assist you.
Please feel free to let us know if you have any further questions.
Remote function
5
Katie
Avatar
3/31/2025 7:34 PM
Could you please tell me if this VFD has remote function? If so, which two terminals on the circuit board should I connect?
Was this review helpful? Yes No (0/0)
ATO Responded
Our VFD can be remotely controlled through external terminals, you can refer to the terminal control in the manual quick setup guide.
External Potentiometer
4
Schulich
Avatar
1/6/2026 11:35 PM
After configuring the VFD, do I need an external potentiometer? If so, how do I wire it?
Was this review helpful? Yes No (0/0)
ATO Responded
You can add an external potentiometer, or not. Please refer to the video example for wiring instructions: https://www.youtube.com/watch?v=Wkb9s5Q19pA&list=PLlo8RulDRnthB_yJeKHLcVVbUFz2r9ked&index=17
Only registered users can write reviews
Customers who bought this item also bought

2 hp (1.5 kW) VFD, 3 Phase 240V, 415V, 480V

GK3000-4T0015G
$218.41
Cheap price 2 hp (1.5 kW) VFD, three phase 240V, 415V, 480V for choice, brand new sensorless vector variable frequency drive, RS485 enabled, strong overload capacity, manufacturer direct sale.

5 hp (3.7 kW) VFD, 3 Phase 230V, 400V, 480V

GK3000-4T0037G
$293.51
Favorable price 5 hp (3.7 / 4 kW) VFD, three phase 230V, 400V, 480V, high performance vector variable frequency drive, IP20 enclosure, RS485 enabled, brand new direct sale by manufacturer.

3 hp (2.2 kW) VFD, Three Phase 220V, 380V, 480V

GK3000-4T0022G
$280.48
Low cost 3 hp (2.2 kW) VFD, three phase 220V, 380V, 480V variable frequency drive, IP20 enclosure, RS485 enabled, V/F & vector control, brand new direct sale by manufacturer.

10 hp (7.5 kW) VFD, Three Phase 220V, 440V, 480V

GK3000-4T0075G
$463.25
Affordable 10 hp (7.5 kW) VFD, three phase 220V/440V/480V input for option, three phase output variable frequency drive, 17 amps, V/F & vector control, manufacturer direct sale.

30 hp (22 kW) VFD, 3 Phase 208V, 440V, 460V

GK3000-4T0220G
$1,264.30
Cheap price 30 hp (22 kW) VFD, three phase 208V, 440V, 460V high performance variable frequency drive, IP20, RS485 enabled, brand new direct sale by manufacturer.