3 hp (2.2 kW) VFD, Three Phase 220V, 380V, 480V

$280.48
Low cost 3 hp (2.2 kW) VFD, three phase 220V, 380V, 480V variable frequency drive, IP20 enclosure, RS485 enabled, V/F & vector control, brand new direct sale by manufacturer.
SKU: GK3000-4T0022G
Availability: In stock
Free Shipping
Delivery date: 2-3 days

3 hp 3 phase variable frequency drive, 220V, 380V, 480V for selection.

Specification:

BasicsModelGK3000-4T0022G/ GK3000-2T0022G
Capacity3 hp (2.2 kW)
Shipping weight3 kg
Dimension236*130*176 mm for GK3000-4T0022G/ 272*172*182 for GK3000-2T0022G
I/O FeatureRated current5.1A at 380V ~ 480V, 9A at 220V ~ 240V
Input voltage3 phase 220V /380V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

2200W Three Phase VFD Details

Tips: Variable frequency drive noise and vibration problems and solutions
When using VFD for speed adjusting, it will produce noise and vibration. This is because the VFD output waveform contains high harmonic wave. With the change of the operating frequency, the fundamental component and the harmonic component all change in a large range, which is likely to resonate with the inherent mechanical vibration of the motor, and the resonance is the source of noise and vibration.

  1. When the low harmonic wave components in the output resonate with the inherent mechanical frequency of the rotor, the noise will increases. When the high harmonic wave components in the output are resonated with the iron core, machine enclosure and bearing bracket at the vicinity of the respective natural frequencies, the noise will increases.
    The noise generated by the drive motor, especially the harsh noise, is related to the switching frequency of the PWM control, especially in the low frequency region. To solve this problem, usually connect AC reactor on the VFD output side. If there is electromagnetic torque margin, u/f can be set lower to reduce noise.
  2. When the VFD is in operation, the magnetic field caused by the higher harmonic wave in the output waveform generates electromagnetic driving force for many mechanical parts. When the driving force frequency is close or overlap with inherent frequency of these mechanical components, will resonate. The main effect on the vibration is the lower harmonic wave component, which has a greater impact in the PAM mode and square wave PWM mode. But when using SPWM mode, the low harmonic wave component is low, and the impact is also lower.
    The method of reducing or eliminating the vibration is to connect the AC reactor to the output side of the VFD to absorb the high harmonic current component. If still using PAM mode or square wave PWM mode VFD, switch to SPWM mode VFD to reduce pulsating torque, weaken or eliminate vibration, and to prevent the mechanical part damage due to vibration.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
Great VFD
5
Ken
Avatar
10/13/2017 12:36 AM
Unit arrived on time and as described.  It runs my 2hp milling machine very well. I'll be getting another VFD from you for my next piece of equipment.
Was this review helpful? Yes No (0/0)
Excellent value for the money
5
Jeremy
Avatar
3/5/2019 1:17 AM
Purchased three VFDs of 2.2kW power rating, excellent value for the money. I'm using one of these to drive a 3 hp 3 phase air compressor I picked up for my home shop. I deal with a lot of VFD's in my profession. I wouldn't specify it for a critical industrial application yet but for home use it seems to work well.
Was this review helpful? Yes No (0/0)
Technical info
5
Roberto
Avatar
2/6/2020 5:30 PM
Good day

I have a three phase motor that in the nameplate says 2 HP, 200-230 V, 7.6-7.8 Amps.

Do this vfd is enough to control that motor, cause in the table of this vfd say rated current 6A, or i need the 5Hp? i saw the 2HP and i have the same question.
For the motor i have which vfd is the correct one.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it's enough, you need to choose input voltage with 220v, which has rated current with 10A.
Questions about 3hp VFD
5
Suzie
Avatar
3/30/2021 7:13 PM
Can I get an Inverter to run a 480 Volt 3 Phase, 3 HP Motor on 208V, 3 Phase?
Was this review helpful? Yes No (0/0)
ATO Responded
No, the opposite is correct, the output voltage cannot be lower than input voltage.
3 hp VFD function explanation
5
nikos
Avatar
2/6/2023 1:33 AM
Kindly explain to me.
P0.04: The explanation is not very clear. I want to set reverse prohibited.
PA.00: What is this function for? Do I need to set it  up too?
Was this review helpful? Yes No (0/0)
ATO Responded
1. PA.00 is the motor parameter self-learning function, which generally does not need to be set.
You only need to refer to the quick setup document we sent before, set the basic parameters of VFD and you can use it.
2. P0.04 This is the running direction setting of the three-phase motor.
If you want the motor to allow reverse rotation, set P0.04=00 (the motor rotates forward and reverse rotation is allowed), and set P0.04=01 (the motor rotates reverse and reverse rotation is allowed).
Whether the water ingress damaged the 3 hp VFD?
5
kamran
Avatar
4/5/2023 8:18 PM
I received our order for the VFD and it arrived wet and damaged, see attached pictures.  What can be done to rectify this issue although the damage (external) is cosmetic. And the concern is whether the water ingress damaged the system.  
I can test it by installing the VDF and programming it to check functions that need your approval, please.  Or is it better to send a new unit?
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend that you first install VDF for testing and programming.
If the VFD is working properly, we can send you a fan shroud for replacement.
You can refer to the attached VFD parameter settings
If there is a problem with the VFD test, please provide the VFD nameplate label and video to us for confirmation.
Note: Before power-on test, please disassemble the case and blow it with a fan. You must first confirm that there is no water inside, and then power on the test.
Is it possible to unify them to control via one main VFD?
5
Hacoy
Avatar
8/10/2023 3:13 AM
We have a question about this VFD. We are looking to control 7 exhaust fans via VFD. Is it possible to unify them to control via one main VFD?
Was this review helpful? Yes No (0/0)
ATO Responded
We do not recommend controlling more than 4 motors at the same time.
VFD dial changing
5
reut
Avatar
8/30/2023 3:20 AM
How can I make it so the dial always increments 0.1 and does not start changing by 1 and 10?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, the potentiometer on the operation panel cannot adjust the frequency with an accuracy of 0.1Hz.
Remote Alarm Reset
5
Luis
Avatar
11/15/2023 10:42 AM
Can I do a remote alarm reset using a dry contact?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can customize the port with a VFD and define it as an external reset input to do what you want.
Good Quality VFD
4
Rako
Avatar
6/12/2024 3:12 AM
The flow rate of the centrifugal pump I use for fish farming is always unstable, so I bought this 3hp VFD. I want to adjust the speed of the centrifugal pump to better control the flow rate and head. I have considered the compatibility of the inverter and the centrifugal pump but encountered problems during the setting process. I am setting up a 3hp, 3-phase VFD for a constant pressure setup. I am getting an alarm (E-39). I don't know how to solve this E-39 problem.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Error 39 occurs because the motor frequency is lower than the sleep frequency during constant pressure water supply.
2. You can refer to our quick setup manual (P10.P11) for settings. Regarding the settings of the VFD, you can refer to this manual for instructions. See on: https://www.ato.com/Content/doc/gk3000-series-vfd-quick-set-user-manual.pdf
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

3 hp 3 phase variable frequency drive, 220V, 380V, 480V for selection.

Specification:

BasicsModelGK3000-4T0022G/ GK3000-2T0022G
Capacity3 hp (2.2 kW)
Shipping weight3 kg
Dimension236*130*176 mm for GK3000-4T0022G/ 272*172*182 for GK3000-2T0022G
I/O FeatureRated current5.1A at 380V ~ 480V, 9A at 220V ~ 240V
Input voltage3 phase 220V /380V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

2200W Three Phase VFD Details

Tips: Variable frequency drive noise and vibration problems and solutions
When using VFD for speed adjusting, it will produce noise and vibration. This is because the VFD output waveform contains high harmonic wave. With the change of the operating frequency, the fundamental component and the harmonic component all change in a large range, which is likely to resonate with the inherent mechanical vibration of the motor, and the resonance is the source of noise and vibration.

  1. When the low harmonic wave components in the output resonate with the inherent mechanical frequency of the rotor, the noise will increases. When the high harmonic wave components in the output are resonated with the iron core, machine enclosure and bearing bracket at the vicinity of the respective natural frequencies, the noise will increases.
    The noise generated by the drive motor, especially the harsh noise, is related to the switching frequency of the PWM control, especially in the low frequency region. To solve this problem, usually connect AC reactor on the VFD output side. If there is electromagnetic torque margin, u/f can be set lower to reduce noise.
  2. When the VFD is in operation, the magnetic field caused by the higher harmonic wave in the output waveform generates electromagnetic driving force for many mechanical parts. When the driving force frequency is close or overlap with inherent frequency of these mechanical components, will resonate. The main effect on the vibration is the lower harmonic wave component, which has a greater impact in the PAM mode and square wave PWM mode. But when using SPWM mode, the low harmonic wave component is low, and the impact is also lower.
    The method of reducing or eliminating the vibration is to connect the AC reactor to the output side of the VFD to absorb the high harmonic current component. If still using PAM mode or square wave PWM mode VFD, switch to SPWM mode VFD to reduce pulsating torque, weaken or eliminate vibration, and to prevent the mechanical part damage due to vibration.
Product reviews
Great VFD
5
Ken
Avatar
10/13/2017 12:36 AM
Unit arrived on time and as described.  It runs my 2hp milling machine very well. I'll be getting another VFD from you for my next piece of equipment.
Was this review helpful? Yes No (0/0)
Excellent value for the money
5
Jeremy
Avatar
3/5/2019 1:17 AM
Purchased three VFDs of 2.2kW power rating, excellent value for the money. I'm using one of these to drive a 3 hp 3 phase air compressor I picked up for my home shop. I deal with a lot of VFD's in my profession. I wouldn't specify it for a critical industrial application yet but for home use it seems to work well.
Was this review helpful? Yes No (0/0)
Technical info
5
Roberto
Avatar
2/6/2020 5:30 PM
Good day

I have a three phase motor that in the nameplate says 2 HP, 200-230 V, 7.6-7.8 Amps.

Do this vfd is enough to control that motor, cause in the table of this vfd say rated current 6A, or i need the 5Hp? i saw the 2HP and i have the same question.
For the motor i have which vfd is the correct one.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it's enough, you need to choose input voltage with 220v, which has rated current with 10A.
Questions about 3hp VFD
5
Suzie
Avatar
3/30/2021 7:13 PM
Can I get an Inverter to run a 480 Volt 3 Phase, 3 HP Motor on 208V, 3 Phase?
Was this review helpful? Yes No (0/0)
ATO Responded
No, the opposite is correct, the output voltage cannot be lower than input voltage.
3 hp VFD function explanation
5
nikos
Avatar
2/6/2023 1:33 AM
Kindly explain to me.
P0.04: The explanation is not very clear. I want to set reverse prohibited.
PA.00: What is this function for? Do I need to set it  up too?
Was this review helpful? Yes No (0/0)
ATO Responded
1. PA.00 is the motor parameter self-learning function, which generally does not need to be set.
You only need to refer to the quick setup document we sent before, set the basic parameters of VFD and you can use it.
2. P0.04 This is the running direction setting of the three-phase motor.
If you want the motor to allow reverse rotation, set P0.04=00 (the motor rotates forward and reverse rotation is allowed), and set P0.04=01 (the motor rotates reverse and reverse rotation is allowed).
Whether the water ingress damaged the 3 hp VFD?
5
kamran
Avatar
4/5/2023 8:18 PM
I received our order for the VFD and it arrived wet and damaged, see attached pictures.  What can be done to rectify this issue although the damage (external) is cosmetic. And the concern is whether the water ingress damaged the system.  
I can test it by installing the VDF and programming it to check functions that need your approval, please.  Or is it better to send a new unit?
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend that you first install VDF for testing and programming.
If the VFD is working properly, we can send you a fan shroud for replacement.
You can refer to the attached VFD parameter settings
If there is a problem with the VFD test, please provide the VFD nameplate label and video to us for confirmation.
Note: Before power-on test, please disassemble the case and blow it with a fan. You must first confirm that there is no water inside, and then power on the test.
Is it possible to unify them to control via one main VFD?
5
Hacoy
Avatar
8/10/2023 3:13 AM
We have a question about this VFD. We are looking to control 7 exhaust fans via VFD. Is it possible to unify them to control via one main VFD?
Was this review helpful? Yes No (0/0)
ATO Responded
We do not recommend controlling more than 4 motors at the same time.
VFD dial changing
5
reut
Avatar
8/30/2023 3:20 AM
How can I make it so the dial always increments 0.1 and does not start changing by 1 and 10?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, the potentiometer on the operation panel cannot adjust the frequency with an accuracy of 0.1Hz.
Remote Alarm Reset
5
Luis
Avatar
11/15/2023 10:42 AM
Can I do a remote alarm reset using a dry contact?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can customize the port with a VFD and define it as an external reset input to do what you want.
Good Quality VFD
4
Rako
Avatar
6/12/2024 3:12 AM
The flow rate of the centrifugal pump I use for fish farming is always unstable, so I bought this 3hp VFD. I want to adjust the speed of the centrifugal pump to better control the flow rate and head. I have considered the compatibility of the inverter and the centrifugal pump but encountered problems during the setting process. I am setting up a 3hp, 3-phase VFD for a constant pressure setup. I am getting an alarm (E-39). I don't know how to solve this E-39 problem.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Error 39 occurs because the motor frequency is lower than the sleep frequency during constant pressure water supply.
2. You can refer to our quick setup manual (P10.P11) for settings. Regarding the settings of the VFD, you can refer to this manual for instructions. See on: https://www.ato.com/Content/doc/gk3000-series-vfd-quick-set-user-manual.pdf
Only registered users can write reviews
Customers who bought this item also bought

2 hp (1.5 kW) VFD, 3 Phase 240V, 415V, 480V

GK3000-4T0015G
$218.41
Cheap price 2 hp (1.5 kW) VFD, three phase 240V, 415V, 480V for choice, brand new sensorless vector variable frequency drive, RS485 enabled, strong overload capacity, manufacturer direct sale.

5 hp (3.7 kW) VFD, 3 Phase 230V, 400V, 480V

GK3000-4T0037G
$293.51
Favorable price 5 hp (3.7 / 4 kW) VFD, three phase 230V, 400V, 480V, high performance vector variable frequency drive, IP20 enclosure, RS485 enabled, brand new direct sale by manufacturer.

7.5 hp (5.5 kW) VFD, 3 Phase 208V, 380V, 480V

GK3000-4T0055G
$415.08
7.5 hp (5.5 kW) VFD with wholesale price, 3 phase 208V/380V/480V 50Hz/60Hz for option, heavy duty variable frequency drive, 13 amps at 380V ~480V, strong overload capacity, manufacturer direct sale.

10 hp (7.5 kW) VFD, Three Phase 220V, 440V, 480V

GK3000-4T0075G
$463.25
Affordable 10 hp (7.5 kW) VFD, three phase 220V/440V/480V input for option, three phase output variable frequency drive, 17 amps, V/F & vector control, manufacturer direct sale.

Pressure Transducer for Air/Water/Oil, Output 4-20mA/0-10V/RS485

ATO-PRES-P400
$149.96
Pressure transducer offers selectable ranges from -0.1 to 60 MPa and supports current, voltage or RS485 signal output. The 2088-style housing is designed for air, water and oil pressure measurement at medium temperatures from -40°C to 60°C.