30 hp (22 kW) VFD, 3 Phase 208V, 440V, 460V

$1,264.30
Cheap price 30 hp (22 kW) VFD, three phase 208V, 440V, 460V high performance variable frequency drive, IP20, RS485 enabled, brand new direct sale by manufacturer.
SKU: GK3000-4T0220G
Free Shipping
Delivery date: 6-12 days

30 hp (22 kW) high performance variable frequency drive, three phase 208V, 440V, 460V for selection, manufacturer direct sale.

Specification:

BasicsModelGK3000-4T0220G/ GK3000-2T0220G
Capacity30 hp (22 kW)
Shipping weight8 kg
Dimension330*200*200 mm for GK3000-4T0220G/ 555*310*260 for GK3000-2T0220G
I/O FeatureRated current45A at 380V ~ 480V, 91A at 220V ~ 240V
Input voltage3 phase 208V /440V /460V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the debate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive overheated
Overheating is also a relatively common failure of VFD, which is mainly caused by high environment temperature, fan locked-rotor, poor temperature sensor performance or motor overheating.
For example, a 30 hp VFD displays "OH" after running for about half an hour.
Analysis and maintenance: Because the failure happens after a period of running, so the temperature sensor is not likely to be broken. Maybe VFD temperature is truly high. After power on, find the fan is slowly rotating, and there is a lot of cotton inside the shield (VFD is used in the textile industry). After cleaning the fan, VFD runs well, and doesn't display the failure for hours of running.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
3 phase vfd can be run CNC spindle motors?
5
Kennedy
Avatar
8/1/2021 9:55 PM
My supply voltage is 3 phase, 480V, can I use your 3 phase drive, and adjust its output to 380V, 400Hz to run my CNC spindle motor?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course.
What is the best way to set up the parameters for the motor I have installed in the system?
5
Abys
Avatar
8/11/2023 12:19 AM
I am not using the displayed numbers. I have attached a True RMS and an RMS clip-on ampere meter to both the input and out terminals. The difference between the True RMS and RMS meters on the input terminal is about 1.5, which makes sense since you are assuming a 1.5 delta between the numbers. One thing both meters agree on is the output of the VFD. They both agree the ampere's read there are just about 30 AMPs. This does not change much if there is a load or not, which surprised me. What surprises me is when there are no restrictions to the flow of water through the pump, the amperes are really high on the input side. Yet when I constrict the flow, the input amps drop like a rock. I would have thought the amps would be greater with a restriction since the pump needs to work harder to push the water. But I'm wrong. What is the best way to set up the parameters for the motor I have installed in the system? Should I peck in the configuration information, or does the Senseless Vector control perform the best?
Was this review helpful? Yes No (0/0)
ATO Responded
Please do not worry, we think your VFD is working fine. In fact, the current output by the VFD is related to the operating load capacity of the pump: when you do not limit the flow, the pump needs to run at full speed, and the load is larger, and the relative current is larger. Conversely, when the pump is limiting flow, the pump does not need to run at full speed to reach the target water flow, and the current is relatively low, which is normal. Now you just need to change the circuit breaker on the input side of the VFD to a larger capacity 80A. VFD does not need to set motor parameters.
A series of question about VFD
5
Colin
Avatar
10/23/2023 9:36 PM
can the VFD start normally after removing the motor?
After the VFD displays the E09 fault, please click the shift key on the panel >> to switch to b-12. What is the current value displayed by b-12 in A?
The VFD does not display E09 fault
The VFD starts, the motor turns and tightens up the chains and then stops, will NOT drive the chains with a load on them
The drive does not fault, it just sits there trying
You can tell the motor is trying to move, it maintains tension on the chain but will not move it
If you stop the VFD, the chain gets loose again
That is all the info available
Was this review helpful? Yes No (0/0)
ATO Responded
Based on your description, we think the 30HP VFD should be overloaded, because after removing the motor, it can run normally without load.

Therefore, the chain connected to the motor should be a heavy load.
In order to verify this problem, you can ask your customer to remove the chain on the motor, remove the tension, and then VFD and motor again to check whether the 30HP motor can run without load?

If the motor can run without load, it means that the load of the chain is very large and the VFD is overloaded.
We are encountering a voltage issue with the inverter
5
Remy
Avatar
11/14/2024 11:47 PM
We purchased a 22kW voltage/frequency inverter a couple months back. We are encountering a voltage issue with the inverter. A 208V-380V step-up transformer is connected to the inverter, where the inverter would then connect directly into a 3 phase cycler. We confirmed the transformer's output (~380V) and the building panel's ~208V service voltage are correct.
However, when the inverter is powered on, it shows an output voltage of 522-535V, instead of the expected 380V. We’ve adjusted the voltage and frequency parameters to 380V, 50Hz, but the high voltage remains.
We would greatly appreciate your guidance on troubleshooting steps. Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
When the inverter is powered on, it shows an output voltage of 522-535V, which is the DC bus voltage.
When the VFD runs at 60HZ, you can click the switch key >> to switch the LCD panel to display the AC voltage AC380V.
Of course, you can also use a multimeter to directly measure the voltage of the VFD output terminals U, V, W to check whether the output voltage is normal or not.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

30 hp (22 kW) high performance variable frequency drive, three phase 208V, 440V, 460V for selection, manufacturer direct sale.

Specification:

BasicsModelGK3000-4T0220G/ GK3000-2T0220G
Capacity30 hp (22 kW)
Shipping weight8 kg
Dimension330*200*200 mm for GK3000-4T0220G/ 555*310*260 for GK3000-2T0220G
I/O FeatureRated current45A at 380V ~ 480V, 91A at 220V ~ 240V
Input voltage3 phase 208V /440V /460V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the debate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive overheated
Overheating is also a relatively common failure of VFD, which is mainly caused by high environment temperature, fan locked-rotor, poor temperature sensor performance or motor overheating.
For example, a 30 hp VFD displays "OH" after running for about half an hour.
Analysis and maintenance: Because the failure happens after a period of running, so the temperature sensor is not likely to be broken. Maybe VFD temperature is truly high. After power on, find the fan is slowly rotating, and there is a lot of cotton inside the shield (VFD is used in the textile industry). After cleaning the fan, VFD runs well, and doesn't display the failure for hours of running.

Product reviews
3 phase vfd can be run CNC spindle motors?
5
Kennedy
Avatar
8/1/2021 9:55 PM
My supply voltage is 3 phase, 480V, can I use your 3 phase drive, and adjust its output to 380V, 400Hz to run my CNC spindle motor?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course.
What is the best way to set up the parameters for the motor I have installed in the system?
5
Abys
Avatar
8/11/2023 12:19 AM
I am not using the displayed numbers. I have attached a True RMS and an RMS clip-on ampere meter to both the input and out terminals. The difference between the True RMS and RMS meters on the input terminal is about 1.5, which makes sense since you are assuming a 1.5 delta between the numbers. One thing both meters agree on is the output of the VFD. They both agree the ampere's read there are just about 30 AMPs. This does not change much if there is a load or not, which surprised me. What surprises me is when there are no restrictions to the flow of water through the pump, the amperes are really high on the input side. Yet when I constrict the flow, the input amps drop like a rock. I would have thought the amps would be greater with a restriction since the pump needs to work harder to push the water. But I'm wrong. What is the best way to set up the parameters for the motor I have installed in the system? Should I peck in the configuration information, or does the Senseless Vector control perform the best?
Was this review helpful? Yes No (0/0)
ATO Responded
Please do not worry, we think your VFD is working fine. In fact, the current output by the VFD is related to the operating load capacity of the pump: when you do not limit the flow, the pump needs to run at full speed, and the load is larger, and the relative current is larger. Conversely, when the pump is limiting flow, the pump does not need to run at full speed to reach the target water flow, and the current is relatively low, which is normal. Now you just need to change the circuit breaker on the input side of the VFD to a larger capacity 80A. VFD does not need to set motor parameters.
A series of question about VFD
5
Colin
Avatar
10/23/2023 9:36 PM
can the VFD start normally after removing the motor?
After the VFD displays the E09 fault, please click the shift key on the panel >> to switch to b-12. What is the current value displayed by b-12 in A?
The VFD does not display E09 fault
The VFD starts, the motor turns and tightens up the chains and then stops, will NOT drive the chains with a load on them
The drive does not fault, it just sits there trying
You can tell the motor is trying to move, it maintains tension on the chain but will not move it
If you stop the VFD, the chain gets loose again
That is all the info available
Was this review helpful? Yes No (0/0)
ATO Responded
Based on your description, we think the 30HP VFD should be overloaded, because after removing the motor, it can run normally without load.

Therefore, the chain connected to the motor should be a heavy load.
In order to verify this problem, you can ask your customer to remove the chain on the motor, remove the tension, and then VFD and motor again to check whether the 30HP motor can run without load?

If the motor can run without load, it means that the load of the chain is very large and the VFD is overloaded.
We are encountering a voltage issue with the inverter
5
Remy
Avatar
11/14/2024 11:47 PM
We purchased a 22kW voltage/frequency inverter a couple months back. We are encountering a voltage issue with the inverter. A 208V-380V step-up transformer is connected to the inverter, where the inverter would then connect directly into a 3 phase cycler. We confirmed the transformer's output (~380V) and the building panel's ~208V service voltage are correct.
However, when the inverter is powered on, it shows an output voltage of 522-535V, instead of the expected 380V. We’ve adjusted the voltage and frequency parameters to 380V, 50Hz, but the high voltage remains.
We would greatly appreciate your guidance on troubleshooting steps. Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
When the inverter is powered on, it shows an output voltage of 522-535V, which is the DC bus voltage.
When the VFD runs at 60HZ, you can click the switch key >> to switch the LCD panel to display the AC voltage AC380V.
Of course, you can also use a multimeter to directly measure the voltage of the VFD output terminals U, V, W to check whether the output voltage is normal or not.
Only registered users can write reviews
Customers who bought this item also bought

7.5 hp (5.5 kW) VFD, 3 Phase 208V, 380V, 480V

GK3000-4T0055G
$415.08
7.5 hp (5.5 kW) VFD with wholesale price, 3 phase 208V/380V/480V 50Hz/60Hz for option, heavy duty variable frequency drive, 13 amps at 380V ~480V, strong overload capacity, manufacturer direct sale.

25 hp (18.5 kW) VFD, 3 Phase 240V, 420V, 480V

GK3000-4T0185G
$992.18
Favorable price 25 hp (18.5 kW) VFD, three phase 240V, 420V, 480V variable frequency drive, IP20, RS485 enabled, brand new direct sale by Chinese manufacturer with wholesale price.

40 hp (30 kW) VFD, 3 Phase 230V, 420V, 480V

GK3000-4T0300G
$1,497.31
High quality 40 hp (30 kW) VFD with low cost, three phase 230V, 420V, 480V variable frequency drive with good performance, brand new direct sale by manufacturer.

5 hp (3.7 kW) VFD, 3 Phase 230V, 400V, 480V

GK3000-4T0037G
$293.51
Favorable price 5 hp (3.7 / 4 kW) VFD, three phase 230V, 400V, 480V, high performance vector variable frequency drive, IP20 enclosure, RS485 enabled, brand new direct sale by manufacturer.

HMI Touch Screen, 7 Inch, 800 x 480

ATO-HMI-7
$369.72
Low cost HMI touch scaeen for sale, manufacturer direct sales, 7 inch Human Machine Interface display touch screen, 800 x 480 pixels. HMI uses the latest Cortex-A8 / dual-core high-speed processor and a 65,536-color color LCD screen with high brightness and contrast, manufacturer direct sales.