10 hp (7.5 kW) VFD, Three Phase 220V, 440V, 480V

$463.25
Affordable 10 hp (7.5 kW) VFD, three phase 220V/440V/480V input for option, three phase output variable frequency drive, 17 amps, V/F & vector control, manufacturer direct sale.
SKU: GK3000-4T0075G
Free Shipping
Delivery date: 6-12 days

10 hp variable frequency drive, three phase 220V /440V /480V ±15%, IP20 enclosure.

Specification:

BasicsModelGK3000-4T0075G/ GK3000-2T0075G
Capacity10 hp (7.5 kW)
Shipping weight5 kg
Dimension272*172*182 mm for GK3000-4T0075G/ 330*200*200 for GK3000-2T0075G
I/O FeatureRated current17A at 380V ~ 480V, 32A at 220V ~ 240V
Input voltage3 phase 220V /440V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive fault dynamic test method
The dynamic test can only be proceeding after the static test result is normal. Dynamic testing must note the following issues:

  1. Before powering, the input voltage must be confirmed. If connect 380V power supply into 220V VFD, the VFD will be burned.
  2. Check all the connections of the VFD to be correct connected and fastened. Improper connection may lead to failure, or seriously, to be burned.
  3. After power on, check the failure display content, and initially determine the reasons.
  4. If the fault is not displayed, first check whether the parameters are abnormal, and then reset the parameters, and start VFD to test U/V/W three-phase output voltage under no-load situation.
  5. When the output voltage is normal and three-phase equilibrium, start load test. And it's best to start full load test.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
10 hp VFD related issues
5
Kunwoo
Avatar
6/14/2021 9:13 PM
We are interested in acquiring a 10 hp VFD but I have many questions. Do you have resellers in mexico? The VFD has a industrial certification?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Don't have re-seller in Mexico. But we ship To Mexico (by Air) free of charge.
2. Yes, CE certificate.
Suitable VFD recommended by ATO
5
Sandey
Avatar
9/22/2021 8:10 PM
The pump is a 60Hz, 17.3 kw, 440 v, 31.7A submersible pump, three-phase motor.
What is the right 1 to 3-phase converter for this pump? Pumping water 267 m up to a tank from a water source.
Was this review helpful? Yes No (0/0)
ATO Responded
We can customize required 1-phase, 240V to 3-phase, 440V VFD to run 31.7A submersible pump.
Recommend VFD capacity is 30hp (22kW), and model number is: GK3000-CS0220G. Its 240 input to 3-phase, 440V, output current 45A.
Hi ATO
5
Noam
Avatar
12/19/2022 9:57 PM
Hi, I have three phase motor, 7.5Hp, 11.8/20.4A, 380V, with 2800Rpm, is the GK3000-4T0075G will be good for the mission?
Was this review helpful? Yes No (0/0)
ATO Responded
We calculated from your motor power and voltage that the current of the matching VFD is 11.8A at 380V. So this 10 hp VFD (GK3000-4T0075G) meets your needs.
VFD parameter settings
5
carver
Avatar
7/20/2023 12:43 AM
I have powered up the drive with the spindle motor wired into it.
Started the drive the spindle motor and drive will go to about 25hz.
And won’t change when I increase or decrease the desired hz.
Setting it runs for about 30 seconds and faults out with E-10.
Can you help me out with a list of parameter settings that I will need to run the spindle motor in a normal run mode from the controller panel?
Was this review helpful? Yes No (0/0)
ATO Responded
What are the parameters you set?
Please set frequency parameters P0.06=300, P0.07=300, P0.19=300.
Have any suggestions for VFD code?
5
doro
Avatar
7/24/2023 2:02 AM
We are getting a random E-12 Error code on one of our VFDs
Model GK3000-4T0075G
The VFD is set for 14.9 RPM.
And is only drawing 3.7 -4.0 AMPS.
VFD is cool to the touch, not overheating.
Any suggestions?
Was this review helpful? Yes No (0/0)
ATO Responded
Regarding your VFD displaying E-12 Error, it may be due to instantaneous overcurrent during operation or a phase-to-phase short circuit of the motor circuit at the output end of the VFD.
You can refer to the attachment to set the VFD parameters.
Please set P0.22=2 or 3 (V/F curve setting.) P0.17=15 (Acc time.) P0.18=15 (Dec time.), and then run VFD with no load.
Please confirm whether the VFD can run normally up to 60HZ without load.
Then, please check whether there is a short circuit between the motor and the motor cable.
After confirming that there is no problem with the motor and the line, connect the motor to the U, VW terminals, and test again.
If there is still a problem, please provide us with a picture of the motor and VFD nameplate label and a video for further confirmation.
Thank you for your understanding.
You can send us the large video file via wetransfer.com.
VFD acceleration and deceleration setting
5
beck
Avatar
8/29/2023 12:10 AM
P0.12 and P0.13 are acceleration time and deceleration time.
We need to speed increase and decrease via terminals.
For example, please find the inverter we use in which terminals D13 and D14 allow for speed increase and decrease.
We will need to you if you have this option as I could find it in the manual you sent.
Was this review helpful? Yes No (0/0)
ATO Responded
This product can set function parameter X1 to set terminal acceleration and deceleration.
You can define one terminal to accelerate and one terminal to decelerate.
Please refer to parameters 6 and 7 of the manual P3.00.
Manual: https://www.ato.com/Content/doc/gk3000-variable-frequency-drive-user-manual.pdf
Video: https://www.youtube.com/watch?v=2NWEOwqSfr4&list=PLlo8RulDRnthB_yJeKHLcVVbUFz2r9ked&index=1
Programming Complexity
4
Oalliope
Avatar
11/23/2023 1:36 AM
While modern VFDs often come with user-friendly interfaces, programming the drive for specific applications may require a certain level of expertise. Adequate training or consultation with technical support may be necessary for users less familiar with VFD programming.
Was this review helpful? Yes No (0/0)
Affordable and Reliable GK3000-4T0075G
5
Nick
Avatar
6/12/2024 10:12 AM
I have purchased six of these units over the past two years. They have held up great in the oil field where we run them on pump jacks. We have power issues in the field all the time like single phasing/ low voltage and lightning strikes and they almost always survive. Easy programming interface and fast technical support via email. About to buy two more!
Was this review helpful? Yes No (0/0)
I have a question
5
Masca
Avatar
8/27/2024 12:08 AM
I have question about a 7.5kw VFD. How long does an auto tune normally take? I have tried it on a couple of drives and it seems to run fine but doesn't stop.
Was this review helpful? Yes No (0/0)
ATO Responded
VFD self-adjusts and learns, which usually takes about 30 seconds. You need to set the motor parameter group P8.00-P8.5 according to the motor nameplate specifications, and then set P8.37=2 (2 asynchronous motor).
Buy a VFD
5
Pinole
Avatar
3/12/2025 2:34 AM
We need to purchase a 10 Hp, 575V, 9.6 amps, 1770 RPM VFD. Can you provide it?
Was this review helpful? Yes No (0/0)
ATO Responded
We are very sorry, but we are unable to provide a 575V high voltage VFD model. This high voltage is generally only used for customized large-capacity motors.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

10 hp variable frequency drive, three phase 220V /440V /480V ±15%, IP20 enclosure.

Specification:

BasicsModelGK3000-4T0075G/ GK3000-2T0075G
Capacity10 hp (7.5 kW)
Shipping weight5 kg
Dimension272*172*182 mm for GK3000-4T0075G/ 330*200*200 for GK3000-2T0075G
I/O FeatureRated current17A at 380V ~ 480V, 32A at 220V ~ 240V
Input voltage3 phase 220V /440V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive fault dynamic test method
The dynamic test can only be proceeding after the static test result is normal. Dynamic testing must note the following issues:

  1. Before powering, the input voltage must be confirmed. If connect 380V power supply into 220V VFD, the VFD will be burned.
  2. Check all the connections of the VFD to be correct connected and fastened. Improper connection may lead to failure, or seriously, to be burned.
  3. After power on, check the failure display content, and initially determine the reasons.
  4. If the fault is not displayed, first check whether the parameters are abnormal, and then reset the parameters, and start VFD to test U/V/W three-phase output voltage under no-load situation.
  5. When the output voltage is normal and three-phase equilibrium, start load test. And it's best to start full load test.
Product reviews
10 hp VFD related issues
5
Kunwoo
Avatar
6/14/2021 9:13 PM
We are interested in acquiring a 10 hp VFD but I have many questions. Do you have resellers in mexico? The VFD has a industrial certification?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Don't have re-seller in Mexico. But we ship To Mexico (by Air) free of charge.
2. Yes, CE certificate.
Suitable VFD recommended by ATO
5
Sandey
Avatar
9/22/2021 8:10 PM
The pump is a 60Hz, 17.3 kw, 440 v, 31.7A submersible pump, three-phase motor.
What is the right 1 to 3-phase converter for this pump? Pumping water 267 m up to a tank from a water source.
Was this review helpful? Yes No (0/0)
ATO Responded
We can customize required 1-phase, 240V to 3-phase, 440V VFD to run 31.7A submersible pump.
Recommend VFD capacity is 30hp (22kW), and model number is: GK3000-CS0220G. Its 240 input to 3-phase, 440V, output current 45A.
Hi ATO
5
Noam
Avatar
12/19/2022 9:57 PM
Hi, I have three phase motor, 7.5Hp, 11.8/20.4A, 380V, with 2800Rpm, is the GK3000-4T0075G will be good for the mission?
Was this review helpful? Yes No (0/0)
ATO Responded
We calculated from your motor power and voltage that the current of the matching VFD is 11.8A at 380V. So this 10 hp VFD (GK3000-4T0075G) meets your needs.
VFD parameter settings
5
carver
Avatar
7/20/2023 12:43 AM
I have powered up the drive with the spindle motor wired into it.
Started the drive the spindle motor and drive will go to about 25hz.
And won’t change when I increase or decrease the desired hz.
Setting it runs for about 30 seconds and faults out with E-10.
Can you help me out with a list of parameter settings that I will need to run the spindle motor in a normal run mode from the controller panel?
Was this review helpful? Yes No (0/0)
ATO Responded
What are the parameters you set?
Please set frequency parameters P0.06=300, P0.07=300, P0.19=300.
Have any suggestions for VFD code?
5
doro
Avatar
7/24/2023 2:02 AM
We are getting a random E-12 Error code on one of our VFDs
Model GK3000-4T0075G
The VFD is set for 14.9 RPM.
And is only drawing 3.7 -4.0 AMPS.
VFD is cool to the touch, not overheating.
Any suggestions?
Was this review helpful? Yes No (0/0)
ATO Responded
Regarding your VFD displaying E-12 Error, it may be due to instantaneous overcurrent during operation or a phase-to-phase short circuit of the motor circuit at the output end of the VFD.
You can refer to the attachment to set the VFD parameters.
Please set P0.22=2 or 3 (V/F curve setting.) P0.17=15 (Acc time.) P0.18=15 (Dec time.), and then run VFD with no load.
Please confirm whether the VFD can run normally up to 60HZ without load.
Then, please check whether there is a short circuit between the motor and the motor cable.
After confirming that there is no problem with the motor and the line, connect the motor to the U, VW terminals, and test again.
If there is still a problem, please provide us with a picture of the motor and VFD nameplate label and a video for further confirmation.
Thank you for your understanding.
You can send us the large video file via wetransfer.com.
VFD acceleration and deceleration setting
5
beck
Avatar
8/29/2023 12:10 AM
P0.12 and P0.13 are acceleration time and deceleration time.
We need to speed increase and decrease via terminals.
For example, please find the inverter we use in which terminals D13 and D14 allow for speed increase and decrease.
We will need to you if you have this option as I could find it in the manual you sent.
Was this review helpful? Yes No (0/0)
ATO Responded
This product can set function parameter X1 to set terminal acceleration and deceleration.
You can define one terminal to accelerate and one terminal to decelerate.
Please refer to parameters 6 and 7 of the manual P3.00.
Manual: https://www.ato.com/Content/doc/gk3000-variable-frequency-drive-user-manual.pdf
Video: https://www.youtube.com/watch?v=2NWEOwqSfr4&list=PLlo8RulDRnthB_yJeKHLcVVbUFz2r9ked&index=1
Programming Complexity
4
Oalliope
Avatar
11/23/2023 1:36 AM
While modern VFDs often come with user-friendly interfaces, programming the drive for specific applications may require a certain level of expertise. Adequate training or consultation with technical support may be necessary for users less familiar with VFD programming.
Was this review helpful? Yes No (0/0)
Affordable and Reliable GK3000-4T0075G
5
Nick
Avatar
6/12/2024 10:12 AM
I have purchased six of these units over the past two years. They have held up great in the oil field where we run them on pump jacks. We have power issues in the field all the time like single phasing/ low voltage and lightning strikes and they almost always survive. Easy programming interface and fast technical support via email. About to buy two more!
Was this review helpful? Yes No (0/0)
I have a question
5
Masca
Avatar
8/27/2024 12:08 AM
I have question about a 7.5kw VFD. How long does an auto tune normally take? I have tried it on a couple of drives and it seems to run fine but doesn't stop.
Was this review helpful? Yes No (0/0)
ATO Responded
VFD self-adjusts and learns, which usually takes about 30 seconds. You need to set the motor parameter group P8.00-P8.5 according to the motor nameplate specifications, and then set P8.37=2 (2 asynchronous motor).
Buy a VFD
5
Pinole
Avatar
3/12/2025 2:34 AM
We need to purchase a 10 Hp, 575V, 9.6 amps, 1770 RPM VFD. Can you provide it?
Was this review helpful? Yes No (0/0)
ATO Responded
We are very sorry, but we are unable to provide a 575V high voltage VFD model. This high voltage is generally only used for customized large-capacity motors.
Only registered users can write reviews
Customers who bought this item also bought

7.5 hp (5.5 kW) VFD, 3 Phase 208V, 380V, 480V

GK3000-4T0055G
$415.08
7.5 hp (5.5 kW) VFD with wholesale price, 3 phase 208V/380V/480V 50Hz/60Hz for option, heavy duty variable frequency drive, 13 amps at 380V ~480V, strong overload capacity, manufacturer direct sale.

4.5 kW Air Cooled CNC Spindle Motor, 18000 rpm, ER32

ATO-SPINDLE-A4500
$705.88
Hot sale 4.5kW air cooled spindle motor for CNC router with high speed of 18000 rpm, ER32 collet, 2.27 Nm holding torque, works at 380V AC 300Hz, 4pcs P4 grade ceramic ball bearings which improves the service life under high speed revolution.

30A 277V/ 480V Locking Plug, 4 Pole 5 Wire

ATO-L22-30
$81.27
30A electrical locking plug with 4 pole and 5 wire, 277V and480V rated voltage. It is made of high quality nylon and full copper. The dielectric voltage withstand is 18000V minimum. Male plug and female plug for your choices.

5 hp (3.7 kW) VFD, 3 Phase 230V, 400V, 480V

GK3000-4T0037G
$293.51
Favorable price 5 hp (3.7 / 4 kW) VFD, three phase 230V, 400V, 480V, high performance vector variable frequency drive, IP20 enclosure, RS485 enabled, brand new direct sale by manufacturer.

15 hp (11 kW) VFD, 3 Phase 230V, 415V, 480V

GK3000-4T0110G
$634.44
Inexpensive 15 hp (11 kW) VFD, three phase 230V/415V/480V, high performance variable frequency drive, IP20 enclosure, RS485 enabled, brand new direct sale by manufacturer in China.