5 hp (3.7 kW) VFD, 3 Phase 230V, 400V, 480V

$293.51
Favorable price 5 hp (3.7 / 4 kW) VFD, three phase 230V, 400V, 480V, high performance vector variable frequency drive, IP20 enclosure, RS485 enabled, brand new direct sale by manufacturer.
SKU: GK3000-4T0037G
Availability: In stock
Free Shipping
Delivery date: 2-3 days

5 hp (3.7/4 kW) variable frequency drive, three phase 230V, 400V, 480V for selection, manufacturer direct sale.
Specification:

BasicsModelGK3000-4T0037G/ GK3000-2T0037G
Capacity5 hp (3.7 kW)
Shipping weight3 kg
Dimension236*130*176 mm for GK3000-4T0037G/ 272*172*182 for GK3000-2T0037G
I/O FeatureRated current9A at 380V ~ 480V, 13A at 220V ~ 240V
Input voltage3 phase 230V /400V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the debate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

3700W Three Phase VFD Details

Tips: Variable Frequency Drive Overvoltage
Overvoltage alarm is generally present at downtime, the main reason is that the deceleration time is too short or the braking resistor and the braking unit are problematic. For example, a 5hp VFD displays "OU" when shutdown. Before repairing the VFD, should make sure the reason for "OU" alarm is what. Here is because during the VFD deceleration, the speed of the motor rotor winding cutting the rotation magnetic field becomes fast, the rotor electromotive force and current increases, so that the motor is in power generation state. The feedback energy flows to DC part through the diode, which connects in parallel with high-power switch tube in inverting part, and finally causes by DC bus voltage increase. So, should focus on checking the brake circuit. After measuring the discharge resistance, find there's no problem. In the measurement of the brake tube find it breakdown. Replace it and power on, even fast parking have no problem.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
Do you provide replacement parts?
5
Rklein
Avatar
7/20/2021 8:53 PM
Is it possible to order replacement part of aproduct purchased from you 2 years ago?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, sure. we provide the replacement parts.
VFD recommended by ATO
5
Reeve
Avatar
9/25/2021 7:34 PM
I am attaching you the details requested by you.
Ok, what is your 1-phase motor rated voltage and current?
230V, 1-Ph, 50Hz, 5 A. Motor Wattage: 1100 W
And what is your 1-phase supply voltage?
230 V, 1 ph supply available
Do let me know if you require any more details.
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, recommended VFD model: GK3000-1S0015, 2hp capacity.
See its specs/price, and you can order online by credit card at: https://www.ato.com/2hp-vfd-single-phase-input-output
3 questions about this VFD
5
Glack
Avatar
3/9/2023 11:13 PM
I am trying to get it to communicate vis Modbus RTU. I can read from the VFD but I can't write to it. These are the parameters I have set
P0.01 4
P0.02 0
P0.03 2
P0.06 70
P0.17 5
P0.18 5
P0.19 70
P3.09 163
P3.10 100
P4.00 11
P8.01 100
Do I have to have a jumper in place on the terminals for the VFD to run? Also, the LOCAL light is flashing on the front of the VFD, why? Do you have any ideas why I can't write to it?
Was this review helpful? Yes No (0/0)
ATO Responded
1. We confirm that the parameter settings of the VFD are correct. You don't need to set a jumper on the terminal to make the VFD run, but you have to send the run command to the VFD by writing the command. Also, you need to write the running frequency into the address 2001H, then you can run the VFD directly through 485 communication.
2. The LOCAL light on the front of the VFD is blinking, which means that the VFD is controlled to start and stop through 485 communication.
3. May I ask what type of controller you use to send the command 485 communication command? PC or PLC? You can refer to VFD's introduction to the RTU mode command (P167) in the attached manual.
We would like to alter the program of VFD
5
vikia
Avatar
7/17/2023 9:37 PM
We have a GK3000-4T0037G VFD.
We would like to alter the program so we can run at different speeds, but we are not sure how to do this.
Could you please follow up with some steps?
We looked through the manual but are still having trouble.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Please provide us with the order number to further confirm what product you purchased. We hope to provide you with better service.
2. Please refer to the quick setup manual and video to set up the inverter.
Manual: https://www.ato.com/Content/doc/VFD-quick-setup-manual-and-application.pdf
Video: https://www.youtube.com/watch?v=uZKsPgcB2a8&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=9
questions
5
Isaac
Avatar
11/23/2023 11:10 PM
We just received 6 new 5hp VFDs and installed them this weekend, we came in yesterday one AHU had a E-12 Failure on the drive, and Leg 1 is only putting out less than 50 Volts.
Was this review helpful? Yes No (0/0)
ATO Responded
Are the 6 VFDs you purchased connected to the Air Handling Unit?  Our VFD can only be connected to the motor, and it is Not recommended to connect to the AHU.
About the switch
4
Benlyon
Avatar
12/9/2024 12:14 AM
I have a 3.7kw vfd that I am using to control a three phase 4hp motor for a panel saw. I do not have 3 ph service thus the use of a VFD. The saw has a start stop switch that is not a push lock style and I would like to use the original switch as much as possible. Based on the quick start manual is seems I would need to use a push lock switch to do a remote start with three wire control. Is there another way to use a push button on/off (no locking switches) to control the saw? I am currently employing the P3 series commands with x1 programmed to start with a after market locking switch. Is there another way?
Was this review helpful? Yes No (0/0)
ATO Responded
You can try to set the parameters: P0.03=1,
P3.00=1 X1 start (normally open)
P3.01=3 X2 stop (normally open)
P3.14=3 (three-wire system)
P3.41=00010 (change the X2 terminal normally closed to normally open)
Please refer to the manual P3 parameter group: https://www.ato.com/Content/doc/gk3000-variable-frequency-drive-user-manual.pdf
High frequency operation
5
Kumire
Avatar
7/10/2025 8:59 PM
I want to drive a 1333hz motor. Does the driver support 16kHz PWM switching frequency operation under high current conditions?
Was this review helpful? Yes No (0/0)
ATO Responded
Our inverters usually cannot drive motors above 1000Hz and the operation is unstable. The frequency extension function is not supported. It does not support 16kHz PWM switching frequency under high current conditions, so it is not suitable for your application scenario.
Reverse connection not working
5
Keske
Avatar
7/2/2026 12:24 AM
I purchased a 5hp (3.7 kW) frequency converter, three-phase 230V input voltage (three-phase) ±15%: 240V SKU: GK3000-4T0037G. I have already connected it, but the reverse connection is not working. Can you help me?
Was this review helpful? Yes No (0/0)
ATO Responded
Are you saying the motor cannot reverse? You only need to swap any two of the three phases U, V, and W to reverse the motor, or you can reverse the motor using the REV button and setting parameter P7.00=5.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

5 hp (3.7/4 kW) variable frequency drive, three phase 230V, 400V, 480V for selection, manufacturer direct sale.
Specification:

BasicsModelGK3000-4T0037G/ GK3000-2T0037G
Capacity5 hp (3.7 kW)
Shipping weight3 kg
Dimension236*130*176 mm for GK3000-4T0037G/ 272*172*182 for GK3000-2T0037G
I/O FeatureRated current9A at 380V ~ 480V, 13A at 220V ~ 240V
Input voltage3 phase 230V /400V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the debate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

3700W Three Phase VFD Details

Tips: Variable Frequency Drive Overvoltage
Overvoltage alarm is generally present at downtime, the main reason is that the deceleration time is too short or the braking resistor and the braking unit are problematic. For example, a 5hp VFD displays "OU" when shutdown. Before repairing the VFD, should make sure the reason for "OU" alarm is what. Here is because during the VFD deceleration, the speed of the motor rotor winding cutting the rotation magnetic field becomes fast, the rotor electromotive force and current increases, so that the motor is in power generation state. The feedback energy flows to DC part through the diode, which connects in parallel with high-power switch tube in inverting part, and finally causes by DC bus voltage increase. So, should focus on checking the brake circuit. After measuring the discharge resistance, find there's no problem. In the measurement of the brake tube find it breakdown. Replace it and power on, even fast parking have no problem.

Product reviews
Do you provide replacement parts?
5
Rklein
Avatar
7/20/2021 8:53 PM
Is it possible to order replacement part of aproduct purchased from you 2 years ago?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, sure. we provide the replacement parts.
VFD recommended by ATO
5
Reeve
Avatar
9/25/2021 7:34 PM
I am attaching you the details requested by you.
Ok, what is your 1-phase motor rated voltage and current?
230V, 1-Ph, 50Hz, 5 A. Motor Wattage: 1100 W
And what is your 1-phase supply voltage?
230 V, 1 ph supply available
Do let me know if you require any more details.
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, recommended VFD model: GK3000-1S0015, 2hp capacity.
See its specs/price, and you can order online by credit card at: https://www.ato.com/2hp-vfd-single-phase-input-output
3 questions about this VFD
5
Glack
Avatar
3/9/2023 11:13 PM
I am trying to get it to communicate vis Modbus RTU. I can read from the VFD but I can't write to it. These are the parameters I have set
P0.01 4
P0.02 0
P0.03 2
P0.06 70
P0.17 5
P0.18 5
P0.19 70
P3.09 163
P3.10 100
P4.00 11
P8.01 100
Do I have to have a jumper in place on the terminals for the VFD to run? Also, the LOCAL light is flashing on the front of the VFD, why? Do you have any ideas why I can't write to it?
Was this review helpful? Yes No (0/0)
ATO Responded
1. We confirm that the parameter settings of the VFD are correct. You don't need to set a jumper on the terminal to make the VFD run, but you have to send the run command to the VFD by writing the command. Also, you need to write the running frequency into the address 2001H, then you can run the VFD directly through 485 communication.
2. The LOCAL light on the front of the VFD is blinking, which means that the VFD is controlled to start and stop through 485 communication.
3. May I ask what type of controller you use to send the command 485 communication command? PC or PLC? You can refer to VFD's introduction to the RTU mode command (P167) in the attached manual.
We would like to alter the program of VFD
5
vikia
Avatar
7/17/2023 9:37 PM
We have a GK3000-4T0037G VFD.
We would like to alter the program so we can run at different speeds, but we are not sure how to do this.
Could you please follow up with some steps?
We looked through the manual but are still having trouble.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Please provide us with the order number to further confirm what product you purchased. We hope to provide you with better service.
2. Please refer to the quick setup manual and video to set up the inverter.
Manual: https://www.ato.com/Content/doc/VFD-quick-setup-manual-and-application.pdf
Video: https://www.youtube.com/watch?v=uZKsPgcB2a8&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=9
questions
5
Isaac
Avatar
11/23/2023 11:10 PM
We just received 6 new 5hp VFDs and installed them this weekend, we came in yesterday one AHU had a E-12 Failure on the drive, and Leg 1 is only putting out less than 50 Volts.
Was this review helpful? Yes No (0/0)
ATO Responded
Are the 6 VFDs you purchased connected to the Air Handling Unit?  Our VFD can only be connected to the motor, and it is Not recommended to connect to the AHU.
About the switch
4
Benlyon
Avatar
12/9/2024 12:14 AM
I have a 3.7kw vfd that I am using to control a three phase 4hp motor for a panel saw. I do not have 3 ph service thus the use of a VFD. The saw has a start stop switch that is not a push lock style and I would like to use the original switch as much as possible. Based on the quick start manual is seems I would need to use a push lock switch to do a remote start with three wire control. Is there another way to use a push button on/off (no locking switches) to control the saw? I am currently employing the P3 series commands with x1 programmed to start with a after market locking switch. Is there another way?
Was this review helpful? Yes No (0/0)
ATO Responded
You can try to set the parameters: P0.03=1,
P3.00=1 X1 start (normally open)
P3.01=3 X2 stop (normally open)
P3.14=3 (three-wire system)
P3.41=00010 (change the X2 terminal normally closed to normally open)
Please refer to the manual P3 parameter group: https://www.ato.com/Content/doc/gk3000-variable-frequency-drive-user-manual.pdf
High frequency operation
5
Kumire
Avatar
7/10/2025 8:59 PM
I want to drive a 1333hz motor. Does the driver support 16kHz PWM switching frequency operation under high current conditions?
Was this review helpful? Yes No (0/0)
ATO Responded
Our inverters usually cannot drive motors above 1000Hz and the operation is unstable. The frequency extension function is not supported. It does not support 16kHz PWM switching frequency under high current conditions, so it is not suitable for your application scenario.
Reverse connection not working
5
Keske
Avatar
7/2/2026 12:24 AM
I purchased a 5hp (3.7 kW) frequency converter, three-phase 230V input voltage (three-phase) ±15%: 240V SKU: GK3000-4T0037G. I have already connected it, but the reverse connection is not working. Can you help me?
Was this review helpful? Yes No (0/0)
ATO Responded
Are you saying the motor cannot reverse? You only need to swap any two of the three phases U, V, and W to reverse the motor, or you can reverse the motor using the REV button and setting parameter P7.00=5.
Only registered users can write reviews
Customers who bought this item also bought

2 hp (1.5 kW) VFD, 3 Phase 240V, 415V, 480V

GK3000-4T0015G
$218.41
Cheap price 2 hp (1.5 kW) VFD, three phase 240V, 415V, 480V for choice, brand new sensorless vector variable frequency drive, RS485 enabled, strong overload capacity, manufacturer direct sale.

3 hp (2.2 kW) VFD, Three Phase 220V, 380V, 480V

GK3000-4T0022G
$280.48
Low cost 3 hp (2.2 kW) VFD, three phase 220V, 380V, 480V variable frequency drive, IP20 enclosure, RS485 enabled, V/F & vector control, brand new direct sale by manufacturer.

7.5 hp (5.5 kW) VFD, 3 Phase 208V, 380V, 480V

GK3000-4T0055G
$415.08
7.5 hp (5.5 kW) VFD with wholesale price, 3 phase 208V/380V/480V 50Hz/60Hz for option, heavy duty variable frequency drive, 13 amps at 380V ~480V, strong overload capacity, manufacturer direct sale.

10 hp (7.5 kW) VFD, Three Phase 220V, 440V, 480V

GK3000-4T0075G
$463.25
Affordable 10 hp (7.5 kW) VFD, three phase 220V/440V/480V input for option, three phase output variable frequency drive, 17 amps, V/F & vector control, manufacturer direct sale.

5 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0037
$294.31
5hp variable frequency drive, single phase to three phase VFD, 17 amps, RS485 enabled, shipping weight 4kg, manufacturer direct sale.