7.5 hp variable frequency drive, 5.5 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.
Specification:
| Basics | Model | GK3000-1S0055 |
| Capacity | 7.5 hp (5.5 kW) | |
| Shipping weight | 9 kg | |
| Dimension | 330*200*200 mm | |
| I/O Feature | Rated current | 32 A |
| Input voltage | single phase AC 220V±15% | |
| Input frequency | 47~63Hz | |
| Output voltage | 0~rated input voltage | |
| Output frequency | 0~1000Hz | |
| Over load capacity | 150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s | |
| Control Features | Control mode | V/F, Sensorless vector control (SVC), Speed sensor vector control (FVC) |
| Operation command mode | Keypad control, Terminal control, Serial communication control | |
| Frequency setting mode | Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes. | |
| Start frequency | 0.40Hz~20.00Hz | |
| Speed adjustment range | 1:50 | |
| Carrier frequency | 1.0-16.0kHz, automatically adjusted according to temperature and load characteristics | |
| Frequency accuracy | Digital setting: 0.01Hz Analog setting: Maximum frequency * 0.05% | |
| Torque boost | Automatically torque boost; manually torque boost: 0.1%~30.0% | |
| V/f curve | Three types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square) | |
| Acceleration/deceleration mode | Straight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s | |
| Jog operation | Jog operation frequency: 0.0Hz~maximum frequency Jog acceleration/deceleration time: 0.1s~3600.0s | |
| Simple PLC & multi-step speed operation | It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal. | |
| Built-in PID | Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) | |
| Automatic voltage regulation | Keep output voltage constant automatically when input voltage fluctuating | |
| Control Function | Common DC bus | Common DC bus for several VFDs, energy balanced automatically |
| Torque control | Torque control without PG | |
| Torque limit | "Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process | |
| Wobble frequency control | Multiple triangular-wave frequency control, special for textile | |
| Timing/length/counting control | Timing/length/counting control function | |
| Over-voltage & over-current stall control | Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping | |
| Fault protection function | Up to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function | |
| Input/output terminals | Input terminals | Programmable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI: AI1: 0~10V or 0/4~20mA A12: 0~10V or 0/4~20mA |
| Output terminals | 1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output) 2 relay output 2 analog output: 0/4~20mA or 0~10V | |
| Communication terminals | Offer RS485 communication interface, support MODBUS-RTU communication protocol | |
| Human machine interface | LED display | Display frequency setting, output frequency, output voltage, output current, etc. |
| Multifunction key | QUICK/JOG key, can be used as multifunction key | |
| Environment | Ambient temperature | -10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃). |
| Humidity | 90%RH or less (non-condensing) | |
| Altitude | ≤1000M: Output rated power, >1000M: Output derated | |
| Storage temperature | -20℃~60℃ |
Note:
- The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
- ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
- Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
- If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.
Tips: Variable frequency drive functions in air conditioning
- In air conditioning, VFD can make the compressor motor speed continuously adjustable, and the speed is based on indoor air conditioning load proportional change. When the room needs rapid cooling (or rapid warming), air conditioning load will increase, the compressor speed up, and the cooling (or heating) capacity will proportion increases. And then after reaches the set temperature, the system will operate in low-speed to maintain room temperature.
- VFD air conditioner uses electronic expansion valve to control the flow, and its outdoor micro processor controls the valve opening degree based on the expansion valve inlet and outlet, the compressor in the air pipe at the temperature sensor to collect information, which can change the flow of refrigerant at any time. The speed of the compressor corresponds to the opening degree of the expansion valve, so that the capacity of the evaporator can be maximized. At the same time, because of using electronic expansion valve as a throttle element, the device will not stop when defrost. It uses compressor exhaust heat to the indoor, and then sends the remaining heat to the outside to melt the frost on heat exchanger fin.
- VFD air conditioner will gradually replace the traditional fixed speed air conditioner, and becoming the main stream of air conditioning control technology. The frequency conversion technology has been changed from AC type to DC type, and the control technology has been developed from PWM (Pulse Width Modulation) to PAM (Pulse Amplitude Modulation). The speed of the compressor with PWM control is limited by the upper limit speed, generally not more than 7,000/min, and the compression speed of PAM control mode can be increased for about 1.5 times, which greatly improves the refrigeration capacity at refrigeration and low temperature.
Product reviews
7.5hp (5.5kW) VFD connection problem
Mahem
3/25/2021 7:22 PM
When connecting a 1-phase VFD to a 1-phase motor, can I remove the start/run capacitor?
Was this review helpful? (0/0)
7.5 hp single phase VFD drive
Wilson
4/28/2021 12:04 AM
I want to purchase your 7.5 hp 1 phase VFD, but my motor has 2 starting capacitor and 1 running capacitor? Does that work?
Was this review helpful? (0/0)
How to choose a VFD?
Sneaky
5/9/2021 9:49 PM
I have a 3 hp 115 volt 30 amp motor that I need a VFD for. What are my options for this application?
Was this review helpful? (0/0)
The use effect of VFD
Randrsn
8/31/2021 12:49 AM
I've been in the electrical business for a long time and I'm very pleased to see your single phase output VFD. How can the starting torque be compared when using the drive VS the same motor starting with its original capacitors? Taking this to a bad case like starting a piston compressor, would it work?
Was this review helpful? (0/0)
We are looking for a VFD. Can you give us some advice?
Terepocki
1/24/2022 6:04 PM
We are looking for single phase input and output VSD for single Phase fan 230VAC, 0.4kW. Could you please give me advice?
Was this review helpful? (0/0)
VFD problem.
Danie
5/25/2022 3:03 AM
I have installed a GK3000 single phase VFD, a 3 phase motor is connected. The VFD boots up and there are no alarms. When I run the VFD the display shows the output frequency and output voltage but the motor does not turn and there is no voltage outputting to the motor.
Was this review helpful? (0/0)
What VFD setting should adjust?
paddy
3/1/2023 8:47 PM
I am currently trying to program my gk3000 VFD to operate my 7.5 hp motors.
I have 240V single phase from two inverters. I have 195V per wire on the output.
I am wanting 115V per wire on the out put. What setting should I adjust to achieve my goal?
I have 240V single phase from two inverters. I have 195V per wire on the output.
I am wanting 115V per wire on the out put. What setting should I adjust to achieve my goal?
Was this review helpful? (0/0)
I want to add VFD’s to our two 10hp irrigation pump motors.
Mervyn
3/3/2023 12:15 AM
I want to add VFD’s to our two 10hp irrigation pump motors. So we can set the ramp rate and reduce water hammering.
I was told that you can’t get VFD’s for single phase motors over 5 hp but then came across yours.
I have attached the name plate from one of the motors (they’re both the same).
I was told that you can’t get VFD’s for single phase motors over 5 hp but then came across yours.
I have attached the name plate from one of the motors (they’re both the same).
Was this review helpful? (0/0)
Overheated the compressor
Keran
4/4/2023 12:18 AM
We have successfully tested this VFD with our air-conditioning compressor (model: Copeland ZR48K3E-PFJ-522 / Locked motor current: 114 A / max. operating current: 23.5 A, starting capacitor: 60 uF). However, the only configuration which really works is a two-terminal connection with the starting capacitor present. Unfortunately, all other 3-wire configurations, which directly supply the secondary winding as presented in the manual, resulted in very high currents, which immediately overheated the compressor. The running current, as shown on the VFD screen, is about 9.2 A in normal operation, but was exceeding 25 A when connected in a 3-wire configuration. Could you please explain this problem? When trying to supply the VFD directly from the available 330 V DC bus, the inrush current is extremely high, immediately blowing a slow-blow 30 A fuse. Could you please provide the exact total capacity of the internal capacitors of the VFD? We need to either install a bigger fuse or, better, provide a slow-start for charging the internal capacitors of the VFD without blowing the fuse.
Was this review helpful? (0/0)
What is the best way to wire the auxiliary contacts to start this VFD?
luna
5/10/2023 2:01 AM
What is the best way to wire the auxiliary contacts to start this drive with a time clock and what would I need to change in the programing?
Thank you.
Thank you.
Was this review helpful? (0/0)
I need your help to solve VFD problem
duran
6/16/2023 12:20 AM
I am having problems programing a 220v 5.5kw single phase drive is there any way that I can contact you for help.
Was this review helpful? (0/0)
Is there any way to go through the VFD parameters over the phone?
doro
7/17/2023 10:03 PM
OK, this drive is running a single-phase 240 V motor with the capacity of no pressure transducer.
I have set all parameters but when I push the start button, the motor does not turn and just hums.
I am also trying to use a 2-wire control to start and stop the motor with a time block. Is there any way to go through the parameters over the phone?
I have set all parameters but when I push the start button, the motor does not turn and just hums.
I am also trying to use a 2-wire control to start and stop the motor with a time block. Is there any way to go through the parameters over the phone?
Was this review helpful? (0/0)
How do I set the starting frequency?
vickey
9/4/2023 2:50 AM
My frequency range is from 40 to 60 and it starts at 40Hz.
How do I set the starting frequency?
How do I set the starting frequency?
Was this review helpful? (0/0)
Can I use a phased sine wave filter (partially) in a single phase output?
lily
9/4/2023 3:27 AM
We purchased three 7.5 hp (5.5 kW) VFD's from your company and we would like to filter their outputs as we have noticed that they stress the compressor start capacitors, one of which has failed. Is it possible to use a phase sine wave filter (partially) in the single phase output? Or do you know of any manufacturer that offers this solution?
Was this review helpful? (0/0)
Can I adjust the frequency it operates at while running?
Ivy01
10/9/2023 12:48 AM
Sorry for the confusion. My frequency range is 40 to 60 Hz. When I power up the VFD, the display flashes 40Hz. Can I adjust the frequency it operates at while running?
Was this review helpful? (0/0)
Factory reset procedure
Glorie
10/15/2024 12:32 AM
What is the factory reset procedure for a GK3000 VFD?
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
3 hp (2.2 kW) VFD, Single Phase Input & Output
GK3000-1S0022
$379.23
Cheap 3 hp VFD, 1 phase for single phase AC induction motor, good variable speed performance, 220V - 240V 17 amps, manufacturer direct sale.
5 hp (4 kW) VFD, Single Phase Input & Output
GK3000-1S0037
$649.54
Low cost 5 hp VFD, 1 phase for single phase AC motor speed controls, 220V - 240V 25 amps, manufacturer direct sale.
Pressure Sensor for Air/Water/Oil, 4-20mA/0-5V/RS485 Output
ATO-PRES-P300
$119.68
Silicon piezoresistive pressure sensor covers -0.1 to 100 MPa with 4–20mA, 0–20mA, multiple voltage or RS485 output options. Stainless steel construction supports air, water and oil pressure measurement at medium temperatures from -40°C to 60°C.
AC/DC Voltage Sensor 75mV to 500V, RMS 0-5V/0-10V/4-20mA/0-20mA Output
ATO-VOS-ACDC500
$161.27
Voltage sensor has voltage measuring range from AC/DC 75mV/50V/100V/250V/300V to 500V, supply voltage DC 12V/24V, output DC voltage/current or True RMS voltage/current signal 0-5V/0-10V/0-20mA/4-20mA and protection class IP20. AC/DC voltage sensor has two installation methods, DIN rail installation and M3 screw fixation.
2 hp (1.5 kW) VFD, Single Phase Input & Output
GK3000-1S0015
$243.08
Discounted 2 hp VFD, 1 phase for single phase AC motor, 220V - 240V 9.6 amps, brand new direct sale by manufacturer.