2 hp (1.5 kW) VFD, 3 Phase 240V, 415V, 480V

$218.41
Cheap price 2 hp (1.5 kW) VFD, three phase 240V, 415V, 480V for choice, brand new sensorless vector variable frequency drive, RS485 enabled, strong overload capacity, manufacturer direct sale.
SKU: GK3000-4T0015G
Availability: In stock
Free Shipping
Delivery date: 2-3 days

2 hp variable frequency drive, three phase 240V, 415V, 480V for choice.

Specification:

BasicsModelGK3000-4T0015G/ GK3000-2T0015G
Capacity2 hp (1.5 kW)
Shipping weight2 kg
Dimension190*104*150 mm for GK3000-4T0015G/ 236*130*176 for GK3000-2T0015G
I/O FeatureRated current3.8A at 380V ~ 480V, 5.1A at 220V ~ 240V
Input voltage3 phase 240V /415V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

1500W Three Phase VFD Details

Tips: Variable frequency drive harmonic wave problems and solutions
The devices that have switch effect in VFD main circuit will produce harmonics wave in the process of on-off circuit. The lower harmonics usually have large effect on the motor load, causing the torque ripple. And the higher harmonics increase the leakage current of the VFD output cable, causing low output. Harmonic wave interference can also lead to misoperation of the relay protection device, so that the electrical instrument measurement is not accurate, or even cannot work properly.
The treatment of harmonic wave problems is to cut off the interference route transmission and suppress high harmonic wave of interference source.
The methods of cutting off the interference route transmission:

  1. Cut off the approach of common ground wire propagation interference. The ground connection of the power line and the ground connection of the control line should be separated, that is connecting the grounding terminal of the drive device to the earth wire, and the grounding terminal of the control device to its metal shell.
  2. Set the signal line away from the interference source power wire. Wiring separation is effective in eliminating this interference, that is, to separate the high-voltage cables, power cables, control cables, instrument cables and computer cables wiring.

The methods to suppress higher harmonic wave on the interference source:

  1. Increase the internal impedance of the VFD power supply. Usually the internal impedance of the power supply device has the function of buffering the reactive power of the DC filter capacitor. The larger the internal impedance, the fewer the harmonic wave content. The internal impedance is the short circuit impedance of the transformer. Therefore, when choosing variable frequency drive power supply, the best choice is large short circuit impedance ones.
  2. Install the filter. In the front of VFD, install the LC-type passive filter can filter out 5 and 7 times of high harmonic wave.
  3. Install the reactor. Install the line reactor in the front of VFD to suppress the overvoltage on the power supply.
  4. Set the active filter. Active filtering can automatically generate a current that has the same amplitude and the opposite phase of the harmonic current, so that can effectively absorb the harmonic wave current.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
Questions about 2hp VFD
5
Stafford
Avatar
4/26/2021 12:51 AM
I have one more question, actually. Does this 1ph To 3ph, 2hp VFD require a line neutral ground connection? The only outlets I have available are either 120V line-neutral-ground or 240V split-phase hot-hot-ground connection?
Was this review helpful? Yes No (0/0)
ATO Responded
The dive input can be 240V split phase hot-hot-ground connection. Just connect the 2 hot lines to VFD L,N input terminals, it works with no problem.
Our confusion about VFD settings
5
Jray
Avatar
9/15/2021 7:27 PM
We are setting up the VDF, but are a lot confused.
We need it to start at 5Hz. It should be P020, but when we set that to 5, the VFD starts at 0 and runs to 5Hz?
We set it to 60 and it starts from 0 and accelerates till 60.
Was this review helpful? Yes No (0/0)
ATO Responded
Please set P2.01=5, and test again.
My doubts about VFD installation
5
Bletscher
Avatar
11/18/2021 12:11 AM
Can I just install your 7 inch HMI to your GK3000 variable frequency drive without a plc? And everything works ok?
Was this review helpful? Yes No (0/0)
ATO Responded
If there is no PLC, you can install HMI to vfd, but you need to program the configuration parameters yourself. So it is easier / better to use PLC.
Can a VFD be programmed?
5
phandler
Avatar
12/12/2022 7:33 PM
Can this VFD be programmed to reverse for a few seconds and then return to forward automatically?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can be, but your motor must be a three-phase motor, and the speed of reverse rotation and the speed of forward rotation (frequency) must be the same.
That is to say, the three-phase motor and VFD can be programmed to reverse for three seconds each time they are started, and then run forward, but the reverse frequency is the same as the forward frequency.
How do I change them?
5
Glenny
Avatar
8/7/2023 1:18 AM
I bought 2  variable frequency drives. How do I set parameters to change them?
Was this review helpful? Yes No (0/0)
ATO Responded
Please refer to Chapter 5 of the manual to set parameters: https://www.ato.com/Content/doc/gk3000-variable-frequency-drive-user-manual.pdf
Please refer to the video: https://www.youtube.com/watch?v=zxTVneMG5Jo&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=27
If you can Not set it, please ask your electrician to set the parameters we told you earlier.
Good power conversion
5
Nichaolas
Avatar
9/5/2023 1:44 AM
It handles the power conversion effortlessly, ensuring a consistent and reliable three-phase output. My machinery now operates with exceptional precision and efficiency, leading to increased productivity.
Was this review helpful? Yes No (0/0)
When power goes out
4
Adela
Avatar
7/22/2024 3:24 AM
When power goes out, how do we make them start back up again? Because right now we have to run to them and make sure they are running.`
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our VFD does not have the function of automatic restart after power failure. If you want to achieve this function, you can only do it through external terminal wiring.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

2 hp variable frequency drive, three phase 240V, 415V, 480V for choice.

Specification:

BasicsModelGK3000-4T0015G/ GK3000-2T0015G
Capacity2 hp (1.5 kW)
Shipping weight2 kg
Dimension190*104*150 mm for GK3000-4T0015G/ 236*130*176 for GK3000-2T0015G
I/O FeatureRated current3.8A at 380V ~ 480V, 5.1A at 220V ~ 240V
Input voltage3 phase 240V /415V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

1500W Three Phase VFD Details

Tips: Variable frequency drive harmonic wave problems and solutions
The devices that have switch effect in VFD main circuit will produce harmonics wave in the process of on-off circuit. The lower harmonics usually have large effect on the motor load, causing the torque ripple. And the higher harmonics increase the leakage current of the VFD output cable, causing low output. Harmonic wave interference can also lead to misoperation of the relay protection device, so that the electrical instrument measurement is not accurate, or even cannot work properly.
The treatment of harmonic wave problems is to cut off the interference route transmission and suppress high harmonic wave of interference source.
The methods of cutting off the interference route transmission:

  1. Cut off the approach of common ground wire propagation interference. The ground connection of the power line and the ground connection of the control line should be separated, that is connecting the grounding terminal of the drive device to the earth wire, and the grounding terminal of the control device to its metal shell.
  2. Set the signal line away from the interference source power wire. Wiring separation is effective in eliminating this interference, that is, to separate the high-voltage cables, power cables, control cables, instrument cables and computer cables wiring.

The methods to suppress higher harmonic wave on the interference source:

  1. Increase the internal impedance of the VFD power supply. Usually the internal impedance of the power supply device has the function of buffering the reactive power of the DC filter capacitor. The larger the internal impedance, the fewer the harmonic wave content. The internal impedance is the short circuit impedance of the transformer. Therefore, when choosing variable frequency drive power supply, the best choice is large short circuit impedance ones.
  2. Install the filter. In the front of VFD, install the LC-type passive filter can filter out 5 and 7 times of high harmonic wave.
  3. Install the reactor. Install the line reactor in the front of VFD to suppress the overvoltage on the power supply.
  4. Set the active filter. Active filtering can automatically generate a current that has the same amplitude and the opposite phase of the harmonic current, so that can effectively absorb the harmonic wave current.
Product reviews
Questions about 2hp VFD
5
Stafford
Avatar
4/26/2021 12:51 AM
I have one more question, actually. Does this 1ph To 3ph, 2hp VFD require a line neutral ground connection? The only outlets I have available are either 120V line-neutral-ground or 240V split-phase hot-hot-ground connection?
Was this review helpful? Yes No (0/0)
ATO Responded
The dive input can be 240V split phase hot-hot-ground connection. Just connect the 2 hot lines to VFD L,N input terminals, it works with no problem.
Our confusion about VFD settings
5
Jray
Avatar
9/15/2021 7:27 PM
We are setting up the VDF, but are a lot confused.
We need it to start at 5Hz. It should be P020, but when we set that to 5, the VFD starts at 0 and runs to 5Hz?
We set it to 60 and it starts from 0 and accelerates till 60.
Was this review helpful? Yes No (0/0)
ATO Responded
Please set P2.01=5, and test again.
My doubts about VFD installation
5
Bletscher
Avatar
11/18/2021 12:11 AM
Can I just install your 7 inch HMI to your GK3000 variable frequency drive without a plc? And everything works ok?
Was this review helpful? Yes No (0/0)
ATO Responded
If there is no PLC, you can install HMI to vfd, but you need to program the configuration parameters yourself. So it is easier / better to use PLC.
Can a VFD be programmed?
5
phandler
Avatar
12/12/2022 7:33 PM
Can this VFD be programmed to reverse for a few seconds and then return to forward automatically?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can be, but your motor must be a three-phase motor, and the speed of reverse rotation and the speed of forward rotation (frequency) must be the same.
That is to say, the three-phase motor and VFD can be programmed to reverse for three seconds each time they are started, and then run forward, but the reverse frequency is the same as the forward frequency.
How do I change them?
5
Glenny
Avatar
8/7/2023 1:18 AM
I bought 2  variable frequency drives. How do I set parameters to change them?
Was this review helpful? Yes No (0/0)
ATO Responded
Please refer to Chapter 5 of the manual to set parameters: https://www.ato.com/Content/doc/gk3000-variable-frequency-drive-user-manual.pdf
Please refer to the video: https://www.youtube.com/watch?v=zxTVneMG5Jo&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=27
If you can Not set it, please ask your electrician to set the parameters we told you earlier.
Good power conversion
5
Nichaolas
Avatar
9/5/2023 1:44 AM
It handles the power conversion effortlessly, ensuring a consistent and reliable three-phase output. My machinery now operates with exceptional precision and efficiency, leading to increased productivity.
Was this review helpful? Yes No (0/0)
When power goes out
4
Adela
Avatar
7/22/2024 3:24 AM
When power goes out, how do we make them start back up again? Because right now we have to run to them and make sure they are running.`
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our VFD does not have the function of automatic restart after power failure. If you want to achieve this function, you can only do it through external terminal wiring.
Only registered users can write reviews
Customers who bought this item also bought

5 hp (3.7 kW) VFD, 3 Phase 230V, 400V, 480V

GK3000-4T0037G
$293.51
Favorable price 5 hp (3.7 / 4 kW) VFD, three phase 230V, 400V, 480V, high performance vector variable frequency drive, IP20 enclosure, RS485 enabled, brand new direct sale by manufacturer.

3 hp (2.2 kW) VFD, Three Phase 220V, 380V, 480V

GK3000-4T0022G
$280.48
Low cost 3 hp (2.2 kW) VFD, three phase 220V, 380V, 480V variable frequency drive, IP20 enclosure, RS485 enabled, V/F & vector control, brand new direct sale by manufacturer.

7.5 hp (5.5 kW) VFD, 3 Phase 208V, 380V, 480V

GK3000-4T0055G
$415.08
7.5 hp (5.5 kW) VFD with wholesale price, 3 phase 208V/380V/480V 50Hz/60Hz for option, heavy duty variable frequency drive, 13 amps at 380V ~480V, strong overload capacity, manufacturer direct sale.

2 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0015
$183.16
2 hp VFD, convert single phase to three phase for AC motor speed controls, 7 amps, IP20, RS485 enabled, manufacturer direct sale.

1 hp (0.75 kW) VFD, Single Phase Input & Output

GK3000-1S0007
$195.82
Affordable 1 hp VFD, 1 phase for single phase AC induction motor, 220V - 240V 7 amps, manufacturer direct sale.