100 hp (75 kW) Soft starter, 150 A, 3ph 240v/400v/480v

$619.62
High quality 100 hp soft starter, 75 kW three phase 240v, 400v, 480v for selection, control motor in soft start & soft stop, direct sale by manufacturer.
SKU: GS-075
Free Shipping
Delivery date: 2-3 days

100 hp AC motor soft starter, 75 kW three phase 240v, 400v, 480v, 690v for selection, manufacturer direct sale.

ModelGS2-075 (220v, 240v), GS3-075 (380v, 400v, 415v), GS4-075 (460v, 480v), GS6-075 (575v, 690v).
Capacity100 hp (75 kw)
Current150 amps at 380v/480v, 320 amps at 220v, 90 amps at 690v
Weight5 kgs
Dimension270*146*160 mm
InputVoltageThree-phase 230v, 420v, 480v, 690v AC
Frequency50Hz/ 60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.
485 CommunicationDB9 interface, male plug, ① is RS485+, ⑥ is RS485-
Control Mode
  1. Operation panel control.
  2. Operation panel + external control.
  3. External control.
  4. External control + COM control.
  5. Operation panel + external + COM control.
  6. Operation panel + COM control.
  7. COM control.
  8. No start or stop operation.
Start Mode
  1. Current-limiting to start.
  2. Voltage ramp to start.
  3. Torque control + current-limiting to start.
  4. Torque control + voltage ramp to start.
  5. Current ramp to start.
  6. Voltage current-limiting double closed-loop start.
Stop Mode
  1. Soft stop.
  2. Free stop.
Protective Function
  1. Open loop protection for external instantaneous stop terminals.
  2. Over-heat protection for soft starter.
  3. Protection for too long starting time.
  4. Input open phase protection.
  5. Output open phase protection.
  6. Unbalanced three-phase protection.
  7. Starting over current protection.
  8. Running overload protection.
  9. Under voltage protection for power voltage.
  10. Overvoltage protection for power voltage.
  11. Protection for fault parameter setting of the soft starter.
  12. Load short circuit protection.
  13. Auto restart or incorrect wiring protection.
  14. Incorrect wiring protection of external control stop terminals.
AmbientPlace to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
AltitudeBelow 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
Temperature-30 +55 oC
Humidity90%RH without dew condensation.
Vibration<0.5G
StructureEnclosureIP 20
CoolingNatural wind cooling.

Details

75KW Soft Starters Details

Tips: The choice of soft starter capacity
In principle, the soft starter capacity should be greater than the capacity of the motor it drove. The rated capacity of the soft starter usually has two nominal values. One nominal value is according to the corresponding motor power, and the other is according to the allowable maximum operating current of soft starter. Should pay attention to the following two points:

  1. According to the motor rated power, then the product of different voltage levels has different rated current. For example, a 100hp (75kW) soft starter, if the voltage level is AC380V, then the rated current is 150A, if the voltage level is AC660V, the rated current is 100A.
  2. According to the allowable maximum operating current of soft starter, the product of different voltage levels has different rated capacity. For example, a 160A soft starter, if voltage level is AC380V, the rated capacity is 100hp (75kW), if voltage level is AC660V, the rated capacity is 180hp (132kW).

Also should synthetically consider other factors for selection, such as the soft starter carrying capacity, working system, environmental conditions, cooling conditions and others.

Soft Starter Works with a Bypass Contactor

Soft starter works with a bypass contactor saving energy by eliminating thyristor losses during the run. The bypass contactor shunts the current flowing through the soft starter switch circuit to reduce heat accumulation in the soft starter power electronics during motor operation. This provides maximum efficiency and prolongs the life of soft-start switching components because they only work during the start and stop cycles of the motor.

How to Change the Soft Starter Rated Current

Delayed Soft Start of A Motor

In this video, we introduce how to use a soft starter together with a bypass contactor to achieve a delayed soft start of a motor.

Product reviews
100HP Soft Starter
5
Johan
Avatar
10/26/2018 12:34 AM
Just took 5 days to receive the ATO 100 hp soft starter, I applied it to my ball mill, the startup process was smooth and fast, thanks!
Was this review helpful? Yes No (1/0)
If the soft starter I have can be fed with DC and output 240v AC?
5
mona
Avatar
6/12/2023 9:34 PM
I was wondering if the soft starter I have can be fed with DC and output 240v AC.
It's the 60hp soft starter you sell.
Was this review helpful? Yes No (0/0)
ATO Responded
What is your order number? Please provide us with the nameplate label of the soft starter to confirm the model number.
Thank you for your understanding.
The soft starter can not be fed with DC and output 240v AC.
If you want to input DC voltage and output AC voltage, you can use off-grid inverter, please see spec on: https://www.inverter.com/off-grid-inverter
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

100 hp AC motor soft starter, 75 kW three phase 240v, 400v, 480v, 690v for selection, manufacturer direct sale.

ModelGS2-075 (220v, 240v), GS3-075 (380v, 400v, 415v), GS4-075 (460v, 480v), GS6-075 (575v, 690v).
Capacity100 hp (75 kw)
Current150 amps at 380v/480v, 320 amps at 220v, 90 amps at 690v
Weight5 kgs
Dimension270*146*160 mm
InputVoltageThree-phase 230v, 420v, 480v, 690v AC
Frequency50Hz/ 60Hz
Adaptive MotorSquirrel-cage three-phase asynchronous motor
Starting TimesIt is recommended not to exceed 20 times per hour.
485 CommunicationDB9 interface, male plug, ① is RS485+, ⑥ is RS485-
Control Mode
  1. Operation panel control.
  2. Operation panel + external control.
  3. External control.
  4. External control + COM control.
  5. Operation panel + external + COM control.
  6. Operation panel + COM control.
  7. COM control.
  8. No start or stop operation.
Start Mode
  1. Current-limiting to start.
  2. Voltage ramp to start.
  3. Torque control + current-limiting to start.
  4. Torque control + voltage ramp to start.
  5. Current ramp to start.
  6. Voltage current-limiting double closed-loop start.
Stop Mode
  1. Soft stop.
  2. Free stop.
Protective Function
  1. Open loop protection for external instantaneous stop terminals.
  2. Over-heat protection for soft starter.
  3. Protection for too long starting time.
  4. Input open phase protection.
  5. Output open phase protection.
  6. Unbalanced three-phase protection.
  7. Starting over current protection.
  8. Running overload protection.
  9. Under voltage protection for power voltage.
  10. Overvoltage protection for power voltage.
  11. Protection for fault parameter setting of the soft starter.
  12. Load short circuit protection.
  13. Auto restart or incorrect wiring protection.
  14. Incorrect wiring protection of external control stop terminals.
AmbientPlace to be usedIndoor location with good ventilation free from corrosive gas and conductive dust.
AltitudeBelow 1000M. It has to increase the soft starter rate power when the altitude is more than 1000M.
Temperature-30 +55 oC
Humidity90%RH without dew condensation.
Vibration<0.5G
StructureEnclosureIP 20
CoolingNatural wind cooling.

Details

75KW Soft Starters Details

Tips: The choice of soft starter capacity
In principle, the soft starter capacity should be greater than the capacity of the motor it drove. The rated capacity of the soft starter usually has two nominal values. One nominal value is according to the corresponding motor power, and the other is according to the allowable maximum operating current of soft starter. Should pay attention to the following two points:

  1. According to the motor rated power, then the product of different voltage levels has different rated current. For example, a 100hp (75kW) soft starter, if the voltage level is AC380V, then the rated current is 150A, if the voltage level is AC660V, the rated current is 100A.
  2. According to the allowable maximum operating current of soft starter, the product of different voltage levels has different rated capacity. For example, a 160A soft starter, if voltage level is AC380V, the rated capacity is 100hp (75kW), if voltage level is AC660V, the rated capacity is 180hp (132kW).

Also should synthetically consider other factors for selection, such as the soft starter carrying capacity, working system, environmental conditions, cooling conditions and others.

Product reviews
100HP Soft Starter
5
Johan
Avatar
10/26/2018 12:34 AM
Just took 5 days to receive the ATO 100 hp soft starter, I applied it to my ball mill, the startup process was smooth and fast, thanks!
Was this review helpful? Yes No (1/0)
If the soft starter I have can be fed with DC and output 240v AC?
5
mona
Avatar
6/12/2023 9:34 PM
I was wondering if the soft starter I have can be fed with DC and output 240v AC.
It's the 60hp soft starter you sell.
Was this review helpful? Yes No (0/0)
ATO Responded
What is your order number? Please provide us with the nameplate label of the soft starter to confirm the model number.
Thank you for your understanding.
The soft starter can not be fed with DC and output 240v AC.
If you want to input DC voltage and output AC voltage, you can use off-grid inverter, please see spec on: https://www.inverter.com/off-grid-inverter
Only registered users can write reviews
Customers who bought this item also bought

30 hp (22 kW) Soft starter, 43 A, 3ph 240v/415v/480v

GS-022
$426.11
Low cost 30 hp soft starter, 22 kW 3 phase 240v, 415v, 480v affordable motor soft starter direct sale from manufacturer from China.

3 Pole Molded Case Circuit Breaker, 100A/ 150A/ 200A/ 250A

ATO-MCCB-2503P
$139.14
3 pole molded case circuit breaker at lower price, easy to install. Mccb breaker is capable of protecting the system against short circuit current up to 50kA. It has 1500 times' electrical life and 8500 times' mechanical life. Molded circuit breaker is used to distribute electric energy and protect circuits and electrical equipment from overload or short circuit.