40 hp (30 kW) VFD, 3 Phase 230V, 420V, 480V

$1,497.31
High quality 40 hp (30 kW) VFD with low cost, three phase 230V, 420V, 480V variable frequency drive with good performance, brand new direct sale by manufacturer.
SKU: GK3000-4T0300G
Free Shipping
Delivery date: 6-12 days

40 hp (30 kW) heavy duty variable frequency drive, three phase 230V, 420V, 480V for choice.

Specification:

BasicsModelGK3000-4T0300G/ GK3000-2T0300G
Capacity40 hp (30 kW)
Shipping weight22 kg
Dimension (L*W*H)530*320*235 mm for GK3000-4T0300G/ 555*310*260 for GK3000-2T0300G
I/O FeatureRated current60A at 380V ~ 480V, 112A at 220V ~ 240V
Input voltage3 phase 230V /420V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40 ℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive advantage in injection molding machine energy saving retrofit
For the plastic products industry, power consumption is the main part of production cost, and injection molding machine is the main energy consumption equipment. At present, most of the injection molding machine is hydraulic transmission type, the power in hydraulic system is offered by the motor driven pump. During the injection molding cycle, the flow and pressure required for injection molding machines different processes are different under, and must be dependent on the flow valve and pressure valve to adjust the flow and pressure required for different processes. Hydraulic system has high load changes, because the quantitative pump can't adjust the output power, so the excess energy can only be consumed in the baffle, oil leakage, or oil temperature rise. This has exacerbated the wear of valves, too high oil temperature and too large noise, and the mechanical life can also be shorted. And in usually design, the motor design capacity for user pump is much higher than the actual needs, resulting in a lot of energy waste. Therefore, the promotion of AC variable frequency speed control device in the application of injection molding machine has great significance for reducing energy waste and saving production cost.
The VFD has incomparable advantages in the energy-saving retrofit of injection molding machine. When injection molding machine in frequency conversion retrofit wiring, retain the original computer control system, oil-line of hydraulic transmission system and motor Y-△ step-down start running circuit unchanged. And use variable frequency energy-saving / frequency operation conversion control mode to avoid affecting the normal production when failure occurred. When replacing the mold, only need to change the injection molding machine computer board working procedures, and don’t need to make any adjustments to the VFD.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
Can one VFD run multiple motors?
5
Baker
Avatar
7/26/2021 9:30 PM
Can 1 controller run multiple motors? Ie, a 2 hp unit run 4, 1/2 hp fan motors?
Was this review helpful? Yes No (0/0)
ATO Responded
It can be, but all motors should be switched on/off together at the same instant via VFD buttons only, and you have to use 3hp VFD to run 4, 1/2 hp fan motors. But We recommend using one drive for one motor.
I need some help to solve VFD
5
greer
Avatar
7/20/2023 3:58 AM
Installed Gk3000-4T0300G.
The system started up and ran well yesterday.
Came in this morning and started up the system and today we are seeing motor speed not constant and varying downward. And then going out with an E-10 fault.
I need some help.
Was this review helpful? Yes No (0/0)
ATO Responded
What parameters did you set?
Please provide the motor nameplate and wiring diagram for further confirmation.
You can refer to the manual settings.
Manual: https://www.ato.com/Content/doc/ato-gk3000-series-vfd-user-manual.pdf
https://www.ato.com/Content/doc/VFD-quick-setup-manual-and-application.pdf
How to solve VFD problem?
5
janaya
Avatar
7/20/2023 6:53 PM
I purchased 4 VFDs last week installed them and am having an issue with one of them. Would really like a call to address this issue.
We are having issues with an installation of a 15 HP VFD.
The output to our motor is causing the motor to pulse and can not get to steady out. Am I missing something?
3-phase input and output 480V system.
After a few minutes, we are seeing E-10.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for contacting us and sorry for keeping you waiting.
1. Gk3000-4T0300G shows fault code E-10 because the motor is overloaded.
Please send us your motor nameplate label to further confirm whether the motor and VFD match.
Also, you can set P0.22=2 or 3, P0.17=20, P0.18=20, P5.01=120%, P5.04= 180%, and test again.
2. If there is still a problem, please send us a picture of the VFD&motor nameplate label for further confirmation.
It is important for us to figure out a solution. Thank you for your understanding.
3. Please send us the start-up running video to us for further confirmation, the video should show the running status of VFD and motor. You can send us the large video file via wetransfer.com.
Also, you can refer to our demonstration video, please see: https://www.youtube.com/watch?v=nBUm4i9wnzY&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=12&t=101s
We are very concerned about the problems our your encounter, and to be not worried, we will do our best to meet your needs.
What is the default output voltage while running at 50Hz?
5
lily
Avatar
9/4/2023 2:51 AM
I have a VFD model GK3000-4TO300G. I am aware the default setting for the Hz is 50Hz and that is what I need but I need a maximum of 400V.
What is the default output voltage while running at 50Hz?
Was this review helpful? Yes No (0/0)
ATO Responded
Whether it is possible for your VFD output to reach 400V depends on the specific voltage when you purchase it.
Please provide us with the order number to further confirm what product you purchased. We hope to provide you with better service.
We need to know the exact model and parameters of the product you purchased in order to give you the correct advice, thank you for your understanding.
You can also send pictures and nameplates of the products to us for further confirmation.
I have the issue resolved with the three wire start stop wiring
5
Bruce
Avatar
10/24/2023 2:12 AM
I have the issue resolved with the three wire start stop wiring. I still am having an issue with the E-19 input phase loss. I found the parameter pa.12 and changed that setting to 10. The system runs without faulting out buti do not show a current draw on c phase which would be one of the 2 single phase inputs into the phase converter that is manufacturing the third phase. Please advise of the draw backs of turning off the input phase loss setting. Does it change the capability of the drive?
Was this review helpful? Yes No (0/0)
ATO Responded
The input is a three-phase voltage. If there is no correlation or phase loss protection, it does Not matter. It will Not change the driving capability of the VFD.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

40 hp (30 kW) heavy duty variable frequency drive, three phase 230V, 420V, 480V for choice.

Specification:

BasicsModelGK3000-4T0300G/ GK3000-2T0300G
Capacity40 hp (30 kW)
Shipping weight22 kg
Dimension (L*W*H)530*320*235 mm for GK3000-4T0300G/ 555*310*260 for GK3000-2T0300G
I/O FeatureRated current60A at 380V ~ 480V, 112A at 220V ~ 240V
Input voltage3 phase 230V /420V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40 ℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive advantage in injection molding machine energy saving retrofit
For the plastic products industry, power consumption is the main part of production cost, and injection molding machine is the main energy consumption equipment. At present, most of the injection molding machine is hydraulic transmission type, the power in hydraulic system is offered by the motor driven pump. During the injection molding cycle, the flow and pressure required for injection molding machines different processes are different under, and must be dependent on the flow valve and pressure valve to adjust the flow and pressure required for different processes. Hydraulic system has high load changes, because the quantitative pump can't adjust the output power, so the excess energy can only be consumed in the baffle, oil leakage, or oil temperature rise. This has exacerbated the wear of valves, too high oil temperature and too large noise, and the mechanical life can also be shorted. And in usually design, the motor design capacity for user pump is much higher than the actual needs, resulting in a lot of energy waste. Therefore, the promotion of AC variable frequency speed control device in the application of injection molding machine has great significance for reducing energy waste and saving production cost.
The VFD has incomparable advantages in the energy-saving retrofit of injection molding machine. When injection molding machine in frequency conversion retrofit wiring, retain the original computer control system, oil-line of hydraulic transmission system and motor Y-△ step-down start running circuit unchanged. And use variable frequency energy-saving / frequency operation conversion control mode to avoid affecting the normal production when failure occurred. When replacing the mold, only need to change the injection molding machine computer board working procedures, and don’t need to make any adjustments to the VFD.

Product reviews
Can one VFD run multiple motors?
5
Baker
Avatar
7/26/2021 9:30 PM
Can 1 controller run multiple motors? Ie, a 2 hp unit run 4, 1/2 hp fan motors?
Was this review helpful? Yes No (0/0)
ATO Responded
It can be, but all motors should be switched on/off together at the same instant via VFD buttons only, and you have to use 3hp VFD to run 4, 1/2 hp fan motors. But We recommend using one drive for one motor.
I need some help to solve VFD
5
greer
Avatar
7/20/2023 3:58 AM
Installed Gk3000-4T0300G.
The system started up and ran well yesterday.
Came in this morning and started up the system and today we are seeing motor speed not constant and varying downward. And then going out with an E-10 fault.
I need some help.
Was this review helpful? Yes No (0/0)
ATO Responded
What parameters did you set?
Please provide the motor nameplate and wiring diagram for further confirmation.
You can refer to the manual settings.
Manual: https://www.ato.com/Content/doc/ato-gk3000-series-vfd-user-manual.pdf
https://www.ato.com/Content/doc/VFD-quick-setup-manual-and-application.pdf
How to solve VFD problem?
5
janaya
Avatar
7/20/2023 6:53 PM
I purchased 4 VFDs last week installed them and am having an issue with one of them. Would really like a call to address this issue.
We are having issues with an installation of a 15 HP VFD.
The output to our motor is causing the motor to pulse and can not get to steady out. Am I missing something?
3-phase input and output 480V system.
After a few minutes, we are seeing E-10.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for contacting us and sorry for keeping you waiting.
1. Gk3000-4T0300G shows fault code E-10 because the motor is overloaded.
Please send us your motor nameplate label to further confirm whether the motor and VFD match.
Also, you can set P0.22=2 or 3, P0.17=20, P0.18=20, P5.01=120%, P5.04= 180%, and test again.
2. If there is still a problem, please send us a picture of the VFD&motor nameplate label for further confirmation.
It is important for us to figure out a solution. Thank you for your understanding.
3. Please send us the start-up running video to us for further confirmation, the video should show the running status of VFD and motor. You can send us the large video file via wetransfer.com.
Also, you can refer to our demonstration video, please see: https://www.youtube.com/watch?v=nBUm4i9wnzY&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=12&t=101s
We are very concerned about the problems our your encounter, and to be not worried, we will do our best to meet your needs.
What is the default output voltage while running at 50Hz?
5
lily
Avatar
9/4/2023 2:51 AM
I have a VFD model GK3000-4TO300G. I am aware the default setting for the Hz is 50Hz and that is what I need but I need a maximum of 400V.
What is the default output voltage while running at 50Hz?
Was this review helpful? Yes No (0/0)
ATO Responded
Whether it is possible for your VFD output to reach 400V depends on the specific voltage when you purchase it.
Please provide us with the order number to further confirm what product you purchased. We hope to provide you with better service.
We need to know the exact model and parameters of the product you purchased in order to give you the correct advice, thank you for your understanding.
You can also send pictures and nameplates of the products to us for further confirmation.
I have the issue resolved with the three wire start stop wiring
5
Bruce
Avatar
10/24/2023 2:12 AM
I have the issue resolved with the three wire start stop wiring. I still am having an issue with the E-19 input phase loss. I found the parameter pa.12 and changed that setting to 10. The system runs without faulting out buti do not show a current draw on c phase which would be one of the 2 single phase inputs into the phase converter that is manufacturing the third phase. Please advise of the draw backs of turning off the input phase loss setting. Does it change the capability of the drive?
Was this review helpful? Yes No (0/0)
ATO Responded
The input is a three-phase voltage. If there is no correlation or phase loss protection, it does Not matter. It will Not change the driving capability of the VFD.
Only registered users can write reviews
Customers who bought this item also bought

7.5 hp (5.5 kW) VFD, 3 Phase 208V, 380V, 480V

GK3000-4T0055G
$415.08
7.5 hp (5.5 kW) VFD with wholesale price, 3 phase 208V/380V/480V 50Hz/60Hz for option, heavy duty variable frequency drive, 13 amps at 380V ~480V, strong overload capacity, manufacturer direct sale.

25 hp (18.5 kW) VFD, 3 Phase 240V, 420V, 480V

GK3000-4T0185G
$992.18
Favorable price 25 hp (18.5 kW) VFD, three phase 240V, 420V, 480V variable frequency drive, IP20, RS485 enabled, brand new direct sale by Chinese manufacturer with wholesale price.

30 hp (22 kW) VFD, 3 Phase 208V, 440V, 460V

GK3000-4T0220G
$1,264.30
Cheap price 30 hp (22 kW) VFD, three phase 208V, 440V, 460V high performance variable frequency drive, IP20, RS485 enabled, brand new direct sale by manufacturer.

10 hp (7.5 kW) VFD, Three Phase 220V, 440V, 480V

GK3000-4T0075G
$463.25
Affordable 10 hp (7.5 kW) VFD, three phase 220V/440V/480V input for option, three phase output variable frequency drive, 17 amps, V/F & vector control, manufacturer direct sale.

5 hp (3.7 kW) VFD, 3 Phase 230V, 400V, 480V

GK3000-4T0037G
$293.51
Favorable price 5 hp (3.7 / 4 kW) VFD, three phase 230V, 400V, 480V, high performance vector variable frequency drive, IP20 enclosure, RS485 enabled, brand new direct sale by manufacturer.