60 hp (45 kW) VFD, 3 Phase 240V, 380V, 480V

$2,193.10
Affordable 60 hp (45 kW) VFD, three phase 240V, 380V, 480V energy saving variable frequency drive with high performance, brand new direct sale by Chinese manufacturer with fast delivery.
SKU: GK3000-4T0450G
Free Shipping
Delivery date: 6-12 days

60 hp (45 kW) high quality variable frequency drive, three phase 240V, 380V, 480V for selection, IP20.

Specification:

BasicsModelGK3000-4T0450G/ GK3000-2T0450G
Capacity60 hp (45 kW)
Shipping weight31 kg
Dimension555*310*260 mm for GK3000-4T0450G/ 650*400*300 for GK3000-2T0450G
I/O FeatureRated current91A at 380V ~ 480V, 176A at 220V ~ 240V
Input voltage3 phase 240V /380V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive storage notifications
If the VFD is not used for long periods of time, it may be damaged, which is caused by the environmental conditions that do not meet the storage conditions of the VFD. Therefore, the VFD should be placed in the packing case when stored, and note the following:

  1. It is the best to store in absence of sun, no dust and dry place.
  2. The ambient temperature is best in the range of -20~40℃.
  3. The relative humidity is best in the range of 20% to 90%, without condensation.
  4. Avoid long-term storage in corrosive gases and liquids environment.
  5. Long term storage (2-3 years) will lead to electrolytic capacitor degradation. Adding voltage can self-repair certain degree of deterioration. In long-term storage, it should be regularly (within 6 months) powered on for at least 5 hours, and the input voltage should be gradually raised to the rated value by voltage regulator. If the storage period is more than 10 years, the electrolytic capacitors rubber sealed will lose efficacy and must be replaced.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
Motor shaft voltage
5
Guest
Avatar
6/5/2017 8:05 PM
In my option, it depends on the horsepower of the motor. The costs of motor under 60 hp doesn't not justify insulating either bearing. 75 hp (360 frames) to the end of t frames roughly 250 hp in a 4 pole, i would just insulating one bearing. Everything after t frames I would insulate both bearing if being used on a VFD. After 2000 hp I would insulate and add a shaft grounding ring for insurance. The level of protection must be weighted against how critical the motor is, and the costs of the protection versus the costs of replacement/time to reorder.
Was this review helpful? Yes No (0/0)
ATO Responded
If you need a motor rated at 3000rpm minimum and a torque of 30Nm, then the power of the motor must be at least 10kW, and the voltage needs to be 72V or 96V to meet your requirements.
If you want newer motor power and 24V voltage, the motor also needs to be equipped with a planetary reducer.
VFD heat generation
5
Vered
Avatar
3/17/2025 7:17 PM
What is the heat generation of this VFD?
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, we are unable to provide specific heat data for the VFD at this time.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

60 hp (45 kW) high quality variable frequency drive, three phase 240V, 380V, 480V for selection, IP20.

Specification:

BasicsModelGK3000-4T0450G/ GK3000-2T0450G
Capacity60 hp (45 kW)
Shipping weight31 kg
Dimension555*310*260 mm for GK3000-4T0450G/ 650*400*300 for GK3000-2T0450G
I/O FeatureRated current91A at 380V ~ 480V, 176A at 220V ~ 240V
Input voltage3 phase 240V /380V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive storage notifications
If the VFD is not used for long periods of time, it may be damaged, which is caused by the environmental conditions that do not meet the storage conditions of the VFD. Therefore, the VFD should be placed in the packing case when stored, and note the following:

  1. It is the best to store in absence of sun, no dust and dry place.
  2. The ambient temperature is best in the range of -20~40℃.
  3. The relative humidity is best in the range of 20% to 90%, without condensation.
  4. Avoid long-term storage in corrosive gases and liquids environment.
  5. Long term storage (2-3 years) will lead to electrolytic capacitor degradation. Adding voltage can self-repair certain degree of deterioration. In long-term storage, it should be regularly (within 6 months) powered on for at least 5 hours, and the input voltage should be gradually raised to the rated value by voltage regulator. If the storage period is more than 10 years, the electrolytic capacitors rubber sealed will lose efficacy and must be replaced.
Product reviews
Motor shaft voltage
5
Guest
Avatar
6/5/2017 8:05 PM
In my option, it depends on the horsepower of the motor. The costs of motor under 60 hp doesn't not justify insulating either bearing. 75 hp (360 frames) to the end of t frames roughly 250 hp in a 4 pole, i would just insulating one bearing. Everything after t frames I would insulate both bearing if being used on a VFD. After 2000 hp I would insulate and add a shaft grounding ring for insurance. The level of protection must be weighted against how critical the motor is, and the costs of the protection versus the costs of replacement/time to reorder.
Was this review helpful? Yes No (0/0)
ATO Responded
If you need a motor rated at 3000rpm minimum and a torque of 30Nm, then the power of the motor must be at least 10kW, and the voltage needs to be 72V or 96V to meet your requirements.
If you want newer motor power and 24V voltage, the motor also needs to be equipped with a planetary reducer.
VFD heat generation
5
Vered
Avatar
3/17/2025 7:17 PM
What is the heat generation of this VFD?
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, we are unable to provide specific heat data for the VFD at this time.
Only registered users can write reviews
Customers who bought this item also bought

40 hp (30 kW) VFD, 3 Phase 230V, 420V, 480V

GK3000-4T0300G
$1,497.31
High quality 40 hp (30 kW) VFD with low cost, three phase 230V, 420V, 480V variable frequency drive with good performance, brand new direct sale by manufacturer.