50 hp (37 kW) VFD, 3 Phase 220V, 400V, 460V

$1,781.14
Discounted 50 hp (37 kW) VFD, three phase 220V, 400V, 460V energy saving variable frequency drive for motor speed controls, strong overload capacity, brand new direct sale by manufacturer with fast delivery.
SKU: GK3000-4T0370G
Free Shipping
Delivery date: 6-12 days

50 hp (37 kW) variable frequency drive for energy savings, three phase 220V, 400V, 460V for selection, RS485 enabled.

Specification:

BasicsModelGK3000-4T0370G/ GK3000-2T0370G
Capacity50 hp (37 kW)
Shipping weight22 kg
Dimension530*320*235 mm for GK3000-4T0370G/ 555*400*300 for GK3000-2T0370G
I/O FeatureRated current75A at 380V ~ 480V, 150A at 220V ~ 240V
Input voltage3 phase 220V /400V /460V AC ±15% (Optional)
Input frequency50 Hz / 60 Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive service life extension methods

  1. Do not install the VFD on vibration device, because the main circuit connecting screws will be easy to loose and causing damage.
  2. Wiring problem: The VFD input is best to be connected to an air switch to control the current value and to prevent the occurrence of short circuit. The "N" end must not be grounded. Control line should not be too long. Because this makes the control board is easily disturbed by electromagnetic interference and occur malfunction, which will lead to control board damage. The control line more than 2 meters is best to use shielded wire. Do not install a large current and frequent operating contactor next to the VFD, because it has strong disturbance and often causing malfunction (show all kinds of faults).
  3. Frequent emergency stop VFD is best not to rely on the built-in brake device, but to install additional brake resistance or mechanical brake, or the VFD will often backlash impacted by the motor counter electromotive force, the failure rate will be greatly increased.
  4. If the VFD is often running at low speed below 15HZ, the motor should be attached to the cooling fan.
  5. Dust and moisture are the most deadly killers of the variable frequency drive. It is best to install the VFD in the air-conditioned room, or installed in the cabinet with strainer mesh, and to regularly clean the dust of circuit board and the heat sink. If a VFD is not in used for a long time, use a hair dryer to blow the circuit board before restarting.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
Can ATO provide me with the VFD I want?
5
Appoli
Avatar
6/15/2021 9:55 PM
Can you provide a VFD for 7.5 Hp, 240 V single phase motor.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can. GK3000-1S0075G, 10HP drive with output current of 50A.
Certifications/Listings
4
Tyler
Avatar
4/23/2024 2:56 PM
Is this UL(or other American listing agency)?
Was this review helpful? Yes No (0/0)
ATO Responded
ATO VFDs are only CE certified.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

50 hp (37 kW) variable frequency drive for energy savings, three phase 220V, 400V, 460V for selection, RS485 enabled.

Specification:

BasicsModelGK3000-4T0370G/ GK3000-2T0370G
Capacity50 hp (37 kW)
Shipping weight22 kg
Dimension530*320*235 mm for GK3000-4T0370G/ 555*400*300 for GK3000-2T0370G
I/O FeatureRated current75A at 380V ~ 480V, 150A at 220V ~ 240V
Input voltage3 phase 220V /400V /460V AC ±15% (Optional)
Input frequency50 Hz / 60 Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive service life extension methods

  1. Do not install the VFD on vibration device, because the main circuit connecting screws will be easy to loose and causing damage.
  2. Wiring problem: The VFD input is best to be connected to an air switch to control the current value and to prevent the occurrence of short circuit. The "N" end must not be grounded. Control line should not be too long. Because this makes the control board is easily disturbed by electromagnetic interference and occur malfunction, which will lead to control board damage. The control line more than 2 meters is best to use shielded wire. Do not install a large current and frequent operating contactor next to the VFD, because it has strong disturbance and often causing malfunction (show all kinds of faults).
  3. Frequent emergency stop VFD is best not to rely on the built-in brake device, but to install additional brake resistance or mechanical brake, or the VFD will often backlash impacted by the motor counter electromotive force, the failure rate will be greatly increased.
  4. If the VFD is often running at low speed below 15HZ, the motor should be attached to the cooling fan.
  5. Dust and moisture are the most deadly killers of the variable frequency drive. It is best to install the VFD in the air-conditioned room, or installed in the cabinet with strainer mesh, and to regularly clean the dust of circuit board and the heat sink. If a VFD is not in used for a long time, use a hair dryer to blow the circuit board before restarting.
Product reviews
Can ATO provide me with the VFD I want?
5
Appoli
Avatar
6/15/2021 9:55 PM
Can you provide a VFD for 7.5 Hp, 240 V single phase motor.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can. GK3000-1S0075G, 10HP drive with output current of 50A.
Certifications/Listings
4
Tyler
Avatar
4/23/2024 2:56 PM
Is this UL(or other American listing agency)?
Was this review helpful? Yes No (0/0)
ATO Responded
ATO VFDs are only CE certified.
Only registered users can write reviews