10 kVA static frequency converter (AC power supply), convert 50Hz to 60Hz, also change 220V/230V/240V (e.g. China) to 110V/120V (e.g. Hawaii), reliable power frequency changer, manufacturer direct sales.
Specification:
| Model | HZ-50-1110 | |
| Capacity | 10 kVA | |
| Dimension | 680 (D)*500 (W)*970 (H) mm | |
| Weight | 130 kg | |
| Input | Voltage | 1 Phase 2 Wire: 110V, 120V, 220V, 230V, 240V ± 10% (Option *) |
| Frequency | 50 Hz, 60 Hz | |
| Output | Voltage, current | 110V Setting (Low grade): 0-150V, 83.2A |
| 220V Setting 0-300V (High grade): 0-300V, 41.6A | ||
| Load stabilization Rate | ≤±1% | |
| Frequency | 50Hz, 60Hz up to 400Hz adjustable Note: -When the output is 400Hz, the load capacity can only reach 50% of the rated capacity. -When the output is ≤120Hz, the load capacity can reach 100% of the rated value. -You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option. | |
| Frequency Stability | ≤±0.01% | |
| Harmonic Distortion | Pure Sine Wave ≤2% | |
| Frequency meter | 4 digit, digital frequency meter, resolution 0.1Hz/Step | |
| Voltmeter | 4 digit, digital voltage meter, resolution 0.1V | |
| Ammeter | 4 digit, digital ammeter, resolution 0.1A | |
| Watt meter | 4 digit, digital Watt meter, resolution 0.1W | |
| Protection | With overload, short circuit, over temperature | |
| Instantaneous power failure protection and alarm device | ||
| Working Environment | Temperature | 0 - 40 deg.℃ |
| Humidity | 0 - 90% (Non condensation) | |
| Warranty | 18 months | |
Wiring and Testing a Single Cabinet Frequency Converter
Here is a video about the operating steps of the cabinet frequency converter. This video gives a rundown of how to wire and test a 1 single cabinet frequency converter using a multimeter.
Tips: The difference between VFD and frequency converter
- Variable frequency drive conforms to the speed regulation characteristics of the motor. One single set of VFD can only be equipped with one motor, so that it can not be used as the power source.
- Frequency converter simulates the power grid to supply electricity, and is superior to the grid quality.
- The VFD output the impulse wave, has high harmonic wave but no sine wave, which can cause the abnormality of the load control circuit.
- The output of AC frequency converter equipped with isolation transformer, inductance, and capacitor filtering, outputs pure sine wave.
Product reviews
Item received
Johan
7/4/2019 3:40 AM
Input 230V 50Hz and output 110V 60Hz converter, we use this unit to test some US kitchen ovens, it works great. ATO answered all my questions. Professional and reliable!
Was this review helpful? (0/0)
High quality frequency converter
Mchappy
8/13/2021 12:23 AM
We need a converter that can do the following: Input is 220 V / 60 HZ. Needed output single-phase 220V/50 HZ. The converter will support the power needed for a calibration lab device that draws peak current (approximately 17 amp). The device is susceptible to frequency instability, hence the converter output should be stable.
Was this review helpful? (0/0)
The specifications of the frequency converter we need
Denisey
9/9/2021 12:00 AM
The customer needs remote control as per the following specs:
Remote operator station
Able to be installed electrically where the remote operator’s station wire(s) length would be greater than 50ft but no more than 200ft.
Remote operator station requirements (REDUNDANT CONTROLS OF MAIN UNIT):
REMOTE CONTROL INDICATORS: Display converter status, system faults, power on, converteron, voltage output, current output, and frequency output.
REMOTE CONTROLS: Start, stop / reset, output status, and emergency stop.
Remote operator station
Able to be installed electrically where the remote operator’s station wire(s) length would be greater than 50ft but no more than 200ft.
Remote operator station requirements (REDUNDANT CONTROLS OF MAIN UNIT):
REMOTE CONTROL INDICATORS: Display converter status, system faults, power on, converteron, voltage output, current output, and frequency output.
REMOTE CONTROLS: Start, stop / reset, output status, and emergency stop.
Was this review helpful? (0/0)
We need a frequency converter with the following performance
Kate
10/8/2021 7:44 PM
Do you provide a converter with the following specs? We need input 240V 50 Hz & output 120V, 60 Hz. Capacity 1 kVA.
Was this review helpful? (0/0)
We need a frequency converter with the following specs
Rosie
10/18/2021 8:01 PM
Input voltage: 220VAC 50 Hz.
Output voltage: 1-115 VAC (Adjustable Voltage Range)
Output frequency: 400 Hertz
Output power: 500-1000 Watts. What do you recommend?
Output voltage: 1-115 VAC (Adjustable Voltage Range)
Output frequency: 400 Hertz
Output power: 500-1000 Watts. What do you recommend?
Was this review helpful? (0/0)
I am interested in your single-phase frequency converter
Icona
11/21/2021 7:15 PM
I'm interested in a single phase frequency converter: 240V 50Hz -> 400Hz, 5KVA. Can you provide it?
Was this review helpful? (0/0)
For your frequency converter
Rachelc
12/29/2021 6:21 PM
For your frequency converter; Is this 480V ( /- 10%) correct for Delta configuration, because the facility is running consistently between 490 to 500 V?
Was this review helpful? (0/0)
I have a couple of questions for you concerning the 10kVA unit we purchased from ATO.
Devin
5/26/2022 3:20 AM
1. When we slightly touch the Phase Switch but keep it at a fixed phase, either at U or V or W that the current readings and hence, the power readings fluctuate by a few hundred mA and a few Watts? How can that problem be corrected?
2. I don’t understand what the information on the display is showing because the phase current shown and voltage shown when multiplied together should equal the Watts shown? For instance, 115V is shown and 11.41A is shown as well as 1205W is shown. So 115V*11.41A = 1312W. Can you help me understand how to read the data on the display?
3. What is the function of the black toggle switch next to the amber light beneath the input and output breakers on the front lower section of the unit? The User Manual makes no mention of this. When I turn that switch ON, the amber light comes ON and the power consumption figures at the display increase. When I turn that switch OFF, the amber light turns OFF and power dissipation at the display decreases. I don’t understand what this is.
2. I don’t understand what the information on the display is showing because the phase current shown and voltage shown when multiplied together should equal the Watts shown? For instance, 115V is shown and 11.41A is shown as well as 1205W is shown. So 115V*11.41A = 1312W. Can you help me understand how to read the data on the display?
3. What is the function of the black toggle switch next to the amber light beneath the input and output breakers on the front lower section of the unit? The User Manual makes no mention of this. When I turn that switch ON, the amber light comes ON and the power consumption figures at the display increase. When I turn that switch OFF, the amber light turns OFF and power dissipation at the display decreases. I don’t understand what this is.
Was this review helpful? (0/0)
Having an issue of single phase converter
kourtney
6/15/2023 11:50 PM
We purchased your 10kVA frequency converter in September of last year.
We are having an issue where the output voltage will drift up and down without moving the knob.
In the video attached I have an example of it drifting between 110 volt and 140 volt over 30 seconds.
Please advise if there is a potential cause for this.
The voltage supplied to the unit is steady.
Thanks.
We are having an issue where the output voltage will drift up and down without moving the knob.
In the video attached I have an example of it drifting between 110 volt and 140 volt over 30 seconds.
Please advise if there is a potential cause for this.
The voltage supplied to the unit is steady.
Thanks.
Was this review helpful? (0/0)
About the converter
Elodie
7/10/2024 2:42 AM
We will use HZ-50-1110 converter to feed high generated harmonics load. By experience with other frequency convertors, we realize this specific load generate the effect of "harmonic distortion" and that result of capacitors overheating inside of converter unit after 3 minutes of operation. What do you think about the converter? Will it work fine?
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
3kVA Single Phase 220v 50Hz to 110v 60Hz Converter
HZ-50-1103
$2,623.61
3 kVA frequency converter, convert single phase 220V (France) 230V (New Zealand) 240V (UK) to 110V (Mexico) 120V (Canada), 60 Hz to 50 Hz or 50Hz to 60Hz, pure sine wave output, make different appliances work well on 50Hz/60Hz/400Hz power system.
7.5 hp VFD, Single Phase 120V Input, 1ph/3ph 220V Output
GK3000-SP1S1-5d5
$453.86
7.5 hp variable frequency drive, single phase 120v input, single phase and three phase 220v output, running AC motor on single phase 110v/120v power supply, manufacturer direct sale.
45kVA 3-Phase 480v 60Hz/400v 50Hz Frequency Converter
HZ-50-3345
$13,670.41
Affordable 45 kVA static frequency converter, built-in step-down/step-up transformer, convert 3 phase 480V 60Hz (e.g. US) to 400V 50Hz (e.g. Israel), 380V 50Hz (e.g. Germany), also change 3-phase 220V 60Hz to 380V/400V 50Hz in one step.