10kVA Single Phase 240v 50Hz to 120v 60Hz Converter

$4,676.59
10 kVA 1 phase solid state frequency converter, change 240V 50Hz to 120V 60Hz (vice versa), step up and step down frequency & voltage, supply high quality output electricity for test lab & production facilities.
SKU: HZ-50-1110
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-16 days

10 kVA static frequency converter (AC power supply), convert 50Hz to 60Hz, also change 220V/230V/240V (e.g. China) to 110V/120V (e.g. Hawaii), reliable power frequency changer, manufacturer direct sales.

Specification:

ModelHZ-50-1110
Capacity10 kVA
Dimension680 (D)*500 (W)*970 (H) mm
Weight130 kg
InputVoltage1 Phase 2 Wire: 110V, 120V, 220V, 230V, 240V ± 10% (Option *)
Frequency50 Hz, 60 Hz
OutputVoltage, current110V Setting (Low grade): 0-150V, 83.2A
220V Setting 0-300V (High grade): 0-300V, 41.6A
Load stabilization Rate≤±1%
Frequency50Hz, 60Hz up to 400Hz adjustable
Note:
-When the output is 400Hz, the load capacity can only reach 50% of the rated capacity.
-When the output is ≤120Hz, the load capacity can reach 100% of the rated value.
-You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option.
Frequency Stability≤±0.01%
Harmonic DistortionPure Sine Wave ≤2%
Frequency meter4 digit, digital frequency meter, resolution 0.1Hz/Step
Voltmeter4 digit, digital voltage meter, resolution 0.1V
Ammeter4 digit, digital ammeter, resolution 0.1A
Watt meter4 digit, digital Watt meter, resolution 0.1W
ProtectionWith overload, short circuit, over temperature
Instantaneous power failure protection and alarm device
Working EnvironmentTemperature0 - 40 deg.℃
Humidity0 - 90% (Non condensation)
Warranty18 months

Wiring and Testing a Single Cabinet Frequency Converter

Here is a video about the operating steps of the cabinet frequency converter. This video gives a rundown of how to wire and test a 1 single cabinet frequency converter using a multimeter.

Tips: The difference between VFD and frequency converter

  1. Variable frequency drive conforms to the speed regulation characteristics of the motor. One single set of VFD can only be equipped with one motor, so that it can not be used as the power source.
  2. Frequency converter simulates the power grid to supply electricity, and is superior to the grid quality.
  3. The VFD output the impulse wave, has high harmonic wave but no sine wave, which can cause the abnormality of the load control circuit.
  4. The output of AC frequency converter equipped with isolation transformer, inductance, and capacitor filtering, outputs pure sine wave.

MOS Tube Testing in a Frequency Converter

In this video, we first show you the internal structure of our frequency converter, so that you know the exact location of the MOS tube in the converter, and then we use a multimeter to test these tubes in diode mode and ohm range respectively. In the process, we also explain to you how to judge the condition of the equipment.

Frequency Converter Troubleshooting: CBB65 Capacitor Testing

This video will walk you through the steps of how to test the CBB65 capacitor in a frequency converter using a multimeter.

Frequency Converter Driver Board Test

This is one of the ATO single-phase frequency converter repair tutorial series. In this video, we show you how to simply test the driver board in the variable frequency power supply using a multimeter.

Pre-maintenance preparation of frequency converters

In this presentation, we show you the maintenance preparation procedure for an ATO single-phase frequency converter (cabinet version), specifically, involving the disconnection of the internal bridge rectifier.

Product reviews
Item received
5
Johan
Avatar
7/4/2019 3:40 AM
Input 230V 50Hz and output 110V 60Hz converter, we use this unit to test some US kitchen ovens, it works great. ATO answered all my questions. Professional and reliable!
Was this review helpful? Yes No (0/0)
High quality frequency converter
5
Mchappy
Avatar
8/13/2021 12:23 AM
We need a converter that can do the following: Input is 220 V / 60 HZ. Needed output single-phase 220V/50 HZ. The converter will support the power needed for a calibration lab device that draws peak current (approximately 17 amp). The device is susceptible to frequency instability, hence the converter output should be stable.
Was this review helpful? Yes No (0/0)
The specifications of the frequency converter we need
5
Denisey
Avatar
9/9/2021 12:00 AM
The customer needs remote control as per the following specs:
Remote operator station
Able to be installed electrically where the remote operator’s station wire(s) length would be greater than 50ft but no more than 200ft.
Remote operator station requirements (REDUNDANT CONTROLS OF MAIN UNIT):
REMOTE CONTROL INDICATORS: Display converter status, system faults, power on, converteron, voltage output, current output, and frequency output.
REMOTE CONTROLS: Start, stop / reset, output status, and emergency stop.
Was this review helpful? Yes No (0/0)
ATO Responded
Our converter remote controller can only do the following functions, it controls the converter by a remote control box: start, stop/reset, voltage output, frequency output (50/60Hz), and the line length is only 10 meters long.
At present, the factory has not renewed the remote control function.
It means that you can adjust converter output voltage and frequency remotely via the control box in the ranges (0-300V)/(0-150V) for 1-phase, and (0-520V)/(0-260V) for 3- phase, and the frequency in the range (40-99Hz), not (100-499.9Hz).
This is equivalent to configuring an additional operation panel for the customer.
We need a frequency converter with the following performance
5
Kate
Avatar
10/8/2021 7:44 PM
Do you provide a converter with the following specs? We need input 240V 50 Hz & output 120V, 60 Hz. Capacity 1 kVA.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, model: HZ-60-1101, 1kVA power capacity, input: 1ph, 240V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable (0-150V), adjustable (40-120Hz), 8.4A.
We need a frequency converter with the following specs
5
Rosie
Avatar
10/18/2021 8:01 PM
Input voltage: 220VAC 50 Hz.
Output voltage: 1-115 VAC (Adjustable Voltage Range)
Output frequency: 400 Hertz
Output power: 500-1000 Watts. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, recommended frequency converter model: HZ-50-1115, 15kVA power capacity, input: 1ph, 220V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable (0-150V ), adjusted (40-499.9Hz), 125A.
I am interested in your single-phase frequency converter
5
Icona
Avatar
11/21/2021 7:15 PM
I'm interested in a single phase frequency converter: 240V 50Hz -> 400Hz, 5KVA. Can you provide it?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, recommended frequency converter model: HZ-50-1105, 5kVA power capacity, input: 1ph, 240V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable (0-300V )/(0-150V), adjustable (40-499.9Hz), 20.8A/41.6A.
For your frequency converter
5
Rachelc
Avatar
12/29/2021 6:21 PM
For your frequency converter; Is this 480V ( /- 10%) correct for Delta configuration, because the facility is running consistently between 490 to 500 V?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, 480V (+/- 10%) is correct for Delta configuration, and 490 to 500V is okay with no problem at all.
I have a couple of questions for you concerning the 10kVA unit we purchased from ATO.
5
Devin
Avatar
5/26/2022 3:20 AM
1. When we slightly touch the Phase Switch but keep it at a fixed phase, either at U or V or W that the current readings and hence, the power readings fluctuate by a few hundred mA and a few Watts? How can that problem be corrected?
2. I don’t understand what the information on the display is showing because the phase current shown and voltage shown when multiplied together should equal the Watts shown? For instance, 115V is shown and 11.41A is shown as well as 1205W is shown. So 115V*11.41A = 1312W. Can you help me understand how to read the data on the display?
3. What is the function of the black toggle switch next to the amber light beneath the input and output breakers on the front lower section of the unit? The User Manual makes no mention of this. When I turn that switch ON, the amber light comes ON and the power consumption figures at the display increase. When I turn that switch OFF, the amber light turns OFF and power dissipation at the display decreases. I don’t understand what this is.
Was this review helpful? Yes No (0/0)
ATO Responded
Is the data you provide below tested with the connection load?
1. The power of the touch phase switch will change, which should be caused by a little fluctuation of the load when the machine is working. Because the output power is only regulated and frequency-stabilized, the power and current vary according to the load.
2. If you think the power display is inaccurate, it is recommended that you use a clamp ammeter to measure the actual output current to see if the actual current matches the displayed current.
3. This toggle switch adjusts the line voltage and phase voltage (with an indicator label next to it). When the amber light is on, the line voltage is displayed. If the amber light is turned off, the phase voltage is displayed. The line voltage must be higher than the phase voltage, for example, the phase voltage 115v*1.732 is equal to the line voltage 119.18v.
Having an issue of single phase converter
5
kourtney
Avatar
6/15/2023 11:50 PM
We purchased your 10kVA frequency converter in September of last year.
We are having an issue where the output voltage will drift up and down without moving the knob.
In the video attached I have an example of it drifting between 110 volt and 140 volt over 30 seconds.
Please advise if there is a potential cause for this.
The voltage supplied to the unit is steady.
Thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
Regarding the issue of output voltage will drift up, please use a multi meter to measure the actual output terminal voltage.
If the actual measured output voltage does not fluctuate (normal), it may be a problem with the display board.
If the actual output is fluctuating as shown, it may be a problem with the driver board.
Please measure the voltage at the output terminal and feedback the measurement result to us. Thank you for your understanding.
You can send us the large video file via wetransfer.com.
About the converter
5
Elodie
Avatar
7/10/2024 2:42 AM
We will use HZ-50-1110 converter to feed high generated harmonics load. By experience with other frequency convertors, we realize this specific load generate the effect of "harmonic distortion" and that result of capacitors overheating inside of converter unit after 3 minutes of operation. What do you think about the converter? Will it work fine?
Was this review helpful? Yes No (0/0)
ATO Responded
The circuit board capacitor caused heating due to harmonic distortion. We believe that this is caused by the harmonic rate of the switching power board design or the circuit board structure. When our converter drives the load, the harmonic distortion rate is controlled within 2%, voltage output stable. It can be used normally on this bowl feeder load. The 10KVA capacity is also sufficient. Because our capacitor size is larger at 10KVA, the heat will be small.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

10 kVA static frequency converter (AC power supply), convert 50Hz to 60Hz, also change 220V/230V/240V (e.g. China) to 110V/120V (e.g. Hawaii), reliable power frequency changer, manufacturer direct sales.

Specification:

ModelHZ-50-1110
Capacity10 kVA
Dimension680 (D)*500 (W)*970 (H) mm
Weight130 kg
InputVoltage1 Phase 2 Wire: 110V, 120V, 220V, 230V, 240V ± 10% (Option *)
Frequency50 Hz, 60 Hz
OutputVoltage, current110V Setting (Low grade): 0-150V, 83.2A
220V Setting 0-300V (High grade): 0-300V, 41.6A
Load stabilization Rate≤±1%
Frequency50Hz, 60Hz up to 400Hz adjustable
Note:
-When the output is 400Hz, the load capacity can only reach 50% of the rated capacity.
-When the output is ≤120Hz, the load capacity can reach 100% of the rated value.
-You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option.
Frequency Stability≤±0.01%
Harmonic DistortionPure Sine Wave ≤2%
Frequency meter4 digit, digital frequency meter, resolution 0.1Hz/Step
Voltmeter4 digit, digital voltage meter, resolution 0.1V
Ammeter4 digit, digital ammeter, resolution 0.1A
Watt meter4 digit, digital Watt meter, resolution 0.1W
ProtectionWith overload, short circuit, over temperature
Instantaneous power failure protection and alarm device
Working EnvironmentTemperature0 - 40 deg.℃
Humidity0 - 90% (Non condensation)
Warranty18 months

Wiring and Testing a Single Cabinet Frequency Converter

Here is a video about the operating steps of the cabinet frequency converter. This video gives a rundown of how to wire and test a 1 single cabinet frequency converter using a multimeter.

Tips: The difference between VFD and frequency converter

  1. Variable frequency drive conforms to the speed regulation characteristics of the motor. One single set of VFD can only be equipped with one motor, so that it can not be used as the power source.
  2. Frequency converter simulates the power grid to supply electricity, and is superior to the grid quality.
  3. The VFD output the impulse wave, has high harmonic wave but no sine wave, which can cause the abnormality of the load control circuit.
  4. The output of AC frequency converter equipped with isolation transformer, inductance, and capacitor filtering, outputs pure sine wave.

Product reviews
Item received
5
Johan
Avatar
7/4/2019 3:40 AM
Input 230V 50Hz and output 110V 60Hz converter, we use this unit to test some US kitchen ovens, it works great. ATO answered all my questions. Professional and reliable!
Was this review helpful? Yes No (0/0)
High quality frequency converter
5
Mchappy
Avatar
8/13/2021 12:23 AM
We need a converter that can do the following: Input is 220 V / 60 HZ. Needed output single-phase 220V/50 HZ. The converter will support the power needed for a calibration lab device that draws peak current (approximately 17 amp). The device is susceptible to frequency instability, hence the converter output should be stable.
Was this review helpful? Yes No (0/0)
The specifications of the frequency converter we need
5
Denisey
Avatar
9/9/2021 12:00 AM
The customer needs remote control as per the following specs:
Remote operator station
Able to be installed electrically where the remote operator’s station wire(s) length would be greater than 50ft but no more than 200ft.
Remote operator station requirements (REDUNDANT CONTROLS OF MAIN UNIT):
REMOTE CONTROL INDICATORS: Display converter status, system faults, power on, converteron, voltage output, current output, and frequency output.
REMOTE CONTROLS: Start, stop / reset, output status, and emergency stop.
Was this review helpful? Yes No (0/0)
ATO Responded
Our converter remote controller can only do the following functions, it controls the converter by a remote control box: start, stop/reset, voltage output, frequency output (50/60Hz), and the line length is only 10 meters long.
At present, the factory has not renewed the remote control function.
It means that you can adjust converter output voltage and frequency remotely via the control box in the ranges (0-300V)/(0-150V) for 1-phase, and (0-520V)/(0-260V) for 3- phase, and the frequency in the range (40-99Hz), not (100-499.9Hz).
This is equivalent to configuring an additional operation panel for the customer.
We need a frequency converter with the following performance
5
Kate
Avatar
10/8/2021 7:44 PM
Do you provide a converter with the following specs? We need input 240V 50 Hz & output 120V, 60 Hz. Capacity 1 kVA.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, model: HZ-60-1101, 1kVA power capacity, input: 1ph, 240V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable (0-150V), adjustable (40-120Hz), 8.4A.
We need a frequency converter with the following specs
5
Rosie
Avatar
10/18/2021 8:01 PM
Input voltage: 220VAC 50 Hz.
Output voltage: 1-115 VAC (Adjustable Voltage Range)
Output frequency: 400 Hertz
Output power: 500-1000 Watts. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, recommended frequency converter model: HZ-50-1115, 15kVA power capacity, input: 1ph, 220V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable (0-150V ), adjusted (40-499.9Hz), 125A.
I am interested in your single-phase frequency converter
5
Icona
Avatar
11/21/2021 7:15 PM
I'm interested in a single phase frequency converter: 240V 50Hz -> 400Hz, 5KVA. Can you provide it?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, recommended frequency converter model: HZ-50-1105, 5kVA power capacity, input: 1ph, 240V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable (0-300V )/(0-150V), adjustable (40-499.9Hz), 20.8A/41.6A.
For your frequency converter
5
Rachelc
Avatar
12/29/2021 6:21 PM
For your frequency converter; Is this 480V ( /- 10%) correct for Delta configuration, because the facility is running consistently between 490 to 500 V?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, 480V (+/- 10%) is correct for Delta configuration, and 490 to 500V is okay with no problem at all.
I have a couple of questions for you concerning the 10kVA unit we purchased from ATO.
5
Devin
Avatar
5/26/2022 3:20 AM
1. When we slightly touch the Phase Switch but keep it at a fixed phase, either at U or V or W that the current readings and hence, the power readings fluctuate by a few hundred mA and a few Watts? How can that problem be corrected?
2. I don’t understand what the information on the display is showing because the phase current shown and voltage shown when multiplied together should equal the Watts shown? For instance, 115V is shown and 11.41A is shown as well as 1205W is shown. So 115V*11.41A = 1312W. Can you help me understand how to read the data on the display?
3. What is the function of the black toggle switch next to the amber light beneath the input and output breakers on the front lower section of the unit? The User Manual makes no mention of this. When I turn that switch ON, the amber light comes ON and the power consumption figures at the display increase. When I turn that switch OFF, the amber light turns OFF and power dissipation at the display decreases. I don’t understand what this is.
Was this review helpful? Yes No (0/0)
ATO Responded
Is the data you provide below tested with the connection load?
1. The power of the touch phase switch will change, which should be caused by a little fluctuation of the load when the machine is working. Because the output power is only regulated and frequency-stabilized, the power and current vary according to the load.
2. If you think the power display is inaccurate, it is recommended that you use a clamp ammeter to measure the actual output current to see if the actual current matches the displayed current.
3. This toggle switch adjusts the line voltage and phase voltage (with an indicator label next to it). When the amber light is on, the line voltage is displayed. If the amber light is turned off, the phase voltage is displayed. The line voltage must be higher than the phase voltage, for example, the phase voltage 115v*1.732 is equal to the line voltage 119.18v.
Having an issue of single phase converter
5
kourtney
Avatar
6/15/2023 11:50 PM
We purchased your 10kVA frequency converter in September of last year.
We are having an issue where the output voltage will drift up and down without moving the knob.
In the video attached I have an example of it drifting between 110 volt and 140 volt over 30 seconds.
Please advise if there is a potential cause for this.
The voltage supplied to the unit is steady.
Thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
Regarding the issue of output voltage will drift up, please use a multi meter to measure the actual output terminal voltage.
If the actual measured output voltage does not fluctuate (normal), it may be a problem with the display board.
If the actual output is fluctuating as shown, it may be a problem with the driver board.
Please measure the voltage at the output terminal and feedback the measurement result to us. Thank you for your understanding.
You can send us the large video file via wetransfer.com.
About the converter
5
Elodie
Avatar
7/10/2024 2:42 AM
We will use HZ-50-1110 converter to feed high generated harmonics load. By experience with other frequency convertors, we realize this specific load generate the effect of "harmonic distortion" and that result of capacitors overheating inside of converter unit after 3 minutes of operation. What do you think about the converter? Will it work fine?
Was this review helpful? Yes No (0/0)
ATO Responded
The circuit board capacitor caused heating due to harmonic distortion. We believe that this is caused by the harmonic rate of the switching power board design or the circuit board structure. When our converter drives the load, the harmonic distortion rate is controlled within 2%, voltage output stable. It can be used normally on this bowl feeder load. The 10KVA capacity is also sufficient. Because our capacitor size is larger at 10KVA, the heat will be small.
Only registered users can write reviews
Customers who bought this item also bought

3kVA Single Phase 220v 50Hz to 110v 60Hz Converter

HZ-50-1103
$2,623.61
3 kVA frequency converter, convert single phase 220V (France) 230V (New Zealand) 240V (UK) to 110V (Mexico) 120V (Canada), 60 Hz to 50 Hz or 50Hz to 60Hz, pure sine wave output, make different appliances work well on 50Hz/60Hz/400Hz power system.

7.5 hp VFD, Single Phase 120V Input, 1ph/3ph 220V Output

GK3000-SP1S1-5d5
$453.86
7.5 hp variable frequency drive, single phase 120v input, single phase and three phase 220v output, running AC motor on single phase 110v/120v power supply, manufacturer direct sale.

45kVA 3-Phase 480v 60Hz/400v 50Hz Frequency Converter

HZ-50-3345
$13,670.41
Affordable 45 kVA static frequency converter, built-in step-down/step-up transformer, convert 3 phase 480V 60Hz (e.g. US) to 400V 50Hz (e.g. Israel), 380V 50Hz (e.g. Germany), also change 3-phase 220V 60Hz to 380V/400V 50Hz in one step.