3 kVA static frequency converter, convert 240 volt 50Hz to 120 volt 60Hz with built-in step-down & step-up transformer, pure sine wave output for international appliances testing.
Specification:
| Model | HZ-50-1103 (Cabinet Type), HZ-60-1103 (Benchtop Type) | |
| Capacity | 3 kVA | |
| Dimension | Benchtop Design | 590 (D)*490 (W)*230 (H) mm |
| Cabinet Design | 550 (D)*400 (W)*670 (H) mm | |
| Weight | Benchtop Design | 51 kg |
| Cabinet Design | 75 kg | |
| Input | Voltage | 1 Phase 2 Wire: 110V, 120V, 220V, 230V, 240V ± 10% (Option *) |
| Frequency | 50 Hz, 60 Hz | |
| Output | Voltage, current | 110V Setting (Low grade): 0-150V, 25A |
| 220V Setting 0-300V (High grade): 0-300V, 12.5A | ||
| Load stabilization Rate | ≤±1% | |
| Frequency | 50Hz, 60Hz up to 400Hz adjustable Note: -When the output is 400Hz, the load capacity can only reach 50% of the rated capacity. -When the output is ≤120Hz, the load capacity can reach 100% of the rated value. -You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option. | |
| Frequency Stability | ≤±0.01% | |
| Harmonic Distortion | Pure Sine Wave ≤2% | |
| Frequency meter | 4 digit, digital frequency meter, resolution 0.1Hz/Step | |
| Voltmeter | 4 digit, digital voltage meter, resolution 0.1V | |
| Ammeter | 4 digit, digital ammeter, resolution 0.1A | |
| Watt meter | 4 digit, digital Watt meter, resolution 0.1W | |
| Protection | With overload, short circuit, over temperature | |
| Instantaneous power failure protection and alarm device | ||
| Working Environment | Temperature | 0 - 40 deg.℃ |
| Humidity | 0 - 90% (Non condensation) | |
| Warranty | 18 months | |
Features and Safe Usage Guide
Here is a video that shows you the main features of ATO single phase frequency converter and how you can use it to effectively and safely power electric equipment.
Tips: Why is 60 Hertz selected for the United States?
Westinghouse, which possesses the strengths in manufacturing and operation AC power supply technology, promotes the higher frequency standard of 60Hz after 1890(frequency standard compared with 25Hz low-frequency AC), which is used till now in the United States. In 1920, the America Federal Government established the electric power investigation meeting, recommending 60 Hz as the standard frequency of the United States.
In 1893, the American GE company planed to adopt 50 Hz to some power supply systems in California according to the frequency standard of Edison system. However, because of the competitive pressure, it eventually yielded to the 60Hz standard of Westinghouse. The American technicians at that time believed that, 60Hz is superior to the 50Hz generally adopted in European countries. The generator of 60Hz has smaller size and the conversion efficiency of the transformer is high.
I have 120V single phase at 60Hz input power, 220V 60Hz split phase ( two 120V hot wires and a ground no neutral) or 3 phase 480V 60Hz power (three hot wires at 277V and a ground).
I need a unit that can run on one of those 3 input options and output 220V single phase at 50Hz. (one 220V hot wire , one neutral wire and a ground)
What do you recommend? Will SKU: HZ-50-1103 work?