5 kVA frequency converter/AC power source, 50Hz 60Hz 400Hz frequency regulator, convert fixed frequency & voltage to variable frequency & voltage for international appliances compatibility.
Specification:
| Model | HZ-50-1105 | |
| Capacity | 5 kVA | |
| Dimension | 550 (D)*400 (W)*670 (H) mm | |
| Weight | 75 kg | |
| Input | Voltage | 1 Phase 2 Wire: 110V, 120V, 220V, 230V, 240V ± 10% (Option *) |
| Frequency | 50 Hz, 60 Hz | |
| Output | Voltage, current | 110V Setting (Low grade): 0-150V, 41.6A |
| 220V Setting 0-300V (High grade): 0-300V, 20.8A | ||
| Load stabilization Rate | ≤±1% | |
| Frequency | 50Hz, 60Hz up to 400Hz adjustable Note: -When the output is 400Hz, the load capacity can only reach 50% of the rated capacity. -When the output is ≤120Hz, the load capacity can reach 100% of the rated value. -You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option. | |
| Frequency Stability | ≤±0.01% | |
| Harmonic Distortion | Pure Sine Wave ≤2% | |
| Frequency meter | 4 digit, digital frequency meter, resolution 0.1Hz/Step | |
| Voltmeter | 4 digit, digital voltage meter, resolution 0.1V | |
| Ammeter | 4 digit, digital ammeter, resolution 0.1A | |
| Watt meter | 4 digit, digital Watt meter, resolution 0.1W | |
| Protection | With overload, short circuit, over temperature | |
| Instantaneous power failure protection and alarm device | ||
| Working Environment | Temperature | 0 - 40 deg.℃ |
| Humidity | 0 - 90% (Non condensation) | |
| Warranty | 18 months | |
Wiring and Testing a Single Cabinet Frequency Converter
Here is a video about the operating steps of the cabinet frequency converter. It gives a rundown of how to wire and test a single cabinet frequency converter using a multimeter.
Tips: Which voltage in 120V and 220V is better?
Everyone knows that the power grids in many countries are different. For example, the voltage in China is 220V 50Hz; the American standard is 120V 60Hz; Japan has the voltage of 100V 50/60Hz. The different electricity grid is mainly caused by historical reasons. With unchanged power capacity, the current of 110V voltage is two times of that of 220V, the sectional area of the conductor used is also bigger, the amount of consumed copper or aluminum is also more. A higher voltage leads to a lower line loss. A lower voltage results in a higher security, but greater line loss.
Input: 230VAC, 50Hz
Output: 115VAC (variable from 108VAC to 119 VAC), 400Hz 5Amp
It should be small in size. Desktop or chassis mount type.
480VAC 3ph Input
400Hz output. What do you recommend?
Output Power: 5kVA to 7kVA
Input Voltage: 160VAC, 660Hz
Output Voltage: >160VAC , 60Hz
Mounting type: Chassis mounted.
The further details can be discussed later.
Is this something your company could help us?
I would prefer to connect split-phase voltage. Please advise.
The input continues, keeping the machine running but it has no output. The machine has a light load when tripping the output.
I'm located in France, so I have a 230V 50Hz electrical network.
I'm looking for a solution to generate a voltage ranging from 100V to 230V and vary the frequency from 45Hz to 65Hz.
Do I necessarily need the 400Hz option to vary the frequency, or is this already possible with the 50/60Hz option? What would the variation range be?
I look forward to hearing from you.