7.5 hp VFD, Single Phase 120V Input, 1ph/3ph 220V Output

$453.86
7.5 hp variable frequency drive, single phase 120v input, single phase and three phase 220v output, running AC motor on single phase 110v/120v power supply, manufacturer direct sale.
SKU: GK3000-SP1S1-5d5
Free Shipping
Delivery date: 2-3 days

7.5 hp (5.5 kW) VFD, single phase input & output, convert single phase to three phase. 110v-120v input, 220v-240v output, 23 amps.

Specification:

Basics Model EM15-SP1S1-5d5
Capacity 7.5 hp (5.5 kW)
Shipping weight 5 kg
Dimension (W x H x D) 162*250*191 mm
I/O Feature Rated current 23 A
Input voltage 1 phase 120V AC ±15% (Set FE-00=0)
Input frequency 50Hz/60Hz
Output voltage 1 phase or 3 phase 220V AC ±15%
Output frequency 0~320Hz (SFC)
Control Feature Control mode V/F control; vector control
Communication Offer RS485 communication interface, support MODBUS-RTU communication protocol
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating IP 20
Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity smaller than 95%RH, non-condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Vibration Less than 5.9 m/s2 (0.6 g)
Cooling forced air cooling
Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

7.5hp VFD Single Phase 120v Input Details

Tips: VFD motor protection

  1. Do you need an overload to protect the motor? And if so do you put in on the PWM output side?
  2. How should I protect the variable frequency drive and Motor?

Variable frequency driveVFD itself has many protection functions by working on variation of controlling voltage & current through open/close IGBT and detecting CT/ VT. Depend on size of VFD we can see on panel input/ output, DC voltage; input/ output current or can measure by tool; The basic function is overload protection by both setting normal 110% and trip 150% mode.

The variable frequency drive (VFD) can make the thermal protection. However you can also use a digital relay to make it. In that case the relay will be connected downstream the VFD. Such arrangement is used when one drive will control several motors. The only tricky point is that the frequency tracking in the relay shall use the current, whereas the usual technology is to use the voltage. But there exist relays using the current measurements for frequency tracking.

For the second question you need an upstream protection, which can be ultra-rapid fuses or circuit breaker with protection relay. Eventually, a good solution for LV VFD would be to add a line-choke upstream the VFD, this will reduce the current transients seen by the input of the VFD. In MV VFD there are usually input transformers for the VFD which realizes this function.

Running a Three-phase Motor on a Single-phase Supply with a Frequency Converter

How to run a three phase or single phase motor with ATO VFD on 120V power supply. Take a 2 hp, single phase 120V input, single phase or three phase 220V output variable frequency drive as an example. It shows you how to wire, set parameters, commissioning VFD, run motors, etc.

VFD Programming for Stable Water Pressure in Water Supply System

A three-phase motor can be regulated using a single-phase 120V to three-phase 220V VFD, and control can be managed through terminals, as demonstrated in the following video.

Variable Frequency Drive Setting

In the video, it's demonstrated that ATO VFD offers multiple methods to adjust the frequency: Not only can you use the knob on the panel, but you can also utilize the buttons for adjustments.

Basic Troubleshooting Guide for VFD

In this video, ATO will show you the vfd basic troubleshooting guide.

How Many VFD Control Methods Do You Know?

Several methods to control the frequency of VFD:

1. Switch Button control: Use the switch signal to directly control the start and stop of the VFD (the VFD start frequency is fixed), and the multi-speed control method can be used to activate the speed of each section of the VFD.

2. Analog control: Use 5V or 0~20mA to control the frequency of the VFD, and at the same time can control the start and stop of the VFD in cooperation with the switch.

3. VFD potentiometer control: The VFD has its own potentiometer input terminal, and the VFD is directly controlled by the potentiometer.

4. Modbus-RTU control: Use RS485 interface to transmit data with Modbus-RTU protocol, which can monitor VFD, modify frequency, start and stop, etc.

5. DTU wireless remote control:Combine DTU terminal and VFD for wireless transmission. (DTU output analog quantity to control VFD frequency)

Running a Single or Three Phase Motor with a VFD on 120V Power

In this video, ATO will show you how to run a 120v variable frequency drive motor.

Running a Split-phase Motor with a 120V VFD (Terminal Control)

The ATO 120V inverter in the video can run single-phase motors/split-phase motors, three-phase motors. You can run the VFD in many ways.

Product reviews
Information about VFD
5
Wbender
Avatar
5/27/2021 2:33 AM
Is this VFD CSA approved? And what is the max amperage input, recommended breaker (2hp VFD 120V single phase input-220V 3 phase output)?
Was this review helpful? Yes No (0/0)
ATO Responded
1. CE approved only.
2. Input Current: 14A, breaker rating: not less than 20A.
How does a VFD connect to a compressor?
5
Daniel
Avatar
5/27/2022 1:14 AM
I bought this VFD, in order to run my 3 phase air compresor 220v/35Amps, now I am wondering if I need a swift output filter to connect the compressor, or that is optional?
Was this review helpful? Yes No (0/0)
ATO Responded
That is optional, you could add an output filter or not. The VFD can only carry the motor of the compressor and cannot be used as a power supply.
44/150 VDC input voltage, and output AC, 3-phase, 208V
5
Henry
Avatar
11/23/2023 11:48 PM
Can our SKU: GK3000-SP1S1-5d5 work based on 144/150 VDC input voltage, and output AC, 3-phase, 208V?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, the input voltage of the GK3000-SP1S1-5d5 VFD can only be a maximum of 138VAC and can Not input 144/150VDC.
I am looking for a bit of help
5
Benjamin
Avatar
1/8/2024 12:53 AM
I am looking for a bit of help in setting up one of your VFDs to run off of our PLC system. In particular, the 7.5hp VFD model is linked here. I have looked at the documentation here, but I want to be sure I do everything right. Can you provide step-by-step instructions on this? As well as how to wire it for this configuration.
Was this review helpful? Yes No (0/0)
ATO Responded
Please refer to the video on how to configure the VFD for control with a 0-10Vdc signal: https://www.youtube.com/watch?v=740KFfdA_M8&list=PLlo8RulDRnthB_yJeKHLcVVbUFz2r9ked&index=2
help, get ready and buy on amazon plz
5
Ever
Avatar
2/3/2026 10:15 AM
Good day, I need an answer as soon as possible, I have a 220v three-phase motor and I need to make it work with my 110v AC single-phase network.
The motor is 5hp 4kw, will there be any problem due to the strength of the motor with this VFD?
On Amazon I see a new one and a used one sold by yourselves, how recommended would the used one be?
I don't have much money.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, this voltage and power rating are suitable for your motor, but please check that your motor's rated current is less than the rated output current of this VFD (less than that indicates it's OK). Also, please note that before use, please confirm that parameter FE-00=0 (PV function is off).
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

7.5 hp (5.5 kW) VFD, single phase input & output, convert single phase to three phase. 110v-120v input, 220v-240v output, 23 amps.

Specification:

Basics Model EM15-SP1S1-5d5
Capacity 7.5 hp (5.5 kW)
Shipping weight 5 kg
Dimension (W x H x D) 162*250*191 mm
I/O Feature Rated current 23 A
Input voltage 1 phase 120V AC ±15% (Set FE-00=0)
Input frequency 50Hz/60Hz
Output voltage 1 phase or 3 phase 220V AC ±15%
Output frequency 0~320Hz (SFC)
Control Feature Control mode V/F control; vector control
Communication Offer RS485 communication interface, support MODBUS-RTU communication protocol
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating IP 20
Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity smaller than 95%RH, non-condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Vibration Less than 5.9 m/s2 (0.6 g)
Cooling forced air cooling
Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

7.5hp VFD Single Phase 120v Input Details

Tips: VFD motor protection

  1. Do you need an overload to protect the motor? And if so do you put in on the PWM output side?
  2. How should I protect the variable frequency drive and Motor?

Variable frequency driveVFD itself has many protection functions by working on variation of controlling voltage & current through open/close IGBT and detecting CT/ VT. Depend on size of VFD we can see on panel input/ output, DC voltage; input/ output current or can measure by tool; The basic function is overload protection by both setting normal 110% and trip 150% mode.

The variable frequency drive (VFD) can make the thermal protection. However you can also use a digital relay to make it. In that case the relay will be connected downstream the VFD. Such arrangement is used when one drive will control several motors. The only tricky point is that the frequency tracking in the relay shall use the current, whereas the usual technology is to use the voltage. But there exist relays using the current measurements for frequency tracking.

For the second question you need an upstream protection, which can be ultra-rapid fuses or circuit breaker with protection relay. Eventually, a good solution for LV VFD would be to add a line-choke upstream the VFD, this will reduce the current transients seen by the input of the VFD. In MV VFD there are usually input transformers for the VFD which realizes this function.

Product reviews
Information about VFD
5
Wbender
Avatar
5/27/2021 2:33 AM
Is this VFD CSA approved? And what is the max amperage input, recommended breaker (2hp VFD 120V single phase input-220V 3 phase output)?
Was this review helpful? Yes No (0/0)
ATO Responded
1. CE approved only.
2. Input Current: 14A, breaker rating: not less than 20A.
How does a VFD connect to a compressor?
5
Daniel
Avatar
5/27/2022 1:14 AM
I bought this VFD, in order to run my 3 phase air compresor 220v/35Amps, now I am wondering if I need a swift output filter to connect the compressor, or that is optional?
Was this review helpful? Yes No (0/0)
ATO Responded
That is optional, you could add an output filter or not. The VFD can only carry the motor of the compressor and cannot be used as a power supply.
44/150 VDC input voltage, and output AC, 3-phase, 208V
5
Henry
Avatar
11/23/2023 11:48 PM
Can our SKU: GK3000-SP1S1-5d5 work based on 144/150 VDC input voltage, and output AC, 3-phase, 208V?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, the input voltage of the GK3000-SP1S1-5d5 VFD can only be a maximum of 138VAC and can Not input 144/150VDC.
I am looking for a bit of help
5
Benjamin
Avatar
1/8/2024 12:53 AM
I am looking for a bit of help in setting up one of your VFDs to run off of our PLC system. In particular, the 7.5hp VFD model is linked here. I have looked at the documentation here, but I want to be sure I do everything right. Can you provide step-by-step instructions on this? As well as how to wire it for this configuration.
Was this review helpful? Yes No (0/0)
ATO Responded
Please refer to the video on how to configure the VFD for control with a 0-10Vdc signal: https://www.youtube.com/watch?v=740KFfdA_M8&list=PLlo8RulDRnthB_yJeKHLcVVbUFz2r9ked&index=2
help, get ready and buy on amazon plz
5
Ever
Avatar
2/3/2026 10:15 AM
Good day, I need an answer as soon as possible, I have a 220v three-phase motor and I need to make it work with my 110v AC single-phase network.
The motor is 5hp 4kw, will there be any problem due to the strength of the motor with this VFD?
On Amazon I see a new one and a used one sold by yourselves, how recommended would the used one be?
I don't have much money.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, this voltage and power rating are suitable for your motor, but please check that your motor's rated current is less than the rated output current of this VFD (less than that indicates it's OK). Also, please note that before use, please confirm that parameter FE-00=0 (PV function is off).
Only registered users can write reviews
Customers who bought this item also bought

10kVA Single Phase 240v 50Hz to 120v 60Hz Converter

HZ-50-1110
$4,676.59
10 kVA 1 phase solid state frequency converter, change 240V 50Hz to 120V 60Hz (vice versa), step up and step down frequency & voltage, supply high quality output electricity for test lab & production facilities.

2 hp (1.5kW) 220V Single Phase AC Induction Motor

ATO-SPIM-1500
$519.69
Cheap 2 hp single phase motor with 1.5kW, 1500rpm/3000rpm speed. It is an asynchronous motor. 200V/110V/230V/240V AC works at 50/60 Hz frequency. 2 hp 1 phase motor price is low. It has a start capacitor and run capacitor to provide zero starting torque during operation. The single phase induction motor is easy to repair and maintain, used for drills, air conditioners, compressors, pumps, cranes, garage door opening and closing systems.