45kVA 3-Phase 480v 60Hz/400v 50Hz Frequency Converter

$13,670.41
Affordable 45 kVA static frequency converter, built-in step-down/step-up transformer, convert 3 phase 480V 60Hz (e.g. US) to 400V 50Hz (e.g. Israel), 380V 50Hz (e.g. Germany), also change 3-phase 220V 60Hz to 380V/400V 50Hz in one step.
SKU: HZ-50-3345
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-16 days

45 kVA three phase static frequency converter, compatible with 3 phase 208v/ 220v/ 380v/ 415v/ 460v/ 480v 50Hz/60Hz power system, output pure sine wave for testing and industrial equipment.

Specification:

ModelHZ-50-3345
Capacity45 kVA
Dimension900*800*1200 mm
Weight400 kg
InputVoltage3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V ±10% (option *)
3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% (option *)
3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ± 10% (option *)
Frequency50 Hz, 60 Hz
OutputVoltage, current110V Setting (Low grade): 0-150V (phase voltage), 0-260V (line voltage) 125A
220V Setting (High grade): 0-300V (phase voltage), 0-520V (line voltage) 62.5A
Load stabilization Rate≤±1%
Frequency50Hz, 60Hz up to 400Hz adjustable
Note:
-When the output is 400Hz, the load capacity can only reach 50% of the rated capacity.
-When the output is ≤120Hz, the load capacity can reach 100% of the rated value.
-You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option.
Frequency Stability≤±0.01%
Harmonic DistortionPure Sine Wave ≤2%
Frequency meter4 digit, digital frequency meter, resolution 0.1Hz/Step
Voltmeter4 digit, digital voltage meter, resolution 0.1V
Ammeter4 digit, digital ammeter, resolution 0.1A
Watt meter4 digit, digital Watt meter, resolution 0.1W
ProtectionWith overload, short circuit, over temperature
Instantaneous power failure protection and alarm device
Working EnvironmentTemperature0 - 40 deg.℃
Humidity0 - 90% (Non condensation)
Warranty18 months


Tips: Can a 50Hz motor run on 60Hz power source?

The frequency is increased from 50 Hz to 60 Hz and the motor will not work properly. The main effects to the motor are:
First, the current and output torque are reduced. The motor is an inductive load, the frequency increases, the impedance of the motor increases, and the current decreases. The output torque is also reduced.
Second, the speed increases. The synchronous speed of the motor is proportional to the frequency of the power supply. Taking a two-pole motor as an example, the synchronous speed is 3000 rpm at 50Hz and the synchronous speed is 3600 rpm at 60Hz.
Third, the iron loss increases. The iron loss is mainly eddy current. The eddy current is proportional to the frequency, and the eddy current increases to increase the temperature rise of the motor.

How to Test a 9V Transformer Power Supply in a Frequency Converter?

This video shows you how to use a multimeter to test the IGBT in a frequency converter.

How to Use a Multimeter to Test the IGBT in a Frequency Converter?

This video shows you how to use a multimeter to test the IGBT in a frequency converter.

How to Check the Fuse of a Frequency Converter?

In this video, the steps on how to check the fuse of a frequency converter using a multimeter are shown.

Product reviews
Frequency converter recommended by ATO
5
Rmills
Avatar
8/1/2021 8:21 PM
I’m trying to locate a transformer / converter that will allow US made equipment to operate in Spain. So it must meet EU specifications. Output is 200A of 460VAC – 3 PH, 60Hz.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, based on your specs, recommended frequency converter model: HZ-50-33200, 200kVA power capacity, input: 3ph, Wye (L1,L2,L3 + N,G), 380V (+/- 10%), 50/ 60Hz and output: 3ph, Wye/Delta (L1,L2,L3 + N,G), adjustable (0-520V), adjustable (40-120Hz), 277A.
Use of frequency converter
5
Sandy
Avatar
8/26/2021 12:18 AM
Do you see any issues using your frequency converter on an inverter system? Do you have data on the power efficiency of the system?
Was this review helpful? Yes No (0/0)
ATO Responded
1. No, no issues with using the frequency converter on an inverter system.
2. The power efficiency of the converter is varied with loading, not fixed. But generally, its approx 80%.
Protection of frequency converter
5
Uraina
Avatar
9/16/2021 7:02 PM
I see that your converters are short circuit, and overload protected. Our country it is mandatory to also have residual current control to break the power supply. (30 mA Phase/N to ground).
Are the N on the output internally connected to ground, or is it insulated/floating? Should it be connected to the ground externally?
I have a residual current breaker upstream of the converter, but do I have to install a residual current breaker downstream from the converter as well?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The N on the output does not internally connect to ground, it just comes from the internal transformer of the converter, and it is semi-floating.
So normally the output N and the external ground are not connected together, but if you want to connect the external ground G to the output N at your load side, then it's okay, and no problem.
2. If you have a residual current breaker upstream of the converter, then there is no need to install a residual current breaker downstream the converter.
I want to buy a frequency converter
5
Rael
Avatar
9/28/2021 8:02 PM
I have a piece of kit from America (a pelaton treadmill). The treadmill requires 120v, 60hz, 12amp. We are based in the UK and run on 230v 50Hz. Could you advise of a piece of equipment that would be suitable for this please and include a price including shipping to the UK.
Was this review helpful? Yes No (0/0)
ATO Responded
Based on your specs, recommended frequency converter model: HZ-50-1110, 10kVA power capacity, input: 1ph, 230V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable ( 0-150V), adjustable (40-120Hz), 83.2A.
I want a frequency converter that can convert voltage and frequency
5
Leonk
Avatar
10/13/2021 8:17 PM
I want a frequency converter that can convert 60Hz 110V to 50Hz 220V. The load is 3kW (heater   stepper motor). What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, recommended frequency converter model: HZ-50-1105, 5kVA power capacity, input: 1ph, 110V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable (0-300V ), adjusted (40-120Hz), 20.8A.
ATO's advice on buying frequency converter
5
Ortiz
Avatar
12/13/2021 7:06 PM
1PCS frequency converter 220-230 Volt, 50Hz, to 110-120 Volt, 60Hz, 1KVA step down-step up frequency&voltage converter, brand: go Hz. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Based on your choice, recommended frequency converter model: HZ-60-1101, 1kVA power capacity, input: 1ph, 220V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable ( 0-150V), adjustable (40-120Hz), 8.4A.
I am interested in your frequency converter.
5
Obed
Avatar
1/17/2022 5:50 PM
I am interested in the frequency converter to supply historic US Jukeboxes. Could you inform me about the acoustic noise of the built in cooler?
Was this review helpful? Yes No (0/0)
ATO Responded
It is silent, max noise generated by fan is approx 40-50 db. Also, you can place the converter 30-40m away or so and use extended wires, then no noise at all.
How to solve the problem of 60Hz frequency converter?
5
oz
Avatar
4/6/2023 9:19 PM
Good Morning,
We are having issues with our frequency converter, only two of the three phases is working properly. Please see attached for the data plate as well as a brief video of the converter running.
We’d like to have this unit repaired, if you could please provide information or a quote for having a technician repair, I’d like to get that done as soon as possible.
We are located at the Naval Information Warfare Center in San Diego, CA.
Please let me know if you need any other information before coordinating, thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
1. The video you feedback is very blurry, and we can not see the video information clearly. Please describe the specific problem of the frequency converter in words, and tell us which phase of the three-phase output U, V, W is faulty?
2. After confirming which phase output has the problem, you can follow the troubleshooting document attached. Please measure the fuse, IGBT module, driver board, and feedback the measurement results to us.
You can also refer to our video see on: https://www.youtube.com/watch?v=X-BS9sPuSBs
3. If it is the problem of the output frequency of the converter, please check the document according to the capacitance in the attachment. Please measure the three-phase CBB65 capacitance, and feedback the result to us.
I needed technical support for the converter
5
jennie
Avatar
8/28/2023 3:36 AM
We are using it at a repair station for aircraft parts. We have been running motor pumps with no problems so far until the past week when the safety on the power supply started to trip when it reached 43 amps but before we were able to use it up to 50 amps, I needed technical support, please. This is vital equipment for the continuance of our business, thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
After the converter fails, can it still be used after resetting?  
Please send us a picture of the converter nameplate label and a video for further confirmation.
You can send us the large video file via wetransfer.com.
Please open the converter side covers and power on the converter, then take a video showing us the internal main circuit boards, especially the ones with red LED indicators and beeping sound, and show us the converter display as well while the converter is running.
Why does the converter not hold more than 43 amps?
5
doro
Avatar
8/29/2023 12:35 AM
The converter can be used after resetting.
The problem is why it does not hold more than 43 amps.
It used to go all the way up to 50 amps.
Was this review helpful? Yes No (0/0)
ATO Responded
If the machine can start normally after reset, it means that no components are damaged.
We think it may be that the service life is relatively long, and the driving ability of electronic components has declined.
We still need your feedback on a video for further confirmation. Information that the video should include: open converter side covers and power on the converter.
When the current reaches 43A and the fault occurs, take a video showing us the internal main circuit boards, especially the ones with red LED indicators and beeping sound, and show us the converter display as well while the converter is running.
Finally, you need to return to the operation panel, switch the U/V/W three-phase switch manually, and check the U-V-W three-phase display. We need your information to proceed to the next step.
Why is this frustrating stuff happening?
5
alfor
Avatar
11/7/2023 11:22 PM
We have successfully installed you 45kva unit we purchased in a climate controlled room.  The unit operates and powers all of the house’s load, but randomly (sometimes at night, sometimes in the day) trips off and requires us to reset the panel on the front.
Why is this frustrating stuff happening?
Was this review helpful? Yes No (0/0)
ATO Responded
This situation should be caused by fluctuations in the electrical load of the entire room, resulting in overload. Please stop running the converter now.
You can refer to the attached document to rotate the potentiometer counterclockwise for 8 turns, appropriately increase the current protection threshold, and test again.
If you still have problems, please send us a picture of the converter's nameplate label for further confirmation. And list the power, voltage, current and other information of all loads in the entire room.
I have a technical question regarding the Frequency Converter
5
Blake
Avatar
2/5/2024 7:56 PM
I have a technical question regarding the 400Hz Frequency Converter. For longevity purposes, should the unit be turned off when not in use or left on?
Was this review helpful? Yes No (0/0)
ATO Responded
In order to extend the service life, the Converte should be shut down when Not in use and should be cleaned and maintained regularly. You can refer to the user manual instructions in the attachment.
I need your support
4
Biliske
Avatar
1/21/2025 12:13 AM
Hello, I need your support. I'm using your product HZ-50-3345. It's Hz is fixed at 40Hz, and I need to change it to 0Hz, but I don't know how. Please let me know how to change it.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, the minimum frequency supported by our converter is 40Hz, and it can Not output 0Hz.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

45 kVA three phase static frequency converter, compatible with 3 phase 208v/ 220v/ 380v/ 415v/ 460v/ 480v 50Hz/60Hz power system, output pure sine wave for testing and industrial equipment.

Specification:

ModelHZ-50-3345
Capacity45 kVA
Dimension900*800*1200 mm
Weight400 kg
InputVoltage3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V ±10% (option *)
3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% (option *)
3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ± 10% (option *)
Frequency50 Hz, 60 Hz
OutputVoltage, current110V Setting (Low grade): 0-150V (phase voltage), 0-260V (line voltage) 125A
220V Setting (High grade): 0-300V (phase voltage), 0-520V (line voltage) 62.5A
Load stabilization Rate≤±1%
Frequency50Hz, 60Hz up to 400Hz adjustable
Note:
-When the output is 400Hz, the load capacity can only reach 50% of the rated capacity.
-When the output is ≤120Hz, the load capacity can reach 100% of the rated value.
-You can just adjust converter output frequency in the range (40-400Hz) for 400Hz option.
Frequency Stability≤±0.01%
Harmonic DistortionPure Sine Wave ≤2%
Frequency meter4 digit, digital frequency meter, resolution 0.1Hz/Step
Voltmeter4 digit, digital voltage meter, resolution 0.1V
Ammeter4 digit, digital ammeter, resolution 0.1A
Watt meter4 digit, digital Watt meter, resolution 0.1W
ProtectionWith overload, short circuit, over temperature
Instantaneous power failure protection and alarm device
Working EnvironmentTemperature0 - 40 deg.℃
Humidity0 - 90% (Non condensation)
Warranty18 months


Tips: Can a 50Hz motor run on 60Hz power source?

The frequency is increased from 50 Hz to 60 Hz and the motor will not work properly. The main effects to the motor are:
First, the current and output torque are reduced. The motor is an inductive load, the frequency increases, the impedance of the motor increases, and the current decreases. The output torque is also reduced.
Second, the speed increases. The synchronous speed of the motor is proportional to the frequency of the power supply. Taking a two-pole motor as an example, the synchronous speed is 3000 rpm at 50Hz and the synchronous speed is 3600 rpm at 60Hz.
Third, the iron loss increases. The iron loss is mainly eddy current. The eddy current is proportional to the frequency, and the eddy current increases to increase the temperature rise of the motor.

Product reviews
Frequency converter recommended by ATO
5
Rmills
Avatar
8/1/2021 8:21 PM
I’m trying to locate a transformer / converter that will allow US made equipment to operate in Spain. So it must meet EU specifications. Output is 200A of 460VAC – 3 PH, 60Hz.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, based on your specs, recommended frequency converter model: HZ-50-33200, 200kVA power capacity, input: 3ph, Wye (L1,L2,L3 + N,G), 380V (+/- 10%), 50/ 60Hz and output: 3ph, Wye/Delta (L1,L2,L3 + N,G), adjustable (0-520V), adjustable (40-120Hz), 277A.
Use of frequency converter
5
Sandy
Avatar
8/26/2021 12:18 AM
Do you see any issues using your frequency converter on an inverter system? Do you have data on the power efficiency of the system?
Was this review helpful? Yes No (0/0)
ATO Responded
1. No, no issues with using the frequency converter on an inverter system.
2. The power efficiency of the converter is varied with loading, not fixed. But generally, its approx 80%.
Protection of frequency converter
5
Uraina
Avatar
9/16/2021 7:02 PM
I see that your converters are short circuit, and overload protected. Our country it is mandatory to also have residual current control to break the power supply. (30 mA Phase/N to ground).
Are the N on the output internally connected to ground, or is it insulated/floating? Should it be connected to the ground externally?
I have a residual current breaker upstream of the converter, but do I have to install a residual current breaker downstream from the converter as well?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The N on the output does not internally connect to ground, it just comes from the internal transformer of the converter, and it is semi-floating.
So normally the output N and the external ground are not connected together, but if you want to connect the external ground G to the output N at your load side, then it's okay, and no problem.
2. If you have a residual current breaker upstream of the converter, then there is no need to install a residual current breaker downstream the converter.
I want to buy a frequency converter
5
Rael
Avatar
9/28/2021 8:02 PM
I have a piece of kit from America (a pelaton treadmill). The treadmill requires 120v, 60hz, 12amp. We are based in the UK and run on 230v 50Hz. Could you advise of a piece of equipment that would be suitable for this please and include a price including shipping to the UK.
Was this review helpful? Yes No (0/0)
ATO Responded
Based on your specs, recommended frequency converter model: HZ-50-1110, 10kVA power capacity, input: 1ph, 230V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable ( 0-150V), adjustable (40-120Hz), 83.2A.
I want a frequency converter that can convert voltage and frequency
5
Leonk
Avatar
10/13/2021 8:17 PM
I want a frequency converter that can convert 60Hz 110V to 50Hz 220V. The load is 3kW (heater   stepper motor). What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, recommended frequency converter model: HZ-50-1105, 5kVA power capacity, input: 1ph, 110V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable (0-300V ), adjusted (40-120Hz), 20.8A.
ATO's advice on buying frequency converter
5
Ortiz
Avatar
12/13/2021 7:06 PM
1PCS frequency converter 220-230 Volt, 50Hz, to 110-120 Volt, 60Hz, 1KVA step down-step up frequency&voltage converter, brand: go Hz. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Based on your choice, recommended frequency converter model: HZ-60-1101, 1kVA power capacity, input: 1ph, 220V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable ( 0-150V), adjustable (40-120Hz), 8.4A.
I am interested in your frequency converter.
5
Obed
Avatar
1/17/2022 5:50 PM
I am interested in the frequency converter to supply historic US Jukeboxes. Could you inform me about the acoustic noise of the built in cooler?
Was this review helpful? Yes No (0/0)
ATO Responded
It is silent, max noise generated by fan is approx 40-50 db. Also, you can place the converter 30-40m away or so and use extended wires, then no noise at all.
How to solve the problem of 60Hz frequency converter?
5
oz
Avatar
4/6/2023 9:19 PM
Good Morning,
We are having issues with our frequency converter, only two of the three phases is working properly. Please see attached for the data plate as well as a brief video of the converter running.
We’d like to have this unit repaired, if you could please provide information or a quote for having a technician repair, I’d like to get that done as soon as possible.
We are located at the Naval Information Warfare Center in San Diego, CA.
Please let me know if you need any other information before coordinating, thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
1. The video you feedback is very blurry, and we can not see the video information clearly. Please describe the specific problem of the frequency converter in words, and tell us which phase of the three-phase output U, V, W is faulty?
2. After confirming which phase output has the problem, you can follow the troubleshooting document attached. Please measure the fuse, IGBT module, driver board, and feedback the measurement results to us.
You can also refer to our video see on: https://www.youtube.com/watch?v=X-BS9sPuSBs
3. If it is the problem of the output frequency of the converter, please check the document according to the capacitance in the attachment. Please measure the three-phase CBB65 capacitance, and feedback the result to us.
I needed technical support for the converter
5
jennie
Avatar
8/28/2023 3:36 AM
We are using it at a repair station for aircraft parts. We have been running motor pumps with no problems so far until the past week when the safety on the power supply started to trip when it reached 43 amps but before we were able to use it up to 50 amps, I needed technical support, please. This is vital equipment for the continuance of our business, thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
After the converter fails, can it still be used after resetting?  
Please send us a picture of the converter nameplate label and a video for further confirmation.
You can send us the large video file via wetransfer.com.
Please open the converter side covers and power on the converter, then take a video showing us the internal main circuit boards, especially the ones with red LED indicators and beeping sound, and show us the converter display as well while the converter is running.
Why does the converter not hold more than 43 amps?
5
doro
Avatar
8/29/2023 12:35 AM
The converter can be used after resetting.
The problem is why it does not hold more than 43 amps.
It used to go all the way up to 50 amps.
Was this review helpful? Yes No (0/0)
ATO Responded
If the machine can start normally after reset, it means that no components are damaged.
We think it may be that the service life is relatively long, and the driving ability of electronic components has declined.
We still need your feedback on a video for further confirmation. Information that the video should include: open converter side covers and power on the converter.
When the current reaches 43A and the fault occurs, take a video showing us the internal main circuit boards, especially the ones with red LED indicators and beeping sound, and show us the converter display as well while the converter is running.
Finally, you need to return to the operation panel, switch the U/V/W three-phase switch manually, and check the U-V-W three-phase display. We need your information to proceed to the next step.
Why is this frustrating stuff happening?
5
alfor
Avatar
11/7/2023 11:22 PM
We have successfully installed you 45kva unit we purchased in a climate controlled room.  The unit operates and powers all of the house’s load, but randomly (sometimes at night, sometimes in the day) trips off and requires us to reset the panel on the front.
Why is this frustrating stuff happening?
Was this review helpful? Yes No (0/0)
ATO Responded
This situation should be caused by fluctuations in the electrical load of the entire room, resulting in overload. Please stop running the converter now.
You can refer to the attached document to rotate the potentiometer counterclockwise for 8 turns, appropriately increase the current protection threshold, and test again.
If you still have problems, please send us a picture of the converter's nameplate label for further confirmation. And list the power, voltage, current and other information of all loads in the entire room.
I have a technical question regarding the Frequency Converter
5
Blake
Avatar
2/5/2024 7:56 PM
I have a technical question regarding the 400Hz Frequency Converter. For longevity purposes, should the unit be turned off when not in use or left on?
Was this review helpful? Yes No (0/0)
ATO Responded
In order to extend the service life, the Converte should be shut down when Not in use and should be cleaned and maintained regularly. You can refer to the user manual instructions in the attachment.
I need your support
4
Biliske
Avatar
1/21/2025 12:13 AM
Hello, I need your support. I'm using your product HZ-50-3345. It's Hz is fixed at 40Hz, and I need to change it to 0Hz, but I don't know how. Please let me know how to change it.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, the minimum frequency supported by our converter is 40Hz, and it can Not output 0Hz.
Only registered users can write reviews
Customers who bought this item also bought

10kVA 3-Phase 480v 60Hz/380v 50Hz Frequency Converter

HZ-50-3310
$5,990.75
High quality three phase 10 kVA frequency converter (AC power supply), convert 480V/460V 60Hz to 380V/400V 50Hz by inner step-up & step-down transformer, adjustable output frequency & voltage suitable for industrial equipments.

30kVA 3-Phase 220v 60Hz/400v 50Hz Frequency Converter

HZ-50-3330
$11,833.47
30 kVA three phase 220V 60Hz to 380V/400V 50Hz frequency converter, change 480V 460V to 380 Volt in one step, convert voltage and Hertz by bulit-in step up & step down transformer, make different devices work well on different power systems.

50VA Toroidal Transformer, 120V to 24-0-24V/30-0-30V

ATO-T-C50VA
$89.35
50VA toroidal transformer steps down a primary voltage of 120V to selectable secondary voltages of 24-0-24V (2x24V) / 30-0-30V (2x30V) or other voltages. This single-phase transformer using high-quality copper wire, ensures superior power handling with minimal losses. Its customizability allows for tailored electrical solutions, fitting specific power demands. The toroidal design offers advantages like reduced magnetic interference and compactness, making it a preferred choice for power-sensitive applications.

10kVA Single Phase 240v 50Hz to 120v 60Hz Converter

HZ-50-1110
$4,676.59
10 kVA 1 phase solid state frequency converter, change 240V 50Hz to 120V 60Hz (vice versa), step up and step down frequency & voltage, supply high quality output electricity for test lab & production facilities.