15kVA 3-Phase 400v 50Hz/480v 60Hz Frequency Converter

$7,189.59
15 kVA three phase 380V/400V/415V to 460V/480V frequency converter, easy converting 208V - 240V to 380V in one step, output single phase or three phase with pure sine wave, supply the electronic instrument with high quality electricity.
SKU: HZ-50-3315
*
*
*
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 10-16 days

Reasonable price 15 kVA static frequency converter, 50Hz/60Hz 400Hz conversion, three phase 220V, 240V, 380V, 400V, 415V, 460V, 480V, make different appliances work well on different power system.

Specification:

ModelHZ-50-3315
Capacity15 kVA
Dimension770 (D)*580 (W)*1140 (H) mm
Weight190 kg
InputVoltage3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V ±10% (option *)
3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% (option *)
3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ± 10% (option *)
Frequency50 Hz, 60 Hz
OutputVoltage, current110V Setting (Low grade): 0-150V (phase voltage), 0-260V (line voltage) 41.6A
220V Setting (High grade): 0-300V (phase voltage), 0-520V (line voltage) 20.8A
Load stabilization Rate≤±1%
Frequency50Hz, 60Hz up to 400Hz adjustable
Note:
When the output is 400Hz, the load capacity can only reach 50% of the rated capacity;
When the output is ≤120Hz, the load capacity can reach 100% of the rated value.
Frequency Stability≤±0.01%
Harmonic DistortionPure Sine Wave ≤2%
Frequency meter4 digit, digital frequency meter, resolution 0.1Hz/Step
Voltmeter4 digit, digital voltage meter, resolution 0.1V
Ammeter4 digit, digital ammeter, resolution 0.1A
Watt meter4 digit, digital Watt meter, resolution 0.1W
ProtectionWith overload, short circuit, over temperature
Instantaneous power failure protection and alarm device
Working EnvironmentTemperature0 - 40 deg.℃
Humidity0 - 90% (Non condensation)
Warranty18 months

Automatic time delay start circuit diagram

Frequency converter automatic time delay start circuit diagram

Tips: Both 50Hz and 60Hz have their advantages and disadvantages

For 60 Hertz, the transformer can be smaller and cheaper than a 50 Hz transformer. Although the difference is small, it can be accumulated in a system with many transformers. Using 60Hz can reduce the flicker of the bulb, but now this is really not a factor.
For 50 Hertz, power transmission over long lines is more convenient than 60 Hz. At lower frequency, the distributed capacitance and inductance of the line are also less affected. While 50Hz transformers require more copper and iron, 60Hz transformers require more expensive boards to prevent eddy current losses.



How to Test a 9V Transformer Power Supply in a Frequency Converter?

This video shows you how to use a multimeter to test the IGBT in a frequency converter.

How to Use a Multimeter to Test the IGBT in a Frequency Converter?

This video shows you how to use a multimeter to test the IGBT in a frequency converter.

How to Check the Fuse of a Frequency Converter?

In this video, the steps on how to check the fuse of a frequency converter using a multimeter are shown.

Product reviews
Changed frequency converter order
5
Hopkins
Avatar
4/11/2021 11:44 PM
Hello, I need electric change from 240V 3ph 60Hz to 400V 3ph 50Hz. Machine power is 5 kw.
Was this review helpful? Yes No (0/0)
ATO Responded
Recommended frequency converter model: HZ-50-3310, 10kVA power capacity, input: 3ph, Wye (L1,L2,L3 + N,G), 220V (+/- 10%), 50/60Hz and output: 3ph, Wye /Delta (L1,L2,L3 + N,G), adjustable (0-520V), adjustable (40-120Hz), 13.8A.
Related issues of 15kVA three-phase inverter
5
Venise
Avatar
4/26/2021 8:30 PM
What is the tolerance for input & output of 15kVA 3-phase frequency converter?
Was this review helpful? Yes No (0/0)
ATO Responded
Supply: Converter input voltage has a tolerance of (+/- 10%), and input frequency is 50/60Hz (accepts both).
Load: Converter output voltage is adjustable (0-520V)/(0-260V), and output frequency is adjustable too (40-120Hz).
15kVA frequency converter specifications
5
Sfellows
Avatar
8/5/2021 12:46 AM
We have a 3phase 208v outlet with a 50A breaker. We would like to order a unit that can utilize most of the power available. Would that be the 15KVA converter model HZ-50-3315?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, that is right, but please note what follows:
The converter specs, will be: Model: HZ-50-3315, 15kVA power capacity, input: 3ph, Wye (L1,L2,L3 + N,G), 208V (+/- 10%), 50/60Hz and output: 3ph, Wye/Delta (L1,L2,L3 + N,G), adjustable (0-520V)/(0-260V), adjustable (40-120Hz), 20.8A/41.6A.
I want a frequency converter for a 75kVA transformer
5
Gcooke
Avatar
10/7/2021 8:00 PM
I'd like to get a frequency converter to convert from 60Hz to 50 Hz for 75kVA transformer at 420 Volts. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Recommended frequency converter model: HZ-50-3375, 75kVA power capacity, input: 3ph, Wye (L1, L2, L3 + N, G), 420V (+/- 10%), 50/60Hz and output: 3ph, Wye /Delta (L1, L2, L3 + N, G), adjustable (0-520V)/, adjustable (40-120Hz), 104.2A.
Frequency converter for motors
5
Periloo
Avatar
10/17/2021 8:17 PM
We have three pieces of equipment to wire. All are 220V single phase 50Hz one piece is 3.0kW, the second is 1.0kW and the third is 290 watts. All are motors. Available input supply is 208V 60Hz. What is the recommended frequency converter?
Was this review helpful? Yes No (0/0)
ATO Responded
Based on your specs, recommended frequency converter model: HZ-50-1130, 30kVA power capacity, input: 1ph, 208V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable ( 0-300V), adjustable (40-120Hz), 125A.
Do you have a frequency converter that meets our requirements?
5
Joebwhn
Avatar
12/7/2021 7:23 PM
I'm looking to install a machine intended for 208/3/60 operation in Germany. Do you have a voltage/frequency converter that will change the 400V/50hz power in Germany to 208V/60hz power? The maximum current draw is 30amps at 208V, and it's a 3 phase heater with no internal motor?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, based on your specs, recommended frequency converter model: HZ-50-3315, 15kVA power capacity, input: 3ph, Wye (L1, L2, L3 + N, G), 400V (+/- 10%), 50/ 60Hz and output: 3ph, Wye/Delta (L1, L2, L3 + N, G), adjustable (0-260V), adjustable (40-120Hz), 41.6A.
Two questions about frequency converter
5
Balush
Avatar
1/4/2022 6:07 PM
Is your frequency converter CE certified?
What are the quality documents furnished with product supply?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our frequency converter is CE certified,.
For quality document: We provide factory calibration certificate which is done during converter testing stages.
When the power goes the conversation has to be manually reset and started. Is there any way this can be down automatically?
5
Joey
Avatar
9/9/2022 3:28 AM
The communication must be manually restarted when the power goes out. Is there a way to have this shut off automatically?

The converter is located in a retail building, and after a few incidents, the building manager went to check on it and discovered that it was beeping and showing just zeroes. Then, until it was reset and turned on by pressing the red and green buttons, all of the appliances were turned off.

Is there a method to prevent it? I believe it's due to the power loss, but are there any other possible causes? Or did it restart on its own?
Was this review helpful? Yes No (0/0)
ATO Responded
In this situation, you want the converter to have the capability of starting up automatically following a power outage, correct?
You can change the circuit of the start contactor coil KM1 by adding a delay relay KT and setting the delay period to 15 seconds, as shown in the automatic time delay start circuit diagram stated on the detail page above.
Please send me test report for the frequency converter.
5
hymen
Avatar
5/10/2023 1:33 AM
I will have to work on getting that voltage level for you. Just so I understand this, if the phase voltage is set to 120V, then the difference in the measured output line voltage would be the error between the actual output voltage and the display voltage?
Also, would you be able to send me an example test report for the Hz-50-3375 frequency converter as reference, similar to the one you sent me for the 3315 model?
Was this review helpful? Yes No (0/0)
ATO Responded
Please check the attached picture, there is a DIP switch on the machine to select phase voltage/line voltage mode, line voltage=phase voltage*1.732. If you choose phase voltage, the machine will display phase voltage. If you choose line voltage, the machine will display line voltage.
So, if the phase voltage is set to 120V, then the output phase voltage (U-N, V-N, W-N) should be close to 120V, and the line voltage (U-V, V-W, U-W) is equivalent to 207.8V AC. You need to measure the voltage at the output terminal and compare it with the voltage displayed on the display panel of the machine to check how much V is the error between them.
The test report is the same, you can refer to the 15KVA report.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Reasonable price 15 kVA static frequency converter, 50Hz/60Hz 400Hz conversion, three phase 220V, 240V, 380V, 400V, 415V, 460V, 480V, make different appliances work well on different power system.

Specification:

ModelHZ-50-3315
Capacity15 kVA
Dimension770 (D)*580 (W)*1140 (H) mm
Weight190 kg
InputVoltage3 Phase 4 Wire: Wye Type 190/110, 200/115, 208/120, 220/128, 230/132, 240/139V ±10% (option *)
3 Phase 4 Wire: Wye Type 380/220, 400/230, 415/240, 440/254, 460/265, 480/277V ± 10% (option *)
3 Phase 4 Wire: Della Type 220, 230, 240, 380, 400, 415, 440V ± 10% (option *)
Frequency50 Hz, 60 Hz
OutputVoltage, current110V Setting (Low grade): 0-150V (phase voltage), 0-260V (line voltage) 41.6A
220V Setting (High grade): 0-300V (phase voltage), 0-520V (line voltage) 20.8A
Load stabilization Rate≤±1%
Frequency50Hz, 60Hz up to 400Hz adjustable
Note:
When the output is 400Hz, the load capacity can only reach 50% of the rated capacity;
When the output is ≤120Hz, the load capacity can reach 100% of the rated value.
Frequency Stability≤±0.01%
Harmonic DistortionPure Sine Wave ≤2%
Frequency meter4 digit, digital frequency meter, resolution 0.1Hz/Step
Voltmeter4 digit, digital voltage meter, resolution 0.1V
Ammeter4 digit, digital ammeter, resolution 0.1A
Watt meter4 digit, digital Watt meter, resolution 0.1W
ProtectionWith overload, short circuit, over temperature
Instantaneous power failure protection and alarm device
Working EnvironmentTemperature0 - 40 deg.℃
Humidity0 - 90% (Non condensation)
Warranty18 months

Automatic time delay start circuit diagram

Frequency converter automatic time delay start circuit diagram

Tips: Both 50Hz and 60Hz have their advantages and disadvantages

For 60 Hertz, the transformer can be smaller and cheaper than a 50 Hz transformer. Although the difference is small, it can be accumulated in a system with many transformers. Using 60Hz can reduce the flicker of the bulb, but now this is really not a factor.
For 50 Hertz, power transmission over long lines is more convenient than 60 Hz. At lower frequency, the distributed capacitance and inductance of the line are also less affected. While 50Hz transformers require more copper and iron, 60Hz transformers require more expensive boards to prevent eddy current losses.



Product reviews
Changed frequency converter order
5
Hopkins
Avatar
4/11/2021 11:44 PM
Hello, I need electric change from 240V 3ph 60Hz to 400V 3ph 50Hz. Machine power is 5 kw.
Was this review helpful? Yes No (0/0)
ATO Responded
Recommended frequency converter model: HZ-50-3310, 10kVA power capacity, input: 3ph, Wye (L1,L2,L3 + N,G), 220V (+/- 10%), 50/60Hz and output: 3ph, Wye /Delta (L1,L2,L3 + N,G), adjustable (0-520V), adjustable (40-120Hz), 13.8A.
Related issues of 15kVA three-phase inverter
5
Venise
Avatar
4/26/2021 8:30 PM
What is the tolerance for input & output of 15kVA 3-phase frequency converter?
Was this review helpful? Yes No (0/0)
ATO Responded
Supply: Converter input voltage has a tolerance of (+/- 10%), and input frequency is 50/60Hz (accepts both).
Load: Converter output voltage is adjustable (0-520V)/(0-260V), and output frequency is adjustable too (40-120Hz).
15kVA frequency converter specifications
5
Sfellows
Avatar
8/5/2021 12:46 AM
We have a 3phase 208v outlet with a 50A breaker. We would like to order a unit that can utilize most of the power available. Would that be the 15KVA converter model HZ-50-3315?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, that is right, but please note what follows:
The converter specs, will be: Model: HZ-50-3315, 15kVA power capacity, input: 3ph, Wye (L1,L2,L3 + N,G), 208V (+/- 10%), 50/60Hz and output: 3ph, Wye/Delta (L1,L2,L3 + N,G), adjustable (0-520V)/(0-260V), adjustable (40-120Hz), 20.8A/41.6A.
I want a frequency converter for a 75kVA transformer
5
Gcooke
Avatar
10/7/2021 8:00 PM
I'd like to get a frequency converter to convert from 60Hz to 50 Hz for 75kVA transformer at 420 Volts. What do you recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Recommended frequency converter model: HZ-50-3375, 75kVA power capacity, input: 3ph, Wye (L1, L2, L3 + N, G), 420V (+/- 10%), 50/60Hz and output: 3ph, Wye /Delta (L1, L2, L3 + N, G), adjustable (0-520V)/, adjustable (40-120Hz), 104.2A.
Frequency converter for motors
5
Periloo
Avatar
10/17/2021 8:17 PM
We have three pieces of equipment to wire. All are 220V single phase 50Hz one piece is 3.0kW, the second is 1.0kW and the third is 290 watts. All are motors. Available input supply is 208V 60Hz. What is the recommended frequency converter?
Was this review helpful? Yes No (0/0)
ATO Responded
Based on your specs, recommended frequency converter model: HZ-50-1130, 30kVA power capacity, input: 1ph, 208V (+/- 10%), 50/60Hz and output: 1ph (L, N, G), adjustable ( 0-300V), adjustable (40-120Hz), 125A.
Do you have a frequency converter that meets our requirements?
5
Joebwhn
Avatar
12/7/2021 7:23 PM
I'm looking to install a machine intended for 208/3/60 operation in Germany. Do you have a voltage/frequency converter that will change the 400V/50hz power in Germany to 208V/60hz power? The maximum current draw is 30amps at 208V, and it's a 3 phase heater with no internal motor?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, based on your specs, recommended frequency converter model: HZ-50-3315, 15kVA power capacity, input: 3ph, Wye (L1, L2, L3 + N, G), 400V (+/- 10%), 50/ 60Hz and output: 3ph, Wye/Delta (L1, L2, L3 + N, G), adjustable (0-260V), adjustable (40-120Hz), 41.6A.
Two questions about frequency converter
5
Balush
Avatar
1/4/2022 6:07 PM
Is your frequency converter CE certified?
What are the quality documents furnished with product supply?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our frequency converter is CE certified,.
For quality document: We provide factory calibration certificate which is done during converter testing stages.
When the power goes the conversation has to be manually reset and started. Is there any way this can be down automatically?
5
Joey
Avatar
9/9/2022 3:28 AM
The communication must be manually restarted when the power goes out. Is there a way to have this shut off automatically?

The converter is located in a retail building, and after a few incidents, the building manager went to check on it and discovered that it was beeping and showing just zeroes. Then, until it was reset and turned on by pressing the red and green buttons, all of the appliances were turned off.

Is there a method to prevent it? I believe it's due to the power loss, but are there any other possible causes? Or did it restart on its own?
Was this review helpful? Yes No (0/0)
ATO Responded
In this situation, you want the converter to have the capability of starting up automatically following a power outage, correct?
You can change the circuit of the start contactor coil KM1 by adding a delay relay KT and setting the delay period to 15 seconds, as shown in the automatic time delay start circuit diagram stated on the detail page above.
Please send me test report for the frequency converter.
5
hymen
Avatar
5/10/2023 1:33 AM
I will have to work on getting that voltage level for you. Just so I understand this, if the phase voltage is set to 120V, then the difference in the measured output line voltage would be the error between the actual output voltage and the display voltage?
Also, would you be able to send me an example test report for the Hz-50-3375 frequency converter as reference, similar to the one you sent me for the 3315 model?
Was this review helpful? Yes No (0/0)
ATO Responded
Please check the attached picture, there is a DIP switch on the machine to select phase voltage/line voltage mode, line voltage=phase voltage*1.732. If you choose phase voltage, the machine will display phase voltage. If you choose line voltage, the machine will display line voltage.
So, if the phase voltage is set to 120V, then the output phase voltage (U-N, V-N, W-N) should be close to 120V, and the line voltage (U-V, V-W, U-W) is equivalent to 207.8V AC. You need to measure the voltage at the output terminal and compare it with the voltage displayed on the display panel of the machine to check how much V is the error between them.
The test report is the same, you can refer to the 15KVA report.
Only registered users can write reviews