DC current sensor has measuring range of 1mA/100mA/1A/2A/5A/10A/50A/100A/200A to 800A.
Specification:
| Model | ATO-CURTS-DZIA | ATO-CURTS-DZIB | ATO-CURTS-DZIC | ATO-CURTS-DZID |
| Shipping weight | 0.5kg | |||
| Measuring range of input current * | DC 0-1mA/ 0-5mA/ 0-20mA/ 0-50mA/ 0-100mA/ 0-500mA/ 0-1A/ 0-5A/ 0-10A | 0-20A/ 0-50A/ 0-100A/ 0-150A | DC 0-50A/ 0-100A/ 0-150A/ 0-200A/ 0-300A/ 0-400A | DC 0-200A/ 0-400A/ 0-500A/ 0-600A/ 0-800A |
| Output signal * | DC 4-20mA, DC 1-5V, DC 0-5V, DC 0-10V (customizable) | |||
| Power supply * | DC 24V, DC 12V, AC 220V, AC 110V (customizable) | |||
| Hole diameter * | No hole | 8mm, 12mm, 15mm | 22mm | 35mm, 45mm, 55mm (customizable) |
| Accuracy | 0.5%F.S. | |||
| Isolation voltage | 3kV/50Hz/1min | |||
| Offset voltage | ≤10mV | |||
| Temperature drift | ≤100PPM/℃ | |||
| Frequency bandwidth | 20~50kHz | |||
| Current consumption | <5mA | |||
| Load capacity | Voltage output: 5mA, current output: 6V | |||
| Response time | <250ms | |||
| Overload capacity | 120% nominal input | |||
| Work temperature | -10~+70℃ | |||
| Storage temperature | -25~+85℃ | |||
| Measuring method | Terminal connection or through-hole type | |||
| Installation | DIN rail and screw fixation | |||
Note: ATO can customize DC bidirectional current sensor with maximum measuring range of -50A~0~50A. For example, the measuring range of input current is -50A ~ 0 ~ +50A, and the output signal is 4-20mA. Then the output signal 4-12mA corresponds to -50A~0, and the output signal 12-20mA corresponds to 0~+50A. And so on for other output signal modes. If you have any questions, please feel free to contact us.
Hole diameter and corresponding current for reference:
| Hole diameter | Current |
| 8mm | 0-20A ~ 0-50A |
| 12mm | 0-50A ~ 0-100A |
| 15mm | 0-100A ~ 0-150A |
| 22mm | 0-150A ~ 0-350A |
| 35mm | 0-350A ~ 0-800A |
| 45mm | 0-800A |
| 55mm | 0-800A |
Dimension and wiring diagram:
Details

Tips: Current sensor applications
- Detect the current harmonics of the electronic equipment absorbing from power grid.
- Detect the slight current waveform distortion in the PWM circuit.
- In spot welder and pulse plating equipment, the Hall effect current sensor can be used to detect the current waveform and the peak voltmeter can be used to test the output voltage of sensor, thus calculating the measured peak current.
- Hall effect current sensor has noninductive characteristic and response quickly. It's most suitable for detecting current signals in overcurrent or short-circuit protection circuits of the electronic equipment, so as to realize a fast protection.
- Hall effect current sensor still has the electrical isolation in DC detection, which expands its application range.
- In the electronic equipment that outputs current, Hall effect current sensor can also be used to obtain DC current signal, so as to realize current feedback, interception control, constant-current regulation, and overcurrent and short-circuit protection at the DC side.
Product reviews
DC current sensor 0-10A
Adrian
4/9/2020 1:41 AM
I want to buy your DC current sensor 0-10A with output signal 4-20mA / no hole. Just one question, will this sensor work at 28VDC power supply?
Was this review helpful? (0/0)
Selection of DC current sensor
Bolger
4/19/2021 9:40 PM
I am looking for DC current model that can be clamped on the dc cable, much like the ct ones for AC.
Was this review helpful? (0/0)
Working voltage of 1mA-800A DC current sensor
Buzgal
5/8/2021 1:37 AM
I would like to use current sensor ATO-CUS-DC800 in an application that uses 28VDC. Will this sensor work at that voltage?
Was this review helpful? (0/0)
The use of 1mA-800A DC current sensor
Danman
8/10/2021 2:34 AM
If I buy a unidirectional current transducer (ATO-CUS-DC800), what happens when the DC line polarity switches? Is there damage to the transducer? Or does the output simply go to 4mA?
Was this review helpful? (0/0)
For your DC current sensor, which panel meter would you recommend?
Carole
10/18/2021 8:54 PM
For your DC current sensor, which panel meter would you suggest?
Was this review helpful? (0/0)
Can your DC current sensor be calibrated?
Wendi
11/23/2021 8:36 PM
Can your DC current sensor be calibrated? Is that what the adjustment screws are in blue?
Was this review helpful? (0/0)
Could you please help clarify the query below?
Grma
1/3/2022 7:09 PM
1)Whether the ATO-CUS-DC800 DC current sensor measures the current max of 4A @ 24V input line (In , In-). Please confirm
2)Whether it withstand the 6A inrush current for 4A current measurement. Please confirm.
2)Whether it withstand the 6A inrush current for 4A current measurement. Please confirm.
Was this review helpful? (0/0)
DC current sensor voltage conversion
faye
2/5/2023 8:38 PM
How do you convert a voltage output from the DC Current Sensor into a current?
Was this review helpful? (0/0)
What is the range of voltages the DC current sensor can take?
eugen
4/6/2023 9:05 PM
I bought your current sensor that takes 110AC power supply. But a common outlet in the US outputs 120AC. Can I input this into the current sensor without damaging it?
What is the range of voltages the sensor can take?
What is the range of voltages the sensor can take?
Was this review helpful? (0/0)
Have a question on the input connection of the current sensor
boris
6/13/2023 1:49 AM
I have just received my current transducer and have a question on the input connection of the equipment.
Would you please review and advise on how the input side is connected to the transducer?
Feel free to contact me if you have any questions.
Would you please review and advise on how the input side is connected to the transducer?
Feel free to contact me if you have any questions.
Was this review helpful? (0/0)
Have a question on output to plc
ALOK
7/31/2023 6:27 AM
Can this device measure AMP for 14 v dc motor and send the result to plc? Also, I need a graph between time and amp so can I do that by using that device?
Was this review helpful? (0/0)
Questions about the range of current sensor
Loren
8/6/2023 7:37 PM
I bought this DC current sensor last week. Can the range be 4-20 ma input and 4-20 ma output?
Was this review helpful? (0/0)
Can this DC current sensor be supported?
Eambay
8/7/2023 12:16 AM
The input will be analog output that can loop through to control input. This DC current sensor will support?
Was this review helpful? (0/0)
Does this mean that the sensor will not read current pulses if they are not at least 150ms?
james
11/26/2023 7:33 PM
The response time is listed as 150ms. Does this mean that the sensor will not read current pulses if they are not at least 150ms? Or is this the communication time of the reading? I have an application that requires to read a pulse that is 0.5ms long.
Was this review helpful? (0/0)
Will negative currents damage the sensor
Tim
1/26/2024 1:39 PM
Hello, I have a 12-pin, no hole (non-hall effect) current sensor. I understand that this sensor will not correctly read negative currents. My question is: will running negative current through the sensor damage it?
Was this review helpful? (0/0)
I have some questions
Aldis
7/24/2024 7:30 PM
I need to find a meter or a circuit to read and display the signal. I think it would be easy for me to stay with the current sensor ATO-CURTS-DZIC (measuring range 0-200A). I still have some questions about this item. Can I use it to measure 20 kHz current? Should this current sensor be compatible with paperless recorders or certain PLCs?
Was this review helpful? (0/0)
PWM Current Sensing
Manuel
2/13/2026 2:39 PM
I need to read the average current through a wire carrying a PWM signal with duty cycle varying from 0 - 100%. The frequency of this signal is on the order of 50 Hz - 100 Hz. I do not need the exact current at any one moment, just the average over time. I saw the response time is <250 ms, so would it average out the PWM signal like a low-pass filter or would it react differently?
Was this review helpful? (0/0)
Measuring bidirectional current
Molden
2/25/2026 11:26 PM
I want to measure the charge/discharge current (DC) of a battery. The current is bidirectional. Are there similar current sensors with a measurement range of -200A to 200A (the outputs for -200A and 200A are different)?
Was this review helpful? (0/0)
Bidirectional DC current sensor inquiry (-50A to 50A)
sigeki
4/8/2026 9:58 PM
For a bidirectional DC current sensor with range -50A to 0 to 50A, can you provide a 0-5V output?
If yes, please confirm whether the scaling is:
-50A = 0V
0A = 2.5V
50A = 5V
If yes, please confirm whether the scaling is:
-50A = 0V
0A = 2.5V
50A = 5V
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
AC Current Sensor, 5mA/100mA/1A/2A/5A to 10A
ATO-CUS-AC10
$72.63
AC current sensor adopts linear photoelectric isolation or modulation and demodulation principle, best cost performance, fast response, high accuracy, good stability, small size, light weight, input current terminal connection, DIN rail installation, widely used for AC current measurement of various occasions.
3 Phase AC Current Transducer 0.5A/1A/2A/5A/10A/20A/50A to 80A
ATO-CUS-3AC80
$161.39
AC current transducer is a special current sensor for 3 phase AC current measurement. Three phase current transducer adopts epoxy resin pouring sealant to ensure the stability of components, with 0.5%FS accuracy, three output signals 4-20mA/0-20mA/0-5V/0-10V, power supply DC 5V/12V/24V, fixed installation. 3 phase AC current transducer is widely used for real-time monitoring of power grid AC current.
AC/DC Voltage Sensor 75mV to 500V, RMS 0-5V/0-10V/4-20mA/0-20mA Output
ATO-VOS-ACDC500
$161.27
Voltage sensor has voltage measuring range from AC/DC 75mV/50V/100V/250V/300V to 500V, supply voltage DC 12V/24V, output DC voltage/current or True RMS voltage/current signal 0-5V/0-10V/0-20mA/4-20mA and protection class IP20. AC/DC voltage sensor has two installation methods, DIN rail installation and M3 screw fixation.
Isolated DC Voltage Sensor 10mV to 1000V, Power Supply DC 12V/24V
ATO-VOS-DC1000
$141.96
DC voltage sensor uses modulation and demodulation technology to achieve input/output/power supply isolation. Isolated voltage transducer has measuring range from DC 10mV/50mV/75mV/5V/150V/300V/500V to 1000V, supply voltage DC 12V/24V, accuracy 0.2%FS, output signal 0-5V/0-10V/0-20mA/4-20mA and strong anti-interference capability. DC voltage sensor is widely used for voltage isolated measuring and control, such as electric power, remote monitoring, medical equipment, etc.
AC Current Sensor 50A/100A/400A/600A/1000A/1200A to 1500A
ATO-CUS-AC1500
$87.36
Hall effect AC current sensors are non-invasive current sensors, with 1.0%FS accuracy, 1ms fast response time, 0-50A ~ 0-1500A measuring range, 4-20mA output signal, 12V/24V power supply, fixed installation, excellent linearity and strong anti-interference capacity. Open loop AC current sensors can be connected to AD, DSP and PLC directly. AC current sensors are now widely used for AC current measurement.