DC Current Sensor 1mA/1A/5A/10A/100A to 800A

$85.56
DC current sensor has best cost performance, fast response, high accuracy, good stability, small size, light weight, DIN rail installation, widely used for DC current measurement of various occasions.
SKU: ATO-CUS-DC800
*
*
Free Shipping
Delivery date: 8-12 days

DC current sensor has measuring range of 1mA/100mA/1A/2A/5A/10A/50A/100A/200A to 800A.

Specification:

ModelATO-CURTS-DZIAATO-CURTS-DZIBATO-CURTS-DZICATO-CURTS-DZID
Shipping weight0.5kg
Measuring range of input current *DC 0-1mA/ 0-5mA/ 0-20mA/ 0-50mA/ 0-100mA/ 0-500mA/ 0-1A/ 0-5A/ 0-10A0-20A/ 0-50A/ 0-100A/ 0-150ADC 0-50A/ 0-100A/ 0-150A/ 0-200A/ 0-300A/ 0-400ADC 0-200A/ 0-400A/ 0-500A/ 0-600A/ 0-800A
Output signal *DC 4-20mA, DC 1-5V, DC 0-5V, DC 0-10V (customizable)
Power supply *DC 24V, DC 12V, AC 220V, AC 110V (customizable)
Hole diameter *No hole8mm, 12mm, 15mm22mm35mm, 45mm, 55mm (customizable)
Accuracy0.5%F.S.
Isolation voltage3kV/50Hz/1min
Offset voltage≤10mV
Temperature drift≤100PPM/℃
Frequency bandwidth20~50kHz
Current consumption<5mA
Load capacityVoltage output: 5mA, current output: 6V
Response time<250ms
Overload capacity120% nominal input
Work temperature-10~+70℃
Storage temperature-25~+85℃
Measuring methodTerminal connection or through-hole type
InstallationDIN rail and screw fixation

Note: ATO can customize DC bidirectional current sensor with maximum measuring range of -50A~0~50A. For example, the measuring range of input current is -50A ~ 0 ~ +50A, and the output signal is 4-20mA. Then the output signal 4-12mA corresponds to -50A~0, and the output signal 12-20mA corresponds to 0~+50A. And so on for other output signal modes. If you have any questions, please feel free to contact us.

Hole diameter and corresponding current for reference:

Hole diameterCurrent
8mm0-20A ~ 0-50A
12mm0-50A ~ 0-100A
15mm0-100A ~ 0-150A
22mm0-150A ~ 0-350A
35mm0-350A ~ 0-800A
45mm0-800A
55mm0-800A

Dimension and wiring diagram:
DC current sensor 1mA to 1000A dimension and wiring

Details

Current Sensor Details

Tips: Current sensor applications

  1. Detect the current harmonics of the electronic equipment absorbing from power grid.
  2. Detect the slight current waveform distortion in the PWM circuit.
  3. In spot welder and pulse plating equipment, the Hall effect current sensor can be used to detect the current waveform and the peak voltmeter can be used to test the output voltage of sensor, thus calculating the measured peak current.
  4. Hall effect current sensor has noninductive characteristic and response quickly. It's most suitable for detecting current signals in overcurrent or short-circuit protection circuits of the electronic equipment, so as to realize a fast protection.
  5. Hall effect current sensor still has the electrical isolation in DC detection, which expands its application range.
  6. In the electronic equipment that outputs current, Hall effect current sensor can also be used to obtain DC current signal, so as to realize current feedback, interception control, constant-current regulation, and overcurrent and short-circuit protection at the DC side.
Product reviews
DC current sensor 0-10A
5
Adrian
Avatar
4/9/2020 1:41 AM
I want to buy your DC current sensor 0-10A with output signal 4-20mA / no hole. Just one question, will this sensor work at 28VDC power supply?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can customize current sensor to run based on 28VDC supply voltage and with the same price stated at the web page. Please send your requirement by email after ordering.
Selection of DC current sensor
5
Bolger
Avatar
4/19/2021 9:40 PM
I am looking for DC current model that can be clamped on the dc cable, much like the ct ones for AC.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we provide. when selecting DC measuring range, you can notice whether it can be provided with hole or not.
Working voltage of 1mA-800A DC current sensor
5
Buzgal
Avatar
5/8/2021 1:37 AM
I would like to use current sensor ATO-CUS-DC800 in an application that uses 28VDC. Will this sensor work at that voltage?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can customized to run based on 28VDC supply voltage and with the same price stated at the web page, just confirm us by email after ordering.
The use of 1mA-800A DC current sensor
5
Danman
Avatar
8/10/2021 2:34 AM
If I buy a unidirectional current transducer (ATO-CUS-DC800), what happens when the DC line polarity switches? Is there damage to the transducer? Or does the output simply go to 4mA?
Was this review helpful? Yes No (0/0)
ATO Responded
When the DC line polarity switches, the output simply goes to 0 mA. It will not damage the transducer, but it is not recommended for that.
For your DC current sensor, which panel meter would you recommend?
5
Carole
Avatar
10/18/2021 8:54 PM
For your DC current sensor, which panel meter would you suggest?
Was this review helpful? Yes No (0/0)
ATO Responded
We need to know required current sensor measuring range, so can recommend the most suited panel meter.
Can your DC current sensor be calibrated?
5
Wendi
Avatar
11/23/2021 8:36 PM
Can your DC current sensor be calibrated? Is that what the adjustment screws are in blue?
Was this review helpful? Yes No (0/0)
ATO Responded
This unit does not need to be calibrated, it should be used directly after purchase as it is already well calibrated before shipping out. The two potentiometers on the sensor are for the factory calibration.
Could you please help clarify the query below?
5
Grma
Avatar
1/3/2022 7:09 PM
1)Whether the ATO-CUS-DC800 DC current sensor measures the current max of 4A @ 24V input line (In , In-). Please confirm
2)Whether it withstand the 6A inrush current for 4A current measurement. Please confirm.
Was this review helpful? Yes No (0/0)
ATO Responded
In the case below, if the current sensor requires it withstand the 6A inrush current for 4A current measurement, we recommend the 0-10A range capacity.
DC current sensor voltage conversion
5
faye
Avatar
2/5/2023 8:38 PM
How do you convert a voltage output from the DC Current Sensor into a current?
Was this review helpful? Yes No (0/0)
ATO Responded
The DC Current Sensor has analog components inside.
This analog circuit can convert the input current signal into an analog output voltage or current signal, no problem.
What is the range of voltages the DC current sensor can take?
5
eugen
Avatar
4/6/2023 9:05 PM
I bought your current sensor that takes 110AC power supply. But a common outlet in the US outputs 120AC. Can I input this into the current sensor without damaging it?
What is the range of voltages the sensor can take?
Was this review helpful? Yes No (0/0)
ATO Responded
What is your order number?
Generally, the voltage input range of the current sensor is 110±10%.
If the input voltage does not exceed 120V, there is no problem.
But the voltage fluctuation to 125V may damage the sensor.
Have a question on the input connection of the current sensor
5
boris
Avatar
6/13/2023 1:49 AM
I have just received my current transducer and have a question on the input connection of the equipment.
Would you please review and advise on how the input side is connected to the transducer?
Feel free to contact me if you have any questions.
Was this review helpful? Yes No (0/0)
ATO Responded
The DC current sensor should be connected in series in the DC circuit, so the second schematic in your attachment is correct, as shown in the picture below.
Have a question on output to plc
5
ALOK
Avatar
7/31/2023 6:27 AM
Can this device measure AMP for 14 v dc motor and send the result to plc? Also, I need a graph between time and amp so can I do that by using that device?
Was this review helpful? Yes No (0/0)
ATO Responded
This device can measure the DC input side current of the DC motor, and you can put it on the DC side for monitoring.
Our equipment will output an analog signal, so you can connect to the analog input module of PLC.
But you need to analyze the output by yourself, we don't provide graphs.
Questions about the range of current sensor
5
Loren
Avatar
8/6/2023 7:37 PM
I bought this DC current sensor last week. Can the range be 4-20 ma input and 4-20 ma output?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the current sensor you bought has a measurement range of 0-20mA, and also supports 4-20mA input and 4-20mA output.
Can this DC current sensor be supported?
5
Eambay
Avatar
8/7/2023 12:16 AM
The input will be analog output that can loop through to control input. This DC current sensor will support?
Was this review helpful? Yes No (0/0)
ATO Responded
The current sensor is only used to measure the DC current 4-20ma at the input end, and output an analog current signal 4-20ma at the output end, but it cannot control the current at the input end.  Current sensors can only measure current signals and convert them into analog signals for output.
Does this mean that the sensor will not read current pulses if they are not at least 150ms?
5
james
Avatar
11/26/2023 7:33 PM
The response time is listed as 150ms. Does this mean that the sensor will not read current pulses if they are not at least 150ms? Or is this the communication time of the reading? I have an application that requires to read a pulse that is 0.5ms long.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the response time is 150ms. This means that the sensor reads the current pulse for no less than 150ms.  Our current sensors are Not available in 0.5ms response time versions.
Will negative currents damage the sensor
5
Tim
Avatar
1/26/2024 1:39 PM
Hello, I have a 12-pin, no hole (non-hall effect) current sensor. I understand that this sensor will not correctly read negative currents. My question is: will running negative current through the sensor damage it?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi Tim,
For our no hole sensor ATO-CURTS-DZIA, negative current will damage this sensor.
I have some questions
4
Aldis
Avatar
7/24/2024 7:30 PM
I need to find a meter or a circuit to read and display the signal. I think it would be easy for me to stay with the current sensor ATO-CURTS-DZIC (measuring range 0-200A). I still have some questions about this item. Can I use it to measure 20 kHz current? Should this current sensor be compatible with paperless recorders or certain PLCs?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The frequency bandwidth of ATO-CURTS-DZIC (measurement range 0-200A) is 20-50kHz, you can use it to measure 20kHz current.
2. This current sensor should be able to work with the paperless recorder or some PLC.
PWM Current Sensing
3
Manuel
Avatar
2/13/2026 2:39 PM
I need to read the average current through a wire carrying a PWM signal with duty cycle varying from 0 - 100%. The frequency of this signal is on the order of 50 Hz - 100 Hz. I do not need the exact current at any one moment, just the average over time. I saw the response time is <250 ms, so would it average out the PWM signal like a low-pass filter or would it react differently?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, this DZI series DC current sensor cannot read the average current of 50Hz~100Hz PWM signals.
The sensor's response time is <250ms. For 50Hz (20ms period) and 100Hz (10ms period) PWM signals, its response speed is much slower than the frequency of the PWM signal. It cannot effectively sample and average the PWM signal in this frequency range, nor can it smooth the PWM signal current to an average current like a low-pass filter. Therefore, it cannot meet your requirements for measuring the average current of PWM signals in this frequency range.
Measuring bidirectional current
5
Molden
Avatar
2/25/2026 11:26 PM
I want to measure the charge/discharge current (DC) of a battery. The current is bidirectional. Are there similar current sensors with a measurement range of -200A to  200A (the outputs for -200A and  200A are different)?
Was this review helpful? Yes No (0/0)
ATO Responded
The ATO-CURTS-DZIC 0-200A cannot measure bidirectional current, but our ATO-AHKC-EKAS can measure bidirectional current, with a +200A output of +5V and a -200A output of -5V.
Bidirectional DC current sensor inquiry (-50A to 50A)
5
sigeki
Avatar
4/8/2026 9:58 PM
For a bidirectional DC current sensor with range -50A to 0 to  50A, can you provide a 0-5V output?

If yes, please confirm whether the scaling is:

-50A = 0V
0A = 2.5V
50A = 5V
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, this DC current sensor cannot achieve -50 to 50A.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

DC current sensor has measuring range of 1mA/100mA/1A/2A/5A/10A/50A/100A/200A to 800A.

Specification:

ModelATO-CURTS-DZIAATO-CURTS-DZIBATO-CURTS-DZICATO-CURTS-DZID
Shipping weight0.5kg
Measuring range of input current *DC 0-1mA/ 0-5mA/ 0-20mA/ 0-50mA/ 0-100mA/ 0-500mA/ 0-1A/ 0-5A/ 0-10A0-20A/ 0-50A/ 0-100A/ 0-150ADC 0-50A/ 0-100A/ 0-150A/ 0-200A/ 0-300A/ 0-400ADC 0-200A/ 0-400A/ 0-500A/ 0-600A/ 0-800A
Output signal *DC 4-20mA, DC 1-5V, DC 0-5V, DC 0-10V (customizable)
Power supply *DC 24V, DC 12V, AC 220V, AC 110V (customizable)
Hole diameter *No hole8mm, 12mm, 15mm22mm35mm, 45mm, 55mm (customizable)
Accuracy0.5%F.S.
Isolation voltage3kV/50Hz/1min
Offset voltage≤10mV
Temperature drift≤100PPM/℃
Frequency bandwidth20~50kHz
Current consumption<5mA
Load capacityVoltage output: 5mA, current output: 6V
Response time<250ms
Overload capacity120% nominal input
Work temperature-10~+70℃
Storage temperature-25~+85℃
Measuring methodTerminal connection or through-hole type
InstallationDIN rail and screw fixation

Note: ATO can customize DC bidirectional current sensor with maximum measuring range of -50A~0~50A. For example, the measuring range of input current is -50A ~ 0 ~ +50A, and the output signal is 4-20mA. Then the output signal 4-12mA corresponds to -50A~0, and the output signal 12-20mA corresponds to 0~+50A. And so on for other output signal modes. If you have any questions, please feel free to contact us.

Hole diameter and corresponding current for reference:

Hole diameterCurrent
8mm0-20A ~ 0-50A
12mm0-50A ~ 0-100A
15mm0-100A ~ 0-150A
22mm0-150A ~ 0-350A
35mm0-350A ~ 0-800A
45mm0-800A
55mm0-800A

Dimension and wiring diagram:
DC current sensor 1mA to 1000A dimension and wiring

Details

Current Sensor Details

Tips: Current sensor applications

  1. Detect the current harmonics of the electronic equipment absorbing from power grid.
  2. Detect the slight current waveform distortion in the PWM circuit.
  3. In spot welder and pulse plating equipment, the Hall effect current sensor can be used to detect the current waveform and the peak voltmeter can be used to test the output voltage of sensor, thus calculating the measured peak current.
  4. Hall effect current sensor has noninductive characteristic and response quickly. It's most suitable for detecting current signals in overcurrent or short-circuit protection circuits of the electronic equipment, so as to realize a fast protection.
  5. Hall effect current sensor still has the electrical isolation in DC detection, which expands its application range.
  6. In the electronic equipment that outputs current, Hall effect current sensor can also be used to obtain DC current signal, so as to realize current feedback, interception control, constant-current regulation, and overcurrent and short-circuit protection at the DC side.
Product reviews
DC current sensor 0-10A
5
Adrian
Avatar
4/9/2020 1:41 AM
I want to buy your DC current sensor 0-10A with output signal 4-20mA / no hole. Just one question, will this sensor work at 28VDC power supply?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can customize current sensor to run based on 28VDC supply voltage and with the same price stated at the web page. Please send your requirement by email after ordering.
Selection of DC current sensor
5
Bolger
Avatar
4/19/2021 9:40 PM
I am looking for DC current model that can be clamped on the dc cable, much like the ct ones for AC.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we provide. when selecting DC measuring range, you can notice whether it can be provided with hole or not.
Working voltage of 1mA-800A DC current sensor
5
Buzgal
Avatar
5/8/2021 1:37 AM
I would like to use current sensor ATO-CUS-DC800 in an application that uses 28VDC. Will this sensor work at that voltage?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can customized to run based on 28VDC supply voltage and with the same price stated at the web page, just confirm us by email after ordering.
The use of 1mA-800A DC current sensor
5
Danman
Avatar
8/10/2021 2:34 AM
If I buy a unidirectional current transducer (ATO-CUS-DC800), what happens when the DC line polarity switches? Is there damage to the transducer? Or does the output simply go to 4mA?
Was this review helpful? Yes No (0/0)
ATO Responded
When the DC line polarity switches, the output simply goes to 0 mA. It will not damage the transducer, but it is not recommended for that.
For your DC current sensor, which panel meter would you recommend?
5
Carole
Avatar
10/18/2021 8:54 PM
For your DC current sensor, which panel meter would you suggest?
Was this review helpful? Yes No (0/0)
ATO Responded
We need to know required current sensor measuring range, so can recommend the most suited panel meter.
Can your DC current sensor be calibrated?
5
Wendi
Avatar
11/23/2021 8:36 PM
Can your DC current sensor be calibrated? Is that what the adjustment screws are in blue?
Was this review helpful? Yes No (0/0)
ATO Responded
This unit does not need to be calibrated, it should be used directly after purchase as it is already well calibrated before shipping out. The two potentiometers on the sensor are for the factory calibration.
Could you please help clarify the query below?
5
Grma
Avatar
1/3/2022 7:09 PM
1)Whether the ATO-CUS-DC800 DC current sensor measures the current max of 4A @ 24V input line (In , In-). Please confirm
2)Whether it withstand the 6A inrush current for 4A current measurement. Please confirm.
Was this review helpful? Yes No (0/0)
ATO Responded
In the case below, if the current sensor requires it withstand the 6A inrush current for 4A current measurement, we recommend the 0-10A range capacity.
DC current sensor voltage conversion
5
faye
Avatar
2/5/2023 8:38 PM
How do you convert a voltage output from the DC Current Sensor into a current?
Was this review helpful? Yes No (0/0)
ATO Responded
The DC Current Sensor has analog components inside.
This analog circuit can convert the input current signal into an analog output voltage or current signal, no problem.
What is the range of voltages the DC current sensor can take?
5
eugen
Avatar
4/6/2023 9:05 PM
I bought your current sensor that takes 110AC power supply. But a common outlet in the US outputs 120AC. Can I input this into the current sensor without damaging it?
What is the range of voltages the sensor can take?
Was this review helpful? Yes No (0/0)
ATO Responded
What is your order number?
Generally, the voltage input range of the current sensor is 110±10%.
If the input voltage does not exceed 120V, there is no problem.
But the voltage fluctuation to 125V may damage the sensor.
Have a question on the input connection of the current sensor
5
boris
Avatar
6/13/2023 1:49 AM
I have just received my current transducer and have a question on the input connection of the equipment.
Would you please review and advise on how the input side is connected to the transducer?
Feel free to contact me if you have any questions.
Was this review helpful? Yes No (0/0)
ATO Responded
The DC current sensor should be connected in series in the DC circuit, so the second schematic in your attachment is correct, as shown in the picture below.
Have a question on output to plc
5
ALOK
Avatar
7/31/2023 6:27 AM
Can this device measure AMP for 14 v dc motor and send the result to plc? Also, I need a graph between time and amp so can I do that by using that device?
Was this review helpful? Yes No (0/0)
ATO Responded
This device can measure the DC input side current of the DC motor, and you can put it on the DC side for monitoring.
Our equipment will output an analog signal, so you can connect to the analog input module of PLC.
But you need to analyze the output by yourself, we don't provide graphs.
Questions about the range of current sensor
5
Loren
Avatar
8/6/2023 7:37 PM
I bought this DC current sensor last week. Can the range be 4-20 ma input and 4-20 ma output?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the current sensor you bought has a measurement range of 0-20mA, and also supports 4-20mA input and 4-20mA output.
Can this DC current sensor be supported?
5
Eambay
Avatar
8/7/2023 12:16 AM
The input will be analog output that can loop through to control input. This DC current sensor will support?
Was this review helpful? Yes No (0/0)
ATO Responded
The current sensor is only used to measure the DC current 4-20ma at the input end, and output an analog current signal 4-20ma at the output end, but it cannot control the current at the input end.  Current sensors can only measure current signals and convert them into analog signals for output.
Does this mean that the sensor will not read current pulses if they are not at least 150ms?
5
james
Avatar
11/26/2023 7:33 PM
The response time is listed as 150ms. Does this mean that the sensor will not read current pulses if they are not at least 150ms? Or is this the communication time of the reading? I have an application that requires to read a pulse that is 0.5ms long.
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the response time is 150ms. This means that the sensor reads the current pulse for no less than 150ms.  Our current sensors are Not available in 0.5ms response time versions.
Will negative currents damage the sensor
5
Tim
Avatar
1/26/2024 1:39 PM
Hello, I have a 12-pin, no hole (non-hall effect) current sensor. I understand that this sensor will not correctly read negative currents. My question is: will running negative current through the sensor damage it?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi Tim,
For our no hole sensor ATO-CURTS-DZIA, negative current will damage this sensor.
I have some questions
4
Aldis
Avatar
7/24/2024 7:30 PM
I need to find a meter or a circuit to read and display the signal. I think it would be easy for me to stay with the current sensor ATO-CURTS-DZIC (measuring range 0-200A). I still have some questions about this item. Can I use it to measure 20 kHz current? Should this current sensor be compatible with paperless recorders or certain PLCs?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The frequency bandwidth of ATO-CURTS-DZIC (measurement range 0-200A) is 20-50kHz, you can use it to measure 20kHz current.
2. This current sensor should be able to work with the paperless recorder or some PLC.
PWM Current Sensing
3
Manuel
Avatar
2/13/2026 2:39 PM
I need to read the average current through a wire carrying a PWM signal with duty cycle varying from 0 - 100%. The frequency of this signal is on the order of 50 Hz - 100 Hz. I do not need the exact current at any one moment, just the average over time. I saw the response time is <250 ms, so would it average out the PWM signal like a low-pass filter or would it react differently?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, this DZI series DC current sensor cannot read the average current of 50Hz~100Hz PWM signals.
The sensor's response time is <250ms. For 50Hz (20ms period) and 100Hz (10ms period) PWM signals, its response speed is much slower than the frequency of the PWM signal. It cannot effectively sample and average the PWM signal in this frequency range, nor can it smooth the PWM signal current to an average current like a low-pass filter. Therefore, it cannot meet your requirements for measuring the average current of PWM signals in this frequency range.
Measuring bidirectional current
5
Molden
Avatar
2/25/2026 11:26 PM
I want to measure the charge/discharge current (DC) of a battery. The current is bidirectional. Are there similar current sensors with a measurement range of -200A to  200A (the outputs for -200A and  200A are different)?
Was this review helpful? Yes No (0/0)
ATO Responded
The ATO-CURTS-DZIC 0-200A cannot measure bidirectional current, but our ATO-AHKC-EKAS can measure bidirectional current, with a +200A output of +5V and a -200A output of -5V.
Bidirectional DC current sensor inquiry (-50A to 50A)
5
sigeki
Avatar
4/8/2026 9:58 PM
For a bidirectional DC current sensor with range -50A to 0 to  50A, can you provide a 0-5V output?

If yes, please confirm whether the scaling is:

-50A = 0V
0A = 2.5V
50A = 5V
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, this DC current sensor cannot achieve -50 to 50A.
Only registered users can write reviews
Customers who bought this item also bought

AC Current Sensor, 5mA/100mA/1A/2A/5A to 10A

ATO-CUS-AC10
$72.63
AC current sensor adopts linear photoelectric isolation or modulation and demodulation principle, best cost performance, fast response, high accuracy, good stability, small size, light weight, input current terminal connection, DIN rail installation, widely used for AC current measurement of various occasions.

3 Phase AC Current Transducer 0.5A/1A/2A/5A/10A/20A/50A to 80A

ATO-CUS-3AC80
$161.39
AC current transducer is a special current sensor for 3 phase AC current measurement. Three phase current transducer adopts epoxy resin pouring sealant to ensure the stability of components, with 0.5%FS accuracy, three output signals 4-20mA/0-20mA/0-5V/0-10V, power supply DC 5V/12V/24V, fixed installation. 3 phase AC current transducer is widely used for real-time monitoring of power grid AC current.

AC/DC Voltage Sensor 75mV to 500V, RMS 0-5V/0-10V/4-20mA/0-20mA Output

ATO-VOS-ACDC500
$161.27
Voltage sensor has voltage measuring range from AC/DC 75mV/50V/100V/250V/300V to 500V, supply voltage DC 12V/24V, output DC voltage/current or True RMS voltage/current signal 0-5V/0-10V/0-20mA/4-20mA and protection class IP20. AC/DC voltage sensor has two installation methods, DIN rail installation and M3 screw fixation.

Isolated DC Voltage Sensor 10mV to 1000V, Power Supply DC 12V/24V

ATO-VOS-DC1000
$141.96
DC voltage sensor uses modulation and demodulation technology to achieve input/output/power supply isolation. Isolated voltage transducer has measuring range from DC 10mV/50mV/75mV/5V/150V/300V/500V to 1000V, supply voltage DC 12V/24V, accuracy 0.2%FS, output signal 0-5V/0-10V/0-20mA/4-20mA and strong anti-interference capability. DC voltage sensor is widely used for voltage isolated measuring and control, such as electric power, remote monitoring, medical equipment, etc.

AC Current Sensor 50A/100A/400A/600A/1000A/1200A to 1500A

ATO-CUS-AC1500
$87.36
Hall effect AC current sensors are non-invasive current sensors, with 1.0%FS accuracy, 1ms fast response time, 0-50A ~ 0-1500A measuring range, 4-20mA output signal, 12V/24V power supply, fixed installation, excellent linearity and strong anti-interference capacity. Open loop AC current sensors can be connected to AD, DSP and PLC directly. AC current sensors are now widely used for AC current measurement.