Isolated DC Voltage Sensor 10mV to 1000V, Power Supply DC 12V/24V

$141.96
DC voltage sensor uses modulation and demodulation technology to achieve input/output/power supply isolation. Isolated voltage transducer has measuring range from DC 10mV/50mV/75mV/5V/150V/300V/500V to 1000V, supply voltage DC 12V/24V, accuracy 0.2%FS, output signal 0-5V/0-10V/0-20mA/4-20mA and strong anti-interference capability. DC voltage sensor is widely used for voltage isolated measuring and control, such as electric power, remote monitoring, medical equipment, etc.
SKU: ATO-VOS-DC1000
*
*
*
Free Shipping
Delivery date: 8-12 days

DC voltage sensor has measuring range of 10mV/50mV/75mV/5V/50V/150V/200V/300V/400V/500V/750V to 1000V.

Specification:

ModelATO-WBV342U01-SATO-WBV342U05-SATO-WBV344U01-SATO-WBV344U05-S
Shipping weight1kg
Measuring range of input voltage *DC 0-10mV ~ 0-1000V
Short-time overload2 times of nominal input voltage, 1s in duration, interval time 10s, repeat 10 times
Linear measurement range0% ~ 120% measuring range
Input impedanceWhen Ux>1V, Ri=Ux*10kΩ/V; when Ux≤1V, Ri≥1MΩ
Output signal *DC 0-5V, 0-10V (only for power supply DC 24V)DC 0-5V, 0-10V (only for power supply DC 24V)DC 0-20mA, 4-20mADC 0-20mA, 4-20mA
Power supply *DC 12V, 24V
Accuracy0.2%F.S.
Load capacity10mA10mA≤300Ω≤300Ω
Response time≤150ms
Temperature drift200*10-6/℃
Static current≤12mA≤30mAOutput 0-20mA: ≤16mA
Output 4-20mA: ≤20mA
Output 0-20mA: ≤29mA
Output 4-20mA: ≤33mA
Isolation features *Isolation between input and output (output terminals provides power supply)Isolation between input, output and power supplyIsolation between input and output (output terminals provides power supply)Isolation between input, output and power supply
Isolation voltageDC 2.5kV, 1mA, 1 min
Work temperature-25~+70℃
Storage temperature-25~+70℃
Protection featuresSurge: 2kV
Electrostatic discharge: 6kV/8kV
Electrical fast transient burst: 2kV
Mean time between failures>50000h
Housing materialFire-retardant ABS
WiringTerminal connection
InstallationDIN rail (NS35/7.5, NS35/15, EN50022)

DC voltage sensor 10mV to 1000V dimensional drawing (unit: mm):
Isolated DC voltage sensor 10mV to 1000V dimension
DC voltage sensor 10mV to 1000V wiring diagram:
(The left diagram is for isolation between input and output, the right diagram is for isolation between input, output and power supply. 1: U≤600V, 4: U>600V)
Isolated DC voltage sensor 10mV to 1000V wiring

10mV-1000V DC voltage sensor wiring

Tips: What is the effect of voltage sensor?
A voltage sensor is a sensor that can sense the measured voltage and convert it into a usable output signal. In various automatic detection and control systems, it is often necessary to track and acquire high-speed changing AC and DC voltage signals, and perform spectrum analysis on more complex voltage waveforms. This type of signal may be a strong voltage such as a high voltage or a large current, or it may be a weak current with a poor load capacity or a signal with small amplitude. In these cases, it is necessary to use appropriate voltage sensors to collect voltage signals that cannot be directly measured or mismatched, so as to obtain standardized and electrically isolated voltage signals.

Product reviews
Works excellent for my application!
5
Quentin
Avatar
7/26/2021 2:05 AM
This AC voltage sensor is great product for the price. I use it as an isolated voltage to read for my power monitoring project. The low voltage signal ensures that I can read and correlate to the line voltage. For reading voltage is certainly working great. It also has high quality control of the heatsink attach.
Was this review helpful? Yes No (0/0)
How deep are those terminals?
5
Bezh
Avatar
3/27/2023 7:34 PM
For the terminals, the wire diameter cannot be larger than 2.5mm2.  We are creating wire harness drawings and need to know how much to strip the wire for installation.  How deep are those terminals?
Was this review helpful? Yes No (0/0)
ATO Responded
The cable insertion depth is 6mm-8mm on it. Complete part number may be neutral BV344U05-S, of course, you can also continue to order directly on our website (refer to the options in the following chart): https://www.ato.com/isolated-dc-voltage-sensor-10mv-to-1000v
High measuring range
4
Lucien
Avatar
9/19/2023 3:14 AM
This sensor has a wide range of voltage measurements to meet the needs of different applications, from low to high voltages can be measured accurately. It provides an isolation function that effectively isolates inputs and outputs, reducing interference and potential safety risks in the circuit. However, this transducer is designed for DC voltage measurement and is not suitable for AC voltage measurement, so it is not suitable in applications where AC voltage measurement is required.
Was this review helpful? Yes No (0/0)
Some Questions
5
Tona
Avatar
7/10/2026 12:21 AM
Hello, I'm considering using the ATO-WBV344U05-S, but I have a few questions before purchasing:
1. Does this 50mV ripple voltage sensor use internal AC coupling to block DC bias, or does it measure the total DC voltage?
2. What is its measurement bandwidth/frequency response? Can it measure ripple in the 100–200 kHz range?
3. Can I connect it to the output of a 24VDC power supply to measure only the AC ripple component?
Was this review helpful? Yes No (0/0)
ATO Responded
1. It uses AC coupling to block DC bias.
2. Unfortunately, it cannot measure ripple in the 100–200 kHz range.
3. No, this function is not available.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

DC voltage sensor has measuring range of 10mV/50mV/75mV/5V/50V/150V/200V/300V/400V/500V/750V to 1000V.

Specification:

ModelATO-WBV342U01-SATO-WBV342U05-SATO-WBV344U01-SATO-WBV344U05-S
Shipping weight1kg
Measuring range of input voltage *DC 0-10mV ~ 0-1000V
Short-time overload2 times of nominal input voltage, 1s in duration, interval time 10s, repeat 10 times
Linear measurement range0% ~ 120% measuring range
Input impedanceWhen Ux>1V, Ri=Ux*10kΩ/V; when Ux≤1V, Ri≥1MΩ
Output signal *DC 0-5V, 0-10V (only for power supply DC 24V)DC 0-5V, 0-10V (only for power supply DC 24V)DC 0-20mA, 4-20mADC 0-20mA, 4-20mA
Power supply *DC 12V, 24V
Accuracy0.2%F.S.
Load capacity10mA10mA≤300Ω≤300Ω
Response time≤150ms
Temperature drift200*10-6/℃
Static current≤12mA≤30mAOutput 0-20mA: ≤16mA
Output 4-20mA: ≤20mA
Output 0-20mA: ≤29mA
Output 4-20mA: ≤33mA
Isolation features *Isolation between input and output (output terminals provides power supply)Isolation between input, output and power supplyIsolation between input and output (output terminals provides power supply)Isolation between input, output and power supply
Isolation voltageDC 2.5kV, 1mA, 1 min
Work temperature-25~+70℃
Storage temperature-25~+70℃
Protection featuresSurge: 2kV
Electrostatic discharge: 6kV/8kV
Electrical fast transient burst: 2kV
Mean time between failures>50000h
Housing materialFire-retardant ABS
WiringTerminal connection
InstallationDIN rail (NS35/7.5, NS35/15, EN50022)

DC voltage sensor 10mV to 1000V dimensional drawing (unit: mm):
Isolated DC voltage sensor 10mV to 1000V dimension
DC voltage sensor 10mV to 1000V wiring diagram:
(The left diagram is for isolation between input and output, the right diagram is for isolation between input, output and power supply. 1: U≤600V, 4: U>600V)
Isolated DC voltage sensor 10mV to 1000V wiring

10mV-1000V DC voltage sensor wiring

Tips: What is the effect of voltage sensor?
A voltage sensor is a sensor that can sense the measured voltage and convert it into a usable output signal. In various automatic detection and control systems, it is often necessary to track and acquire high-speed changing AC and DC voltage signals, and perform spectrum analysis on more complex voltage waveforms. This type of signal may be a strong voltage such as a high voltage or a large current, or it may be a weak current with a poor load capacity or a signal with small amplitude. In these cases, it is necessary to use appropriate voltage sensors to collect voltage signals that cannot be directly measured or mismatched, so as to obtain standardized and electrically isolated voltage signals.

Product reviews
Works excellent for my application!
5
Quentin
Avatar
7/26/2021 2:05 AM
This AC voltage sensor is great product for the price. I use it as an isolated voltage to read for my power monitoring project. The low voltage signal ensures that I can read and correlate to the line voltage. For reading voltage is certainly working great. It also has high quality control of the heatsink attach.
Was this review helpful? Yes No (0/0)
How deep are those terminals?
5
Bezh
Avatar
3/27/2023 7:34 PM
For the terminals, the wire diameter cannot be larger than 2.5mm2.  We are creating wire harness drawings and need to know how much to strip the wire for installation.  How deep are those terminals?
Was this review helpful? Yes No (0/0)
ATO Responded
The cable insertion depth is 6mm-8mm on it. Complete part number may be neutral BV344U05-S, of course, you can also continue to order directly on our website (refer to the options in the following chart): https://www.ato.com/isolated-dc-voltage-sensor-10mv-to-1000v
High measuring range
4
Lucien
Avatar
9/19/2023 3:14 AM
This sensor has a wide range of voltage measurements to meet the needs of different applications, from low to high voltages can be measured accurately. It provides an isolation function that effectively isolates inputs and outputs, reducing interference and potential safety risks in the circuit. However, this transducer is designed for DC voltage measurement and is not suitable for AC voltage measurement, so it is not suitable in applications where AC voltage measurement is required.
Was this review helpful? Yes No (0/0)
Some Questions
5
Tona
Avatar
7/10/2026 12:21 AM
Hello, I'm considering using the ATO-WBV344U05-S, but I have a few questions before purchasing:
1. Does this 50mV ripple voltage sensor use internal AC coupling to block DC bias, or does it measure the total DC voltage?
2. What is its measurement bandwidth/frequency response? Can it measure ripple in the 100–200 kHz range?
3. Can I connect it to the output of a 24VDC power supply to measure only the AC ripple component?
Was this review helpful? Yes No (0/0)
ATO Responded
1. It uses AC coupling to block DC bias.
2. Unfortunately, it cannot measure ripple in the 100–200 kHz range.
3. No, this function is not available.
Only registered users can write reviews
Customers who bought this item also bought

DC Current Sensor 1mA/1A/5A/10A/100A to 800A

ATO-CUS-DC800
$85.56
DC current sensor has best cost performance, fast response, high accuracy, good stability, small size, light weight, DIN rail installation, widely used for DC current measurement of various occasions.

DC Current Sensor 50A/100A/200A/500A/1000A to 1500A

ATO-CUS-DC1500
$83.25
Hall effect DC current sensors are open loop current sensors, with split-core structure, 1ms fast response time, 1.0%FS accuracy, 4-20mA output signal, 12V/24V power supply, fixed installation, excellent linearity and strong anti-interference capacity. DC current sensors are widely used for DC current monitoring, system signal acquisition and feedback control.

AC Current Sensor, AC 200A/400A/600A/800A

ATO-CUS-AC800
$88.25
AC current sensor adopts electromagnetic isolation principle, small size, light weight, low price, fast response, high accuracy, good stability, 35mm/45mm/55mm hole diameter, and screws fixed installation. AC current sensor is widely used for AC current measurement of various occasions, especially for sine-wave ac current with power frequency 50Hz.

AC Voltage Sensor, Range 10V to 1000V, Power Supply DC 12V/24V/36V

ATO-VOS-AC1000
$174.92
AC voltage sensors have voltage measuring range from 10V/50V/100V/200V/500V/800V to 1000V, supply voltage DC 9V~36V, work temperature -25~+70℃, frequency range 25Hz ~ 3kHz and good EMC design. Voltage sensors have two installation methods, DIN rail installation and M3 screw fixation.

Current Sensor AC/DC 0~1mA/10mA/50mA/0.5A/1A/5A

ATO-CUS-ACDC5
$126.37
Current sensors are AC/DC universal current sensors, with a low current measuring range from milliamp current 1mA to 5A. AC/DC current sensors adopt linear photoelectric isolation or modulation and demodulation principle, fast response, 0.5%FS high accuracy, good stability, small size, light weight, input current terminal connection, DIN rail installation. Isolated current sensors are widely used for AC sine wave current or DC bidirectional current measurement.