AC current sensor has measuring range of 5mA/100mA/1A/2A/5A to 10A.
Specification:
| Model | ATO-CURTS-DJIA |
| Shipping weight | 0.5kg |
| Measuring range of input current * | AC 0-10A |
| Output signal * | DC 4-20mA, DC 0-20mA, DC 1-5V, DC 0-5V, DC 0-10V (customizable) |
| Power supply * | DC 24V, DC 12V, AC 220V (customizable) |
| Accuracy | 0.5%F.S. |
| Isolation voltage | 3kV/50Hz/1min |
| Offset voltage | ≤10mV |
| Temperature drift | ≤100PPM/℃ |
| Frequency bandwidth | 20~50Hz |
| Current consumption | <5mA |
| Load capacity | Voltage output: 5mA, current output: 6V |
| Response time | Photoelectric isolation: ≤15μs, modulation and demodulation: <150ms |
| Overload capacity | 10 times nominal input |
| Work temperature | -10~+70℃ |
| Storage temperature | -25~+85℃ |
| Measuring method | Terminal connection |
| Installation | DIN rail and screw fixation |
Dimension and wiring diagram:
Details

Tips: Applications of the Hall effect current sensor
- Application in DC automation speed control system: In this system, the Hall effect current and voltage sensor can directly replace the current transformer. It not only has a better dynamic response, but also realizes the optimal control of rotor current and overload protection for thyristor.
- Application in Uninterruptible Power Supply (UPS): Controlling with a Hall effect AC current sensor can ensure the normal operation of the inverter. Send out signals with Hall effect current sensor 1 and feedback to control the trigger angle of the thyristor. Control the inverter with the signal sent out by Hall effect current sensor 2. And control the float charging power supply with Hall effect current sensor 3. Due to the quick response, Hall effect current sensor is especially suitable for uninterruptible power supply in reduction gears.
- Application in electronic spot welder: Hall effect AC current sensor plays the role of measurement and control in power supply of the electronic spot welder. Its quick response can reproduce the current and voltage waveforms and feedback them to the controllable rectifier A and B, thus controlling its output. If an AC is added to the DC with a chopper, the current can be controlled more accurately. When detecting the current with Hall effect current sensor, real instantaneous value of the current can be measured while no additional loss would be introduced.
- Application in power management: Hall effect AC current sensor can be installed on the distribution line for load management. Output of the Hall effect current sensor is connected with the reduction gear to monitor the electricity consumption. In case of overload, it disconnects the controlled line in time to guarantee the safety of electric equipment. Such a device can also be used for load distribution and remote control, telemetry and patrol of power network.
Product reviews
High accuracy current sensor
Caleb
9/17/2018 7:16 PM
The accuracy of 5A AC current sensor is high, and it is slightly higher than the calibration parameter. The measured data error is very small. This shipment is faster than the last time.
Was this review helpful? (0/0)
Could you please help clarify the query below?
Schafer
12/31/2021 2:17 AM
1)Whether the ATO-CUS-DC800 DC current sensor measures the current max of 4A @ 24V input line (In , In-). Please confirm.
2)Whether it withstand the 6A inrush current for 4A current measurement. Please confirm.
2)Whether it withstand the 6A inrush current for 4A current measurement. Please confirm.
Was this review helpful? (0/0)
Looking for a current sensor
Windsor
5/8/2025 9:00 PM
We are looking for a current sensor with the following specifications:
- Withstands up to 400 VDC
- Suitable for automotive applications
- Minimum IP67 rating
- Maximum temperature limit of 75℃ or higher
- DIN rail compatible package preferred
We would like to know if the following model ATO-CURTS-DJIA is available in 2A, 3A and 5A versions.
- Withstands up to 400 VDC
- Suitable for automotive applications
- Minimum IP67 rating
- Maximum temperature limit of 75℃ or higher
- DIN rail compatible package preferred
We would like to know if the following model ATO-CURTS-DJIA is available in 2A, 3A and 5A versions.
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
DC Current Sensor 1mA/1A/5A/10A/100A to 800A
ATO-CUS-DC800
$85.56
DC current sensor has best cost performance, fast response, high accuracy, good stability, small size, light weight, DIN rail installation, widely used for DC current measurement of various occasions.
3 Phase AC Current Transducer 0.5A/1A/2A/5A/10A/20A/50A to 80A
ATO-CUS-3AC80
$161.39
AC current transducer is a special current sensor for 3 phase AC current measurement. Three phase current transducer adopts epoxy resin pouring sealant to ensure the stability of components, with 0.5%FS accuracy, three output signals 4-20mA/0-20mA/0-5V/0-10V, power supply DC 5V/12V/24V, fixed installation. 3 phase AC current transducer is widely used for real-time monitoring of power grid AC current.
AC/DC Voltage Sensor 75mV to 500V, RMS 0-5V/0-10V/4-20mA/0-20mA Output
ATO-VOS-ACDC500
$161.27
Voltage sensor has voltage measuring range from AC/DC 75mV/50V/100V/250V/300V to 500V, supply voltage DC 12V/24V, output DC voltage/current or True RMS voltage/current signal 0-5V/0-10V/0-20mA/4-20mA and protection class IP20. AC/DC voltage sensor has two installation methods, DIN rail installation and M3 screw fixation.
AC Current Sensor 50A/100A/400A/600A/1000A/1200A to 1500A
ATO-CUS-AC1500
$87.36
Hall effect AC current sensors are non-invasive current sensors, with 1.0%FS accuracy, 1ms fast response time, 0-50A ~ 0-1500A measuring range, 4-20mA output signal, 12V/24V power supply, fixed installation, excellent linearity and strong anti-interference capacity. Open loop AC current sensors can be connected to AD, DSP and PLC directly. AC current sensors are now widely used for AC current measurement.
AC Voltage Sensor, Range 10V to 1000V, Power Supply DC 12V/24V/36V
ATO-VOS-AC1000
$174.92
AC voltage sensors have voltage measuring range from 10V/50V/100V/200V/500V/800V to 1000V, supply voltage DC 9V~36V, work temperature -25~+70℃, frequency range 25Hz ~ 3kHz and good EMC design. Voltage sensors have two installation methods, DIN rail installation and M3 screw fixation.