2 hp VFD, Single Phase to Three Phase VFD

$183.16
2 hp VFD, convert single phase to three phase for AC motor speed controls, 7 amps, IP20, RS485 enabled, manufacturer direct sale.
SKU: GK3000-2S0015
Availability: In stock
Free Shipping
Delivery date: 2-3 days

2 hp VFD, 1.5 kW, 1 phase 220-240V AC to three phase variable frequency drive, normal working temperature –10℃~ +40℃, sale by manufacturer directly.

Specification:

BasicsModelGK3000-2S0015
Capacity2 hp (1.5 kW)
Shipping weight2 kg
Dimension142*85*113 mm
I/O FeatureRated current7 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

1500W VFD Single Phase to Three Phase VFD Details

Tips: Variable Frequency Drive Wiring Specification Standard
Signal line and power line must be separated: When using analog signals for remote control of the VFD, in order to reduce interference, the signal line and strong circuit (main circuit and sequential circuit) should be separated, and the distance should be above 30cm. Even in the control cabinet, the wiring specification should be maintained. The maximum length of the control circuit between the signal and the VFD should not exceed 50m.
Signal lines and power lines must be placed in different metal conduits or metal hose: If the PLC and the VFD signal line are not placed in metal conduit, it will be easily affected by the external interference and VFD. For there is no built-in reactor, the VFD input and output power line will have a strong interference on the outside, so the metal conduit or metal hose must be extended to the VFD control terminal to ensure that the signal line thoroughly separate from the power line.

  1. Analog control signal line should be used double stranded shielded wire, wire size 0.75mm2. In the wiring must note that the cable stripping should be as short as possible (5-7mm). The stripped shield layer should be wrapped with insulating tape to prevent introduce interference from shielded cable and other equipment.
  2. In order to improve the wiring simplicity and reliability, the signal line using pressure wire rod terminal is recommended.

VFD Analog Input 0-10V Frequency Control (VI Port)

In this video, the ATO GK3000 inverter uses external voltage analog quantity to control the frequency, thereby achieving the purpose of motor speed regulation.

VFD Programming for Stabilizing Water Pressure in Water Supply System

In this video, we explore how to use ATO's VFD to ensure stable water pressure in your water supply system. We have covered the complete process from wiring, parameter setting and test run.

VFD Frequency Setting to 400Hz

In this video we show you a step-by-step guide on how to set the frequency of ATO's GK3000 VFD to 400Hz.

VFD Basic Troubleshooting Guide

In this video, ATO will show you the vfd basic troubleshooting guide.

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
How do I connect my motor to the VFD?
5
Osman
Avatar
5/10/2018 7:32 PM
I received this 2hp VFD today in perfect condition.  So, thank you for the fast delivery.

I do however have one question that the very informative user manual doesn't seem to cover.  
How do I connect my motor to the VFD? The motor will be used to drive a fan for a kitchen exhaust and is quite oversized to deliver enough suction when running derated on low rpm / low torque.
If you would be so kind to enlighten me on this matter, it would be greatly appreciated.
Was this review helpful? Yes No (0/0)
ATO Responded
Connect your single phase supply to VFD's R&S terminals and connect your motor to U&V&W terminals.
E is ground terminal.
PA.01Motor rated voltage
5
Vincent
Avatar
1/11/2020 9:02 AM
is PA.01Motor rated voltage your line voltage?
I live in the EU can i put it on 380v on star confugiration? and on 220v in delta?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Input voltage To VFD should be 1-phase, 220/230V.
2. Your motor should be configured To 3-phase, Delta, 220V.
3. Set PA.01 To 220V.
A question for 2 hp VFD
5
nortin
Avatar
2/3/2023 12:31 AM
I just ordered 2hp VFD. I've read the manual, but I'm not seeing what size potentiometer I need for the external speed control.
Was this review helpful? Yes No (0/0)
ATO Responded
The VFD potentiometer is generally 4.7KΩ-10KΩ (for any VFD capacity).
Please refer to our demo video, see on: https://www.youtube.com/watch?v=TJsN1gW8hVQ&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=11
Is it possible with the installation of a physical analog switch?
5
Paulo
Avatar
3/21/2023 7:11 PM
I need to be able to reverse the motor rotation using the keypad. Is that possible? Or is it possible with the installation of a physical analog switch? On my VFD, I have a FWD/REV switch on the panel. I've looked through the manual, but it does not have the F8-13=0 parameter to enable reverse rotation permission listed.
Was this review helpful? Yes No (0/0)
ATO Responded
If you want to operate forward and reverse through the VFD panel, you can set F7-01=2, press the MF.K key on the panel to switch between forward and reverse, reverse when the DIR light is on, and forward when it is off. But if you want the VFD to rotate forward by one key and reverse by the other key, you can only control it through the terminal.
How to set VFD?
5
lillian
Avatar
6/6/2023 11:57 PM
My client has an ATO GK3000 VFD installed at one of their sites in Texas, USA. (See attached pictures for make/model)
We have been unable to communicate with it via PLC hardwired controls. We want to use hardwired (terminal) signals for speed feedback, speed setpoint, forward run command, run feedback and trip feedback. We have also changed the following VFD parameters:
We need your support in setting this VFD up. Looking forward to your support.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry for the late response.
The PA parameter group does not need to be set, and the motor frequency and voltage are set to P0.07 and P0.08.
If the PLC can not communicate, you need to check the PLC program. The inverter communication protocol address is in chapter 9 of the inverter manual, page P160.
Please refer to the link for the manual: https://www.ato.com/Content/doc/ato-gk3000-series-vfd-user-manual.pdf
Do I need set parameters in VFD P0.0 and onwards?
5
gene
Avatar
6/7/2023 1:20 AM
Thank you for the response. I am trying to communicate via the hardwired signals and get information via MODBUS. In that case do I need to set any other parameters in P0.0 and onwards?
Was this review helpful? Yes No (0/0)
ATO Responded
No, you do not need to set any other parameters in P0.0 and onwards.
What the minimum voltage is that this VFD can function at?
5
trond
Avatar
7/24/2023 8:15 PM
Can you confirm what the minimum voltage is that this VFD can function at?
We measured our voltage at our 240V receptacle and it is outputting 204V.
Was this review helpful? Yes No (0/0)
ATO Responded
The minimum input voltage of GK3000-2S0015 is 150V, and the output voltage is 0-input voltage.
I need this VFD to output 60Hz
5
arkle
Avatar
7/24/2023 11:35 PM
I need it to output 60Hz, and the one we received appears to be rated at 220V 50Hz for its maximum output.
When I discussed this with the person on your website it was supposed to be rated for 230/240V 60Hz 3-phase output.
Was this review helpful? Yes No (0/0)
ATO Responded
Output 60Hz frequency, you need to set parameters P0.06=60, P0.07=60, P0.19=60.
Do I need to do anything to end this program?
5
Farrah
Avatar
8/10/2023 3:21 AM
I inputted all the parameters, but I am not sure how to finish in order to test the system. I would think that when I program they would begin running at 25Hz. Can you tell me if I need to do something to end the programming?
Was this review helpful? Yes No (0/0)
ATO Responded
After setting the VFD parameters, you also need to use an external push button switch for the start signal and speed selection signal.
1. Please use a self-locking button switch to connect the FWD-COM terminal as the VFD start signal.
2. Please use a self-locking button switch to connect the X1-COM terminal as the VFD speed selection signal (when X1 and COM are connected, speed=60hz, disconnected=25HZ).
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

2 hp VFD, 1.5 kW, 1 phase 220-240V AC to three phase variable frequency drive, normal working temperature –10℃~ +40℃, sale by manufacturer directly.

Specification:

BasicsModelGK3000-2S0015
Capacity2 hp (1.5 kW)
Shipping weight2 kg
Dimension142*85*113 mm
I/O FeatureRated current7 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

1500W VFD Single Phase to Three Phase VFD Details

Tips: Variable Frequency Drive Wiring Specification Standard
Signal line and power line must be separated: When using analog signals for remote control of the VFD, in order to reduce interference, the signal line and strong circuit (main circuit and sequential circuit) should be separated, and the distance should be above 30cm. Even in the control cabinet, the wiring specification should be maintained. The maximum length of the control circuit between the signal and the VFD should not exceed 50m.
Signal lines and power lines must be placed in different metal conduits or metal hose: If the PLC and the VFD signal line are not placed in metal conduit, it will be easily affected by the external interference and VFD. For there is no built-in reactor, the VFD input and output power line will have a strong interference on the outside, so the metal conduit or metal hose must be extended to the VFD control terminal to ensure that the signal line thoroughly separate from the power line.

  1. Analog control signal line should be used double stranded shielded wire, wire size 0.75mm2. In the wiring must note that the cable stripping should be as short as possible (5-7mm). The stripped shield layer should be wrapped with insulating tape to prevent introduce interference from shielded cable and other equipment.
  2. In order to improve the wiring simplicity and reliability, the signal line using pressure wire rod terminal is recommended.
Product reviews
How do I connect my motor to the VFD?
5
Osman
Avatar
5/10/2018 7:32 PM
I received this 2hp VFD today in perfect condition.  So, thank you for the fast delivery.

I do however have one question that the very informative user manual doesn't seem to cover.  
How do I connect my motor to the VFD? The motor will be used to drive a fan for a kitchen exhaust and is quite oversized to deliver enough suction when running derated on low rpm / low torque.
If you would be so kind to enlighten me on this matter, it would be greatly appreciated.
Was this review helpful? Yes No (0/0)
ATO Responded
Connect your single phase supply to VFD's R&S terminals and connect your motor to U&V&W terminals.
E is ground terminal.
PA.01Motor rated voltage
5
Vincent
Avatar
1/11/2020 9:02 AM
is PA.01Motor rated voltage your line voltage?
I live in the EU can i put it on 380v on star confugiration? and on 220v in delta?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Input voltage To VFD should be 1-phase, 220/230V.
2. Your motor should be configured To 3-phase, Delta, 220V.
3. Set PA.01 To 220V.
A question for 2 hp VFD
5
nortin
Avatar
2/3/2023 12:31 AM
I just ordered 2hp VFD. I've read the manual, but I'm not seeing what size potentiometer I need for the external speed control.
Was this review helpful? Yes No (0/0)
ATO Responded
The VFD potentiometer is generally 4.7KΩ-10KΩ (for any VFD capacity).
Please refer to our demo video, see on: https://www.youtube.com/watch?v=TJsN1gW8hVQ&list=PLlo8RulDRnthBFbP4ydheukDSKw2hAfDn&index=11
Is it possible with the installation of a physical analog switch?
5
Paulo
Avatar
3/21/2023 7:11 PM
I need to be able to reverse the motor rotation using the keypad. Is that possible? Or is it possible with the installation of a physical analog switch? On my VFD, I have a FWD/REV switch on the panel. I've looked through the manual, but it does not have the F8-13=0 parameter to enable reverse rotation permission listed.
Was this review helpful? Yes No (0/0)
ATO Responded
If you want to operate forward and reverse through the VFD panel, you can set F7-01=2, press the MF.K key on the panel to switch between forward and reverse, reverse when the DIR light is on, and forward when it is off. But if you want the VFD to rotate forward by one key and reverse by the other key, you can only control it through the terminal.
How to set VFD?
5
lillian
Avatar
6/6/2023 11:57 PM
My client has an ATO GK3000 VFD installed at one of their sites in Texas, USA. (See attached pictures for make/model)
We have been unable to communicate with it via PLC hardwired controls. We want to use hardwired (terminal) signals for speed feedback, speed setpoint, forward run command, run feedback and trip feedback. We have also changed the following VFD parameters:
We need your support in setting this VFD up. Looking forward to your support.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry for the late response.
The PA parameter group does not need to be set, and the motor frequency and voltage are set to P0.07 and P0.08.
If the PLC can not communicate, you need to check the PLC program. The inverter communication protocol address is in chapter 9 of the inverter manual, page P160.
Please refer to the link for the manual: https://www.ato.com/Content/doc/ato-gk3000-series-vfd-user-manual.pdf
Do I need set parameters in VFD P0.0 and onwards?
5
gene
Avatar
6/7/2023 1:20 AM
Thank you for the response. I am trying to communicate via the hardwired signals and get information via MODBUS. In that case do I need to set any other parameters in P0.0 and onwards?
Was this review helpful? Yes No (0/0)
ATO Responded
No, you do not need to set any other parameters in P0.0 and onwards.
What the minimum voltage is that this VFD can function at?
5
trond
Avatar
7/24/2023 8:15 PM
Can you confirm what the minimum voltage is that this VFD can function at?
We measured our voltage at our 240V receptacle and it is outputting 204V.
Was this review helpful? Yes No (0/0)
ATO Responded
The minimum input voltage of GK3000-2S0015 is 150V, and the output voltage is 0-input voltage.
I need this VFD to output 60Hz
5
arkle
Avatar
7/24/2023 11:35 PM
I need it to output 60Hz, and the one we received appears to be rated at 220V 50Hz for its maximum output.
When I discussed this with the person on your website it was supposed to be rated for 230/240V 60Hz 3-phase output.
Was this review helpful? Yes No (0/0)
ATO Responded
Output 60Hz frequency, you need to set parameters P0.06=60, P0.07=60, P0.19=60.
Do I need to do anything to end this program?
5
Farrah
Avatar
8/10/2023 3:21 AM
I inputted all the parameters, but I am not sure how to finish in order to test the system. I would think that when I program they would begin running at 25Hz. Can you tell me if I need to do something to end the programming?
Was this review helpful? Yes No (0/0)
ATO Responded
After setting the VFD parameters, you also need to use an external push button switch for the start signal and speed selection signal.
1. Please use a self-locking button switch to connect the FWD-COM terminal as the VFD start signal.
2. Please use a self-locking button switch to connect the X1-COM terminal as the VFD speed selection signal (when X1 and COM are connected, speed=60hz, disconnected=25HZ).
Only registered users can write reviews
Customers who bought this item also bought

5 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0037
$294.31
5hp variable frequency drive, single phase to three phase VFD, 17 amps, RS485 enabled, shipping weight 4kg, manufacturer direct sale.

1 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0007
$159.32
1 hp VFD, convert single phase to three phase for AC motor speed controls, IP20, RS485 enabled, shipping weight 2kg, manufacturer direct sale.

3 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0022
$238.14
Low price 3hp VFD, convert 220V/230V/240V 1 phase to 3 phase, 9.6 amps, RS485 enabled, shipping weight 3kg, manufacturer direct sale.

1 hp (0.75 kW) VFD, Single Phase Input & Output

GK3000-1S0007
$195.82
Affordable 1 hp VFD, 1 phase for single phase AC induction motor, 220V - 240V 7 amps, manufacturer direct sale.

2 hp (1.5 kW) VFD, 3 Phase 240V, 415V, 480V

GK3000-4T0015G
$218.41
Cheap price 2 hp (1.5 kW) VFD, three phase 240V, 415V, 480V for choice, brand new sensorless vector variable frequency drive, RS485 enabled, strong overload capacity, manufacturer direct sale.