1 hp (0.75 kW) VFD, Single Phase Input & Output

$195.82
Affordable 1 hp VFD, 1 phase for single phase AC induction motor, 220V - 240V 7 amps, manufacturer direct sale.
SKU: GK3000-1S0007
Availability: In stock
Free Shipping
Delivery date: 2-3 days

1 hp variable frequency drive, 0.75 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.

Specification:

BasicsModelGK3000-1S0007
Capacity1 hp (0.75 kW)
Shipping weight2 kg
Dimension142*85*110 mm
I/O FeatureRated current7 A
Input voltagesingle phase AC 220V±15%
Input frequency47~63Hz
Output voltage0~rated input voltage
Output frequency0~1000Hz
Over load capacity150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
Control FeaturesControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Operation command modeKeypad control, Terminal control, Serial communication control
Frequency setting modeDigital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Start frequency0.40Hz~20.00Hz
Speed adjustment range1:50
Carrier frequency1.0-16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracyDigital setting: 0.01Hz
Analog setting: Maximum frequency * 0.05%
Torque boostAutomatically torque boost; manually torque boost: 0.1%~30.0%
V/f curveThree types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/deceleration modeStraight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s
Jog operationJog operation frequency: 0.0Hz~maximum frequency
Jog acceleration/deceleration time: 0.1s~3600.0s
Simple PLC & multi-step speed operationIt can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.
Built-in PIDBuilt-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulationKeep output voltage constant automatically when input voltage fluctuating
Control FunctionCommon DC busCommon DC bus for several VFDs, energy balanced automatically
Torque controlTorque control without PG
Torque limit"Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process
Wobble frequency controlMultiple triangular-wave frequency control, special for textile
Timing/length/counting controlTiming/length/counting control function
Over-voltage & over-current stall controlLimit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection functionUp to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function
Input/output terminalsInput terminalsProgrammable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI:
AI1: 0~10V or 0/4~20mA
A12: 0~10V or 0/4~20mA
Output terminals1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)
2 relay output
2 analog output: 0/4~20mA or 0~10V
Communication terminalsOffer RS485 communication interface, support MODBUS-RTU communication protocol
Human machine interfaceLED displayDisplay frequency setting, output frequency, output voltage, output current, etc.
Multifunction keyQUICK/JOG key, can be used as multifunction key
EnvironmentAmbient temperature-10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃).
Humidity90%RH or less (non-condensing)
Altitude≤1000M: Output rated power, >1000M: Output derated
Storage temperature-20℃~60℃

Note:

  1. The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
  2. ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
  3. Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
  4. If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.

Details

750W Single Phase VFD Details

Tips: Variable frequency drive applications

  1. Air conditioner load
    Office buildings, shopping malls, supermarkets and some factories have central air conditioner. In the summer electricity peak, large city air conditioner power consumption accounted for more than 40% of peak power. Therefore, using variable frequency drive to drag the air conditioning system, refrigeration pumps, cold water pumps and fans is a very good energy-saving technology.
  2. Crusher load
    Metallurgical mines and building material industry use a lot of crushers and grinding mills, these machineries have significant effect using variable frequency drive.
  3. Large furnace calciner furnace load
    Metallurgy, building materials, caustic soda and other large industrial rotary kiln uses DC motor, commutator motor, slip motor, cascade speed control and medium frequency unit speed control before. Because of these speed control mode or a slip ring have low efficiency, in recent years, many companies use frequency control, the effect is excellent.
  4. Compressor load
    Low-pressure compressors are widely used in various industrial sectors, high-pressure high-capacity compressors has more applications in steel, mining, fertilizer, ethylene industries. Using frequency control will bring low starting current, energy saving, optimizing equipment and other advantages.
  5. Rolling mill load
    The metallurgical industry uses AC-DC-AC VFD, and the multi-rack aluminum rolling unit uses general-purpose VFD to meet the low-frequency load starting. The variable frequency drive has advantages of inter-rack synchronous operation, constant tension control, simple and reliable operation.
  6. Winding engine load
    Iron mill blast furnace hoist equipment requires smooth boot and brake, balance speed adjusting and high reliability. These machineries use cascade, DC or rotor string resistance speed mode with low efficiency and poor reliability before. But, using VFD instead of the old speed control mode can achieve the desired results.
  7. Revolving furnace load
    Using AC variable frequency drive to replace DC unit in revolving furnace will get simple, reliable and stable operation.
  8. Roller load
    Roller load is mostly used in the iron and steel metallurgy industry. Using AC motor frequency control can improve equipment reliability and stability.

Running a single phase motor with VFD

In this video, ATO will show you details about running a single phase motor on a VFD. It's important to note that there are two wiring methods for single phase motor connecting to ATO single phase VFD: wiring of removing motor capacitor & wiring of keeping motor capacitor. At first, you should choose the wiring method you needed, and then set basic parameters step by step.

Four Ways to Control VFD with PLC

This video introduces the main wiring methods between PLC and VFD, including digital control, analog control, serial communication and Ethernet connection. The choice of connection method depends on the specific application requirements, system complexity, cost considerations and the need for control accuracy and flexibility.

How to Choose a VFD for Your Motor?

In this video, we lay out a list of key factors that should guide you in choosing the right VFD for your motor or any other possible application.

VFD analog input 0-10V frequency control (VI port)

Single-phase Output VFD Controls Single-phase Motor Speed

This video shows the details of using a frequency converter to run a single-phase motor on a single-phase power supply. Including wiring, parameter setting, single-phase motor speed control, etc.

Product reviews
1hp single-phase variable frequency drive can run multiple motors at the same time
5
Ashley
Avatar
3/2/2021 2:26 AM
I am interested in 1hp single phase output VFD. I have one questions about it. Can we control your single phase VFD through Modbus?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can control the variable frequency drive through Modbus.
Great controllers
5
Alec
Avatar
3/12/2021 7:59 PM
These are awesome controllers and really server for multiple purposes. I use these for controlling large fans in different sizes that exhaust hot air from a crypto mining farm.
Was this review helpful? Yes No (0/0)
1 hp VFD function
5
Philip
Avatar
4/28/2021 9:41 PM
We have a boat we are working on that has a 50Hz 230V distribution. The boat purchased a 60Hz 230V fresh water motor pump and I want to have the VFD set to output at 230V 60Hz with a 230V 50Hz supply, can your 1-phase VFD do that?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the VFD outputs 230V, 60Hz with 230V, 50Hz supply.
1hp VFD start frequency
5
Greene
Avatar
8/11/2021 3:14 AM
We want to start your 1 phase, 1hp VFD at 40Hz, can we do that?
Was this review helpful? Yes No (0/0)
ATO Responded
No, the VFD cannot be directly started from 40Hz, and if the minimum frequency of VFD is run from 40Hz, the motor current will be very high (Equivalent to 5-8 times rated current) and this is similar to running the motor from the mains grid.
Questions about 1 hp VFD
5
Sprice
Avatar
8/19/2021 3:27 AM
We want to start your 1-phase, 1hp VFD at 40Hz. Can we do that?
Was this review helpful? Yes No (0/0)
ATO Responded
No, the VFD cannot be directly started from 40Hz, and if the minimum frequency of VFD is run from 40Hz, the motor current will be very high. (Equivalent to 5-8 times rated current) and this is similar to running the motor from the main grid.
Can you provide the VFD I need?
5
Bernadette
Avatar
1/16/2022 11:51 PM
Can you provide 1 phase 220~240V to 3 phase AC 0~input voltage but with 60HP power capacity?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can.
Gate opener
5
Alain
Avatar
2/4/2022 9:10 AM
Can i use to control a Gate opener , i need to reduce the startup current

1HP
230V
60HZ
FLA 7 A
Eff-70
PF-76
Was this review helpful? Yes No (0/0)
ATO Responded
We need to know your motor nameplate to recommend a suitable VFD for you. You can send the motor nameplate to our email support@ato.com.
About VFD parameter
5
Abys
Avatar
5/27/2022 12:21 AM
I purchase this single phase VFD for running a single phase pump. I face an issue where the current applied to the pump is higher than the rated current we set in the GK3000 and some in a while drop to almost zero value. Do you have any recommendation of which parameter of the VFD need to be changed to avoid that?
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend that you can set the VFD parameters P0.02=2 or 3, P5.04=200, and test again.
sleep option
5
Luis
Avatar
6/17/2022 7:42 PM
Does this VFD have the option to sleep once it reaches the set point?
I want to use it for a constant water pumping system
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it does. Please refer to our YouTube example video: https://www.youtube.com/watch?v=OKR4tX4x0qQ&t=159s
We purchased this 1hp VFD drive a couple of years back. I have a couple of questions related to that.
5
Bob
Avatar
12/12/2022 8:54 PM
1. What is 1 in 1S007? In the manual, I only see 2 and 4.
2. Also, can I use it for controlling the fan motor?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The 1 in 1S007 means that the VFD is 1 Phase input/1 Phase output, and 2S means that the VFD is a single-phase input, three-phase output version.
2. Yes, you can also use it to control the fan motor. If your fan motor is a three-phase 230V motor, then that works too. But note that the rated current of the motor should be lower than the rated current of the VFD output.
Frequency question
5
Marrissa
Avatar
12/12/2022 11:47 PM
I am powering the VFD with 208V 1Phase, 60 Hz and I am drawing 208V 3 Phase to run the motor. I want to know how low can I go on the frequency front.
In addition, will the VFD change to variable torque for the fan application or will it change the power linearly with respect to the speed of the motor while maintaining the torque constant?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can run a 208V 3 Phase motor by powering the VFD with 208V 1Phase, 60 Hz. The VFD will change the power linearly with respect to the speed of motor while maintaining the torque constant, and it can output frequencies as low as 0.5Hz.
Instructions of VFD voltage adjustment
5
carver
Avatar
3/2/2023 1:24 AM
Hello, the electrician installed the used unit you sold me with the new digital operator. Also connected to my machine. He set the parameters that he is familiar with and your booklet.
Unfortunately… back to the very same question I asked you from the beginning, voltage!!!. You said it’s adjustable but did not give me any instructions. Electrician has disconnected my machine and told me he will return after I ask you about the voltage instructions hat I can show him the email. I have 240V single phase, 60hz input. Out put single phase, 50hz exactly what we want but 273V is our output. It must be 220V. Please help. Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
You can adjust the output voltage by setting the output voltage parameter p0.08 = 220V of the VFD.
If the output voltage is still high after setting p0.08 = 220, please set p0.08 = 210V, and test again.
For VFD's voltage and frequency settings, please refer to the quick setting document list description of the attachment.
Do I need to buy a separate 24 volt power supply?
5
Parker
Avatar
3/3/2023 12:04 AM
I thought the vfd would supply the 24 volt power needed. Do I need to buy a separate 24 volt power supply?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the 24V voltage of the pressure sensor can directly use the 24V voltage output on the VFD terminal (P24 terminal, GND).
The right VFD
5
Maisara
Avatar
5/23/2023 9:49 AM
Hi,
I was wondering if I can use this VFD to drive my drill press 750w permanent split capacitor motor.
I have no idea about how I should connect the motor, my main concern is to control the speed of the motor with keeping the torque. Also, I was wondering if it is possible to control the rotation of the motor and adding external switches and potentiometers. Thank you
Was this review helpful? Yes No (0/0)
ATO Responded
Single-phase VFDs have a small starting torque when controlling single-phase motors. If you want constant torque or high torque starting and speed regulation operation, ATO suggests you replace your single-phase (split-phase) motor with a three-phase motor. Also, the current and power rating of the VFD must be greater than or equal to the current and power rating of the motor.
Can the VFD work with a compressor?
5
Hollye
Avatar
8/7/2023 8:22 PM
I bought a VFD last week. Now I have a question. Can the VFD work with a compressor?
Was this review helpful? Yes No (0/0)
ATO Responded
Our VFD can only be connected to an asynchronous motor and can not be used as a power supply. If there is an asynchronous motor in your compressor, please provide us with the nameplate diagram of the motor for further confirmation.
220 To 110VAC single fase
5
JORGE
Avatar
10/18/2023 1:59 PM
it is possible to connect the VDF input 220 single phase  to   motor  110VAC 1 HP
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, but please note that the output voltage parameter should be limited to 110V before use.
What happens to the VFD?
5
Blake
Avatar
1/8/2024 1:09 AM
I connected and ran the VFD as per your instructions. However, when I checked the frequency on 3 phases, one phase seemed broken. One phase reads 60 Hz at zero load and the other phase reads more than 1 kHz in my multimeter.  

Measured Frequency: at zero load when VFD running at minimum speed (zero)
(U & V) = 60Hz
(U & W) = 1.6 kHz
(V & W) = 1.6 kHz

What happens to the VFD? Do you have any idea how to troubleshoot this issue?
Was this review helpful? Yes No (0/0)
ATO Responded
It is inaccurate to use a multimeter to measure VFD output frequency and voltage. You can run the VFD without loading first. Please check whether the operating frequency on the panel can reach 60HZ.
Then please use a multimeter to measure whether the voltages at the output terminals U, V, and W are normal. If the output voltage deviation is not large, you can connect the motor. Please run the motor without load to see if the motor can run normally.
Single Phase Input
5
Blake
Avatar
1/8/2024 7:20 PM
I have a 0007 Vfd and need to know the wiring for a single PH motor 220v input
Was this review helpful? Yes No (0/0)
ATO Responded
The VFD input terminal is connected to R, S terminals or L, N terminals.  Please refer to this document: https://www.ato.com/Content/doc/gk3000-series-vfd-quick-set-user-manual.pdf
I have a new VFD,but I have a problem.
5
Benjamin
Avatar
1/8/2024 8:13 PM
I have installed a single-phase 220 v .75KW spindle according to the instructions in the manual. In an unloaded condition, the motor will not start smoothly and run.  there is tremendous vibration on startup and shutdown, and the drive goes into error mode, requiring a reset to recover.
Was this review helpful? Yes No (0/0)
ATO Responded
We think it may be that the frequency parameters of your VFD are Not set properly. You need to set the parameters: P0.02=motor rated frequency, P0.05=motor rated frequency, P0.06=motor rated frequency.
I’ve just installed a VFD
5
Grayson
Avatar
1/9/2024 6:46 PM
I’ve just installed a VFD with a 1/2hp asynchronous 110/220V motor. It is wired for 220v. It has a single centrifugal switched start capacitor. The capacitor has been removed. All VFD's settings are default. When starting the speed only goes up to about 1/4 of rated rpm and will not go higher. The current in the start wiring is high (7-9A). Disconnecting the start winding (after allowing the motor to start running) allows the motor/VFD to run normally.
Was this review helpful? Yes No (0/0)
ATO Responded
1. We do not recommend removing the motor capacitor, please refer to the attached wiring diagram for wiring.
Please refer to the manual: https://www.ato.com/Content/doc/ato-gk3000-single-phase-vfd-user-manual.pdf

2. The speed of the motor cannot reach the rated value, maybe the frequency is not set properly. We recommend setting the frequency: P0.02=rated frequency, P0.05=rated frequency, P0.06=rated frequency.
Please refer to the quick set manual: https://www.ato.com/Content/doc/gk3000-series-vfd-quick-set-user-manual.pdf
Please refer to the setting video: https://youtu.be/jiVpJAY84MQ
Please recommend the proper VFD
5
Darren
Avatar
2/5/2024 12:57 AM
Please recommend the proper VFD that will provide 1ph 230v input to 1ph 230-volt output, 60hz with 10amp capacity.
Was this review helpful? Yes No (0/0)
ATO Responded
The VFD will provide 1ph 230v input to 1ph 230-volt output, 60hz, but the rated output current is only 7A and cannot reach 10A.  If you want the VFD to output more than 10A, you need to buy a 3HP capacity version.
I have a question
5
Aubren
Avatar
7/12/2024 3:18 AM
I think the motor VFD combination should remove the capacitor and cover the wires, right? Please advise, thank you for your help.
Was this review helpful? Yes No (0/0)
ATO Responded
The motor VFD combination does not require the removal of the capacitor of the single-phase motor. You can connect the 2 cables of the single-phase motor directly to the VFD output terminals U, W (the V terminal is floating), and connect the single-phase power supply 220V to the input terminals L, N. If you have any other questions, please feel free to contact us.
Some questions
4
Maeve
Avatar
7/24/2024 7:34 PM
Is it possible to configure my GK3000-1S0007 so as to execute FWD upon power up? Also, is there a way to have the up/down buttons set the frequency instead of the potentiometer?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Yes, enable "external terminal control", then short-connect X1 and COM, your VFD will start to run as.
2. Yes, set P0.01=1, and when not running, long press the "△" or "▽" button so the value of P0.02 (setting running frequency) will change.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

1 hp variable frequency drive, 0.75 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.

Specification:

BasicsModelGK3000-1S0007
Capacity1 hp (0.75 kW)
Shipping weight2 kg
Dimension142*85*110 mm
I/O FeatureRated current7 A
Input voltagesingle phase AC 220V±15%
Input frequency47~63Hz
Output voltage0~rated input voltage
Output frequency0~1000Hz
Over load capacity150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s
Control FeaturesControl modeV/F, Sensorless vector control (SVC), Speed sensor vector control (FVC)
Operation command modeKeypad control, Terminal control, Serial communication control
Frequency setting modeDigital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes.
Start frequency0.40Hz~20.00Hz
Speed adjustment range1:50
Carrier frequency1.0-16.0kHz, automatically adjusted according to temperature and load characteristics
Frequency accuracyDigital setting: 0.01Hz
Analog setting: Maximum frequency * 0.05%
Torque boostAutomatically torque boost; manually torque boost: 0.1%~30.0%
V/f curveThree types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square)
Acceleration/deceleration modeStraight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s
Jog operationJog operation frequency: 0.0Hz~maximum frequency
Jog acceleration/deceleration time: 0.1s~3600.0s
Simple PLC & multi-step speed operationIt can realize a maximum of 16 segments speed running via the built-in PLC or control terminal.
Built-in PIDBuilt-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.)
Automatic voltage regulationKeep output voltage constant automatically when input voltage fluctuating
Control FunctionCommon DC busCommon DC bus for several VFDs, energy balanced automatically
Torque controlTorque control without PG
Torque limit"Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process
Wobble frequency controlMultiple triangular-wave frequency control, special for textile
Timing/length/counting controlTiming/length/counting control function
Over-voltage & over-current stall controlLimit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping
Fault protection functionUp to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function
Input/output terminalsInput terminalsProgrammable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI:
AI1: 0~10V or 0/4~20mA
A12: 0~10V or 0/4~20mA
Output terminals1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output)
2 relay output
2 analog output: 0/4~20mA or 0~10V
Communication terminalsOffer RS485 communication interface, support MODBUS-RTU communication protocol
Human machine interfaceLED displayDisplay frequency setting, output frequency, output voltage, output current, etc.
Multifunction keyQUICK/JOG key, can be used as multifunction key
EnvironmentAmbient temperature-10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃).
Humidity90%RH or less (non-condensing)
Altitude≤1000M: Output rated power, >1000M: Output derated
Storage temperature-20℃~60℃

Note:

  1. The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
  2. ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
  3. Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
  4. If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.

Details

750W Single Phase VFD Details

Tips: Variable frequency drive applications

  1. Air conditioner load
    Office buildings, shopping malls, supermarkets and some factories have central air conditioner. In the summer electricity peak, large city air conditioner power consumption accounted for more than 40% of peak power. Therefore, using variable frequency drive to drag the air conditioning system, refrigeration pumps, cold water pumps and fans is a very good energy-saving technology.
  2. Crusher load
    Metallurgical mines and building material industry use a lot of crushers and grinding mills, these machineries have significant effect using variable frequency drive.
  3. Large furnace calciner furnace load
    Metallurgy, building materials, caustic soda and other large industrial rotary kiln uses DC motor, commutator motor, slip motor, cascade speed control and medium frequency unit speed control before. Because of these speed control mode or a slip ring have low efficiency, in recent years, many companies use frequency control, the effect is excellent.
  4. Compressor load
    Low-pressure compressors are widely used in various industrial sectors, high-pressure high-capacity compressors has more applications in steel, mining, fertilizer, ethylene industries. Using frequency control will bring low starting current, energy saving, optimizing equipment and other advantages.
  5. Rolling mill load
    The metallurgical industry uses AC-DC-AC VFD, and the multi-rack aluminum rolling unit uses general-purpose VFD to meet the low-frequency load starting. The variable frequency drive has advantages of inter-rack synchronous operation, constant tension control, simple and reliable operation.
  6. Winding engine load
    Iron mill blast furnace hoist equipment requires smooth boot and brake, balance speed adjusting and high reliability. These machineries use cascade, DC or rotor string resistance speed mode with low efficiency and poor reliability before. But, using VFD instead of the old speed control mode can achieve the desired results.
  7. Revolving furnace load
    Using AC variable frequency drive to replace DC unit in revolving furnace will get simple, reliable and stable operation.
  8. Roller load
    Roller load is mostly used in the iron and steel metallurgy industry. Using AC motor frequency control can improve equipment reliability and stability.
Product reviews
1hp single-phase variable frequency drive can run multiple motors at the same time
5
Ashley
Avatar
3/2/2021 2:26 AM
I am interested in 1hp single phase output VFD. I have one questions about it. Can we control your single phase VFD through Modbus?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can control the variable frequency drive through Modbus.
Great controllers
5
Alec
Avatar
3/12/2021 7:59 PM
These are awesome controllers and really server for multiple purposes. I use these for controlling large fans in different sizes that exhaust hot air from a crypto mining farm.
Was this review helpful? Yes No (0/0)
1 hp VFD function
5
Philip
Avatar
4/28/2021 9:41 PM
We have a boat we are working on that has a 50Hz 230V distribution. The boat purchased a 60Hz 230V fresh water motor pump and I want to have the VFD set to output at 230V 60Hz with a 230V 50Hz supply, can your 1-phase VFD do that?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the VFD outputs 230V, 60Hz with 230V, 50Hz supply.
1hp VFD start frequency
5
Greene
Avatar
8/11/2021 3:14 AM
We want to start your 1 phase, 1hp VFD at 40Hz, can we do that?
Was this review helpful? Yes No (0/0)
ATO Responded
No, the VFD cannot be directly started from 40Hz, and if the minimum frequency of VFD is run from 40Hz, the motor current will be very high (Equivalent to 5-8 times rated current) and this is similar to running the motor from the mains grid.
Questions about 1 hp VFD
5
Sprice
Avatar
8/19/2021 3:27 AM
We want to start your 1-phase, 1hp VFD at 40Hz. Can we do that?
Was this review helpful? Yes No (0/0)
ATO Responded
No, the VFD cannot be directly started from 40Hz, and if the minimum frequency of VFD is run from 40Hz, the motor current will be very high. (Equivalent to 5-8 times rated current) and this is similar to running the motor from the main grid.
Can you provide the VFD I need?
5
Bernadette
Avatar
1/16/2022 11:51 PM
Can you provide 1 phase 220~240V to 3 phase AC 0~input voltage but with 60HP power capacity?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can.
Gate opener
5
Alain
Avatar
2/4/2022 9:10 AM
Can i use to control a Gate opener , i need to reduce the startup current

1HP
230V
60HZ
FLA 7 A
Eff-70
PF-76
Was this review helpful? Yes No (0/0)
ATO Responded
We need to know your motor nameplate to recommend a suitable VFD for you. You can send the motor nameplate to our email support@ato.com.
About VFD parameter
5
Abys
Avatar
5/27/2022 12:21 AM
I purchase this single phase VFD for running a single phase pump. I face an issue where the current applied to the pump is higher than the rated current we set in the GK3000 and some in a while drop to almost zero value. Do you have any recommendation of which parameter of the VFD need to be changed to avoid that?
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend that you can set the VFD parameters P0.02=2 or 3, P5.04=200, and test again.
sleep option
5
Luis
Avatar
6/17/2022 7:42 PM
Does this VFD have the option to sleep once it reaches the set point?
I want to use it for a constant water pumping system
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it does. Please refer to our YouTube example video: https://www.youtube.com/watch?v=OKR4tX4x0qQ&t=159s
We purchased this 1hp VFD drive a couple of years back. I have a couple of questions related to that.
5
Bob
Avatar
12/12/2022 8:54 PM
1. What is 1 in 1S007? In the manual, I only see 2 and 4.
2. Also, can I use it for controlling the fan motor?
Was this review helpful? Yes No (0/0)
ATO Responded
1. The 1 in 1S007 means that the VFD is 1 Phase input/1 Phase output, and 2S means that the VFD is a single-phase input, three-phase output version.
2. Yes, you can also use it to control the fan motor. If your fan motor is a three-phase 230V motor, then that works too. But note that the rated current of the motor should be lower than the rated current of the VFD output.
Frequency question
5
Marrissa
Avatar
12/12/2022 11:47 PM
I am powering the VFD with 208V 1Phase, 60 Hz and I am drawing 208V 3 Phase to run the motor. I want to know how low can I go on the frequency front.
In addition, will the VFD change to variable torque for the fan application or will it change the power linearly with respect to the speed of the motor while maintaining the torque constant?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can run a 208V 3 Phase motor by powering the VFD with 208V 1Phase, 60 Hz. The VFD will change the power linearly with respect to the speed of motor while maintaining the torque constant, and it can output frequencies as low as 0.5Hz.
Instructions of VFD voltage adjustment
5
carver
Avatar
3/2/2023 1:24 AM
Hello, the electrician installed the used unit you sold me with the new digital operator. Also connected to my machine. He set the parameters that he is familiar with and your booklet.
Unfortunately… back to the very same question I asked you from the beginning, voltage!!!. You said it’s adjustable but did not give me any instructions. Electrician has disconnected my machine and told me he will return after I ask you about the voltage instructions hat I can show him the email. I have 240V single phase, 60hz input. Out put single phase, 50hz exactly what we want but 273V is our output. It must be 220V. Please help. Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
You can adjust the output voltage by setting the output voltage parameter p0.08 = 220V of the VFD.
If the output voltage is still high after setting p0.08 = 220, please set p0.08 = 210V, and test again.
For VFD's voltage and frequency settings, please refer to the quick setting document list description of the attachment.
Do I need to buy a separate 24 volt power supply?
5
Parker
Avatar
3/3/2023 12:04 AM
I thought the vfd would supply the 24 volt power needed. Do I need to buy a separate 24 volt power supply?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, the 24V voltage of the pressure sensor can directly use the 24V voltage output on the VFD terminal (P24 terminal, GND).
The right VFD
5
Maisara
Avatar
5/23/2023 9:49 AM
Hi,
I was wondering if I can use this VFD to drive my drill press 750w permanent split capacitor motor.
I have no idea about how I should connect the motor, my main concern is to control the speed of the motor with keeping the torque. Also, I was wondering if it is possible to control the rotation of the motor and adding external switches and potentiometers. Thank you
Was this review helpful? Yes No (0/0)
ATO Responded
Single-phase VFDs have a small starting torque when controlling single-phase motors. If you want constant torque or high torque starting and speed regulation operation, ATO suggests you replace your single-phase (split-phase) motor with a three-phase motor. Also, the current and power rating of the VFD must be greater than or equal to the current and power rating of the motor.
Can the VFD work with a compressor?
5
Hollye
Avatar
8/7/2023 8:22 PM
I bought a VFD last week. Now I have a question. Can the VFD work with a compressor?
Was this review helpful? Yes No (0/0)
ATO Responded
Our VFD can only be connected to an asynchronous motor and can not be used as a power supply. If there is an asynchronous motor in your compressor, please provide us with the nameplate diagram of the motor for further confirmation.
220 To 110VAC single fase
5
JORGE
Avatar
10/18/2023 1:59 PM
it is possible to connect the VDF input 220 single phase  to   motor  110VAC 1 HP
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, but please note that the output voltage parameter should be limited to 110V before use.
What happens to the VFD?
5
Blake
Avatar
1/8/2024 1:09 AM
I connected and ran the VFD as per your instructions. However, when I checked the frequency on 3 phases, one phase seemed broken. One phase reads 60 Hz at zero load and the other phase reads more than 1 kHz in my multimeter.  

Measured Frequency: at zero load when VFD running at minimum speed (zero)
(U & V) = 60Hz
(U & W) = 1.6 kHz
(V & W) = 1.6 kHz

What happens to the VFD? Do you have any idea how to troubleshoot this issue?
Was this review helpful? Yes No (0/0)
ATO Responded
It is inaccurate to use a multimeter to measure VFD output frequency and voltage. You can run the VFD without loading first. Please check whether the operating frequency on the panel can reach 60HZ.
Then please use a multimeter to measure whether the voltages at the output terminals U, V, and W are normal. If the output voltage deviation is not large, you can connect the motor. Please run the motor without load to see if the motor can run normally.
Single Phase Input
5
Blake
Avatar
1/8/2024 7:20 PM
I have a 0007 Vfd and need to know the wiring for a single PH motor 220v input
Was this review helpful? Yes No (0/0)
ATO Responded
The VFD input terminal is connected to R, S terminals or L, N terminals.  Please refer to this document: https://www.ato.com/Content/doc/gk3000-series-vfd-quick-set-user-manual.pdf
I have a new VFD,but I have a problem.
5
Benjamin
Avatar
1/8/2024 8:13 PM
I have installed a single-phase 220 v .75KW spindle according to the instructions in the manual. In an unloaded condition, the motor will not start smoothly and run.  there is tremendous vibration on startup and shutdown, and the drive goes into error mode, requiring a reset to recover.
Was this review helpful? Yes No (0/0)
ATO Responded
We think it may be that the frequency parameters of your VFD are Not set properly. You need to set the parameters: P0.02=motor rated frequency, P0.05=motor rated frequency, P0.06=motor rated frequency.
I’ve just installed a VFD
5
Grayson
Avatar
1/9/2024 6:46 PM
I’ve just installed a VFD with a 1/2hp asynchronous 110/220V motor. It is wired for 220v. It has a single centrifugal switched start capacitor. The capacitor has been removed. All VFD's settings are default. When starting the speed only goes up to about 1/4 of rated rpm and will not go higher. The current in the start wiring is high (7-9A). Disconnecting the start winding (after allowing the motor to start running) allows the motor/VFD to run normally.
Was this review helpful? Yes No (0/0)
ATO Responded
1. We do not recommend removing the motor capacitor, please refer to the attached wiring diagram for wiring.
Please refer to the manual: https://www.ato.com/Content/doc/ato-gk3000-single-phase-vfd-user-manual.pdf

2. The speed of the motor cannot reach the rated value, maybe the frequency is not set properly. We recommend setting the frequency: P0.02=rated frequency, P0.05=rated frequency, P0.06=rated frequency.
Please refer to the quick set manual: https://www.ato.com/Content/doc/gk3000-series-vfd-quick-set-user-manual.pdf
Please refer to the setting video: https://youtu.be/jiVpJAY84MQ
Please recommend the proper VFD
5
Darren
Avatar
2/5/2024 12:57 AM
Please recommend the proper VFD that will provide 1ph 230v input to 1ph 230-volt output, 60hz with 10amp capacity.
Was this review helpful? Yes No (0/0)
ATO Responded
The VFD will provide 1ph 230v input to 1ph 230-volt output, 60hz, but the rated output current is only 7A and cannot reach 10A.  If you want the VFD to output more than 10A, you need to buy a 3HP capacity version.
I have a question
5
Aubren
Avatar
7/12/2024 3:18 AM
I think the motor VFD combination should remove the capacitor and cover the wires, right? Please advise, thank you for your help.
Was this review helpful? Yes No (0/0)
ATO Responded
The motor VFD combination does not require the removal of the capacitor of the single-phase motor. You can connect the 2 cables of the single-phase motor directly to the VFD output terminals U, W (the V terminal is floating), and connect the single-phase power supply 220V to the input terminals L, N. If you have any other questions, please feel free to contact us.
Some questions
4
Maeve
Avatar
7/24/2024 7:34 PM
Is it possible to configure my GK3000-1S0007 so as to execute FWD upon power up? Also, is there a way to have the up/down buttons set the frequency instead of the potentiometer?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Yes, enable "external terminal control", then short-connect X1 and COM, your VFD will start to run as.
2. Yes, set P0.01=1, and when not running, long press the "△" or "▽" button so the value of P0.02 (setting running frequency) will change.
Only registered users can write reviews
Customers who bought this item also bought

2 hp (1.5 kW) VFD, Single Phase Input & Output

GK3000-1S0015
$243.08
Discounted 2 hp VFD, 1 phase for single phase AC motor, 220V - 240V 9.6 amps, brand new direct sale by manufacturer.

2 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0015
$183.16
2 hp VFD, convert single phase to three phase for AC motor speed controls, 7 amps, IP20, RS485 enabled, manufacturer direct sale.

1/2 hp (0.4 kW) VFD, Single Phase Input & Output

GK3000-1S0004
$162.46
Inexpensive 1/2 hp VFD, 1 phase for single phase AC motor speed controls, 220V - 240V 4 amps, manufacturer direct sale.

5 hp (3.7 kW) VFD, 3 Phase 230V, 400V, 480V

GK3000-4T0037G
$293.51
Favorable price 5 hp (3.7 / 4 kW) VFD, three phase 230V, 400V, 480V, high performance vector variable frequency drive, IP20 enclosure, RS485 enabled, brand new direct sale by manufacturer.

1 hp (0.75 kW) VFD, 3 Phase 230V, 400V, 480V

GK3000-4T0007G
$206.49
Favorable price 1 hp (0.75 kW) VFD, three phase 230V/400V/480V 50Hz/60Hz for selection, sensorless vector variable frequency drive, RS485 enabled, strong overload capacity, manufacturer direct sale.