1 hp variable frequency drive, 0.75 kW, 1 phase 220V - 240V for single phase AC motor, manufacturer direct sale.
Specification:
| Basics | Model | GK3000-1S0007 |
| Capacity | 1 hp (0.75 kW) | |
| Shipping weight | 2 kg | |
| Dimension | 142*85*110 mm | |
| I/O Feature | Rated current | 7 A |
| Input voltage | single phase AC 220V±15% | |
| Input frequency | 47~63Hz | |
| Output voltage | 0~rated input voltage | |
| Output frequency | 0~1000Hz | |
| Over load capacity | 150% of rated current for 60s, 180% of rated current for 10s, 200% of rated current for 3s | |
| Control Features | Control mode | V/F, Sensorless vector control (SVC), Speed sensor vector control (FVC) |
| Operation command mode | Keypad control, Terminal control, Serial communication control | |
| Frequency setting mode | Digital setting, analog setting, pulse frequency setting, serial communication setting, multi-step speed setting & simple PLC, PID setting, etc. These frequency settings can be combined & switched in various modes. | |
| Start frequency | 0.40Hz~20.00Hz | |
| Speed adjustment range | 1:50 | |
| Carrier frequency | 1.0-16.0kHz, automatically adjusted according to temperature and load characteristics | |
| Frequency accuracy | Digital setting: 0.01Hz Analog setting: Maximum frequency * 0.05% | |
| Torque boost | Automatically torque boost; manually torque boost: 0.1%~30.0% | |
| V/f curve | Three types: linear, multiple point and square type (1.2 power, 1.4 power, 1.6 power, 1.8 power, square) | |
| Acceleration/deceleration mode | Straight line/S curve; four kinds of acceleration/deceleration time, range: 0.1s~3600.0s | |
| Jog operation | Jog operation frequency: 0.0Hz~maximum frequency Jog acceleration/deceleration time: 0.1s~3600.0s | |
| Simple PLC & multi-step speed operation | It can realize a maximum of 16 segments speed running via the built-in PLC or control terminal. | |
| Built-in PID | Built-in PID control to easily realize the close loop control of the process parameters (such as pressure, temperature, flow, etc.) | |
| Automatic voltage regulation | Keep output voltage constant automatically when input voltage fluctuating | |
| Control Function | Common DC bus | Common DC bus for several VFDs, energy balanced automatically |
| Torque control | Torque control without PG | |
| Torque limit | "Rooter" characteristics, limit the torque automatically and prevent frequent over-current tripping during the running process | |
| Wobble frequency control | Multiple triangular-wave frequency control, special for textile | |
| Timing/length/counting control | Timing/length/counting control function | |
| Over-voltage & over-current stall control | Limit current & voltage automatically during the running process, prevent frequent over-current & over-voltage tripping | |
| Fault protection function | Up to 30 fault protections including over-current, over-voltage, under-voltage, overheating, default phase, overload, shortcut, etc., can record the detailed running status during failure & has fault automatic reset function | |
| Input/output terminals | Input terminals | Programmable DI: 7 on-off inputs, 1 high-speed pulse input 2 programmable AI: AI1: 0~10V or 0/4~20mA A12: 0~10V or 0/4~20mA |
| Output terminals | 1 programmable open collector output: 1 analog output (open collector output or high-speed pulse output) 2 relay output 2 analog output: 0/4~20mA or 0~10V | |
| Communication terminals | Offer RS485 communication interface, support MODBUS-RTU communication protocol | |
| Human machine interface | LED display | Display frequency setting, output frequency, output voltage, output current, etc. |
| Multifunction key | QUICK/JOG key, can be used as multifunction key | |
| Environment | Ambient temperature | -10℃~40℃, derated 4% when the temperature rise by every 1℃ (40℃~50℃). |
| Humidity | 90%RH or less (non-condensing) | |
| Altitude | ≤1000M: Output rated power, >1000M: Output derated | |
| Storage temperature | -20℃~60℃ |
Note:
- The single phase motor should Not be adjusted to run based on a lower frequency than 80% of its rated frequency for along time, otherwise the motor may fail.
- ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
- Single phase VFD Cannot control the motor in reverse, if you want to reverse the motor, refer to the motor nameplate instructions for operation.
- If you have restored the factory settings, please ensure that the phase loss protection has been disabled. PA.13=0.
Details

Tips: Variable frequency drive applications
- Air conditioner load
Office buildings, shopping malls, supermarkets and some factories have central air conditioner. In the summer electricity peak, large city air conditioner power consumption accounted for more than 40% of peak power. Therefore, using variable frequency drive to drag the air conditioning system, refrigeration pumps, cold water pumps and fans is a very good energy-saving technology. - Crusher load
Metallurgical mines and building material industry use a lot of crushers and grinding mills, these machineries have significant effect using variable frequency drive. - Large furnace calciner furnace load
Metallurgy, building materials, caustic soda and other large industrial rotary kiln uses DC motor, commutator motor, slip motor, cascade speed control and medium frequency unit speed control before. Because of these speed control mode or a slip ring have low efficiency, in recent years, many companies use frequency control, the effect is excellent. - Compressor load
Low-pressure compressors are widely used in various industrial sectors, high-pressure high-capacity compressors has more applications in steel, mining, fertilizer, ethylene industries. Using frequency control will bring low starting current, energy saving, optimizing equipment and other advantages. - Rolling mill load
The metallurgical industry uses AC-DC-AC VFD, and the multi-rack aluminum rolling unit uses general-purpose VFD to meet the low-frequency load starting. The variable frequency drive has advantages of inter-rack synchronous operation, constant tension control, simple and reliable operation. - Winding engine load
Iron mill blast furnace hoist equipment requires smooth boot and brake, balance speed adjusting and high reliability. These machineries use cascade, DC or rotor string resistance speed mode with low efficiency and poor reliability before. But, using VFD instead of the old speed control mode can achieve the desired results. - Revolving furnace load
Using AC variable frequency drive to replace DC unit in revolving furnace will get simple, reliable and stable operation. - Roller load
Roller load is mostly used in the iron and steel metallurgy industry. Using AC motor frequency control can improve equipment reliability and stability.
Product reviews
1hp single-phase variable frequency drive can run multiple motors at the same time
Ashley
3/2/2021 2:26 AM
I am interested in 1hp single phase output VFD. I have one questions about it. Can we control your single phase VFD through Modbus?
Was this review helpful? (0/0)
Great controllers
Alec
3/12/2021 7:59 PM
These are awesome controllers and really server for multiple purposes. I use these for controlling large fans in different sizes that exhaust hot air from a crypto mining farm.
Was this review helpful? (0/0)
1 hp VFD function
Philip
4/28/2021 9:41 PM
We have a boat we are working on that has a 50Hz 230V distribution. The boat purchased a 60Hz 230V fresh water motor pump and I want to have the VFD set to output at 230V 60Hz with a 230V 50Hz supply, can your 1-phase VFD do that?
Was this review helpful? (0/0)
1hp VFD start frequency
Greene
8/11/2021 3:14 AM
We want to start your 1 phase, 1hp VFD at 40Hz, can we do that?
Was this review helpful? (0/0)
Questions about 1 hp VFD
Sprice
8/19/2021 3:27 AM
We want to start your 1-phase, 1hp VFD at 40Hz. Can we do that?
Was this review helpful? (0/0)
Can you provide the VFD I need?
Bernadette
1/16/2022 11:51 PM
Can you provide 1 phase 220~240V to 3 phase AC 0~input voltage but with 60HP power capacity?
Was this review helpful? (0/0)
Gate opener
Alain
2/4/2022 9:10 AM
Can i use to control a Gate opener , i need to reduce the startup current
1HP
230V
60HZ
FLA 7 A
Eff-70
PF-76
1HP
230V
60HZ
FLA 7 A
Eff-70
PF-76
Was this review helpful? (0/0)
About VFD parameter
Abys
5/27/2022 12:21 AM
I purchase this single phase VFD for running a single phase pump. I face an issue where the current applied to the pump is higher than the rated current we set in the GK3000 and some in a while drop to almost zero value. Do you have any recommendation of which parameter of the VFD need to be changed to avoid that?
Was this review helpful? (0/0)
sleep option
Luis
6/17/2022 7:42 PM
Does this VFD have the option to sleep once it reaches the set point?
I want to use it for a constant water pumping system
I want to use it for a constant water pumping system
Was this review helpful? (0/0)
We purchased this 1hp VFD drive a couple of years back. I have a couple of questions related to that.
Bob
12/12/2022 8:54 PM
1. What is 1 in 1S007? In the manual, I only see 2 and 4.
2. Also, can I use it for controlling the fan motor?
2. Also, can I use it for controlling the fan motor?
Was this review helpful? (0/0)
Frequency question
Marrissa
12/12/2022 11:47 PM
I am powering the VFD with 208V 1Phase, 60 Hz and I am drawing 208V 3 Phase to run the motor. I want to know how low can I go on the frequency front.
In addition, will the VFD change to variable torque for the fan application or will it change the power linearly with respect to the speed of the motor while maintaining the torque constant?
In addition, will the VFD change to variable torque for the fan application or will it change the power linearly with respect to the speed of the motor while maintaining the torque constant?
Was this review helpful? (0/0)
Instructions of VFD voltage adjustment
carver
3/2/2023 1:24 AM
Hello, the electrician installed the used unit you sold me with the new digital operator. Also connected to my machine. He set the parameters that he is familiar with and your booklet.
Unfortunately… back to the very same question I asked you from the beginning, voltage!!!. You said it’s adjustable but did not give me any instructions. Electrician has disconnected my machine and told me he will return after I ask you about the voltage instructions hat I can show him the email. I have 240V single phase, 60hz input. Out put single phase, 50hz exactly what we want but 273V is our output. It must be 220V. Please help. Thank you.
Unfortunately… back to the very same question I asked you from the beginning, voltage!!!. You said it’s adjustable but did not give me any instructions. Electrician has disconnected my machine and told me he will return after I ask you about the voltage instructions hat I can show him the email. I have 240V single phase, 60hz input. Out put single phase, 50hz exactly what we want but 273V is our output. It must be 220V. Please help. Thank you.
Was this review helpful? (0/0)
Do I need to buy a separate 24 volt power supply?
Parker
3/3/2023 12:04 AM
I thought the vfd would supply the 24 volt power needed. Do I need to buy a separate 24 volt power supply?
Was this review helpful? (0/0)
The right VFD
Maisara
5/23/2023 9:49 AM
Hi,
I was wondering if I can use this VFD to drive my drill press 750w permanent split capacitor motor.
I have no idea about how I should connect the motor, my main concern is to control the speed of the motor with keeping the torque. Also, I was wondering if it is possible to control the rotation of the motor and adding external switches and potentiometers. Thank you
I was wondering if I can use this VFD to drive my drill press 750w permanent split capacitor motor.
I have no idea about how I should connect the motor, my main concern is to control the speed of the motor with keeping the torque. Also, I was wondering if it is possible to control the rotation of the motor and adding external switches and potentiometers. Thank you
Was this review helpful? (0/0)
Can the VFD work with a compressor?
Hollye
8/7/2023 8:22 PM
I bought a VFD last week. Now I have a question. Can the VFD work with a compressor?
Was this review helpful? (0/0)
220 To 110VAC single fase
JORGE
10/18/2023 1:59 PM
it is possible to connect the VDF input 220 single phase to motor 110VAC 1 HP
Was this review helpful? (0/0)
What happens to the VFD?
Blake
1/8/2024 1:09 AM
I connected and ran the VFD as per your instructions. However, when I checked the frequency on 3 phases, one phase seemed broken. One phase reads 60 Hz at zero load and the other phase reads more than 1 kHz in my multimeter.
Measured Frequency: at zero load when VFD running at minimum speed (zero)
(U & V) = 60Hz
(U & W) = 1.6 kHz
(V & W) = 1.6 kHz
What happens to the VFD? Do you have any idea how to troubleshoot this issue?
Measured Frequency: at zero load when VFD running at minimum speed (zero)
(U & V) = 60Hz
(U & W) = 1.6 kHz
(V & W) = 1.6 kHz
What happens to the VFD? Do you have any idea how to troubleshoot this issue?
Was this review helpful? (0/0)
Single Phase Input
Blake
1/8/2024 7:20 PM
I have a 0007 Vfd and need to know the wiring for a single PH motor 220v input
Was this review helpful? (0/0)
I have a new VFD,but I have a problem.
Benjamin
1/8/2024 8:13 PM
I have installed a single-phase 220 v .75KW spindle according to the instructions in the manual. In an unloaded condition, the motor will not start smoothly and run. there is tremendous vibration on startup and shutdown, and the drive goes into error mode, requiring a reset to recover.
Was this review helpful? (0/0)
I’ve just installed a VFD
Grayson
1/9/2024 6:46 PM
I’ve just installed a VFD with a 1/2hp asynchronous 110/220V motor. It is wired for 220v. It has a single centrifugal switched start capacitor. The capacitor has been removed. All VFD's settings are default. When starting the speed only goes up to about 1/4 of rated rpm and will not go higher. The current in the start wiring is high (7-9A). Disconnecting the start winding (after allowing the motor to start running) allows the motor/VFD to run normally.
Was this review helpful? (0/0)
Please recommend the proper VFD
Darren
2/5/2024 12:57 AM
Please recommend the proper VFD that will provide 1ph 230v input to 1ph 230-volt output, 60hz with 10amp capacity.
Was this review helpful? (0/0)
I have a question
Aubren
7/12/2024 3:18 AM
I think the motor VFD combination should remove the capacitor and cover the wires, right? Please advise, thank you for your help.
Was this review helpful? (0/0)
Some questions
Maeve
7/24/2024 7:34 PM
Is it possible to configure my GK3000-1S0007 so as to execute FWD upon power up? Also, is there a way to have the up/down buttons set the frequency instead of the potentiometer?
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
2 hp (1.5 kW) VFD, Single Phase Input & Output
GK3000-1S0015
$243.08
Discounted 2 hp VFD, 1 phase for single phase AC motor, 220V - 240V 9.6 amps, brand new direct sale by manufacturer.
2 hp VFD, Single Phase to Three Phase VFD
GK3000-2S0015
$183.16
2 hp VFD, convert single phase to three phase for AC motor speed controls, 7 amps, IP20, RS485 enabled, manufacturer direct sale.
1/2 hp (0.4 kW) VFD, Single Phase Input & Output
GK3000-1S0004
$162.46
Inexpensive 1/2 hp VFD, 1 phase for single phase AC motor speed controls, 220V - 240V 4 amps, manufacturer direct sale.
5 hp (3.7 kW) VFD, 3 Phase 230V, 400V, 480V
GK3000-4T0037G
$293.51
Favorable price 5 hp (3.7 / 4 kW) VFD, three phase 230V, 400V, 480V, high performance vector variable frequency drive, IP20 enclosure, RS485 enabled, brand new direct sale by manufacturer.
1 hp (0.75 kW) VFD, 3 Phase 230V, 400V, 480V
GK3000-4T0007G
$206.49
Favorable price 1 hp (0.75 kW) VFD, three phase 230V/400V/480V 50Hz/60Hz for selection, sensorless vector variable frequency drive, RS485 enabled, strong overload capacity, manufacturer direct sale.