20 hp (15 kW) high performance vector variable frequency drive, three phase 220V, 380V, 460V for selection, RS485 enabled.
Specification:
| Basics | Model | GK3000-4T0150G/ GK3000-2T0150G |
| Capacity | 20 hp (15 kW) | |
| Shipping weight | 8 kg | |
| Dimension | 330*200*200 mm for GK3000-4T0150G/ 530*320*235 for GK3000-2T0150G | |
| I/O Feature | Rated current | 32A at 380V ~ 480V, 60A at 220V ~ 240V |
| Input voltage | 3 phase 220V /380V /460V AC ±15% (Optional) | |
| Input frequency | 50Hz/ 60Hz | |
| Output voltage | 3 phase AC 0~input voltage | |
| Output frequency | 0Hz~1000Hz | |
| Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds | |
| Control Feature | Control mode | V/F control; Sensorless vector control; |
| Communication | RS485 | |
| Speed regulation | 1:100 | |
| Start torque | 150% of rating torque at 1 Hz | |
| Speed control accuracy | ≤±0.5% of rating synchronous speed | |
| Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% | |
| Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz | |
| Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
| Interior PID controller | Be convenient to make closed-loop system | |
| Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
| Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
| Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
| Environment | Enclosure rating | IP 20 |
| Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% | |
| Humidity | 5%-95%, without condensation | |
| Altitude | ≤1000m; VFD will be derated if above 1000m | |
| Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
| Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
Tips: Variable frequency drive selection precautions
- The purpose of using VFD: Constant voltage control, constant current control or others.
- The load type of the VFD: Such as vane pump, displacement pump or others, pay special attention to the load performance curve, the performance curve determines the applications method.
- The VFD and the load matching problem:
1) Voltage matching: The rated voltage of VFD should be accordance with the rated voltage of the load.
2) Current matching: For ordinary centrifugal pump, VFD rated current and motor rated current should be accordant. For special loads such as deep water pumps, should refer to the motor performance parameters, use the maximum current to determine the VFD current and overload capacity.
3) Torque matching: This situation may occur when a constant torque load or a deceleration device is present. - When using VFD to drive high-speed motor, due to high-speed motor reactance is small, higher harmonics increase may cause output current value increases. So for high-speed motor, the capacity of VFD should be slightly higher than for ordinary motor.
- If the VFD will use long cable, should take measures to suppress effect from the long cable to the ground coupling capacitor, in order to avoid insufficient output of the VFD. So in this case, should choose a VFD with higher capacity or install a reactor on the output terminal.
- For some special applications, such as high temperature or high altitude, these situations will cause the VFD derating capacity, and should choose a higher capacity VFD.
Product reviews
VFD recommended by ATO
Sarahb
8/4/2021 1:44 AM
We have a job with a 240vac 1phase that I need to run a 3ph 15hp pump. Please send your recommendations for a VFD that I can purchase from you for this matter.
Was this review helpful? (0/0)
Efficiency of 1-phase VFD
Marla
9/27/2021 7:46 PM
What is your 1-phase variable frequency driving efficiency?
Was this review helpful? (0/0)
Guide for VFD
shelly
7/19/2023 7:32 PM
We have a GK3000-4T0150G VFD. We would like to program it so that after we start it does the following:
Ramp up to 25 Hz and hold for 5 seconds.
Ramp up in a couple of seconds to 50 Hz and hold for 30 seconds, then repeat this cycle until we manually stop it. The manual is not very easy to follow.
Can you please provide a guide to accomplish our specific application?
Ramp up to 25 Hz and hold for 5 seconds.
Ramp up in a couple of seconds to 50 Hz and hold for 30 seconds, then repeat this cycle until we manually stop it. The manual is not very easy to follow.
Can you please provide a guide to accomplish our specific application?
Was this review helpful? (0/0)
VFD program
coco
7/19/2023 8:57 PM
So there’s no way to program the VFD to alternate between the two speeds automatically?
We were hoping it could cycle between two speeds without any external control besides a start/stop signal.
We were hoping it could cycle between two speeds without any external control besides a start/stop signal.
Was this review helpful? (0/0)
What numbers am I not doing right?
Keran
8/14/2023 12:24 AM
My controller will not recognize the high and low pressure inputs that I need to run the irrigation system. I have a twenty hp pump and installed a 0-200psi pressure sensor when I installed the ATO controller it will shut off at 120 psi but will not restart when the pressure drops below 70psi. What numbers am I not doing right?
Was this review helpful? (0/0)
I need some instructions
Lucas
11/16/2023 2:21 AM
Hi, do you have instructions you could send me on what all needs to be input in the VFD before we do the autotune?
Was this review helpful? (0/0)
E.09 error
Biente
1/12/2025 8:29 PM
I ordered the inverter and motor runs very slow only and alarms E.09. The manual does not list this error.
Was this review helpful? (0/0)
VFD recommendation
edwin
2/5/2025 2:20 AM
we need a vfd having a specs plate that is 11kw , 415 v, 20.9A, 50hz, 1460 rpm, ip54, please recommend what vfd capacity we need to purchase, we are going to use it with our TADU FS-LR facing lathe machine, we are thinking of buying this 20 hp (15kW) VFD, 3 Phase 220V, 380V, 460V (SKU: GK3000-4T0150G). please reply as soon as possible.
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
15 hp (11 kW) VFD, 3 Phase 230V, 415V, 480V
GK3000-4T0110G
$634.44
Inexpensive 15 hp (11 kW) VFD, three phase 230V/415V/480V, high performance variable frequency drive, IP20 enclosure, RS485 enabled, brand new direct sale by manufacturer in China.
25 hp (18.5 kW) VFD, 3 Phase 240V, 420V, 480V
GK3000-4T0185G
$992.18
Favorable price 25 hp (18.5 kW) VFD, three phase 240V, 420V, 480V variable frequency drive, IP20, RS485 enabled, brand new direct sale by Chinese manufacturer with wholesale price.
5 hp (3.7 kW) VFD, 3 Phase 230V, 400V, 480V
GK3000-4T0037G
$293.51
Favorable price 5 hp (3.7 / 4 kW) VFD, three phase 230V, 400V, 480V, high performance vector variable frequency drive, IP20 enclosure, RS485 enabled, brand new direct sale by manufacturer.
20 hp (15 kW) Soft starter, 30 A, 3ph 220v/380v/480v
GS-015
$389.21
Cheap price 20 hp soft starter, 15 kW three phase 220v, 380v, 480v AC motor soft start, reduce motor starting current & voltage, protect motor from over-voltage, over-current and phase unbalance etc.
60 hp (45 kW) Soft starter, 90 A, 3ph 240v/400v/480v
GS-045
$543.91
Affordable 60 hp soft starter, 45 kW three phase 240v, 400v, 480v AC motor starter, protect AC induction motor from inrush current impact, buy from Chinese manufacturer directly.