125 hp (90 kW) VFD, 3 Phase 220V, 415V, 480V

$3,741.60
Cheap price 125 hp (90 kW) VFD for induction motor speed controls, three phase 220V, 415V, 480V energy saving variable frequency drive, direct sale by manufacturer in wholesale price.
SKU: GK3000-4T0900G
Free Shipping
Delivery date: 6-12 days

125 hp heavy duty variable frequency drive, three phase 220V, 415V, 480V for selection, brand new direct sale by manufacturer.

Specification:

BasicsModelGK3000-4T0900G/ GK3000-2T0900G
Capacity125 hp (90 kW)
Shipping weight51 kg
Dimension650*400*300 mm
I/O FeatureRated current176A at 380V ~ 480V, 380A at 220V ~ 240V
Input voltage3 phase 220V /415V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive loading debugging process

  1. Manually operate the stop button of the inverter panel to observe the stopping of the motor and the display window of the inverter to see if there is any abnormality.
  2. If the VFD has overcurrent protection during motor stopping, the acceleration deceleration time should be reset. If the overcurrent occurs during the start-up process, the acceleration time may be extended. If the overcurrent occurs during the braking process, the deceleration time should be extended.
  3. If the VFD is still protected in the limited time, change the stopping operating curve from straight to S-shaped, U-shaped or S-shaped, anti-U-shaped.
  4. If the VFD still has a running fault, try to increase the maximum current protection value, but cannot cancel the protection, and should leave at least 10% to 20% protection margin.
  5. If the Problem still cannot be solved, replace a higher power VFD.
  6. If the VFD drives the motor in the boot process does not reach the preset speed, there may be two cases:
    (1) Electromechanical resonance occurs in the system, which can be judged from the sound of the motor. Depending on the frequency of the system, set the jump across and span on the VPf curve. When the motor is accelerating, it will automatically skip these frequency segments to ensure properly operation.
    (2) If the motor torque output capacity is not enough, the manual torque lifting function can be set. The set value should not be too high, or the motor temperature will be increased. If it still have problem, should use VPf ratio constant method, or switch no-speed sensor space vector control method. For fan and pump loads, should reduce the curve values of the torque reduction.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
125hp VFD shipping to New Zealand
5
Matthew
Avatar
4/27/2018 12:45 AM
Are you sure the shopping of this 125 hp VFD is free of charge to New Zealand?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we confirm shipping is free of charge to New Zealand.
Do you accept credit card for instant payments?
5
Gabriele
Avatar
1/18/2022 7:36 PM
Do you accept credit card for instant payments?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can place your order directly online at our web site by credit card.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

125 hp heavy duty variable frequency drive, three phase 220V, 415V, 480V for selection, brand new direct sale by manufacturer.

Specification:

BasicsModelGK3000-4T0900G/ GK3000-2T0900G
Capacity125 hp (90 kW)
Shipping weight51 kg
Dimension650*400*300 mm
I/O FeatureRated current176A at 380V ~ 480V, 380A at 220V ~ 240V
Input voltage3 phase 220V /415V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive loading debugging process

  1. Manually operate the stop button of the inverter panel to observe the stopping of the motor and the display window of the inverter to see if there is any abnormality.
  2. If the VFD has overcurrent protection during motor stopping, the acceleration deceleration time should be reset. If the overcurrent occurs during the start-up process, the acceleration time may be extended. If the overcurrent occurs during the braking process, the deceleration time should be extended.
  3. If the VFD is still protected in the limited time, change the stopping operating curve from straight to S-shaped, U-shaped or S-shaped, anti-U-shaped.
  4. If the VFD still has a running fault, try to increase the maximum current protection value, but cannot cancel the protection, and should leave at least 10% to 20% protection margin.
  5. If the Problem still cannot be solved, replace a higher power VFD.
  6. If the VFD drives the motor in the boot process does not reach the preset speed, there may be two cases:
    (1) Electromechanical resonance occurs in the system, which can be judged from the sound of the motor. Depending on the frequency of the system, set the jump across and span on the VPf curve. When the motor is accelerating, it will automatically skip these frequency segments to ensure properly operation.
    (2) If the motor torque output capacity is not enough, the manual torque lifting function can be set. The set value should not be too high, or the motor temperature will be increased. If it still have problem, should use VPf ratio constant method, or switch no-speed sensor space vector control method. For fan and pump loads, should reduce the curve values of the torque reduction.
Product reviews
125hp VFD shipping to New Zealand
5
Matthew
Avatar
4/27/2018 12:45 AM
Are you sure the shopping of this 125 hp VFD is free of charge to New Zealand?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we confirm shipping is free of charge to New Zealand.
Do you accept credit card for instant payments?
5
Gabriele
Avatar
1/18/2022 7:36 PM
Do you accept credit card for instant payments?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can place your order directly online at our web site by credit card.
Only registered users can write reviews