150 hp (110 kW) VFD, 3 Phase 230V, 400V, 480V

$4,882.54
Low price 150 hp (110 kW) VFD for energy savings, three phase 230V, 400V, 480V for selection, heavy duty vector control variable frequency drive direct sale by manufacturer.
SKU: GK3000-4T1100G
Free Shipping
Delivery date: 6-12 days

150 hp VFD, 110 kW three phase 230V, 400V, 480V variable frequency drive with good performance.

Specification:

BasicsModelGK3000-4T1100G/ GK3000-2T1100G
Capacity150 hp (110 kW)
Shipping weight51 kg
Dimension650*400*300 mm
I/O FeatureRated current210A at 380V ~ 480V, 426A at 220V ~ 240V
Input voltage3 phase 230V /400V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150 % of rated current for 1 minute, 180 % of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the debate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive and upper computer debugging
After the no-load power-on test, with motor no-load test and on-load test, the manual basic settings of VFD have been completed, and VFD can be connected with the upper computer for further system debugging. Let the VFD control line directly connect with the upper computer control line, and change the operation mode to terminal control. According to the requirements of the upper computer system, set the VFD receive frequency signal terminal range to 0~5V or 0~10V, and set the sampling response speed of analog frequency signal. If additional monitor is required, select the analog output monitoring item and adjust the range of this monitoring item terminal.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
Geographical range for free shipping
5
Corrigan
Avatar
4/6/2021 6:56 PM
You state free shipping, does include Australia?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, all our 150hp variable frequency drives are free shipping to Australia (by Air).
My question about VFD
5
Juan
Avatar
12/28/2021 11:31 PM
Do you have an estimate on what% reduction of inrush current I can expect assuming single phase input and output VFD?
Was this review helpful? Yes No (0/0)
ATO Responded
You can totally eliminate inrush through increasing accelerating time.
Technical Problem
5
Adam
Avatar
6/14/2024 12:22 AM
1. We use this VFD to run a cabin up/down a slope. We send a run forward command to DI.1 and a run reverse command to Di1.2
All motor parameters are set.
2. The motor is wired correctly.
3. There is a warning signal that the cabin is about to move.
4. We cannot change the acceleration/deceleration times. This equipment had been in operation without fault for many years with a much smaller drive. Incoming voltage is correct an stable.
With no load in the cabin, everything runs correctly. We get the fault when we put 30% load in the cabin. Also, the DC voltage was monitored and the voltage across breaking resistor was monitored. The voltage between PB and   remained at 0 volts. There is no sudden change in the load. The fault happens after the drive has accelerated to full speed. There is a mechanical brake on the motor. However, it only engages when the motor is at zero speed, and the running signal confirms the drive is off. Dynamic brake refers to the breaking resistor.
Was this review helpful? Yes No (0/0)
ATO Responded
We think this problem is caused by the load you are using is too large.
Please refer to the following suggestions to set up running in vector mode:
1. First set the motor parameters:
P8.00=0, P8.01=3.75, P8.02=230, P8.03=13.6 P8.04=60,
p8.05=1680
2. In the state of P0.03=0, set P8.37=3. After FUN appears, press FWD for self-learning.
Then set P0.00=1, P9.11=100, and try running in vector mode.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

150 hp VFD, 110 kW three phase 230V, 400V, 480V variable frequency drive with good performance.

Specification:

BasicsModelGK3000-4T1100G/ GK3000-2T1100G
Capacity150 hp (110 kW)
Shipping weight51 kg
Dimension650*400*300 mm
I/O FeatureRated current210A at 380V ~ 480V, 426A at 220V ~ 240V
Input voltage3 phase 230V /400V /480V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltage3 phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150 % of rated current for 1 minute, 180 % of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the debate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive and upper computer debugging
After the no-load power-on test, with motor no-load test and on-load test, the manual basic settings of VFD have been completed, and VFD can be connected with the upper computer for further system debugging. Let the VFD control line directly connect with the upper computer control line, and change the operation mode to terminal control. According to the requirements of the upper computer system, set the VFD receive frequency signal terminal range to 0~5V or 0~10V, and set the sampling response speed of analog frequency signal. If additional monitor is required, select the analog output monitoring item and adjust the range of this monitoring item terminal.

Product reviews
Geographical range for free shipping
5
Corrigan
Avatar
4/6/2021 6:56 PM
You state free shipping, does include Australia?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, all our 150hp variable frequency drives are free shipping to Australia (by Air).
My question about VFD
5
Juan
Avatar
12/28/2021 11:31 PM
Do you have an estimate on what% reduction of inrush current I can expect assuming single phase input and output VFD?
Was this review helpful? Yes No (0/0)
ATO Responded
You can totally eliminate inrush through increasing accelerating time.
Technical Problem
5
Adam
Avatar
6/14/2024 12:22 AM
1. We use this VFD to run a cabin up/down a slope. We send a run forward command to DI.1 and a run reverse command to Di1.2
All motor parameters are set.
2. The motor is wired correctly.
3. There is a warning signal that the cabin is about to move.
4. We cannot change the acceleration/deceleration times. This equipment had been in operation without fault for many years with a much smaller drive. Incoming voltage is correct an stable.
With no load in the cabin, everything runs correctly. We get the fault when we put 30% load in the cabin. Also, the DC voltage was monitored and the voltage across breaking resistor was monitored. The voltage between PB and   remained at 0 volts. There is no sudden change in the load. The fault happens after the drive has accelerated to full speed. There is a mechanical brake on the motor. However, it only engages when the motor is at zero speed, and the running signal confirms the drive is off. Dynamic brake refers to the breaking resistor.
Was this review helpful? Yes No (0/0)
ATO Responded
We think this problem is caused by the load you are using is too large.
Please refer to the following suggestions to set up running in vector mode:
1. First set the motor parameters:
P8.00=0, P8.01=3.75, P8.02=230, P8.03=13.6 P8.04=60,
p8.05=1680
2. In the state of P0.03=0, set P8.37=3. After FUN appears, press FWD for self-learning.
Then set P0.00=1, P9.11=100, and try running in vector mode.
Only registered users can write reviews