300 hp (220 kW) VFD, 3 Phase 240V, 415V, 460V

$9,813.41
Economic 300 hp (220 kW) variable frequency drive (VFD) for energy savings, vary motor speed and make motor in soft starting to avoid inrush current, IP20, 426 amps, V/F & vector control.
SKU: GK3000-4T2200G
Ship to
*
*
Shipping Method
Name
Estimated Delivery
Price
No shipping options
Delivery date: 6-12 days

300 hp VFD, 220 kW VFD option for 240V, 415V, 460V etc, brand new direct sale by manufacturer.

Specification:

BasicsModelGK3000-4T2200G
Capacity300 hp (220 kW)
Shipping weight115 kg
Dimension810*640*350 mm
I/O FeatureRated current426A at 380V ~ 480V, 820A at 220V ~ 240V
Input voltageThree phase 240V /415V /460V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltageThree phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150 % of rated current for 1 minute, 200 % of rated current for 1 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the debate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive development trend

  1. Low electromagnetic noise and mute
    In addition to using the high frequency carrier sine wave SPWM modulation to achieve low noise, the VFD input side plus AC reactor or active power factor correction circuit APFC, and the inverter circuit also using SOFT-PWM control technology to improve the input current waveform, reduce the harmonic wave of the grid. The VFD meets the EMC international standard in anti-interference and inhibits the higher harmonic, and to achieve clean energy conversion.
  2. Customization
    The new VFD in order to better play the unique function of frequency control technology, and as far as possible to meet the needs of field control, derived from a number of customization models such as fan water pump air-conditioning dedicated model, heavy machinery dedicated model, AC elevator dedicated model, textile machinery dedicated model and so on.
  3. Systematic
    In addition to the development of digital, intelligent and multi-functional, the VFD is also developing to the integrated and systematic direction. The purpose is to provide the best system functions for users.
  4. Network
    The VFD can provide a variety of compatible communication interface, and can support a variety of different communication protocols. The built-in RS485 interface is able to input operation command and set the function code data from the computer.

How to Measure Circuits with a Digital Multimeter?

This video will show you how to measure electrical circuit using a digital multimeter.

VFD Two-Wire Control Wiring with Push Button for Forward Motor

In this video we've guided you through how to do VFD control wiring with a self-lock push button switch to run the motor in forward direction. We've covered everything from wiring to programming and even a test run. So just watch it through and hope you'll find it informative and helpful.

4-20mA speed Control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
Factors affecting the shortening of VFD service life
5
Ramon
Avatar
3/31/2021 7:12 PM
I have been told that using a VFD with one phase motor shortens the lifespan and also runs the motor hot. Does this 300 hp VFD not have those issues?
Was this review helpful? Yes No (0/0)
ATO Responded
No, most of modern motors works fine. Any way the motor will work very good with the VFD if the motor is VFD duty. So, it depends on your motor specs.
Operating temperature of VFD
5
Naylor
Avatar
10/8/2021 9:03 PM
If I'm going to use a 7.5 hp 230v 3 phase motor and the input is 240v single phase, will the 7.5 vfd be sufficient or will I need to upsize VFD. It will be installed in a garage, so it will have to deal with the summer heat and cold winter ambient temperature. Continuos duty.
Was this review helpful? Yes No (0/0)
ATO Responded
Generally, make 15% oversizing. And our VFD temperature range: –10℃~ +40℃; VFD will be derated if ambient temperature exceeds 40℃; each rise 1℃, the derate will be 5%.
An additional question
5
Warrior
Avatar
12/23/2021 11:25 PM
The compressor we will be driving has a permanent magnet synchronous motor.
Is the GK3000-2S0055G compatible with that type of motor, or can it drive just induction motors?
Must I choose vector control, or are V/F and vector control both viable options?
Was this review helpful? Yes No (0/0)
ATO Responded
Good news! Our GK9000 series VFD new generation can control permanent magnet synchronous motors, but you must choose a vector control.
Provide you magnet synchronous motors power, voltage, rated current, maximum current, or send us its name plate picture, so you can recommend the most suited model.
I'm looking for a VFD for a pump motor.
5
Katy
Avatar
1/24/2022 12:34 AM
I am looking to select a VFD appropriate for a pump motor. I was looking at SKU GK3000-SP1S1-1d5 to go along with a pump motor we may purchase: 1/3 HP, single phase, FLA 7/4 @ 115/230V. Can you please confirm if this is a good option?
Was this review helpful? Yes No (0/0)
ATO Responded
As long as your motor will be configured for 1-phase, 230V and your supply voltage (VFD input) is 110/120V, then VFD of GK3000-SP1S1-1d5 will be the appropriate drive for your pump motor.
Easy Installation
5
zhl
Avatar
4/26/2022 9:32 PM
I bought this 300hp VFD to power my J1 Head Bridgeport.
I read the instructions two or three times before I started the install. Installation was really easy, just needed to hookup my motor's wiring to UVW and 220 Vac.
I setup the VFD to match my motor's specification, I did this manually and not with the autotune setting, easy once you read the manual.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

300 hp VFD, 220 kW VFD option for 240V, 415V, 460V etc, brand new direct sale by manufacturer.

Specification:

BasicsModelGK3000-4T2200G
Capacity300 hp (220 kW)
Shipping weight115 kg
Dimension810*640*350 mm
I/O FeatureRated current426A at 380V ~ 480V, 820A at 220V ~ 240V
Input voltageThree phase 240V /415V /460V AC ±15% (Optional)
Input frequency50Hz/ 60Hz
Output voltageThree phase AC 0~input voltage
Output frequency0Hz~1000Hz
Over load capacity150 % of rated current for 1 minute, 200 % of rated current for 1 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the debate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Variable frequency drive development trend

  1. Low electromagnetic noise and mute
    In addition to using the high frequency carrier sine wave SPWM modulation to achieve low noise, the VFD input side plus AC reactor or active power factor correction circuit APFC, and the inverter circuit also using SOFT-PWM control technology to improve the input current waveform, reduce the harmonic wave of the grid. The VFD meets the EMC international standard in anti-interference and inhibits the higher harmonic, and to achieve clean energy conversion.
  2. Customization
    The new VFD in order to better play the unique function of frequency control technology, and as far as possible to meet the needs of field control, derived from a number of customization models such as fan water pump air-conditioning dedicated model, heavy machinery dedicated model, AC elevator dedicated model, textile machinery dedicated model and so on.
  3. Systematic
    In addition to the development of digital, intelligent and multi-functional, the VFD is also developing to the integrated and systematic direction. The purpose is to provide the best system functions for users.
  4. Network
    The VFD can provide a variety of compatible communication interface, and can support a variety of different communication protocols. The built-in RS485 interface is able to input operation command and set the function code data from the computer.
Product reviews
Factors affecting the shortening of VFD service life
5
Ramon
Avatar
3/31/2021 7:12 PM
I have been told that using a VFD with one phase motor shortens the lifespan and also runs the motor hot. Does this 300 hp VFD not have those issues?
Was this review helpful? Yes No (0/0)
ATO Responded
No, most of modern motors works fine. Any way the motor will work very good with the VFD if the motor is VFD duty. So, it depends on your motor specs.
Operating temperature of VFD
5
Naylor
Avatar
10/8/2021 9:03 PM
If I'm going to use a 7.5 hp 230v 3 phase motor and the input is 240v single phase, will the 7.5 vfd be sufficient or will I need to upsize VFD. It will be installed in a garage, so it will have to deal with the summer heat and cold winter ambient temperature. Continuos duty.
Was this review helpful? Yes No (0/0)
ATO Responded
Generally, make 15% oversizing. And our VFD temperature range: –10℃~ +40℃; VFD will be derated if ambient temperature exceeds 40℃; each rise 1℃, the derate will be 5%.
An additional question
5
Warrior
Avatar
12/23/2021 11:25 PM
The compressor we will be driving has a permanent magnet synchronous motor.
Is the GK3000-2S0055G compatible with that type of motor, or can it drive just induction motors?
Must I choose vector control, or are V/F and vector control both viable options?
Was this review helpful? Yes No (0/0)
ATO Responded
Good news! Our GK9000 series VFD new generation can control permanent magnet synchronous motors, but you must choose a vector control.
Provide you magnet synchronous motors power, voltage, rated current, maximum current, or send us its name plate picture, so you can recommend the most suited model.
I'm looking for a VFD for a pump motor.
5
Katy
Avatar
1/24/2022 12:34 AM
I am looking to select a VFD appropriate for a pump motor. I was looking at SKU GK3000-SP1S1-1d5 to go along with a pump motor we may purchase: 1/3 HP, single phase, FLA 7/4 @ 115/230V. Can you please confirm if this is a good option?
Was this review helpful? Yes No (0/0)
ATO Responded
As long as your motor will be configured for 1-phase, 230V and your supply voltage (VFD input) is 110/120V, then VFD of GK3000-SP1S1-1d5 will be the appropriate drive for your pump motor.
Easy Installation
5
zhl
Avatar
4/26/2022 9:32 PM
I bought this 300hp VFD to power my J1 Head Bridgeport.
I read the instructions two or three times before I started the install. Installation was really easy, just needed to hookup my motor's wiring to UVW and 220 Vac.
I setup the VFD to match my motor's specification, I did this manually and not with the autotune setting, easy once you read the manual.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews