300 hp VFD, 220 kW VFD option for 240V, 415V, 460V etc, brand new direct sale by manufacturer.
Specification:
| Basics | Model | GK3000-4T2200G |
| Capacity | 300 hp (220 kW) | |
| Shipping weight | 115 kg | |
| Dimension | 810*640*350 mm | |
| I/O Feature | Rated current | 426A at 380V ~ 480V, 820A at 220V ~ 240V |
| Input voltage | Three phase 240V /415V /460V AC ±15% (Optional) | |
| Input frequency | 50Hz/ 60Hz | |
| Output voltage | Three phase AC 0~input voltage | |
| Output frequency | 0Hz~1000Hz | |
| Over load capacity | 150 % of rated current for 1 minute, 200 % of rated current for 1 seconds | |
| Control Feature | Control mode | V/F control; Sensorless vector control; |
| Communication | RS485 | |
| Speed regulation | 1:100 | |
| Start torque | 150% of rating torque at 1 Hz | |
| Speed control accuracy | ≤±0.5% of rating synchronous speed | |
| Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% | |
| Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz | |
| Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
| Interior PID controller | Be convenient to make closed-loop system | |
| Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
| Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
| Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
| Environment | Enclosure rating | IP 20 |
| Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the debate will be 5% | |
| Humidity | 5%-95%, without condensation | |
| Altitude | ≤1000m; VFD will be derated if above 1000m | |
| Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
| Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
Tips: Variable frequency drive development trend
- Low electromagnetic noise and mute
In addition to using the high frequency carrier sine wave SPWM modulation to achieve low noise, the VFD input side plus AC reactor or active power factor correction circuit APFC, and the inverter circuit also using SOFT-PWM control technology to improve the input current waveform, reduce the harmonic wave of the grid. The VFD meets the EMC international standard in anti-interference and inhibits the higher harmonic, and to achieve clean energy conversion. - Customization
The new VFD in order to better play the unique function of frequency control technology, and as far as possible to meet the needs of field control, derived from a number of customization models such as fan water pump air-conditioning dedicated model, heavy machinery dedicated model, AC elevator dedicated model, textile machinery dedicated model and so on. - Systematic
In addition to the development of digital, intelligent and multi-functional, the VFD is also developing to the integrated and systematic direction. The purpose is to provide the best system functions for users. - Network
The VFD can provide a variety of compatible communication interface, and can support a variety of different communication protocols. The built-in RS485 interface is able to input operation command and set the function code data from the computer.
Product reviews
Factors affecting the shortening of VFD service life
Ramon
3/31/2021 7:12 PM
I have been told that using a VFD with one phase motor shortens the lifespan and also runs the motor hot. Does this 300 hp VFD not have those issues?
Was this review helpful? (0/0)
Operating temperature of VFD
Naylor
10/8/2021 9:03 PM
If I'm going to use a 7.5 hp 230v 3 phase motor and the input is 240v single phase, will the 7.5 vfd be sufficient or will I need to upsize VFD. It will be installed in a garage, so it will have to deal with the summer heat and cold winter ambient temperature. Continuos duty.
Was this review helpful? (0/0)
An additional question
Warrior
12/23/2021 11:25 PM
The compressor we will be driving has a permanent magnet synchronous motor.
Is the GK3000-2S0055G compatible with that type of motor, or can it drive just induction motors?
Must I choose vector control, or are V/F and vector control both viable options?
Is the GK3000-2S0055G compatible with that type of motor, or can it drive just induction motors?
Must I choose vector control, or are V/F and vector control both viable options?
Was this review helpful? (0/0)
I'm looking for a VFD for a pump motor.
Katy
1/24/2022 12:34 AM
I am looking to select a VFD appropriate for a pump motor. I was looking at SKU GK3000-SP1S1-1d5 to go along with a pump motor we may purchase: 1/3 HP, single phase, FLA 7/4 @ 115/230V. Can you please confirm if this is a good option?
Was this review helpful? (0/0)
Easy Installation
zhl
4/26/2022 9:32 PM
I bought this 300hp VFD to power my J1 Head Bridgeport.
I read the instructions two or three times before I started the install. Installation was really easy, just needed to hookup my motor's wiring to UVW and 220 Vac.
I setup the VFD to match my motor's specification, I did this manually and not with the autotune setting, easy once you read the manual.
I read the instructions two or three times before I started the install. Installation was really easy, just needed to hookup my motor's wiring to UVW and 220 Vac.
I setup the VFD to match my motor's specification, I did this manually and not with the autotune setting, easy once you read the manual.
Was this review helpful? (0/0)
Only registered users can write reviews