1 hp VFD, Single Phase 120V Input, 1ph/3ph 220V Output

$284.61
1 hp single phase 120v input, single phase and three phase 220v output variable frequency drive. Running your 1-phase/3-phase motors with ATO VFDs, via 120 volt supply.
SKU: GK3000-SP1S1-d75
Free Shipping
Delivery date: 2-3 days

1 hp VFD, 0.75 kW, single phase 110v/120v input to single phase 220v-240v output, single phase 110v/120v to three phase, manufacturer direct sale.

Specification:

Basics Model EM15-SP1S1-d75
Capacity 1 hp (0.75 kW)
Shipping weight 3 kg
Dimension (W x H x D) 120*205*166 mm
I/O Feature Rated current 4 A
Input voltage 1 phase 120V AC ±15% (Set FE-00=0)
Input frequency 50Hz/60Hz
Output voltage 1 phase or 3 phase 220V AC ±15%
Output frequency

0~320Hz (SFC)

Control Feature Control mode V/F control; vector control
Communication Offer RS485 communication interface, support MODBUS-RTU communication protocol
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating IP 20
Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity smaller than 95%RH, non-condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Vibration Less than 5.9 m/s2 (0.6 g)
Cooling forced air cooling
Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details:

 

1ph/3ph VFD Single Phase 120V Input Details

Tips: Choose a VFD base on motor rated current

When a motor power is stated, it is always the mechanical power, shaft power i.e. NOT the input electrical power.
Variable frequency drives (VFD) are also (mostly) rated in terms of kW albeit it's wrong. Because VFD output is electrical (not mechanical). Mechanical power (i.e. motor shaft power) is always "active" power, where in electricity we also have reactive (doing nothing but losses) power. The apparent (total) power (stated in terms of kVA) is vectorial sum of active and reactive power components.
For all those facts above, ATO highly recommend to select a VFD by matching motor current. This is the right way. Despite mathematically correct, we wouldn't select a VFD for partial load of motor. We would simply go for motor nominal (rated) current.
Finally the answer is: choose a VFD output current ≥ motor rated current.

Running a Three-phase Motor on a Single-phase Supply with a Frequency Converter

How to run a three phase or single phase motor with ATO VFD on 120V power supply. Take a 2 hp, single phase 120V input, single phase or three phase 220V output variable frequency drive as an example. It shows you how to wire, set parameters, commissioning VFD, run motors, etc.

VFD Programming for Stable Water Pressure in Water Supply System

A three-phase motor can be regulated using a single-phase 120V to three-phase 220V VFD, and control can be managed through terminals, as demonstrated in the following video.

Variable Frequency Drive Setting

In the video, it's demonstrated that ATO VFD offers multiple methods to adjust the frequency: Not only can you use the knob on the panel, but you can also utilize the buttons for adjustments.

Basic Troubleshooting Guide for VFD

In this video, ATO will show you the vfd basic troubleshooting guide.

How Many VFD Control Methods Do You Know?

Several methods to control the frequency of VFD:

1. Switch Button control: Use the switch signal to directly control the start and stop of the VFD (the VFD start frequency is fixed), and the multi-speed control method can be used to activate the speed of each section of the VFD.

2. Analog control: Use 5V or 0~20mA to control the frequency of the VFD, and at the same time can control the start and stop of the VFD in cooperation with the switch.

3. VFD potentiometer control: The VFD has its own potentiometer input terminal, and the VFD is directly controlled by the potentiometer.

4. Modbus-RTU control: Use RS485 interface to transmit data with Modbus-RTU protocol, which can monitor VFD, modify frequency, start and stop, etc.

5. DTU wireless remote control:Combine DTU terminal and VFD for wireless transmission. (DTU output analog quantity to control VFD frequency)

Running a Single or Three Phase Motor with a VFD on 120V Power

In this video, ATO will show you how to run a 120v variable frequency drive motor.

Running a Split-phase Motor with a 120V VFD (Terminal Control)

The ATO 120V inverter in the video can run single-phase motors/split-phase motors, three-phase motors. You can run the VFD in many ways.

Product reviews
1 hp VFD use
5
Garety
Avatar
3/14/2021 7:54 PM
Do I need an additional relay to use with the 1 hp VFD, or can I connect it directly to the motor?
Was this review helpful? Yes No (0/0)
ATO Responded
Just connect the 1 hp VFD directly to the motor.
1 hp VFD delivery time
5
Amanda
Avatar
4/27/2021 12:26 AM
We are looking into 1 hp VFD, single phase 120V Input, 1ph/3ph 220V output drive to control a couple fans, want to make sure we can control these with a pressure transducer having 0-10v dc signal? Also what is the lead time if we order two?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can control the drive via 0-10V signal.
Total delivery time to your address: Approx 1 week after payment is made.
Questions about 1hp VFD parameters
5
Deborah
Avatar
11/8/2021 8:12 PM
For your 1hp variable frequency drives. Are the parameters saved when set, or is there a process to save them?
Was this review helpful? Yes No (0/0)
ATO Responded
The parameters are saved automatically when set.
Application Question
5
Matt
Avatar
7/18/2022 7:58 AM
1. I am looking to drive a spindle motor at 230v with 3.3FLA. (1HP) . Should I upsize and move to the 2hp unit?

2. The table in the description listed rated current as 4 amps (7 amps for 2hp unit). Is this input or output rating?

3. What are the recommended feeder circuits wire gauge and breaker amperage for both this unit and the 2hp unit?

4. Do you recommend wiring in fuses before the VFD (i.e. slow blow fuse, etc)?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Yes, it is safer to use 2HP capacity.
2. 4A is the output rating.
3. 1.5mm square wire is enough. The current of the circuit breaker should be more than 2 times greater than the output current of the inverter.
4. A fuse can be added to the VFD input.
We want the protocol of capabilities on this modbus.
5
faye
Avatar
2/28/2023 8:49 PM
For us, modbus is certainly good.
Then can you give us the protocol of capabilities on this modbus?
Then what type do you have in mind and then can you give us a graduated price please?
Thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, we don't have a protocol of capabilities. Our products use the national standard protocol, and we use the MODBUS protocol that comes with the bottom layer of the TI chip. May I ask what architecture you use to make the bottom layer, the architecture generally has a protocol.
This VFD just doesn't work
5
Cboh
Avatar
3/2/2023 12:30 AM
Finally received a replacement spindle motor to eliminate that as a potential issue but I get the same error 2. I have re-checked every setting many times and this thing just doesn't work. I don't know what else to do.
Was this review helpful? Yes No (0/0)
ATO Responded
Okay, in order to solve your problem as soon as possible, please feedback the following information:
1.   Please send us your spindle motor nameplate label.
2.   Please send a video to tell us how you set the parameters of the VFD. Please make sure the parameters of F1-01~F1~04 are correct. The video should show that when you finish the parameter setting, connect the spindle motor, start running, and then show the error code err02. You can send us the large video file via wetransfer.com.
A couple of questions regarding this VFD
5
lolly
Avatar
6/14/2023 1:54 AM
I have a couple of questions regarding this 1-phase 115VAC VFD:
Is the optimum potentiometer value used for a speed reference signal to terminal A11?
I am using a foot pedal to control speed and have possible options of 1000, 5000 or 10,000 ohms, which is best?
Foot pedal will also provide Run/Stop signal to drive via a single N.O contact.
Contact closed = Run, Open = Stop.
I also need to interface an E-Stop push button into this drive.
Can you provide some guidance regarding the best way to wire your drive for this set-up. Any special parameter settings that I need for this set-up?
I would like to configure Relay Output 1 and 2 to be:
1=Run indicator light
2=VFD Fault indicator light.
What parameters need to be set to do this?
Best Regards
Was this review helpful? Yes No (0/0)
ATO Responded
What is your order number? Please let us know so we can better help you. Hope you can understand.
1. We recommend you use 1-5K ohms resistors.
2. Connect the pedal switch to DI1 and COM, close to start, open to stop, please set parameter F0-02=1.
3. F5-04=1 running output (corresponding to relay TA1 TC1)
     F5-02=2 fault output (for relay TA2 TC2)
     F9-09=0 (need to be set, otherwise the relay will not act when fault occurs).
How to change the default frequency from 50 Hz to 60 Hz?
5
lily
Avatar
9/4/2023 3:21 AM
I purchased a couple of VFDs from you and they say they can be changed to 60 hz from 50 hz default. I need to know how to please.
Was this review helpful? Yes No (0/0)
ATO Responded
If you want to get 60HZ output, just set F0-10=60, F0-12=60, you can try it.
Can I connect the input to 120 VAC 60 Hz?
5
Cliff
Avatar
10/16/2023 7:00 PM
Manual says to be used with a solar inverter, can I connect the input to 120 VAC 60 Hz?
Was this review helpful? Yes No (0/0)
ATO Responded
You can hook up the input to 120 VAC 60 Hz, but it will take more than 3x the power from the sun to run the VFD's rating.
If the power is Not enough, the VFD will Not work.
Can you Have a this VFD run off of a 4-20ma input as well as run at a set speed?
5
Gabe
Avatar
11/10/2023 6:13 PM
I would like to use DI1 to tell the vfd to run based on a 4-20ma input from AI1. Then I would like to use DI2 to tell the vfd to run a specific speed of 60Hz.

Is this possible to do? If so what do I need to set?

Also is there a complete manual that lists all the registers in the VFD? I am also curious where there is documentation explaining how to set up the Relay outputs.
Was this review helpful? Yes No (0/0)
ATO Responded
This VFD does not have the function of switching between 2 different frequencies. The relay output can be described in parameter F5-02.
I have a question
4
Viola
Avatar
8/6/2024 3:13 AM
There are two relays built into this VFD. My question is if I can configure the digital pins such that if I drive one of them high they will open or close the relay.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our VFD's built-in relays cannot be configured with digital pin functions.
Display speed
5
Perth
Avatar
4/15/2025 1:47 AM
Hello, I would like to know if this GK3000-SP1S1-d75 inverter can display the speed.
Was this review helpful? Yes No (0/0)
ATO Responded
This inverter cannot display the speed, but the frequency value can be read by displaying the frequency.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

1 hp VFD, 0.75 kW, single phase 110v/120v input to single phase 220v-240v output, single phase 110v/120v to three phase, manufacturer direct sale.

Specification:

Basics Model EM15-SP1S1-d75
Capacity 1 hp (0.75 kW)
Shipping weight 3 kg
Dimension (W x H x D) 120*205*166 mm
I/O Feature Rated current 4 A
Input voltage 1 phase 120V AC ±15% (Set FE-00=0)
Input frequency 50Hz/60Hz
Output voltage 1 phase or 3 phase 220V AC ±15%
Output frequency

0~320Hz (SFC)

Control Feature Control mode V/F control; vector control
Communication Offer RS485 communication interface, support MODBUS-RTU communication protocol
Speed regulation 1:100
Start torque 150% of rating torque at 1 Hz
Speed control accuracy ≤±0.5% of rating synchronous speed
Frequency precision Digital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolution Analog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boost Automatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controller Be convenient to make closed-loop system
Automatic energy save running Optimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR) Can keep constant output voltage when power source voltage varies.
Automatic current limiting Limit running current automatically to avoid frequent over-current which will cause trip
Environment Enclosure rating IP 20
Temperature –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity smaller than 95%RH, non-condensation
Altitude ≤1000m; VFD will be derated if above 1000m
Vibration Less than 5.9 m/s2 (0.6 g)
Cooling forced air cooling
Store environment –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details:

 

1ph/3ph VFD Single Phase 120V Input Details

Tips: Choose a VFD base on motor rated current

When a motor power is stated, it is always the mechanical power, shaft power i.e. NOT the input electrical power.
Variable frequency drives (VFD) are also (mostly) rated in terms of kW albeit it's wrong. Because VFD output is electrical (not mechanical). Mechanical power (i.e. motor shaft power) is always "active" power, where in electricity we also have reactive (doing nothing but losses) power. The apparent (total) power (stated in terms of kVA) is vectorial sum of active and reactive power components.
For all those facts above, ATO highly recommend to select a VFD by matching motor current. This is the right way. Despite mathematically correct, we wouldn't select a VFD for partial load of motor. We would simply go for motor nominal (rated) current.
Finally the answer is: choose a VFD output current ≥ motor rated current.

Product reviews
1 hp VFD use
5
Garety
Avatar
3/14/2021 7:54 PM
Do I need an additional relay to use with the 1 hp VFD, or can I connect it directly to the motor?
Was this review helpful? Yes No (0/0)
ATO Responded
Just connect the 1 hp VFD directly to the motor.
1 hp VFD delivery time
5
Amanda
Avatar
4/27/2021 12:26 AM
We are looking into 1 hp VFD, single phase 120V Input, 1ph/3ph 220V output drive to control a couple fans, want to make sure we can control these with a pressure transducer having 0-10v dc signal? Also what is the lead time if we order two?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, you can control the drive via 0-10V signal.
Total delivery time to your address: Approx 1 week after payment is made.
Questions about 1hp VFD parameters
5
Deborah
Avatar
11/8/2021 8:12 PM
For your 1hp variable frequency drives. Are the parameters saved when set, or is there a process to save them?
Was this review helpful? Yes No (0/0)
ATO Responded
The parameters are saved automatically when set.
Application Question
5
Matt
Avatar
7/18/2022 7:58 AM
1. I am looking to drive a spindle motor at 230v with 3.3FLA. (1HP) . Should I upsize and move to the 2hp unit?

2. The table in the description listed rated current as 4 amps (7 amps for 2hp unit). Is this input or output rating?

3. What are the recommended feeder circuits wire gauge and breaker amperage for both this unit and the 2hp unit?

4. Do you recommend wiring in fuses before the VFD (i.e. slow blow fuse, etc)?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Yes, it is safer to use 2HP capacity.
2. 4A is the output rating.
3. 1.5mm square wire is enough. The current of the circuit breaker should be more than 2 times greater than the output current of the inverter.
4. A fuse can be added to the VFD input.
We want the protocol of capabilities on this modbus.
5
faye
Avatar
2/28/2023 8:49 PM
For us, modbus is certainly good.
Then can you give us the protocol of capabilities on this modbus?
Then what type do you have in mind and then can you give us a graduated price please?
Thanks.
Was this review helpful? Yes No (0/0)
ATO Responded
Sorry, we don't have a protocol of capabilities. Our products use the national standard protocol, and we use the MODBUS protocol that comes with the bottom layer of the TI chip. May I ask what architecture you use to make the bottom layer, the architecture generally has a protocol.
This VFD just doesn't work
5
Cboh
Avatar
3/2/2023 12:30 AM
Finally received a replacement spindle motor to eliminate that as a potential issue but I get the same error 2. I have re-checked every setting many times and this thing just doesn't work. I don't know what else to do.
Was this review helpful? Yes No (0/0)
ATO Responded
Okay, in order to solve your problem as soon as possible, please feedback the following information:
1.   Please send us your spindle motor nameplate label.
2.   Please send a video to tell us how you set the parameters of the VFD. Please make sure the parameters of F1-01~F1~04 are correct. The video should show that when you finish the parameter setting, connect the spindle motor, start running, and then show the error code err02. You can send us the large video file via wetransfer.com.
A couple of questions regarding this VFD
5
lolly
Avatar
6/14/2023 1:54 AM
I have a couple of questions regarding this 1-phase 115VAC VFD:
Is the optimum potentiometer value used for a speed reference signal to terminal A11?
I am using a foot pedal to control speed and have possible options of 1000, 5000 or 10,000 ohms, which is best?
Foot pedal will also provide Run/Stop signal to drive via a single N.O contact.
Contact closed = Run, Open = Stop.
I also need to interface an E-Stop push button into this drive.
Can you provide some guidance regarding the best way to wire your drive for this set-up. Any special parameter settings that I need for this set-up?
I would like to configure Relay Output 1 and 2 to be:
1=Run indicator light
2=VFD Fault indicator light.
What parameters need to be set to do this?
Best Regards
Was this review helpful? Yes No (0/0)
ATO Responded
What is your order number? Please let us know so we can better help you. Hope you can understand.
1. We recommend you use 1-5K ohms resistors.
2. Connect the pedal switch to DI1 and COM, close to start, open to stop, please set parameter F0-02=1.
3. F5-04=1 running output (corresponding to relay TA1 TC1)
     F5-02=2 fault output (for relay TA2 TC2)
     F9-09=0 (need to be set, otherwise the relay will not act when fault occurs).
How to change the default frequency from 50 Hz to 60 Hz?
5
lily
Avatar
9/4/2023 3:21 AM
I purchased a couple of VFDs from you and they say they can be changed to 60 hz from 50 hz default. I need to know how to please.
Was this review helpful? Yes No (0/0)
ATO Responded
If you want to get 60HZ output, just set F0-10=60, F0-12=60, you can try it.
Can I connect the input to 120 VAC 60 Hz?
5
Cliff
Avatar
10/16/2023 7:00 PM
Manual says to be used with a solar inverter, can I connect the input to 120 VAC 60 Hz?
Was this review helpful? Yes No (0/0)
ATO Responded
You can hook up the input to 120 VAC 60 Hz, but it will take more than 3x the power from the sun to run the VFD's rating.
If the power is Not enough, the VFD will Not work.
Can you Have a this VFD run off of a 4-20ma input as well as run at a set speed?
5
Gabe
Avatar
11/10/2023 6:13 PM
I would like to use DI1 to tell the vfd to run based on a 4-20ma input from AI1. Then I would like to use DI2 to tell the vfd to run a specific speed of 60Hz.

Is this possible to do? If so what do I need to set?

Also is there a complete manual that lists all the registers in the VFD? I am also curious where there is documentation explaining how to set up the Relay outputs.
Was this review helpful? Yes No (0/0)
ATO Responded
This VFD does not have the function of switching between 2 different frequencies. The relay output can be described in parameter F5-02.
I have a question
4
Viola
Avatar
8/6/2024 3:13 AM
There are two relays built into this VFD. My question is if I can configure the digital pins such that if I drive one of them high they will open or close the relay.
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our VFD's built-in relays cannot be configured with digital pin functions.
Display speed
5
Perth
Avatar
4/15/2025 1:47 AM
Hello, I would like to know if this GK3000-SP1S1-d75 inverter can display the speed.
Was this review helpful? Yes No (0/0)
ATO Responded
This inverter cannot display the speed, but the frequency value can be read by displaying the frequency.
Only registered users can write reviews
Customers who bought this item also bought

2 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0015
$183.16
2 hp VFD, convert single phase to three phase for AC motor speed controls, 7 amps, IP20, RS485 enabled, manufacturer direct sale.

5 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0037
$294.31
5hp variable frequency drive, single phase to three phase VFD, 17 amps, RS485 enabled, shipping weight 4kg, manufacturer direct sale.

2 hp (1.5 kW) VFD, 3 Phase 240V, 415V, 480V

GK3000-4T0015G
$218.41
Cheap price 2 hp (1.5 kW) VFD, three phase 240V, 415V, 480V for choice, brand new sensorless vector variable frequency drive, RS485 enabled, strong overload capacity, manufacturer direct sale.

2 hp (1.5 kW) VFD, Single Phase Input & Output

GK3000-1S0015
$243.08
Discounted 2 hp VFD, 1 phase for single phase AC motor, 220V - 240V 9.6 amps, brand new direct sale by manufacturer.

3 hp VFD, Single Phase 120V Input, 1ph/3ph 220V Output

GK3000-SP1S1-2d2
$346.10
3 hp single phase 120v input, single phase and three phase 220v output variable frequency drive, specially designed for 120v power supply, manufacturer direct sale.