3 hp (2.2 kW) VFD, single phase input & output, single phase to three phase, 110v-120v input, 220v-240v output.
Specification:
| Basics | Model | EM15-SP1S1-2d2 |
| Capacity | 3 hp (2.2 kW) | |
| Shipping weight | 3 kg | |
| Dimension (W x H x D) | 120*205*166 mm | |
| I/O Feature | Rated current | 10 A |
| Input voltage | 1 phase 120V AC ±15% (Set FE-00=0) | |
| Input frequency | 50Hz/60Hz | |
| Output voltage | 1 phase or 3 phase 220V AC ±15% | |
| Output frequency | 0~320Hz (SFC) | |
| Control Feature | Control mode | V/F control; vector control |
| Communication | Offer RS485 communication interface, support MODBUS-RTU communication protocol | |
| Speed regulation | 1:100 | |
| Start torque | 150% of rating torque at 1 Hz | |
| Speed control accuracy | ≤±0.5% of rating synchronous speed | |
| Frequency precision | Digital setting: max frequency x± 0.01%; | |
| Analog setting: max frequency x± 0.2% | ||
| Frequency resolution | Analog setting: 0.1% of max frequency; | |
| Digital setting: 0.01Hz | ||
| Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
| Interior PID controller | Be convenient to make closed-loop system | |
| Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
| Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
| Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
| Environment | Enclosure rating | IP 20 |
| Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% | |
| Humidity | smaller than 95%RH, non-condensation | |
| Altitude | ≤1000m; VFD will be derated if above 1000m | |
| Vibration | Less than 5.9 m/s2 (0.6 g) | |
| Cooling | forced air cooling | |
| Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
Tips: Running a 3-phase motor from single phase supply
Details

If you want to connect a 3-phase motor to a single phase power supply, then you have several solutions:
- Professional: use a VFD with single phase input and convert to 3-phase output, this is generally available for low power VFD (few horsepower).
- Professional: apply a specially wound transformer that also mimic a 3-phase system from a single phase power supply. Expect difficulties to source and high price.
- DIY: calculate a capacitor that will be connected between the remaining phases, such to apply it a phase shift and to mimic a 3-phase system.
Product reviews
3hp VFD question answering
Pilgrim
4/5/2021 7:02 PM
Do we still need to debate VFDs when used on single phase input power like we did with the older VFDs or have you done something like beefing up the input diodes and caps so they will be able to output the same power as on 3 Ph?
Was this review helpful? (0/0)
3hp VFD output voltage
Pence
6/10/2021 12:16 AM
I am trying to drive a custom solenoid at variable frequency. Curious to know if the output voltage of GK3000-SP1S1-2d2 is variable.
Was this review helpful? (0/0)
What's wrong with my 3hp VFD?
Glack
5/25/2022 3:29 AM
I got a problem with your drive, with a 3 phases motor the output voltage drop to 150 and without load it has 220. What's wrong?
Was this review helpful? (0/0)
Is it safe to do so?
Diggy
3/1/2023 8:02 PM
So I wired my AC Variable frequency drive to my single phase 220V motor, on first start up it ran fine for about 3 or 4 min, and then the starting capacitor got hot and started to smoke, and a small mount of the oil came out of the capacitor. I believe what happened is the switch never engaged so I stayed on the start up windings. So it will run if I give it a little help getting it to spin, but that capacitor gets really hot. The centrifugal switch will not ingage until it is at about 75% rpms. And I am trying to run the motor at much slower speeds. Is it possible to bypass the centrifugal switch and the bad capacitor possibly? Is it safe to do so?
Was this review helpful? (0/0)
Please give me more details of VFD
faye
7/20/2023 9:05 PM
We currently have your drives installed with the motors in the attached picture. We were informed by you yesterday that these are the incorrect drives.
We are going to replace them with the drives you recommended (model EM15-SP1S1-2d2). Before we install these new drives, we would like for you to give us detailed step-by-step programming instructions.
We need this detailed info prior. Is this something you can help with?
We are going to replace them with the drives you recommended (model EM15-SP1S1-2d2). Before we install these new drives, we would like for you to give us detailed step-by-step programming instructions.
We need this detailed info prior. Is this something you can help with?
Was this review helpful? (0/0)
getting an error
Mason
11/6/2023 11:25 PM
Hi, I keep getting an error code 02 now when I start the motor. Can you get any ideas how to fix this?
Was this review helpful? (0/0)
get error code
Dylan
11/7/2023 12:17 AM
I get error code 40 now I went through all the setting and made sure they were right. Now I get a error 0040 .
Was this review helpful? (0/0)
I want to know that...
Cyril
1/8/2024 7:53 PM
I was able to connect VFD to my controller successfully though is it possible to signal back to my controller if there is an error.
Also I’d like to add a breaking resistor to it though I couldn’t find anything in the manual about that.
How do I determine the resistance that I need for the breaking resistor?
Also I’d like to add a breaking resistor to it though I couldn’t find anything in the manual about that.
How do I determine the resistance that I need for the breaking resistor?
Was this review helpful? (0/0)
Practical VFD
Jimmyy
6/16/2024 8:51 PM
This single-phase VFD has quite complete functions. Anyway, I am looking for a wiring diagram to hook up an external potentiometer to control motor speed.
Was this review helpful? (0/0)
Only registered users can write reviews
Customers who bought this item also bought
3 hp VFD, Single Phase to Three Phase VFD
GK3000-2S0022
$238.14
Low price 3hp VFD, convert 220V/230V/240V 1 phase to 3 phase, 9.6 amps, RS485 enabled, shipping weight 3kg, manufacturer direct sale.
5 hp VFD, Single Phase to Three Phase VFD
GK3000-2S0037
$294.31
5hp variable frequency drive, single phase to three phase VFD, 17 amps, RS485 enabled, shipping weight 4kg, manufacturer direct sale.
2 hp VFD, Single Phase 120V Input, 1ph/3ph 220V Output
GK3000-SP1S1-1d5
$315.38
Affordable 2 hp variable frequency drive, single phase 110v-120v input, single phase and three phase 220v-240v output, designed for driving single/three phase AC motor via 120v power supply.
1000 Watt 12V/24V Pure Sine Wave Inverter Charger
ATO-PI-LW1000
$641.28
Efficient 1000 Watt continuous power inverter / charger generates pure sine wave power from 12V DC or 24V DC battery bank, peak power up to 3000W. Affordable-price low frequency inverter with charger has selectable AC output voltages of 110V/120V or 220V/230V/240V, and 120V/240V split phase output also available, with protections against overload, over-temperature, low battery and overcharge, real-time LCD display, compact design and easy to install, ideal for powering most household appliances.
Isolated DC Voltage Sensor for Ripple Voltage 10mV to 1000V
ATO-VOS-RDC1000
From $134.81
DC voltage sensor is a special voltage sensor for unidirectional ripple DC voltage measurement. It has a measuring range from DC 10mV/50mV/75mV/5V/150V/300V/500V to 1000V, output signal 0-5V/0-10V/0-20mA/4-20mA, supply voltage DC 12/24V, IP20 and DIN rail installation. Isolated DC voltage transducer uses modulation and demodulation technology to achieve input/output/power supply isolation.