3 hp VFD, Single Phase 120V Input, 1ph/3ph 220V Output

$346.10
3 hp single phase 120v input, single phase and three phase 220v output variable frequency drive, specially designed for 120v power supply, manufacturer direct sale.
SKU: GK3000-SP1S1-2d2
Free Shipping
Delivery date: 6-12 days

3 hp (2.2 kW) VFD, single phase input & output, single phase to three phase, 110v-120v input, 220v-240v output.

Specification:

BasicsModelEM15-SP1S1-2d2
Capacity3 hp (2.2 kW)
Shipping weight3 kg
Dimension (W x H x D)120*205*166 mm
I/O FeatureRated current10 A
Input voltage1 phase 120V AC ±15% (Set FE-00=0)
Input frequency50Hz/60Hz
Output voltage1 phase or 3 phase 220V AC ±15%
Output frequency0~320Hz (SFC)
Control FeatureControl modeV/F control; vector control
CommunicationOffer RS485 communication interface, support MODBUS-RTU communication protocol
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humiditysmaller than 95%RH, non-condensation
Altitude≤1000m; VFD will be derated if above 1000m
VibrationLess than 5.9 m/s2 (0.6 g)
Coolingforced air cooling
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Running a 3-phase motor from single phase supply

Details

3hp VFD Single Phase 120V Input Details

If you want to connect a 3-phase motor to a single phase power supply, then you have several solutions:

  • Professional: use a VFD with single phase input and convert to 3-phase output, this is generally available for low power VFD (few horsepower).
  • Professional: apply a specially wound transformer that also mimic a 3-phase system from a single phase power supply. Expect difficulties to source and high price.
  • DIY: calculate a capacitor that will be connected between the remaining phases, such to apply it a phase shift and to mimic a 3-phase system.

Running a Three-phase Motor on a Single-phase Supply with a Frequency Converter

How to run a three phase or single phase motor with ATO VFD on 120V power supply. Take a 2 hp, single phase 120V input, single phase or three phase 220V output variable frequency drive as an example. It shows you how to wire, set parameters, commissioning VFD, run motors, etc.

VFD Programming for Stable Water Pressure in Water Supply System

A three-phase motor can be regulated using a single-phase 120V to three-phase 220V VFD, and control can be managed through terminals, as demonstrated in the following video.

Variable Frequency Drive Setting

In the video, it's demonstrated that ATO VFD offers multiple methods to adjust the frequency: Not only can you use the knob on the panel, but you can also utilize the buttons for adjustments.

Basic Troubleshooting Guide for VFD

In this video, ATO will show you the vfd basic troubleshooting guide.

How Many VFD Control Methods Do You Know?

Several methods to control the frequency of VFD:

1. Switch Button control: Use the switch signal to directly control the start and stop of the VFD (the VFD start frequency is fixed), and the multi-speed control method can be used to activate the speed of each section of the VFD.

2. Analog control: Use 5V or 0~20mA to control the frequency of the VFD, and at the same time can control the start and stop of the VFD in cooperation with the switch.

3. VFD potentiometer control: The VFD has its own potentiometer input terminal, and the VFD is directly controlled by the potentiometer.

4. Modbus-RTU control: Use RS485 interface to transmit data with Modbus-RTU protocol, which can monitor VFD, modify frequency, start and stop, etc.

5. DTU wireless remote control:Combine DTU terminal and VFD for wireless transmission. (DTU output analog quantity to control VFD frequency)

Running a Single or Three Phase Motor with a VFD on 120V Power

In this video, ATO will show you how to run a 120v variable frequency drive motor.

Running a Split-phase Motor with a 120V VFD (Terminal Control)

The ATO 120V inverter in the video can run single-phase motors/split-phase motors, three-phase motors. You can run the VFD in many ways.

Product reviews
3hp VFD question answering
5
Pilgrim
Avatar
4/5/2021 7:02 PM
Do we still need to debate VFDs when used on single phase input power like we did with the older VFDs or have you done something like beefing up the input diodes and caps so they will be able to output the same power as on 3 Ph?
Was this review helpful? Yes No (0/0)
ATO Responded
For our 1-phase To 3-phase drive, no need to oversize, we care about that in design, just consider 10% margine above rated output current referred at each model seen at our web site.
3hp VFD output voltage
5
Pence
Avatar
6/10/2021 12:16 AM
I am trying to drive a custom solenoid at variable frequency. Curious to know if the output voltage of GK3000-SP1S1-2d2 is variable.
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend to use the drive with motors only. And yes, the output voltage is variable.
What's wrong with my 3hp VFD?
5
Glack
Avatar
5/25/2022 3:29 AM
I got a problem with your drive, with a 3 phases motor the output voltage drop to 150 and without load it has 220. What's wrong?
Was this review helpful? Yes No (0/0)
ATO Responded
The problem you mentioned is probably caused by the over load current driven by the motor is huge, and then the input voltage and bus bar voltage to be low. You can try to set F0-10=60, F0-12=60, F0-17=10, F0-18=10, then rerun the VFD and test again. When the VFD is running, you can switch the shift key >>U0-03 & U0-04, to see the voltage and current output from the VFD real-time. If the VFD cannot working properly, you may need to replace a larger capacity VFD.
Is it safe to do so?
5
Diggy
Avatar
3/1/2023 8:02 PM
So I wired my AC Variable frequency drive to my single phase 220V motor,  on first start up it ran fine for about 3 or 4 min, and then the starting capacitor got hot and started to smoke, and a small mount of the oil came out of the capacitor. I believe what happened is the switch never engaged so I stayed on the start up windings. So it will run if I give it a little help getting it to spin, but that capacitor gets really hot. The centrifugal switch will not ingage until it is at about 75% rpms. And I am trying to run the motor at much slower speeds. Is it possible to bypass the centrifugal switch and the bad capacitor possibly? Is it safe to do so?
Was this review helpful? Yes No (0/0)
ATO Responded
This is a problem with the characteristics of the single-phase motor itself, so we do not recommend that the single-phase motor run for a long time at low frequency and low speed, otherwise the motor capacitor will heat up. Because the starting capacitor of the single-phase motor is only used to assist the motor to start. If the motor runs at low speed for a long time and the centrifugal switch is not disengaged, it will cause heat damage to the motor. If you want the motor to run at low frequency and low speed, we suggest you use a three-phase motor, or you can try to change the internal winding circuit of your single-phase motor to three-phase wiring and remove the capacitor.
Please give me more details of VFD
5
faye
Avatar
7/20/2023 9:05 PM
We currently have your drives installed with the motors in the attached picture. We were informed by you yesterday that these are the incorrect drives.
We are going to replace them with the drives you recommended (model EM15-SP1S1-2d2). Before we install these new drives, we would like for you to give us detailed step-by-step programming instructions.
We need this detailed info prior. Is this something you can help with?
Was this review helpful? Yes No (0/0)
ATO Responded
You can refer to our setup instructions first, and if you have other questions after receiving the goods, please contact us.
Manual: https://www.ato.com/Content/doc/110V-120V-input-VFD-user-manual.pdf
getting an error
5
Mason
Avatar
11/6/2023 11:25 PM
Hi,  I keep getting an error code 02 now when I start the motor.  Can you get any ideas how to fix this?
Was this review helpful? Yes No (0/0)
ATO Responded
Please follow the steps below to troubleshoot and provide us with feedback:
1. Since your motor has dual voltage 230V/460V, please confirm that your motor wiring is based on low voltage 230V.
2. Please check whether the VFD input voltage is 120VAC?
3. Please tell us what parameters are set in the VFD, especially whether the parameters F1-01~F1-04 are set according to the motor nameplate?
4. Please confirm that the VFD and motor are connected correctly and set the correct parameters, then run the VFD again and provide us with a start-up video for confirmation
get error code
5
Dylan
Avatar
11/7/2023 12:17 AM
I get error code 40 now I went through all the setting and made sure they were right.  Now I get a error 0040 .
Was this review helpful? Yes No (0/0)
ATO Responded
VFD displays error code 40, which means The load is too heavy or locked- rotor occurs on the motor. Also, The frequency inverter model is of too small power class. If the VFD can run normally after removing the motor, it means that your motor load is too heavy and the VFD is overloaded. We recommend that you replace it with a VFD with a 5HP capacity.
I want to know that...
5
Cyril
Avatar
1/8/2024 7:53 PM
I was able to connect VFD to my controller successfully though is it possible to signal back to my controller if there is an error.

Also I’d like to add a breaking resistor to it though I couldn’t find anything in the manual about that.

How do I determine the resistance that I need for the breaking resistor?
Was this review helpful? Yes No (0/0)
ATO Responded
The braking resistor used in this VFD model EM15-SP1S1-2d2 is 100w/70Ω.

The braking resistor is connected to the P+/PB terminal.
Practical VFD
5
Jimmyy
Avatar
6/16/2024 8:51 PM
This single-phase VFD has quite complete functions. Anyway, I am looking for a wiring diagram to hook up an external potentiometer to control motor speed.
Was this review helpful? Yes No (0/0)
ATO Responded
You can externally connect a potentiometer with a resistance of 4.7K~10KΩ and a power of 2W-10W. Please refer to the wiring diagram on page 8 of the user manual. The potentiometer is connected to AI1, 10V, and GND, and just set F0-03=2.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

3 hp (2.2 kW) VFD, single phase input & output, single phase to three phase, 110v-120v input, 220v-240v output.

Specification:

BasicsModelEM15-SP1S1-2d2
Capacity3 hp (2.2 kW)
Shipping weight3 kg
Dimension (W x H x D)120*205*166 mm
I/O FeatureRated current10 A
Input voltage1 phase 120V AC ±15% (Set FE-00=0)
Input frequency50Hz/60Hz
Output voltage1 phase or 3 phase 220V AC ±15%
Output frequency0~320Hz (SFC)
Control FeatureControl modeV/F control; vector control
CommunicationOffer RS485 communication interface, support MODBUS-RTU communication protocol
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humiditysmaller than 95%RH, non-condensation
Altitude≤1000m; VFD will be derated if above 1000m
VibrationLess than 5.9 m/s2 (0.6 g)
Coolingforced air cooling
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Running a 3-phase motor from single phase supply

Details

3hp VFD Single Phase 120V Input Details

If you want to connect a 3-phase motor to a single phase power supply, then you have several solutions:

  • Professional: use a VFD with single phase input and convert to 3-phase output, this is generally available for low power VFD (few horsepower).
  • Professional: apply a specially wound transformer that also mimic a 3-phase system from a single phase power supply. Expect difficulties to source and high price.
  • DIY: calculate a capacitor that will be connected between the remaining phases, such to apply it a phase shift and to mimic a 3-phase system.

Product reviews
3hp VFD question answering
5
Pilgrim
Avatar
4/5/2021 7:02 PM
Do we still need to debate VFDs when used on single phase input power like we did with the older VFDs or have you done something like beefing up the input diodes and caps so they will be able to output the same power as on 3 Ph?
Was this review helpful? Yes No (0/0)
ATO Responded
For our 1-phase To 3-phase drive, no need to oversize, we care about that in design, just consider 10% margine above rated output current referred at each model seen at our web site.
3hp VFD output voltage
5
Pence
Avatar
6/10/2021 12:16 AM
I am trying to drive a custom solenoid at variable frequency. Curious to know if the output voltage of GK3000-SP1S1-2d2 is variable.
Was this review helpful? Yes No (0/0)
ATO Responded
We recommend to use the drive with motors only. And yes, the output voltage is variable.
What's wrong with my 3hp VFD?
5
Glack
Avatar
5/25/2022 3:29 AM
I got a problem with your drive, with a 3 phases motor the output voltage drop to 150 and without load it has 220. What's wrong?
Was this review helpful? Yes No (0/0)
ATO Responded
The problem you mentioned is probably caused by the over load current driven by the motor is huge, and then the input voltage and bus bar voltage to be low. You can try to set F0-10=60, F0-12=60, F0-17=10, F0-18=10, then rerun the VFD and test again. When the VFD is running, you can switch the shift key >>U0-03 & U0-04, to see the voltage and current output from the VFD real-time. If the VFD cannot working properly, you may need to replace a larger capacity VFD.
Is it safe to do so?
5
Diggy
Avatar
3/1/2023 8:02 PM
So I wired my AC Variable frequency drive to my single phase 220V motor,  on first start up it ran fine for about 3 or 4 min, and then the starting capacitor got hot and started to smoke, and a small mount of the oil came out of the capacitor. I believe what happened is the switch never engaged so I stayed on the start up windings. So it will run if I give it a little help getting it to spin, but that capacitor gets really hot. The centrifugal switch will not ingage until it is at about 75% rpms. And I am trying to run the motor at much slower speeds. Is it possible to bypass the centrifugal switch and the bad capacitor possibly? Is it safe to do so?
Was this review helpful? Yes No (0/0)
ATO Responded
This is a problem with the characteristics of the single-phase motor itself, so we do not recommend that the single-phase motor run for a long time at low frequency and low speed, otherwise the motor capacitor will heat up. Because the starting capacitor of the single-phase motor is only used to assist the motor to start. If the motor runs at low speed for a long time and the centrifugal switch is not disengaged, it will cause heat damage to the motor. If you want the motor to run at low frequency and low speed, we suggest you use a three-phase motor, or you can try to change the internal winding circuit of your single-phase motor to three-phase wiring and remove the capacitor.
Please give me more details of VFD
5
faye
Avatar
7/20/2023 9:05 PM
We currently have your drives installed with the motors in the attached picture. We were informed by you yesterday that these are the incorrect drives.
We are going to replace them with the drives you recommended (model EM15-SP1S1-2d2). Before we install these new drives, we would like for you to give us detailed step-by-step programming instructions.
We need this detailed info prior. Is this something you can help with?
Was this review helpful? Yes No (0/0)
ATO Responded
You can refer to our setup instructions first, and if you have other questions after receiving the goods, please contact us.
Manual: https://www.ato.com/Content/doc/110V-120V-input-VFD-user-manual.pdf
getting an error
5
Mason
Avatar
11/6/2023 11:25 PM
Hi,  I keep getting an error code 02 now when I start the motor.  Can you get any ideas how to fix this?
Was this review helpful? Yes No (0/0)
ATO Responded
Please follow the steps below to troubleshoot and provide us with feedback:
1. Since your motor has dual voltage 230V/460V, please confirm that your motor wiring is based on low voltage 230V.
2. Please check whether the VFD input voltage is 120VAC?
3. Please tell us what parameters are set in the VFD, especially whether the parameters F1-01~F1-04 are set according to the motor nameplate?
4. Please confirm that the VFD and motor are connected correctly and set the correct parameters, then run the VFD again and provide us with a start-up video for confirmation
get error code
5
Dylan
Avatar
11/7/2023 12:17 AM
I get error code 40 now I went through all the setting and made sure they were right.  Now I get a error 0040 .
Was this review helpful? Yes No (0/0)
ATO Responded
VFD displays error code 40, which means The load is too heavy or locked- rotor occurs on the motor. Also, The frequency inverter model is of too small power class. If the VFD can run normally after removing the motor, it means that your motor load is too heavy and the VFD is overloaded. We recommend that you replace it with a VFD with a 5HP capacity.
I want to know that...
5
Cyril
Avatar
1/8/2024 7:53 PM
I was able to connect VFD to my controller successfully though is it possible to signal back to my controller if there is an error.

Also I’d like to add a breaking resistor to it though I couldn’t find anything in the manual about that.

How do I determine the resistance that I need for the breaking resistor?
Was this review helpful? Yes No (0/0)
ATO Responded
The braking resistor used in this VFD model EM15-SP1S1-2d2 is 100w/70Ω.

The braking resistor is connected to the P+/PB terminal.
Practical VFD
5
Jimmyy
Avatar
6/16/2024 8:51 PM
This single-phase VFD has quite complete functions. Anyway, I am looking for a wiring diagram to hook up an external potentiometer to control motor speed.
Was this review helpful? Yes No (0/0)
ATO Responded
You can externally connect a potentiometer with a resistance of 4.7K~10KΩ and a power of 2W-10W. Please refer to the wiring diagram on page 8 of the user manual. The potentiometer is connected to AI1, 10V, and GND, and just set F0-03=2.
Only registered users can write reviews
Customers who bought this item also bought

3 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0022
$238.14
Low price 3hp VFD, convert 220V/230V/240V 1 phase to 3 phase, 9.6 amps, RS485 enabled, shipping weight 3kg, manufacturer direct sale.

5 hp VFD, Single Phase to Three Phase VFD

GK3000-2S0037
$294.31
5hp variable frequency drive, single phase to three phase VFD, 17 amps, RS485 enabled, shipping weight 4kg, manufacturer direct sale.

2 hp VFD, Single Phase 120V Input, 1ph/3ph 220V Output

GK3000-SP1S1-1d5
$315.38
Affordable 2 hp variable frequency drive, single phase 110v-120v input, single phase and three phase 220v-240v output, designed for driving single/three phase AC motor via 120v power supply.

1000 Watt 12V/24V Pure Sine Wave Inverter Charger

ATO-PI-LW1000
$641.28
Efficient 1000 Watt continuous power inverter / charger generates pure sine wave power from 12V DC or 24V DC battery bank, peak power up to 3000W. Affordable-price low frequency inverter with charger has selectable AC output voltages of 110V/120V or 220V/230V/240V, and 120V/240V split phase output also available, with protections against overload, over-temperature, low battery and overcharge, real-time LCD display, compact design and easy to install, ideal for powering most household appliances.

Isolated DC Voltage Sensor for Ripple Voltage 10mV to 1000V

ATO-VOS-RDC1000
From $134.81
DC voltage sensor is a special voltage sensor for unidirectional ripple DC voltage measurement. It has a measuring range from DC 10mV/50mV/75mV/5V/150V/300V/500V to 1000V, output signal 0-5V/0-10V/0-20mA/4-20mA, supply voltage DC 12/24V, IP20 and DIN rail installation. Isolated DC voltage transducer uses modulation and demodulation technology to achieve input/output/power supply isolation.