15 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

$1,587.36
Customized 15 hp VFD at best price, with single phase 220v/ 230v/ 240v input, three phase 380v/ 400v/ 415v output. Using it as frequency converter to control AC motor speed.
SKU: GK3000-CS0110G
*
Free Shipping
Delivery date: 6-12 days

15 hp (11 kW) variable frequency drive, 1-phase 220v to 3-phase 380v VFD, 25 amps, IP20, RS485 enabled.

Specification:

BasicsModelGK3000-CS0110G
Capacity15 hp (11 kW)
Shipping weight8 kg
Dimension330*200*200 mm
Installation size316*188 mm
I/O FeatureRated current25 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage (Optional)3 phase AC 380V/ 400V/ 415V/ 440V/ 460V (Note: 440V, 460V output voltage only for the 1-phase 240V input VFD)
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Single phase 220V to three phase 380V VFD features

Product features

1-phase 220V input to 3-phase 380V output VFD adopts AC-DC circuit structure and uses SPWM modulation control technology to convert ordinary 1-phase 220V power to industrial 3-phase 380V power. It is suitable for 3-phase asynchronous motors with an output phase angle of 120°, which fully satisfies the motor use standard and is suitable for all types of motor loads. The single phase to three phase VFD solves the inconvenience of production in some areas due to 3-phase power restrictions, and also solves the needs of some users who cannot apply to 3-phase power due to site restrictions.

Technical features

  1. Ordinary utility 220V input, eliminating the cumbersome procedures of applying for 3-phase power and various labor costs and various hidden costs.
  2. The output uses industrial 3-phase power, but is billed according to the civilian 1-phase power, which is economical.
  3. Core components are imported devices, stable performance, long service life.
  4. Safe and reliable, the input 1-phase power and output 3-phase power completely electrical isolation.
  5. Input wide voltage range design, to adapt to the work environment of the general low utility voltage in various regions.
  6. Output protection function is perfect, there are over-voltage, overload, over temperature, short circuit, over current and other kinds of protection.

In this video, ATO will show you the vfd basic troubleshooting guide.

4-20mA speed control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
VFD products recommended by ATO
5
Dcarbajal
Avatar
7/27/2021 9:12 PM
I need a VFD recommendation. I have a 3 phase motor. I need to run off of 220v single phase and the motor name plate is listed as follows 1725 rpm 208-230/460 6.0/3.0 amps 60 hertz 2 HP. What do your recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, based on your motor specs, recommended drive model: GK3000-2S0022, 3hp capacity.
How to use VFD?
5
Cookster
Avatar
10/8/2021 12:30 AM
For my application I need to have maximal torque (that is why I chose to run in senseless vector control mode ). What settings do I need to get the maximum torque at low RPM for your 1-phase drives?
Was this review helpful? Yes No (0/0)
ATO Responded
Our 1-phase driver is not suitable for running a single-phase motor under low speed and low voltage, which will lead to heating of single-phase motor. Generally, we suggest that the starting frequency should be set above 40Hz.
What is the correct way to ground the VFD?
5
antony
Avatar
7/20/2023 12:23 AM
I recently purchased a GK3000-CS0110G and I'm wondering what's the correct way to ground the unit.
The main earthing circuit terminal is not electrically connected to the earth plate at the back of the unit or to the PE grounding terminal on C2 terminal block on the PCB.
I would have expected all three to be electrically connected. Is this a defect? If not a defect, what is the correct way to ground the unit?
Was this review helpful? Yes No (0/0)
ATO Responded
Regarding the correct grounding of the VFD, the grounding cable at the PE end must not borrow the grounding wire of other equipment and must be directly connected to the grounding plate.
The PE grounding terminal is mainly to prevent the internal leakage current of the VFD and is not directly connected to the internal PCB board. This grounding design is not questionable.
You just need to connect the VFDs and motor's grounds individually to the grounding panel.
Hope my explanation is able to assist you. Please feel free to let us know if you have any further questions.
Why we are getting this error code?
5
alfor
Avatar
11/7/2023 11:27 PM
We recently hooked up 2 machines, and they are throwing error codes E26.
we took a single phase 208V 25A and a single phase 208V 45A circuit to the one that calls for it. We don’t understand why we are getting this error code.
Was this review helpful? Yes No (0/0)
ATO Responded
E26 is a current limit fault code.
First, we want to confirm whether the E26 code displayed by the VFD occurs when the motor is connected and running, or whether the VFD appears when running the VFD without load.
Please confirm whether the VFD can display normally and start normally if it is powered alone.
Note: For the 1-Phase 220V to 3-Phase 380V VFD you purchased, the input side current capacity of the VFD is required to be 2.5 times the rated output current of the VFD.
This means that the single-phase 208V 25A and single-phase 208V 45A circuits you are using do Not have enough capacity.
You must use a single-phase 208V circuit: 25A*2.5=62.5A, and 45A*2.5=112A.
Used to power CNC Spindle
5
Alice
Avatar
11/22/2023 11:02 AM
Used one of these to power my 380V CNC spindle with variable speed controlled by the CNC computer via VI 0-10V signal on SVC. So far so good. Good when you have an imported machine that was wired for 380V three phase. Customer service was helpful as well.
Was this review helpful? Yes No (0/0)
Do you have a wiring schematic?
5
Luke
Avatar
11/26/2023 8:01 PM
Now we have taken: single-phase 208V circuit: 25A*2.5=62.5A, and 45A*2.5=112A
The ampacity is higher, but now its reading 760 Volts, Not 380 Volts like it was.
Do you have a wiring schematic? Or do you know what is causing the higher voltage to occur?
Was this review helpful? Yes No (0/0)
ATO Responded
We do not think that the VFD input voltage will be 220V and the output voltage will reach 760V.  Could you use a multimeter to measure the actual voltage at the VFD input/output terminals and provide us with photos of the measurement readings for further confirmation? Of course, it would be better if you could provide a video of the measurement. You can send us the large video file via wetransfer.com.

Regarding the wiring of the VFD, the 220V input voltage is connected to the R-T terminal (the terminal S with the screw removed is not used), and the U, V, and W terminals are connected to the three-phase motor.
we have a new error code
5
Owens
Avatar
11/28/2023 6:32 PM
Now we have a new error code. E-01. Can you please give some direction on how to fix that?
Was this review helpful? Yes No (0/0)
ATO Responded
E-01 error code is VFD overcurrent protection, indicating that the motor is heavily loaded. Does this fault occur when the VFD is started or does it occur occasionally during operation? You can try to modify the acceleration and deceleration time P0.12=P0.13=20, P5.00=2 or 3 (V/F curve setting). If you still have problems, please provide us with a picture of the motor nameplate and a video for further confirmation.  You can send us the large video file via wetransfer.com.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

15 hp (11 kW) variable frequency drive, 1-phase 220v to 3-phase 380v VFD, 25 amps, IP20, RS485 enabled.

Specification:

BasicsModelGK3000-CS0110G
Capacity15 hp (11 kW)
Shipping weight8 kg
Dimension330*200*200 mm
Installation size316*188 mm
I/O FeatureRated current25 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage (Optional)3 phase AC 380V/ 400V/ 415V/ 440V/ 460V (Note: 440V, 460V output voltage only for the 1-phase 240V input VFD)
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Tips: Single phase 220V to three phase 380V VFD features

Product features

1-phase 220V input to 3-phase 380V output VFD adopts AC-DC circuit structure and uses SPWM modulation control technology to convert ordinary 1-phase 220V power to industrial 3-phase 380V power. It is suitable for 3-phase asynchronous motors with an output phase angle of 120°, which fully satisfies the motor use standard and is suitable for all types of motor loads. The single phase to three phase VFD solves the inconvenience of production in some areas due to 3-phase power restrictions, and also solves the needs of some users who cannot apply to 3-phase power due to site restrictions.

Technical features

  1. Ordinary utility 220V input, eliminating the cumbersome procedures of applying for 3-phase power and various labor costs and various hidden costs.
  2. The output uses industrial 3-phase power, but is billed according to the civilian 1-phase power, which is economical.
  3. Core components are imported devices, stable performance, long service life.
  4. Safe and reliable, the input 1-phase power and output 3-phase power completely electrical isolation.
  5. Input wide voltage range design, to adapt to the work environment of the general low utility voltage in various regions.
  6. Output protection function is perfect, there are over-voltage, overload, over temperature, short circuit, over current and other kinds of protection.
Product reviews
VFD products recommended by ATO
5
Dcarbajal
Avatar
7/27/2021 9:12 PM
I need a VFD recommendation. I have a 3 phase motor. I need to run off of 220v single phase and the motor name plate is listed as follows 1725 rpm 208-230/460 6.0/3.0 amps 60 hertz 2 HP. What do your recommend?
Was this review helpful? Yes No (0/0)
ATO Responded
Ok, based on your motor specs, recommended drive model: GK3000-2S0022, 3hp capacity.
How to use VFD?
5
Cookster
Avatar
10/8/2021 12:30 AM
For my application I need to have maximal torque (that is why I chose to run in senseless vector control mode ). What settings do I need to get the maximum torque at low RPM for your 1-phase drives?
Was this review helpful? Yes No (0/0)
ATO Responded
Our 1-phase driver is not suitable for running a single-phase motor under low speed and low voltage, which will lead to heating of single-phase motor. Generally, we suggest that the starting frequency should be set above 40Hz.
What is the correct way to ground the VFD?
5
antony
Avatar
7/20/2023 12:23 AM
I recently purchased a GK3000-CS0110G and I'm wondering what's the correct way to ground the unit.
The main earthing circuit terminal is not electrically connected to the earth plate at the back of the unit or to the PE grounding terminal on C2 terminal block on the PCB.
I would have expected all three to be electrically connected. Is this a defect? If not a defect, what is the correct way to ground the unit?
Was this review helpful? Yes No (0/0)
ATO Responded
Regarding the correct grounding of the VFD, the grounding cable at the PE end must not borrow the grounding wire of other equipment and must be directly connected to the grounding plate.
The PE grounding terminal is mainly to prevent the internal leakage current of the VFD and is not directly connected to the internal PCB board. This grounding design is not questionable.
You just need to connect the VFDs and motor's grounds individually to the grounding panel.
Hope my explanation is able to assist you. Please feel free to let us know if you have any further questions.
Why we are getting this error code?
5
alfor
Avatar
11/7/2023 11:27 PM
We recently hooked up 2 machines, and they are throwing error codes E26.
we took a single phase 208V 25A and a single phase 208V 45A circuit to the one that calls for it. We don’t understand why we are getting this error code.
Was this review helpful? Yes No (0/0)
ATO Responded
E26 is a current limit fault code.
First, we want to confirm whether the E26 code displayed by the VFD occurs when the motor is connected and running, or whether the VFD appears when running the VFD without load.
Please confirm whether the VFD can display normally and start normally if it is powered alone.
Note: For the 1-Phase 220V to 3-Phase 380V VFD you purchased, the input side current capacity of the VFD is required to be 2.5 times the rated output current of the VFD.
This means that the single-phase 208V 25A and single-phase 208V 45A circuits you are using do Not have enough capacity.
You must use a single-phase 208V circuit: 25A*2.5=62.5A, and 45A*2.5=112A.
Used to power CNC Spindle
5
Alice
Avatar
11/22/2023 11:02 AM
Used one of these to power my 380V CNC spindle with variable speed controlled by the CNC computer via VI 0-10V signal on SVC. So far so good. Good when you have an imported machine that was wired for 380V three phase. Customer service was helpful as well.
Was this review helpful? Yes No (0/0)
Do you have a wiring schematic?
5
Luke
Avatar
11/26/2023 8:01 PM
Now we have taken: single-phase 208V circuit: 25A*2.5=62.5A, and 45A*2.5=112A
The ampacity is higher, but now its reading 760 Volts, Not 380 Volts like it was.
Do you have a wiring schematic? Or do you know what is causing the higher voltage to occur?
Was this review helpful? Yes No (0/0)
ATO Responded
We do not think that the VFD input voltage will be 220V and the output voltage will reach 760V.  Could you use a multimeter to measure the actual voltage at the VFD input/output terminals and provide us with photos of the measurement readings for further confirmation? Of course, it would be better if you could provide a video of the measurement. You can send us the large video file via wetransfer.com.

Regarding the wiring of the VFD, the 220V input voltage is connected to the R-T terminal (the terminal S with the screw removed is not used), and the U, V, and W terminals are connected to the three-phase motor.
we have a new error code
5
Owens
Avatar
11/28/2023 6:32 PM
Now we have a new error code. E-01. Can you please give some direction on how to fix that?
Was this review helpful? Yes No (0/0)
ATO Responded
E-01 error code is VFD overcurrent protection, indicating that the motor is heavily loaded. Does this fault occur when the VFD is started or does it occur occasionally during operation? You can try to modify the acceleration and deceleration time P0.12=P0.13=20, P5.00=2 or 3 (V/F curve setting). If you still have problems, please provide us with a picture of the motor nameplate and a video for further confirmation.  You can send us the large video file via wetransfer.com.
Only registered users can write reviews
Customers who bought this item also bought

30 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

GK3000-CS0220G
$2,455.97
30 hp VFD for sales, converts 1-phase 220V input to 3-phase 380V output, 45A rated current, 50Hz/ 60Hz input frequency, 0-400Hz output frequency. It can be used as a motor speed controller and a frequency inverter.

Custom Order

ATO-CUSTOM
Pay for custom orders, or extra amount of existing orders.
Indicate the item specification you pay for, and specify PI / PO number if you have.

7.5 kW Air Cooled CNC Spindle Motor, 18000 rpm, ER32

ATO-SPINDLE-A7500
$1,076.92
7.5 kW air cooled spindle motor for sales, it features 18000 rpm high speed, 3.58 Nm torque, ER32 collet, 3 phase 380V AC at 300Hz, high quality 4pcs bearings, IP50 for protection grade, used in CNC drilling and milling equipment.

1 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

GK3000-CS0007
$309.15
1 hp VFD for sale at cheap price, with 1-phase 220v input to 3-phase 380v output. 50Hz/ 60Hz input frequency, 2.1 amps rated current, RS485 enabled.

10 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

GK3000-CS0075G
$1,095.67
Affordable price 10 hp (7.5 kW) VFD, converts 220v/ 230v /240v 1 phase input to 380v/ 400v/ 415v 3 phase output, 17 amps, V/F and sensorless vector control.