20 hp (15 kW) variable frequency drive, single phase 220v/230v/240v input, three phase output, 60 amps.
Specification:
| Basics | Model | GK3000-2S0150G |
| Capacity | 20 hp (15 kW) | |
| Shipping weight | 23 kg | |
| Dimension | 530*320*235 mm | |
| I/O Feature | Rated current | 60A |
| Input voltage | 1 phase 220~240V AC | |
| Input frequency | 50Hz/ 60Hz | |
| Output voltage | 3 phase AC 0~input voltage | |
| Output frequency | 0Hz~1000Hz | |
| Over load capacity | 150% of rated current for 1 minute, 180% of rated current for 3 seconds | |
| Control Feature | Control mode | V/F, Sensorless vector control (SVC), Speed sensor vector control (FVC) |
| Communication | RS485 | |
| Speed regulation | 1:100 | |
| Start torque | 150% of rating torque at 1 Hz | |
| Speed control accuracy | ≤±0.5% of rating synchronous speed | |
| Frequency precision | Digital setting: max frequency x± 0.01%; Analog setting: max frequency x± 0.2% | |
| Frequency resolution | Analog setting: 0.1% of max frequency; Digital setting: 0.01Hz | |
| Torque boost | Automatic torque boost, manual torque boost 0.1%~30.0% | |
| Interior PID controller | Be convenient to make closed-loop system | |
| Automatic energy save running | Optimize V/F curve automatically based on the load to realize power save running | |
| Automatic voltage regulation (AVR) | Can keep constant output voltage when power source voltage varies. | |
| Automatic current limiting | Limit running current automatically to avoid frequent over-current which will cause trip | |
| Environment | Enclosure rating | IP 20 |
| Temperature | –10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5% | |
| Humidity | 5%-95%, without condensation | |
| Altitude | ≤1000m; VFD will be derated if above 1000m | |
| Impingement and oscillation | Normal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g) | |
| Store environment | –20℃~ +60℃; no dust, no corrosive gas, no direct sunlight |
Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.
Tips: What will the output torque be when the motor’s rotating speed changes?
Starting torque and maximum torque under the driving of VFD are smaller than those directly driven by power supply.
When the motor is powered by a power frequency supply, the starting and acceleration impact are huge. When the motor is powered by a VFD, the impact would be much weaker. Power frequency starting would produce a huge starting current. When a VFD is used, the output voltage and frequency of VFD are gradually added to the motor, so the starting current impact would be much smaller.
It looks like P9.14 is where the password for the configuration is configured.
Is this correct?
Also, is there a setting that will disable the potentiometer on the display panel?
We want the running frequency to be locked to 60 hertz always.
I am assuming that I can set P0.01 to anything other than 0 or 1 to accomplish this, but I am not sure.
See attached specs on Air Compressor. The shore power or generator power supply is 220V single phase and we purchased the VFD to convert that [power to 208V 3 phase power for the air compressor.
The air compressor manufacturer is telling us they need 42 amps to run the compressor but 80 amps at start-up.
Is there a way to program and “delay” in the VFD to give it 5-10 seconds to start air compressor?
That is what the compressor people are telling me.
Also, this VFD only registers 50hz. It’s supposed to be 60hz correct?
Please advise.