1 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

$309.15
1 hp VFD for sale at cheap price, with 1-phase 220v input to 3-phase 380v output. 50Hz/ 60Hz input frequency, 2.1 amps rated current, RS485 enabled.
SKU: GK3000-CS0007
*
Free Shipping
Delivery date: 6-12 days

Best 1 hp (0.75 kW) variable frequency drive, single phase 220v to three phase 380v VFD for AC motor speed control, 400v/ 415v output for choice.

Specification:

BasicsModelGK3000-CS0007
Capacity1 hp (0.75 kW)
Shipping weight3 kg
Dimension236*130*176 mm
Installation size222*116 mm
I/O FeatureRated current2.1 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage (Optional)3 phase AC 380V/ 400V/ 415V/ 440V/ 460V (Note: 440V, 460V output voltage only for the 1-phase 240V input VFD)
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

750W Three Phase VFD Details

Tips: Why you need a 1-phase 220V to 3-phase 380V VFD?

Due to national policies and regional restrictions, many areas will now withdraw 3-phase 380V industrial power. No 3-phase power in the region to apply for 3-phase power cumbersome procedures and a variety of labor costs and various hidden costs, resulting in some areas can not use industrial 380V power. and general industrial equipment, such as AC motors are mostly 3-phase 380V, in the absence of 3-phase electricity can not run. We can only find ways to convert 1-phase 220V to 3-phase 380V. However, many single phase 220V to three phase 380V equipment on the market are ridiculously expensive, so many users in need are discouraged. And the original machine can only be temporarily placed, or put into other places with industrial electricity to use.

ATO offers a series of 1-phase 220V input to 3-phase 380V output variable frequency drive from 1hp to 20 hp, which can drive 3-phase asynchronous motor soft start operation, for infinitely adjustable speed. The input power only needs single phase 220V, output three phase 380V, and the price is acceptable to most users. Our VFDs are about 1/10 of the price of the booster on the market, compact size, powerful, 0-400Hz can be adjusted at will, completely solve the embarrassing situation of industrial equipment without 3-phase power.

In this video, ATO will show you the vfd basic troubleshooting guide.

4-20mA speed control on VFD

4-20mA is as common in analog control systems as 0~10V, and ATO GK3000 series VFDs are also perfectly compatible.

Product reviews
1hp VFD protection method
5
Cliffy
Avatar
4/22/2021 11:41 PM
Protection between 1hp VFD and motor: Could you please tell me quickly why you don't recommend any EMC filters, shielded wires and braking module/transistor?
Was this review helpful? Yes No (0/0)
ATO Responded
Don't recommend anything between 1hp VFD and motor, because motor will be directly controller "on/off/speed, etc" via the VFD.
The scope of use of 1-phase 1hp VFD
5
Cody
Avatar
7/28/2021 9:14 PM
Will your 1hp, 1-phase, 220V drive work for 100-200W motor?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course, it works.
Can ATO help me find a suitable VFD?
5
Bertinazzi
Avatar
9/9/2021 12:24 AM
We are looking for a single phase 5hp frequency drive 120 volt input to 3 phase 230 volt output 230 volt 60 Hz for a dive compressor application and we are wondering if this is where you can help us with?
The unit needs to be able to start through an external source in this case the dive compressor and then we are looking for and programmable output for a 120 volt drain valve 10 watts. ideally when the unit starts up, it will energize for about 7 seconds, so the drain solenoid will open and vent while the motor is getting to full speed. Then de-energize for 10 minutes for about 7 seconds and just repeat while the motor is running. If not, can we use the output relay to activate a cycling timer relay?
Was this review helpful? Yes No (0/0)
ATO Responded
SKU: GK3000-SP1S1-004
Our VFD supports single-phase 120V input, and the output voltage is three-phase 220V.
However, this voltage should not affect the 230V motor much, so you can use it normally.
If you can provide your submersible compressor power, voltage, current and other parameters for our reference, it would be better. The rated current capacity of VFD should be larger than your motor rated current.
For the cyclic control requirements you mention below, you can only program them yourself or use the cyclic timer relay.
Please let me know what information you can provide about this series?
5
Pasadas
Avatar
11/21/2021 10:52 PM
Hello, I am interested in more information about the GK3300 series of VFD drives, non-enclosed. Could you provide a manual for this series? I found a manual for the GK3000 series and imagine many things are similar. However, the main thing I wonder is how they are set up since it looks like there is no control readout, buttons or other manual inputs. Is this done with a configuration software maybe? Please let me know what info you can provide regarding this series!
Was this review helpful? Yes No (0/0)
ATO Responded
If you purchase the VFD non-enclosed, it will be equipped with a keyboard to realize input and display the reading function.
Can I increase torque though parameter settings?
5
Tom
Avatar
9/9/2022 2:57 AM
A 3ph 1hp GP ind. motor is used to install the GK3000 to a small wood lathe. The torque feels insufficient. Is it possible to enhance torque using parameter settings? My motor is a 2-pole (per the specs), but I changed the pole parameter to a 4-pole setting, and the torque seemed to increase. Is this a bad idea?
Was this review helpful? Yes No (0/0)
ATO Responded
By adjusting parameter P0.09 to 4% or 6%, you can increase the torque. You might as well return the motor to 2-pole operation at the same time.
I can't find the perimeters on the manual
5
Keran
Avatar
3/21/2023 7:29 PM
I have a VFD model and could use some help on setting the perimeters on the VFD to make it run controlled from a pressure switch to an air compressor. I have the pressure switch connected to COM and FWD terminals, just can't find the perimeters on the manual to set it to run being controlled by the pressure switch.
Was this review helpful? Yes No (0/0)
ATO Responded
Is your compressor pressure switch similar to a button switch with a normally open contact (NO)? If yes, you can use this pressure switch, connect to FWD-COM terminal. Please refer to the settings as follows:
P0.03=1 (run command from terminal)
P4.08=0 (2-wire control mode 1)
P4.00=13 (Define terminal X1 as stop signal)
When your pressure switch is activated, the normally open contact is closed, and the FWD-COM is connected, the VFD will start running. When you press Emergency stop, X1 and COM will be connected, and VFD will stop.
We should control VFD by modbus communication only?
5
Betty
Avatar
6/7/2023 2:58 AM
Thank you for your support.
So you are saying we should control VFD by MODBUS communication only?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, VFD can only be controlled via MODBUS communication.
Is there any video on how to change the VFD parameters?
5
avery
Avatar
7/17/2023 3:41 AM
I bought a VFD from you.
Is there any video on how to change the parameters?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Please provide us with the order number to further confirm what product you purchased.
We hope to provide you with better service.
2. Please refer to the link settings: https://www.youtube.com/@ATOcom/playlists
Can you give advice to solve VFD problem?
5
abner
Avatar
7/25/2023 9:45 PM
Hello! I purchased a gk3000 that went through wiring, and programming, and the milling machine ran.
However, on the endmill cutter, I didn’t seem to be receiving the correct power as well as at a certain point it shut all power to the house down without flipping the breakers within the panel.

I’m going to assume on the machine side some of the programming may be incorrect as I followed the YouTube videos and plugged my motor information as best I could. In any case, I have it switched off at the breaker now and am advantageous to restart because I can not lose power to the house.

I spoke to a mechanical electrician as this transgressed and he was baffled as well.
Any direction, or advice?
Would be greatly appreciated.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Please provide us with the order number to further confirm what product you purchased.
We hope to provide you with better service.

2. Our VFD cannot be used as a power source, it needs to be directly connected to the motor.
Please provide us with your motor nameplate picture for further confirmation.
Which is correct for VFD answer?
5
ritchie
Avatar
8/29/2023 3:38 AM
One of the questions asked about this VFD was whether it maintained the motor within its torque capability at a reduced frequency. The answer was no.
However, the manual indicates that the VFD operates in linear V/F mode only, which would be constant torque below the motor's base speed and constant hp above.
My question is, which is correct? Can the VFD maintain the motor at near 100% rated torque down to at least 80% of its base speed? Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
When the frequency and speed of a single-phase motor are reduced, the output torque will also drop, and the torque cannot be maintained.
The V/F curve operation mode described in our manual is based on the research of three-phase motors, single-phase motors have not been tested.
I have a question about writing to 0x6000
4
Ives
Avatar
9/19/2024 12:07 AM
I have a question about writing to 0x6000. I’m getting a failure, illegal data value when I try to write a 1. My question, are writes to 0x6000, the command registers limited if pc.03 (command source) is not set to 2 (terminal). I’m just testing at this point and don’t want to interfere otherwise with the VFD so pc.03 is at 0.
Was this review helpful? Yes No (0/0)
ATO Responded
Please read the RS485 communication protocol description carefully. Please read the RS485 communication protocol section of the manual carefully again (Chapter 9), see on: https://www.ato.com/Content/doc/gk3000-variable-frequency-drive-user-manual.pdf
In the communication description section, address 0x6000 is the address of the VFD control parameter group, which can only be read but Not written. Then of course there will be errors when you write.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Best 1 hp (0.75 kW) variable frequency drive, single phase 220v to three phase 380v VFD for AC motor speed control, 400v/ 415v output for choice.

Specification:

BasicsModelGK3000-CS0007
Capacity1 hp (0.75 kW)
Shipping weight3 kg
Dimension236*130*176 mm
Installation size222*116 mm
I/O FeatureRated current2.1 A
Input voltage1 phase 220~240V AC
Input frequency50Hz/ 60Hz
Output voltage (Optional)3 phase AC 380V/ 400V/ 415V/ 440V/ 460V (Note: 440V, 460V output voltage only for the 1-phase 240V input VFD)
Output frequency0Hz~1000Hz
Over load capacity150% of rated current for 1 minute, 180% of rated current for 3 seconds
Control FeatureControl modeV/F control;
Sensorless vector control;
CommunicationRS485
Speed regulation1:100
Start torque150% of rating torque at 1 Hz
Speed control accuracy≤±0.5% of rating synchronous speed
Frequency precisionDigital setting: max frequency x± 0.01%;
Analog setting: max frequency x± 0.2%
Frequency resolutionAnalog setting: 0.1% of max frequency;
Digital setting: 0.01Hz
Torque boostAutomatic torque boost, manual torque boost 0.1%~30.0%
Interior PID controllerBe convenient to make closed-loop system
Automatic energy save runningOptimize V/F curve automatically based on the load to realize power save running
Automatic voltage regulation (AVR)Can keep constant output voltage when power source voltage varies.
Automatic current limitingLimit running current automatically to avoid frequent over-current which will cause trip
EnvironmentEnclosure ratingIP 20
Temperature–10℃~ +40℃; VFD will be derated if ambient temperature exceed 40℃; each rise 1℃, the derate will be 5%
Humidity5%-95%, without condensation
Altitude≤1000m; VFD will be derated if above 1000m
Impingement and oscillationNormal running:<5.9m/s2 (0.6g); Transportation:<15m/s2 (1.5g)
Store environment–20℃~ +60℃; no dust, no corrosive gas, no direct sunlight

Note: ATO VFD Cannot be used as a power source, it Can only be directly connected to an induction motor to control the motor speed.

Details

750W Three Phase VFD Details

Tips: Why you need a 1-phase 220V to 3-phase 380V VFD?

Due to national policies and regional restrictions, many areas will now withdraw 3-phase 380V industrial power. No 3-phase power in the region to apply for 3-phase power cumbersome procedures and a variety of labor costs and various hidden costs, resulting in some areas can not use industrial 380V power. and general industrial equipment, such as AC motors are mostly 3-phase 380V, in the absence of 3-phase electricity can not run. We can only find ways to convert 1-phase 220V to 3-phase 380V. However, many single phase 220V to three phase 380V equipment on the market are ridiculously expensive, so many users in need are discouraged. And the original machine can only be temporarily placed, or put into other places with industrial electricity to use.

ATO offers a series of 1-phase 220V input to 3-phase 380V output variable frequency drive from 1hp to 20 hp, which can drive 3-phase asynchronous motor soft start operation, for infinitely adjustable speed. The input power only needs single phase 220V, output three phase 380V, and the price is acceptable to most users. Our VFDs are about 1/10 of the price of the booster on the market, compact size, powerful, 0-400Hz can be adjusted at will, completely solve the embarrassing situation of industrial equipment without 3-phase power.

Product reviews
1hp VFD protection method
5
Cliffy
Avatar
4/22/2021 11:41 PM
Protection between 1hp VFD and motor: Could you please tell me quickly why you don't recommend any EMC filters, shielded wires and braking module/transistor?
Was this review helpful? Yes No (0/0)
ATO Responded
Don't recommend anything between 1hp VFD and motor, because motor will be directly controller "on/off/speed, etc" via the VFD.
The scope of use of 1-phase 1hp VFD
5
Cody
Avatar
7/28/2021 9:14 PM
Will your 1hp, 1-phase, 220V drive work for 100-200W motor?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, of course, it works.
Can ATO help me find a suitable VFD?
5
Bertinazzi
Avatar
9/9/2021 12:24 AM
We are looking for a single phase 5hp frequency drive 120 volt input to 3 phase 230 volt output 230 volt 60 Hz for a dive compressor application and we are wondering if this is where you can help us with?
The unit needs to be able to start through an external source in this case the dive compressor and then we are looking for and programmable output for a 120 volt drain valve 10 watts. ideally when the unit starts up, it will energize for about 7 seconds, so the drain solenoid will open and vent while the motor is getting to full speed. Then de-energize for 10 minutes for about 7 seconds and just repeat while the motor is running. If not, can we use the output relay to activate a cycling timer relay?
Was this review helpful? Yes No (0/0)
ATO Responded
SKU: GK3000-SP1S1-004
Our VFD supports single-phase 120V input, and the output voltage is three-phase 220V.
However, this voltage should not affect the 230V motor much, so you can use it normally.
If you can provide your submersible compressor power, voltage, current and other parameters for our reference, it would be better. The rated current capacity of VFD should be larger than your motor rated current.
For the cyclic control requirements you mention below, you can only program them yourself or use the cyclic timer relay.
Please let me know what information you can provide about this series?
5
Pasadas
Avatar
11/21/2021 10:52 PM
Hello, I am interested in more information about the GK3300 series of VFD drives, non-enclosed. Could you provide a manual for this series? I found a manual for the GK3000 series and imagine many things are similar. However, the main thing I wonder is how they are set up since it looks like there is no control readout, buttons or other manual inputs. Is this done with a configuration software maybe? Please let me know what info you can provide regarding this series!
Was this review helpful? Yes No (0/0)
ATO Responded
If you purchase the VFD non-enclosed, it will be equipped with a keyboard to realize input and display the reading function.
Can I increase torque though parameter settings?
5
Tom
Avatar
9/9/2022 2:57 AM
A 3ph 1hp GP ind. motor is used to install the GK3000 to a small wood lathe. The torque feels insufficient. Is it possible to enhance torque using parameter settings? My motor is a 2-pole (per the specs), but I changed the pole parameter to a 4-pole setting, and the torque seemed to increase. Is this a bad idea?
Was this review helpful? Yes No (0/0)
ATO Responded
By adjusting parameter P0.09 to 4% or 6%, you can increase the torque. You might as well return the motor to 2-pole operation at the same time.
I can't find the perimeters on the manual
5
Keran
Avatar
3/21/2023 7:29 PM
I have a VFD model and could use some help on setting the perimeters on the VFD to make it run controlled from a pressure switch to an air compressor. I have the pressure switch connected to COM and FWD terminals, just can't find the perimeters on the manual to set it to run being controlled by the pressure switch.
Was this review helpful? Yes No (0/0)
ATO Responded
Is your compressor pressure switch similar to a button switch with a normally open contact (NO)? If yes, you can use this pressure switch, connect to FWD-COM terminal. Please refer to the settings as follows:
P0.03=1 (run command from terminal)
P4.08=0 (2-wire control mode 1)
P4.00=13 (Define terminal X1 as stop signal)
When your pressure switch is activated, the normally open contact is closed, and the FWD-COM is connected, the VFD will start running. When you press Emergency stop, X1 and COM will be connected, and VFD will stop.
We should control VFD by modbus communication only?
5
Betty
Avatar
6/7/2023 2:58 AM
Thank you for your support.
So you are saying we should control VFD by MODBUS communication only?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, VFD can only be controlled via MODBUS communication.
Is there any video on how to change the VFD parameters?
5
avery
Avatar
7/17/2023 3:41 AM
I bought a VFD from you.
Is there any video on how to change the parameters?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Please provide us with the order number to further confirm what product you purchased.
We hope to provide you with better service.
2. Please refer to the link settings: https://www.youtube.com/@ATOcom/playlists
Can you give advice to solve VFD problem?
5
abner
Avatar
7/25/2023 9:45 PM
Hello! I purchased a gk3000 that went through wiring, and programming, and the milling machine ran.
However, on the endmill cutter, I didn’t seem to be receiving the correct power as well as at a certain point it shut all power to the house down without flipping the breakers within the panel.

I’m going to assume on the machine side some of the programming may be incorrect as I followed the YouTube videos and plugged my motor information as best I could. In any case, I have it switched off at the breaker now and am advantageous to restart because I can not lose power to the house.

I spoke to a mechanical electrician as this transgressed and he was baffled as well.
Any direction, or advice?
Would be greatly appreciated.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Please provide us with the order number to further confirm what product you purchased.
We hope to provide you with better service.

2. Our VFD cannot be used as a power source, it needs to be directly connected to the motor.
Please provide us with your motor nameplate picture for further confirmation.
Which is correct for VFD answer?
5
ritchie
Avatar
8/29/2023 3:38 AM
One of the questions asked about this VFD was whether it maintained the motor within its torque capability at a reduced frequency. The answer was no.
However, the manual indicates that the VFD operates in linear V/F mode only, which would be constant torque below the motor's base speed and constant hp above.
My question is, which is correct? Can the VFD maintain the motor at near 100% rated torque down to at least 80% of its base speed? Thank you.
Was this review helpful? Yes No (0/0)
ATO Responded
When the frequency and speed of a single-phase motor are reduced, the output torque will also drop, and the torque cannot be maintained.
The V/F curve operation mode described in our manual is based on the research of three-phase motors, single-phase motors have not been tested.
I have a question about writing to 0x6000
4
Ives
Avatar
9/19/2024 12:07 AM
I have a question about writing to 0x6000. I’m getting a failure, illegal data value when I try to write a 1. My question, are writes to 0x6000, the command registers limited if pc.03 (command source) is not set to 2 (terminal). I’m just testing at this point and don’t want to interfere otherwise with the VFD so pc.03 is at 0.
Was this review helpful? Yes No (0/0)
ATO Responded
Please read the RS485 communication protocol description carefully. Please read the RS485 communication protocol section of the manual carefully again (Chapter 9), see on: https://www.ato.com/Content/doc/gk3000-variable-frequency-drive-user-manual.pdf
In the communication description section, address 0x6000 is the address of the VFD control parameter group, which can only be read but Not written. Then of course there will be errors when you write.
Only registered users can write reviews
Customers who bought this item also bought

5 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

GK3000-CT0037
$473.54
Best 5 hp variable frequency drive at low price. Single phase 220 volt input to three phase 380 volt output VFD for AC motor speed control, IP20, RS485 enabled, V/F and sensorless vector control mode.

10 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

GK3000-CS0075G
$1,095.67
Affordable price 10 hp (7.5 kW) VFD, converts 220v/ 230v /240v 1 phase input to 380v/ 400v/ 415v 3 phase output, 17 amps, V/F and sensorless vector control.

15 hp VFD, 1-Phase 220V to 3-Phase 380V VFD

GK3000-CS0110G
$1,587.36
Customized 15 hp VFD at best price, with single phase 220v/ 230v/ 240v input, three phase 380v/ 400v/ 415v output. Using it as frequency converter to control AC motor speed.