Portable Nitrogen (N2) Gas Detector, 0 to 100% Vol

$891.38
Portable N2 gas detector, pump suction type, suitable for Nitrogen gas leakage detection with 0 to 100% Vol measuring range, and give an alarm with sound, light and vibration. Light & compact Nitrogen gas detector, high accuracy, fast response, and good cost performance.
SKU: GD200-N2
*
*
*
Availability: In stock
Free Shipping
Delivery date: 2-12 days

Portable Nitrogen (N2) gas detector take sample by built-in pump and has measuring range of 0-100% VOL, fast and accurate measurement and favorable price.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof

Specification

ModelGD200-N2
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasNitrogen (N2)
Note*1. It is recommended that this N2 gas detector only detects a single Nitrogen environment or only N2 and O2 in the environment, as well as Nitrogen leakage in normal air. If you are monitoring other gases mixed with N2, please contact us before purchasing.
2. Nitrogen detectors cannot do zero point calibration in air, only do target calibration (the target concentration is the standard concentration value in clean air).
Range (Optional)*0 to 99.99% VOL, 0 to 100% VOL
Resolution0.01% VOL
Accuracy≤±3% F.S.
Responce Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note 1:

  • If you require an N2 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Portable Nitrogen (N2) Gas Detector Details

Applications

Portable Nitrogen gas detector is used for the N2 concentration detection in the electronic component storage, Nitrogen tank area, food packaging, Nitrogen cylinder and tank purity measurement, laboratory, etc.

Nitrogen N2 Gas Detector ApplicationsTips: Why you need a Nitrogen (N2) gas detector?

Nitrogen (N2) is usually a colorless, odorless gas and generally it is less dense than air. Nitrogen is one of the main components of air, accounting for 78.08% (volume fraction). Under the standard atmospheric pressure, when nitrogen gas is cooled to 195.8℃, it turns into a colorless liquid; when cooled to 209.8℃, the liquid nitrogen becomes a snowy solid. Nitrogen is often used as a preservative because it is chemically inert and difficult to react with other substances at room temperature.

Nitrogen seems to be harmless, but it is still dangerous. If the concentration of nitrogen in the air is too high, the pressure of oxygen in the inhaled air will drop, thus causing hypoxia and asphyxia. When the concentration of inhaled nitrogen is not too high, the patient initially feels chest tightness, shortness of breath and weakness; then there are others symptoms: irritability, extreme excitement, running, screaming, absent-minded, and gait abnormality, known as "nitrogen tincture", entering a drowsiness or coma. When the inhaled nitrogen is at a high concentration, the patients can quickly become unconscious and die from respiratory and cardiac arrest.

It is really necessary to detect the nitrogen concentration before personnel enter tanks, confined spaces, or other areas of high concentration. ATO portable nitrogen gas detector adopts the pumping sampling method, which can quickly and accurately detect the concentration of nitrogen and give the alarm. Thus, the personnel can also check the data in the N2 gas detector and make sure the nitrogen concentration in the confined space meets the standard before the operation, so as to ensure the safety of personnel.

Basic Settings of Portable Gas Detector

This video will show you the basic settings of ATO portable gas detectors including high/low alarm setting, language setting and time setting.

Calibration of Portable Gas Detector

This video will show how to calibrate the ATO portable gas detectors.

Concentration Detection of Pesticides Gas

Methyl bromide is an organic compound with the chemical formula CH3Br, which is mainly used as a pesticide, fumigant, refrigerant and solvent, and can also be used in organic synthesis.This video will mainly use methyl bromide and CH3Br as examples to introduce the detection of their concentrations.

How to Detect Hydrogen Sulfide Concentration in the Toilet

Hydrogen sulfide is a flammable acidic gas that smells like rotten eggs at low concentrations and is very toxic. In actual operation, it is necessary to ensure that the detection equipment or method used can accurately measure the concentration of hydrogen sulfide, and pay attention to safety issues during operation to avoid hydrogen sulfide poisoning.

How much C2H4 (ethylene) do ripe bananas and apples produce?

We have various gas detectors such as: CO, O2, O3, H2, NH3, H2S, CH4, Cl2, CH2O, etc, from 0~10000ppm, Industrial or daily use.

How Does a Portable Detector Work?

This video explains how a portable detector works and uses it to measure the air around you.

Portable Single Gas Detector Parameter Settings

In this video, we show you the menu settings of the ATO portable detector. Five button operation makes it very simple to control and activate functions. This device provides two alarm types, high alarm point and low alarm point, which can be adjusted as needed. The speed of the pump is also allowed to be adjusted. Calibration options include zero calibration and span calibration, both of which should be performed by qualified professionals under strict operating conditions using necessary accessories and standard gases.

How to Calibrate a Portable Gas Detector?

This video shows how to calibrate a portable gas detector. The ATO portable gas detector is lithium battery powered, has data logging capabilities and is available with a calibration kit.

Gas Detector Detection Range Setting

This video demonstrates the detection range setting of a portable gas detector.

Product reviews
The N2 gas detector arrived on time with good packaging.
5
Hans
Avatar
10/29/2019 7:17 PM
The N2 gas detector arrived on time with good packaging. Use it to detect the gas leakage in the Nitrogen tank area. Light, portable and easy to use. Works as advertised. The detector is great helpful to find the danger and gives us sound and vibrating alarm.
Was this review helpful? Yes No (0/0)
Portable gas detector working pressure
5
Niklas
Avatar
11/25/2019 6:02 PM
Can your portable gas detector work under (7-8 bar) pressure?
Was this review helpful? Yes No (0/0)
ATO Responded
No, it can not work properly because the pressure is too high (7-8 bar). Our portable gas detectors can work only under pressure of 1 bar.
N2 gas detector flow rate
5
Josh
Avatar
4/26/2020 7:10 PM
I am very interested in better understanding the different pumping speeds on your N2 gas detector.  Your literature indicates that there are ten different speeds that can be selected, can this setting impact the measurement sensitivity?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Josh. Our gas detector pumping speed is 750ml/min, and both flow & pumping speeds will Not affect measurement sensitivity.
I’m looking for an air and nitrogen leak detector...
5
Jorgen
Avatar
5/8/2020 7:19 PM
I’m looking for an air and nitrogen leak detector – we have installed some equipment that produces nitrogen from air and we would like to use a leak detector (from both air and nitrogen) to find and fix leaks in the entire systems. Please let me know if you have devices that may help me.
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Jorgen. You are welcome. Here you are recommended to use our Portable Nitrogen (N2) Gas Detector with 0 to 100% Vol measuring range, but please note that it cannot measure the N2 below 1%VOL concentration. And our N2 gas detector can set High and Low alarm points, so once the Nitrogen leakage concentration exceeds the alarm point, the detector will sound an alarm to let you know.
Portable Nitrogen (N2) Gas Detector
5
John
Avatar
5/21/2020 7:03 PM
Can your N2 sensor detect nitrogen in the presence of other nitrous gases like NO and NO2 ?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our N2 detector (0-100% Vol) works and the other nitrous gases like NO and NO2, will not affect the measurement.
N2 gas detector
5
Wesley
Avatar
6/1/2020 6:42 PM
Hi. I'm looking for an N2 gas detector with an accuracy of at least 0.5% - do you have?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Wesley. Unfortunately no, we don't have it and our N2 gas detector accuracy is ≤ ±3% F.S.
I require a gas sensor that can detect N2 trace in an Ar atmosphere.
5
Milton
Avatar
8/19/2020 7:02 PM
I require a gas sensor that can detect N2 trace in an Ar atmosphere. Do you have an appropriate sensor?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our gas detector can only measure the gas N2 in air or a single gas N2, Not in an Ar atmosphere.
Portable Nitrogen Gas Detector data logger
5
Paul
Avatar
9/14/2020 6:52 PM
For your Portable Nitrogen Gas Detector, does it have the option to record measured values like a data logger and then transmit the recorded values Wireless to user PC?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our gas detector has the option to record measured values like a Data logger and then transmit the recorded values wirelessly to user PC. We can add a wireless module to the detetcor, so you can monitor and record data on your pc, but this option needs additional payment.
Does your Portable Nitrogen (N2) Gas Detector actually measure nitrogen?
5
Nick
Avatar
9/28/2020 7:03 PM
Does your Portable Nitrogen (N2) Gas Detector actually measure nitrogen? If so, how do you account for the 78% nitrogen in normal atmospheres?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our Portable N2 Gas Detector actually does measure nitrogen. It can measure single nitrogen or nitrogen leakage in the air. In normal air, it will directly display 78.1% of nitrogen and if there is N2 leakage in the air, then the percentage value will increase.
Will your N2 gas detector be able to measure Nitrogen in Hydrocarbon atmosphere?
5
Dirk
Avatar
10/19/2020 6:50 PM
Will your N2 gas detector be able to measure Nitrogen in Hydrocarbon atmosphere?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our N2 gas detector cannot measure Nitrogen in Hydrocarbon atmosphere.
Does your portable Nitrogen detector see Helium?
5
Christopher
Avatar
11/11/2020 1:34 AM
Does your portable Nitrogen detector see Helium?
Was this review helpful? Yes No (0/0)
ATO Responded
No, the portable Nitrogen detector can't see Helium, but we can provide helium gas detector (0-100%VOL), which can only measure the purity of helium gas.
We want to use your portable Nitrogen gas detector...
5
Timothy
Avatar
1/6/2021 6:39 PM
Hi. We want to use your portable Nitrogen gas detector that we can couple another gas with it to be detected. Can you provide a portable gas detector which detects Nitrogen
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, Timothy. Our nitrogen gas detector can only detect a single nitrogen purity or leakage in clean air, and it cannot be used in an environment containing combustible gases. We can provide a separate combustible gas detector, which can detect combustible gases in different environments.
Calibrated N2 gas detector
5
Devon
Avatar
5/8/2021 12:17 AM
Does your N2 gas detetcor come precalibrated?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it is well calibrated before shipping.
Calibration certificate and price of portable nitrogen gas detector
5
Harnendez
Avatar
7/18/2021 8:07 PM
For your portable N2 gas detetcor, can you proivde The certificate of calibration reference type ISO/IEC 17025? And what about Modbus connectivty price?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Our Portable Nitrogen (N2) Gas Detector supports MODBUS communication protocol, but for receiving and sending the data, you have to program yourself, refer to MODBUS communication protocol instructions on our web site.
2. The MODBUS communication protocol is equipped with each portable gas detector, and no additional cost is required.
3. Yes, the certificate of calibration reference type ISO/IEC 17025 can be provided.
My question about the portable nitrogen gas detector
5
Benner
Avatar
11/4/2021 9:24 PM
We are planning to do experiments with different gases (nitrogen, helium) in the lab. Currently we do not have a working ground suction and are looking for an adequate gas alarm system. Would be your portable nitrogen (N2) gas detector, 0 to 100% Vol (ATO-SKY2000-N2) the proper instrument for us? Does this system need a maintenance on a regular basis?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Our portable nitrogen (N2) gas detector, 0 to 100% Vol (ATO-SKY2000-N2) can only be used in a single gas environment, so if the measurement of nitrogen contains other gas mixtures (such as helium ), it will not be suitable.
2. Our gas detector is well calibrated before leaving the factory, and usually it needs to be calibrated after one year.
I have some questions about your portable N2 gas detector
5
Timillionis
Avatar
11/14/2021 7:04 PM
For your portable N2 gas detector, can you provide the certificate of calibration reference type ISO/IEC 17025? And what about the modbus connectivity price?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Our portable Nitrogen (N2) gas detector supports modbus communication protocol, but for receiving and sending the data, you have to program yourself, refer to modbus communication protocol instructions on our web site.
2. The modbus communication protocol is equipped with each portable gas detector, and no additional cost is required.
3. Yes, the certificate of calibration reference type ISO/IEC 17025 can be provided.
Detection of portable nitrogen gas detector
5
Lbrezzy
Avatar
12/9/2021 7:51 PM
My company bills machinery for plastic in some applications we use nitrogen. Is it possible to use ATO-GAS-N2 for the detection of small leaks of our system?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it is suitable for Nitrogen gas leakage detection with 0 to 100% Vol measuring range.
No option available for serial port of N2 gas detector
5
kolt
Avatar
6/15/2023 8:06 PM
I got stuck on the step 1, but I can’t select COM 4.
No option available for serial port.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for your feedback.
We think it may be that the USB is not plugged in properly.
Please use the USB cable to connect the instrument to the computer.
You can also refer to the instruction manual in the attachment.
If the USB is plugged in and there is still a problem, please try to install the driver software in the attachment.
Solve the gas detector problem
5
Betty
Avatar
6/16/2023 2:09 AM
We move forward, thanks!
But another issue show up, after scanning device (step 4) shows next error:
Already try all Baud rate but still same issue.
I will upload error video to the link below.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for your feedback.
1. Please confirm whether the instrument is powered on.
When importing data, the instrument must be turned on.
2. Please check if the serial number is wrong. For serial number serial port selection, please refer to the attached picture.
3. The serial port can be confirmed by plugging and unplugging the instrument. When the instrument is unplugged, the serial port that disappears belongs to this instrument.
Please advice
4
Grinas
Avatar
2/24/2025 1:17 AM
We purchased the handy N2 gas detector and trying to set it up to use for our application. We generally pressurized the pipe the 99.9% pure N2 and want to make sure all connections are tight and leak-free.
The model mentioned in the subject starts after power is on -
The pump starts and the display shows an N2 volume 100% low 79 and high 83.
After that it just shows 100% N2 in the air and continuously beeping. I think it's detecting the N2 in air. How can I calibrate the instrument so it will not detect the N2 in the air and only beep when the tip is close to the leak point? I check the online manual but it's not very helpful.
Was this review helpful? Yes No (0/0)
ATO Responded
N2 detector, the range is only 0-100%VOL (all models) It can detect the N2 concentration in normal air (for example: gas storage room, food storage room, pipeline, etc.).
The nitrogen concentration in normal air is 78.1%VOL. If there is a leak, the reading will increase.
So if you want to measure the leakage of 99.9% pure nitrogen pipeline, you can only measure the increased N2 concentration in the air.
In addition, special attention should be paid to measuring pipeline leakage:
The precautions for connecting pipelines are as follows:
A. The working pressure is stable 1Bar±10%, and the flow rate is controlled at 450~700ml/min.
B. The working temperature is -20°C~+50°C
C. The working humidity is <60%RH.
If >60%RH, we recommend using a dehumidifier.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Portable Nitrogen (N2) gas detector take sample by built-in pump and has measuring range of 0-100% VOL, fast and accurate measurement and favorable price.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof

Specification

ModelGD200-N2
Sampling MethodPumping suction, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasNitrogen (N2)
Note*1. It is recommended that this N2 gas detector only detects a single Nitrogen environment or only N2 and O2 in the environment, as well as Nitrogen leakage in normal air. If you are monitoring other gases mixed with N2, please contact us before purchasing.
2. Nitrogen detectors cannot do zero point calibration in air, only do target calibration (the target concentration is the standard concentration value in clean air).
Range (Optional)*0 to 99.99% VOL, 0 to 100% VOL
Resolution0.01% VOL
Accuracy≤±3% F.S.
Responce Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Brass
  • Max. Input Pressure: ≤15MPa
  • Max. Output Pressure: 0.25MPa
  • Flowmeter Range: 0.1-1.5 L/min
  • Mounting Connection: Inlet port: W21.8-14; Outlet port: Ф6 flexible tube

Note 1:

  • If you require an N2 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Portable Nitrogen (N2) Gas Detector Details

Applications

Portable Nitrogen gas detector is used for the N2 concentration detection in the electronic component storage, Nitrogen tank area, food packaging, Nitrogen cylinder and tank purity measurement, laboratory, etc.

Nitrogen N2 Gas Detector ApplicationsTips: Why you need a Nitrogen (N2) gas detector?

Nitrogen (N2) is usually a colorless, odorless gas and generally it is less dense than air. Nitrogen is one of the main components of air, accounting for 78.08% (volume fraction). Under the standard atmospheric pressure, when nitrogen gas is cooled to 195.8℃, it turns into a colorless liquid; when cooled to 209.8℃, the liquid nitrogen becomes a snowy solid. Nitrogen is often used as a preservative because it is chemically inert and difficult to react with other substances at room temperature.

Nitrogen seems to be harmless, but it is still dangerous. If the concentration of nitrogen in the air is too high, the pressure of oxygen in the inhaled air will drop, thus causing hypoxia and asphyxia. When the concentration of inhaled nitrogen is not too high, the patient initially feels chest tightness, shortness of breath and weakness; then there are others symptoms: irritability, extreme excitement, running, screaming, absent-minded, and gait abnormality, known as "nitrogen tincture", entering a drowsiness or coma. When the inhaled nitrogen is at a high concentration, the patients can quickly become unconscious and die from respiratory and cardiac arrest.

It is really necessary to detect the nitrogen concentration before personnel enter tanks, confined spaces, or other areas of high concentration. ATO portable nitrogen gas detector adopts the pumping sampling method, which can quickly and accurately detect the concentration of nitrogen and give the alarm. Thus, the personnel can also check the data in the N2 gas detector and make sure the nitrogen concentration in the confined space meets the standard before the operation, so as to ensure the safety of personnel.

Product reviews
The N2 gas detector arrived on time with good packaging.
5
Hans
Avatar
10/29/2019 7:17 PM
The N2 gas detector arrived on time with good packaging. Use it to detect the gas leakage in the Nitrogen tank area. Light, portable and easy to use. Works as advertised. The detector is great helpful to find the danger and gives us sound and vibrating alarm.
Was this review helpful? Yes No (0/0)
Portable gas detector working pressure
5
Niklas
Avatar
11/25/2019 6:02 PM
Can your portable gas detector work under (7-8 bar) pressure?
Was this review helpful? Yes No (0/0)
ATO Responded
No, it can not work properly because the pressure is too high (7-8 bar). Our portable gas detectors can work only under pressure of 1 bar.
N2 gas detector flow rate
5
Josh
Avatar
4/26/2020 7:10 PM
I am very interested in better understanding the different pumping speeds on your N2 gas detector.  Your literature indicates that there are ten different speeds that can be selected, can this setting impact the measurement sensitivity?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Josh. Our gas detector pumping speed is 750ml/min, and both flow & pumping speeds will Not affect measurement sensitivity.
I’m looking for an air and nitrogen leak detector...
5
Jorgen
Avatar
5/8/2020 7:19 PM
I’m looking for an air and nitrogen leak detector – we have installed some equipment that produces nitrogen from air and we would like to use a leak detector (from both air and nitrogen) to find and fix leaks in the entire systems. Please let me know if you have devices that may help me.
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Jorgen. You are welcome. Here you are recommended to use our Portable Nitrogen (N2) Gas Detector with 0 to 100% Vol measuring range, but please note that it cannot measure the N2 below 1%VOL concentration. And our N2 gas detector can set High and Low alarm points, so once the Nitrogen leakage concentration exceeds the alarm point, the detector will sound an alarm to let you know.
Portable Nitrogen (N2) Gas Detector
5
John
Avatar
5/21/2020 7:03 PM
Can your N2 sensor detect nitrogen in the presence of other nitrous gases like NO and NO2 ?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our N2 detector (0-100% Vol) works and the other nitrous gases like NO and NO2, will not affect the measurement.
N2 gas detector
5
Wesley
Avatar
6/1/2020 6:42 PM
Hi. I'm looking for an N2 gas detector with an accuracy of at least 0.5% - do you have?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Wesley. Unfortunately no, we don't have it and our N2 gas detector accuracy is ≤ ±3% F.S.
I require a gas sensor that can detect N2 trace in an Ar atmosphere.
5
Milton
Avatar
8/19/2020 7:02 PM
I require a gas sensor that can detect N2 trace in an Ar atmosphere. Do you have an appropriate sensor?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our gas detector can only measure the gas N2 in air or a single gas N2, Not in an Ar atmosphere.
Portable Nitrogen Gas Detector data logger
5
Paul
Avatar
9/14/2020 6:52 PM
For your Portable Nitrogen Gas Detector, does it have the option to record measured values like a data logger and then transmit the recorded values Wireless to user PC?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our gas detector has the option to record measured values like a Data logger and then transmit the recorded values wirelessly to user PC. We can add a wireless module to the detetcor, so you can monitor and record data on your pc, but this option needs additional payment.
Does your Portable Nitrogen (N2) Gas Detector actually measure nitrogen?
5
Nick
Avatar
9/28/2020 7:03 PM
Does your Portable Nitrogen (N2) Gas Detector actually measure nitrogen? If so, how do you account for the 78% nitrogen in normal atmospheres?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, our Portable N2 Gas Detector actually does measure nitrogen. It can measure single nitrogen or nitrogen leakage in the air. In normal air, it will directly display 78.1% of nitrogen and if there is N2 leakage in the air, then the percentage value will increase.
Will your N2 gas detector be able to measure Nitrogen in Hydrocarbon atmosphere?
5
Dirk
Avatar
10/19/2020 6:50 PM
Will your N2 gas detector be able to measure Nitrogen in Hydrocarbon atmosphere?
Was this review helpful? Yes No (0/0)
ATO Responded
Unfortunately, our N2 gas detector cannot measure Nitrogen in Hydrocarbon atmosphere.
Does your portable Nitrogen detector see Helium?
5
Christopher
Avatar
11/11/2020 1:34 AM
Does your portable Nitrogen detector see Helium?
Was this review helpful? Yes No (0/0)
ATO Responded
No, the portable Nitrogen detector can't see Helium, but we can provide helium gas detector (0-100%VOL), which can only measure the purity of helium gas.
We want to use your portable Nitrogen gas detector...
5
Timothy
Avatar
1/6/2021 6:39 PM
Hi. We want to use your portable Nitrogen gas detector that we can couple another gas with it to be detected. Can you provide a portable gas detector which detects Nitrogen
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, Timothy. Our nitrogen gas detector can only detect a single nitrogen purity or leakage in clean air, and it cannot be used in an environment containing combustible gases. We can provide a separate combustible gas detector, which can detect combustible gases in different environments.
Calibrated N2 gas detector
5
Devon
Avatar
5/8/2021 12:17 AM
Does your N2 gas detetcor come precalibrated?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it is well calibrated before shipping.
Calibration certificate and price of portable nitrogen gas detector
5
Harnendez
Avatar
7/18/2021 8:07 PM
For your portable N2 gas detetcor, can you proivde The certificate of calibration reference type ISO/IEC 17025? And what about Modbus connectivty price?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Our Portable Nitrogen (N2) Gas Detector supports MODBUS communication protocol, but for receiving and sending the data, you have to program yourself, refer to MODBUS communication protocol instructions on our web site.
2. The MODBUS communication protocol is equipped with each portable gas detector, and no additional cost is required.
3. Yes, the certificate of calibration reference type ISO/IEC 17025 can be provided.
My question about the portable nitrogen gas detector
5
Benner
Avatar
11/4/2021 9:24 PM
We are planning to do experiments with different gases (nitrogen, helium) in the lab. Currently we do not have a working ground suction and are looking for an adequate gas alarm system. Would be your portable nitrogen (N2) gas detector, 0 to 100% Vol (ATO-SKY2000-N2) the proper instrument for us? Does this system need a maintenance on a regular basis?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Our portable nitrogen (N2) gas detector, 0 to 100% Vol (ATO-SKY2000-N2) can only be used in a single gas environment, so if the measurement of nitrogen contains other gas mixtures (such as helium ), it will not be suitable.
2. Our gas detector is well calibrated before leaving the factory, and usually it needs to be calibrated after one year.
I have some questions about your portable N2 gas detector
5
Timillionis
Avatar
11/14/2021 7:04 PM
For your portable N2 gas detector, can you provide the certificate of calibration reference type ISO/IEC 17025? And what about the modbus connectivity price?
Was this review helpful? Yes No (0/0)
ATO Responded
1. Our portable Nitrogen (N2) gas detector supports modbus communication protocol, but for receiving and sending the data, you have to program yourself, refer to modbus communication protocol instructions on our web site.
2. The modbus communication protocol is equipped with each portable gas detector, and no additional cost is required.
3. Yes, the certificate of calibration reference type ISO/IEC 17025 can be provided.
Detection of portable nitrogen gas detector
5
Lbrezzy
Avatar
12/9/2021 7:51 PM
My company bills machinery for plastic in some applications we use nitrogen. Is it possible to use ATO-GAS-N2 for the detection of small leaks of our system?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it is suitable for Nitrogen gas leakage detection with 0 to 100% Vol measuring range.
No option available for serial port of N2 gas detector
5
kolt
Avatar
6/15/2023 8:06 PM
I got stuck on the step 1, but I can’t select COM 4.
No option available for serial port.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for your feedback.
We think it may be that the USB is not plugged in properly.
Please use the USB cable to connect the instrument to the computer.
You can also refer to the instruction manual in the attachment.
If the USB is plugged in and there is still a problem, please try to install the driver software in the attachment.
Solve the gas detector problem
5
Betty
Avatar
6/16/2023 2:09 AM
We move forward, thanks!
But another issue show up, after scanning device (step 4) shows next error:
Already try all Baud rate but still same issue.
I will upload error video to the link below.
Was this review helpful? Yes No (0/0)
ATO Responded
Thanks for your feedback.
1. Please confirm whether the instrument is powered on.
When importing data, the instrument must be turned on.
2. Please check if the serial number is wrong. For serial number serial port selection, please refer to the attached picture.
3. The serial port can be confirmed by plugging and unplugging the instrument. When the instrument is unplugged, the serial port that disappears belongs to this instrument.
Please advice
4
Grinas
Avatar
2/24/2025 1:17 AM
We purchased the handy N2 gas detector and trying to set it up to use for our application. We generally pressurized the pipe the 99.9% pure N2 and want to make sure all connections are tight and leak-free.
The model mentioned in the subject starts after power is on -
The pump starts and the display shows an N2 volume 100% low 79 and high 83.
After that it just shows 100% N2 in the air and continuously beeping. I think it's detecting the N2 in air. How can I calibrate the instrument so it will not detect the N2 in the air and only beep when the tip is close to the leak point? I check the online manual but it's not very helpful.
Was this review helpful? Yes No (0/0)
ATO Responded
N2 detector, the range is only 0-100%VOL (all models) It can detect the N2 concentration in normal air (for example: gas storage room, food storage room, pipeline, etc.).
The nitrogen concentration in normal air is 78.1%VOL. If there is a leak, the reading will increase.
So if you want to measure the leakage of 99.9% pure nitrogen pipeline, you can only measure the increased N2 concentration in the air.
In addition, special attention should be paid to measuring pipeline leakage:
The precautions for connecting pipelines are as follows:
A. The working pressure is stable 1Bar±10%, and the flow rate is controlled at 450~700ml/min.
B. The working temperature is -20°C~+50°C
C. The working humidity is <60%RH.
If >60%RH, we recommend using a dehumidifier.
Only registered users can write reviews
Customers who bought this item also bought

Portable Oxygen (O2) Gas Detector, 0 to 30% Vol

GD200-O2
$479.22
Portable oxygen detector, ideal for monitoring O2 gas concentration in the range of 0 to 30% Vol or 0 to 100% Vol, with sound, light and vibrating alarm, light and compact, easy to setting and operation, long working time with large capacity battery, high accuracy and low price.

Handheld Carbon Monoxide (CO) Gas Detector, 0 to 500/1000/2000 ppm

GD200-CO
$398.76
Handheld carbon monoxide (CO) detector use high accuracy sensor, pump suction type, selectable measuring range of 0 to 500 ppm, 0 to 1000 ppm, 0 to 2000 ppm, gas leak alarm with audible, visual and vibrating, compact size and light weight, long working time, easy to carry and operation.

Handheld Ammonia (NH3) Gas Detector, 0 to 50/100/500 ppm

GD200-NH3
$828.16
Low price handheld pumping-type gas detector provides the Ammonia (NH3) gas leak monitoring with high accuracy sensor, audible and visual alarm, optional measuring range 0 to 50ppm, 0 to 100ppm, 0 to 200ppm, 0 to 500ppm etc., LCD display, easy readout, small & portable design, convenient to carry.

Portable Hydrogen (H2) Gas Detector, 0 to 500/1000/2000 ppm

GD200-H2
$784.62
Portable hydrogen (H2) gas detector draws the gas sample by a micro pump, with high accuracy and reliability, measurement ranging from 0 to 500ppm, 1000ppm, 2000ppm, 5000ppm for your choice. Real-time LCD display, audible, visual & vibrating alarm, durable and compact design, easy to carry and operate. High precision H2 detector with measuring range 0-10ppm (0.001ppm) is also available.

Portable Carbon Dioxide (CO2) Infrared Gas Detector, 0 to 2000/5000/10000 ppm

GD200-CO2
$969.23
Portable carbon dioxide (CO2) infrared detector adopts high accuracy sensor, measuring range available with 0-2000ppm, 0-5000ppm, 0-10000ppm, or 0-10%VOL, 0-20%VOL, 0 to 100% VOL, with LCD display, audible, visual & vibrating alarm, compact size, easy to carry and operate.