Portable Ozone (O3) Gas Detector, 0 to 10/20/50 ppm

$815.39
Portable Ozone gas detector, applied for the O3 gas detection with high accuracy and fast response, measuring range from 0 to 10ppm / 20ppm / 50ppm for options, real-time LCD display, give sound, light & vibrating alarm, small & light O3 detector at affordable price, handheld design, convenient to carry around.
SKU: GD200-O3
*
*
*
Availability: In stock
Free Shipping
Delivery date: 2-12 days

Portable O3 gas detector with alarm is suitable to monitor the Ozone concentration in range of 0 to 10/20/50/100ppm with high precision sensor and economical price.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof.

Specification

ModelGD200-O3
Sampling MethodPump suction type, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasOzone (O3)
Range (Optional)*0 to 1ppm, 0 to 5ppm, 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm, 0 to 200ppm, 0 to 500ppm, 0 to 1000ppm, 0 to 2000ppm
Resolution0.001 (0-1ppm), 0.01ppm (0-5/10/20/50ppm), 0.1ppm (0-100ppm), 1ppm (0-200/500/1000/2000ppm)
Accuracy≤±3% F.S.
Responce Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Stainless steel
  • Input Range of Pressure Gauge: 0-25MPa
  • Output Range of Pressure Gauge: 0-0.6Mpa
  • Gauge Class: 2.5
  • Input Pressure: ≤15MPa
  • Output Pressure: ≤0.45MPa
  • Rated Flow: 0.6 m3/h
  • Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation); Outlet: Ф6 flexible tube

Note 1:

  • If you require an O3 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Portable Ozone (O3) Gas Detector Details

Applications

Handheld Ozone gas detector is widely used for O3 gas measurement in the clean area, pharmaceutical factory, food factory, cosmetics factory, laboratory and so on.

Ozone O3 Gas Detector Applications

Tips: Use Case - Ozone (O3) Detector in Pharmaceutical Factory

A pharmaceutical factory, specializing in research, production and sales of various chemical API, requires testing whether ozone disinfection in the workshop reaches the effect of sterilization.

Separate sterilization is required in the workshop of pharmaceutical plant. Ozone generator with a certain concentration, which is selected according to the size of the room space, is directly installed in the room. And the disinfection time is also set as required. The ozone generator will automatically shut down after the disinfection finishes. Then, it need to check whether the room disinfection has achieved the effect. The pharmacy manager said that there is a hundred-level workshop, and about 20ppm ozone concentration can achieve the standard for disinfection. In additions, there are no workers in the room to monitor ozone levels during disinfection.

According to the requirements of the manager of the pharmaceutical factory, the ozone concentration is not up to the standard until it reaches 20ppm. The ozone (O3) gas detector ATO-GAS-O3 is recommended, with measuring range of 0-50ppm and data storage and export functions. In this way, the ozone detector can be set the storage interval, such as 5 seconds to store a data. Before disinfection, put the detector in the disinfected room. After disinfection, take out the O3 detector and export the data to an Excel sheet in the computer via USB. Thus, the data can also be printed out for checking. This model of ozone gas detector has a sampling pump inside, which will draw the gas into the instrument for detection. The gas detector has fast response and high accuracy. Because ozone is toxic, it is better to choose pump suction type to avoid ozone poisoning.

Basic Settings of Portable Gas Detector

This video will show you the basic settings of ATO portable gas detectors including high/low alarm setting, language setting and time setting.

Calibration of Portable Gas Detector

This video will show how to calibrate the ATO portable gas detectors.

Concentration Detection of Pesticides Gas

Methyl bromide is an organic compound with the chemical formula CH3Br, which is mainly used as a pesticide, fumigant, refrigerant and solvent, and can also be used in organic synthesis.This video will mainly use methyl bromide and CH3Br as examples to introduce the detection of their concentrations.

How to Detect Hydrogen Sulfide Concentration in the Toilet

Hydrogen sulfide is a flammable acidic gas that smells like rotten eggs at low concentrations and is very toxic. In actual operation, it is necessary to ensure that the detection equipment or method used can accurately measure the concentration of hydrogen sulfide, and pay attention to safety issues during operation to avoid hydrogen sulfide poisoning.

How much C2H4 (ethylene) do ripe bananas and apples produce?

We have various gas detectors such as: CO, O2, O3, H2, NH3, H2S, CH4, Cl2, CH2O, etc, from 0~10000ppm, Industrial or daily use.

How Does a Portable Detector Work?

This video explains how a portable detector works and uses it to measure the air around you.

Portable Single Gas Detector Parameter Settings

In this video, we show you the menu settings of the ATO portable detector. Five button operation makes it very simple to control and activate functions. This device provides two alarm types, high alarm point and low alarm point, which can be adjusted as needed. The speed of the pump is also allowed to be adjusted. Calibration options include zero calibration and span calibration, both of which should be performed by qualified professionals under strict operating conditions using necessary accessories and standard gases.

How to Calibrate a Portable Gas Detector?

This video shows how to calibrate a portable gas detector. The ATO portable gas detector is lithium battery powered, has data logging capabilities and is available with a calibration kit.

Gas Detector Detection Range Setting

This video demonstrates the detection range setting of a portable gas detector.

Product reviews
Does your O3 gas detector come pre-calibrated?
5
Jack
Avatar
6/27/2019 2:14 AM
Does your O3 gas detector come pre-calibrated?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it is well calibrated before shipping.
Charging time of portable ozone detector
5
Ryan
Avatar
11/11/2019 6:22 PM
How long does it take to get your O3 gas detector to be fully charged?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Ryan. It takes about 5-6 hours for the O3 detector to be fully charged.
Ozone gas detector internal pump
5
Rahul
Avatar
12/2/2019 6:33 PM
For your ozone gas detector, does the internal pump work continuously? And what is the pump flow speed?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Rahul. As long as the gas detector is detecting, the pump must be on, and the flow speed of the pump is 700mg/min.
Can you provide 1m long air hose?
5
Stephen
Avatar
4/26/2020 7:00 PM
We shall buy your O3 gas detector, can you provide 1m long air hose?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can provide 1m long air hose free of charge. Just remind us after ordering, so we can take care about this requirement.
Portable Ozone Gas Monitor 0-500ppm
5
Jim
Avatar
5/6/2020 6:49 PM
Can you provide digital Portable Ozone Gas Monitor with 0-500ppm measuring range?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Jim. We can provide O3 deector with 0-500ppm measuring range and 0.1ppm resolution.
Factory calibration certificate for your portable ozone (O3) gas detector
5
Barry
Avatar
6/8/2020 6:45 PM
Can you provide standard factory calibration certificate for Portable Ozone (O3) Gas Detector? What is the price?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can provide standard factory calibration certificate free of charge.
We need to use your O3 gas detector in a closed loop system...
5
Roman
Avatar
6/30/2020 6:41 PM
Hi. We need to use your O3 gas detector in a closed loop system and a PC will have to interface with our controller, not a person.
What we need is to be able to read the data from your O3 detector in real time, and to send these data to our system by means of a PC.
Could you please kindly provide us with the communication protocol so that we may interrogate the O3 detector on the measurement it’s taking in real time?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Roman. Just note that our Portable Ozone (O3) Gas Detector only has the data logging function. But if you want to communicate your PC via RS485 and view data in real time, it is recommended to use our Fixed Gas Detector with RS485 output (optional), and we can provide RS485 protocol for such purpose.
I have a couple of questions about the Portable Ozone (O3) Gas Detector...
5
Dominic
Avatar
9/8/2020 7:09 PM
I have a couple of questions about the Portable Ozone (O3) Gas Detector, 0 to 10 ppm to be used for ambient Ozone detection:
- Is calibration required for the device? How often is it required to be calibrated?
- We are going to use this device to detect Ozone gas in our lab environment. What is its detection board? Can it detect the ozone gas from 5m distance? or we should be very close to the area with high ozone concentration?
- Is it a directional device? it means can device detect the ozone gas in all directions or it should be held in a specific direction to detect the gas?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Dominic. For your questions, please check below:
- The gas detector will be well calibrated before leaving the factory, and you can re-calibrate after 6 month or 12 month based on your usage.
- The detection range is 15 meter, so there will not be a problem for 5 meters.
- The gas detector has a suction pump, so it automatically absorb the surrounding gas, so the device detects the ozone gas in all directions.
Ozone gas detetcor measuring principle
5
Ana
Avatar
11/24/2020 6:12 PM
Is your Ozone gas detetcor measuring principle UV absorption?
Was this review helpful? Yes No (0/0)
ATO Responded
No,  the measurement principle of our O3 detector is electrochemical, not the UV absorption.
Questions and answers about ozone gas detector
5
Yoder
Avatar
10/12/2021 8:42 PM
We are interested in purchasing some of your ozone devices that have the 0-10 ppm range. We have a bunch of questions though:
What is the resolution?
Was this review helpful? Yes No (0/0)
ATO Responded
How low can it accurately read?
Is there traceability/calibration?
1. For ozone measuring range in 0-10 ppm, the resolution is 0.01 ppm, and the lowest accurate detection limit is 0.2 ppm.
2. We will calibrate the gas detector before leaving the factory, using ozone generator 1:1 to calibrate, and provide the factory standard calibration report for your reference.
This is an item worth repurchasing
5
Ezra
Avatar
4/19/2022 2:41 AM
When I encounter problems in the experiment, ATO engineers will patiently and timely answer my doubts, which improves my favorability of this detector, and my colleagues also say that this is a good ozone gas detector.
Was this review helpful? Yes No (0/0)
delivery time
5
Alian
Avatar
7/29/2022 3:42 PM
If I order a O3 sensor, how long it can arrive (within US)?
Was this review helpful? Yes No (0/0)
ATO Responded
3~4 days to the United States. If the calibration kit is added, it will take about a week.
which measuring range to puchase?
5
Carmen
Avatar
5/28/2025 9:02 AM
I am interested in measuring the ground ozone level inside poorly ventilated spaces. Would the 0-1ppm high precision one fit my need?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can meet your needs.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Portable O3 gas detector with alarm is suitable to monitor the Ozone concentration in range of 0 to 10/20/50/100ppm with high precision sensor and economical price.

Features

  • LCD dot matrix display, direct readout of gas type, unit, concentration, local time, etc.
  • Support English/Chinese operation, easy to shift.
  • Gas concentration unit PPM and mg/m3 can be shift quickly.
  • Built-in micro-sampling pump, 10 grades of suction are available.
  • Explosion-proof certification

Gas Detector Functions

  • With self-calibration and zero calibration functions, makes the detection more accurate and reliable.
  • One key to restore factory setting, free from maloperation.
  • With temperature and pressure compensation, able to realize the compensation for the gas concentration under different temperature and pressure environments.
  • Two-stage alarm with sound and light, and alarm point is settable.
  • Rechargeable lithiumpolymer battery with large capacity.
  • High-strength special engineering plastic housing, with anti-slip, waterproof, dustproof and explosion-proof.

Specification

ModelGD200-O3
Sampling MethodPump suction type, flow rate can be up to 750ml/min
Detection PrincipleElectrochemistry
GasOzone (O3)
Range (Optional)*0 to 1ppm, 0 to 5ppm, 0 to 10ppm, 0 to 20ppm, 0 to 50ppm, 0 to 100ppm, 0 to 200ppm, 0 to 500ppm, 0 to 1000ppm, 0 to 2000ppm
Resolution0.001 (0-1ppm), 0.01ppm (0-5/10/20/50ppm), 0.1ppm (0-100ppm), 1ppm (0-200/500/1000/2000ppm)
Accuracy≤±3% F.S.
Responce Time≤10s
Repeatability≤±1%
Recovery Time≤10s
Linearity Error≤±1%
Zero Shift≤±1% (F.S./year)
Data Logging (Optional Function)High speed data transmission by USB, available for data downloading and printing (The built-in IC card has about 2G memory, which can record 100,000 sets of data.)
AlarmsSound, light and vibration
DisplayLCD dot matrix display
LanguageChinese/English
Battery3.7V rechargeable lithium battery, 3.7 Watt (Charger included: Input AC 100-240V 50/60Hz with optional USA, Europe or UK plug)
Operating Time100h (Pump off)
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
Case MaterialABS+PC
Protection GradeIP66
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Operating Temperature-20℃~50℃
Operating Humidity0~95%RH (non-condensing)
Operating Pressure0.8~1.2bar
Dimension205*75*32mm
Weight300g
Warranty12 months
Extension ProbeAbout 480mm (Total Length), About 300mm (Probe Head)
Accessories (Optional)Calibration kit - gas pressure regulator (calibration gas cylinder NOT included)
  • Body Material: Stainless steel
  • Input Range of Pressure Gauge: 0-25MPa
  • Output Range of Pressure Gauge: 0-0.6Mpa
  • Gauge Class: 2.5
  • Input Pressure: ≤15MPa
  • Output Pressure: ≤0.45MPa
  • Rated Flow: 0.6 m3/h
  • Connection: Inlet: W21.8-14 teeth/inch (levorotation, dextrorotation); Outlet: Ф6 flexible tube

Note 1:

  • If you require an O3 gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.

*** Other Common Gases and Ranges Available for Portable Gas Detectors

Gas TypeMeasure RangeResolution
Ammonia (NH3)0-10/20/50/100/200/500/1000/2000/5000ppm0.01ppm/0.1ppm/1ppm
Benzene (C6H6)0-1/5/10/20/50/100/200/500/1000/2000/5000/10000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Carbon Dioxide (CO2)0-1000/2000/5000/10000/20000/50000ppm, 0-10%/20%/30%/50%/100% VOL1ppm, 0.01% VOL
Carbon Monoxide (CO)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/1ppm
Chlorine (Cl2)0-5/10/20/50/100/200ppm0.001ppm/0.01ppm/0.1ppm
Chlorine Dioxide (ClO2)0-1/5/10/20/50/100ppm0.001ppm/0.01ppm/0.1ppm
Ethylene (C2H4)0-10/20/50/100/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Flammable0-100% LEL1% LEL
Formaldehyde (CH2O)0-10/20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Hydrocarbons (HC)0-100% LEL1% LEL
Hydrogen (H2)0-10/20/100/500/1000/2000/3000/5000/10000/20000/40000ppm, 0-4% VOL0.001ppm/0.01ppm/0.1ppm/1ppm, 0.001% VOL
Hydrogen Chloride (HCl)0-10/20/50/100/200/500/1000/2000ppm0.01ppm/0.1ppm/1ppm
Hydrogen Cyanide (HCN)0-10/20/50/100ppm0.01ppm/0.1ppm
Hydrogen Fluoride (HF)0-1/5/10/50ppm0.001ppm/0.01ppm
Hydrogen Sulfide (H2S)0-5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Methane (CH4)0-100% LEL, 0-50%/100% VOL1% LEL, 0.01%VOL
Methyl Bromide (CH3Br)0-50/100/200/500/1000/2000/3000ppm0.1ppm/1ppm
Nitric Oxide (NO)0-20/50/100/250/500/1000ppm0.01ppm/0.1ppm/1ppm
Nitrogen (N2)0-99.99%/100% VOL0.01% VOL
Nitrogen Dioxide (NO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Oxygen (O2)0-25%/30%/100% VOL0.01% VOL
Ozone (O3)0-1/5/10/20/50/100/200/500/1000/2000ppm0.001ppm/0.01ppm/0.1ppm/1ppm
Phosgene (COCl2)0-1/5/10ppm0.001ppm
Phosphine (PH3)0-10/20/50/100/500/1000/2000/3000ppm0.01ppm/0.1ppm/1ppm
Sulfur Dioxide (SO2)0-20/50/100/500/1000ppm0.01ppm/0.1ppm/1ppm
Sulfur Hexafluoride (SF6)0-1000/2000/3000ppm1ppm
Volatile Organic Compounds (VOC)0-1/5/10/20/100ppm0.01ppm/0.1ppm


Details

Portable Ozone (O3) Gas Detector Details

Applications

Handheld Ozone gas detector is widely used for O3 gas measurement in the clean area, pharmaceutical factory, food factory, cosmetics factory, laboratory and so on.

Ozone O3 Gas Detector Applications

Tips: Use Case - Ozone (O3) Detector in Pharmaceutical Factory

A pharmaceutical factory, specializing in research, production and sales of various chemical API, requires testing whether ozone disinfection in the workshop reaches the effect of sterilization.

Separate sterilization is required in the workshop of pharmaceutical plant. Ozone generator with a certain concentration, which is selected according to the size of the room space, is directly installed in the room. And the disinfection time is also set as required. The ozone generator will automatically shut down after the disinfection finishes. Then, it need to check whether the room disinfection has achieved the effect. The pharmacy manager said that there is a hundred-level workshop, and about 20ppm ozone concentration can achieve the standard for disinfection. In additions, there are no workers in the room to monitor ozone levels during disinfection.

According to the requirements of the manager of the pharmaceutical factory, the ozone concentration is not up to the standard until it reaches 20ppm. The ozone (O3) gas detector ATO-GAS-O3 is recommended, with measuring range of 0-50ppm and data storage and export functions. In this way, the ozone detector can be set the storage interval, such as 5 seconds to store a data. Before disinfection, put the detector in the disinfected room. After disinfection, take out the O3 detector and export the data to an Excel sheet in the computer via USB. Thus, the data can also be printed out for checking. This model of ozone gas detector has a sampling pump inside, which will draw the gas into the instrument for detection. The gas detector has fast response and high accuracy. Because ozone is toxic, it is better to choose pump suction type to avoid ozone poisoning.

Product reviews
Does your O3 gas detector come pre-calibrated?
5
Jack
Avatar
6/27/2019 2:14 AM
Does your O3 gas detector come pre-calibrated?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it is well calibrated before shipping.
Charging time of portable ozone detector
5
Ryan
Avatar
11/11/2019 6:22 PM
How long does it take to get your O3 gas detector to be fully charged?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Ryan. It takes about 5-6 hours for the O3 detector to be fully charged.
Ozone gas detector internal pump
5
Rahul
Avatar
12/2/2019 6:33 PM
For your ozone gas detector, does the internal pump work continuously? And what is the pump flow speed?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Rahul. As long as the gas detector is detecting, the pump must be on, and the flow speed of the pump is 700mg/min.
Can you provide 1m long air hose?
5
Stephen
Avatar
4/26/2020 7:00 PM
We shall buy your O3 gas detector, can you provide 1m long air hose?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can provide 1m long air hose free of charge. Just remind us after ordering, so we can take care about this requirement.
Portable Ozone Gas Monitor 0-500ppm
5
Jim
Avatar
5/6/2020 6:49 PM
Can you provide digital Portable Ozone Gas Monitor with 0-500ppm measuring range?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Jim. We can provide O3 deector with 0-500ppm measuring range and 0.1ppm resolution.
Factory calibration certificate for your portable ozone (O3) gas detector
5
Barry
Avatar
6/8/2020 6:45 PM
Can you provide standard factory calibration certificate for Portable Ozone (O3) Gas Detector? What is the price?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can provide standard factory calibration certificate free of charge.
We need to use your O3 gas detector in a closed loop system...
5
Roman
Avatar
6/30/2020 6:41 PM
Hi. We need to use your O3 gas detector in a closed loop system and a PC will have to interface with our controller, not a person.
What we need is to be able to read the data from your O3 detector in real time, and to send these data to our system by means of a PC.
Could you please kindly provide us with the communication protocol so that we may interrogate the O3 detector on the measurement it’s taking in real time?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Roman. Just note that our Portable Ozone (O3) Gas Detector only has the data logging function. But if you want to communicate your PC via RS485 and view data in real time, it is recommended to use our Fixed Gas Detector with RS485 output (optional), and we can provide RS485 protocol for such purpose.
I have a couple of questions about the Portable Ozone (O3) Gas Detector...
5
Dominic
Avatar
9/8/2020 7:09 PM
I have a couple of questions about the Portable Ozone (O3) Gas Detector, 0 to 10 ppm to be used for ambient Ozone detection:
- Is calibration required for the device? How often is it required to be calibrated?
- We are going to use this device to detect Ozone gas in our lab environment. What is its detection board? Can it detect the ozone gas from 5m distance? or we should be very close to the area with high ozone concentration?
- Is it a directional device? it means can device detect the ozone gas in all directions or it should be held in a specific direction to detect the gas?
Was this review helpful? Yes No (0/0)
ATO Responded
Hi, Dominic. For your questions, please check below:
- The gas detector will be well calibrated before leaving the factory, and you can re-calibrate after 6 month or 12 month based on your usage.
- The detection range is 15 meter, so there will not be a problem for 5 meters.
- The gas detector has a suction pump, so it automatically absorb the surrounding gas, so the device detects the ozone gas in all directions.
Ozone gas detetcor measuring principle
5
Ana
Avatar
11/24/2020 6:12 PM
Is your Ozone gas detetcor measuring principle UV absorption?
Was this review helpful? Yes No (0/0)
ATO Responded
No,  the measurement principle of our O3 detector is electrochemical, not the UV absorption.
Questions and answers about ozone gas detector
5
Yoder
Avatar
10/12/2021 8:42 PM
We are interested in purchasing some of your ozone devices that have the 0-10 ppm range. We have a bunch of questions though:
What is the resolution?
Was this review helpful? Yes No (0/0)
ATO Responded
How low can it accurately read?
Is there traceability/calibration?
1. For ozone measuring range in 0-10 ppm, the resolution is 0.01 ppm, and the lowest accurate detection limit is 0.2 ppm.
2. We will calibrate the gas detector before leaving the factory, using ozone generator 1:1 to calibrate, and provide the factory standard calibration report for your reference.
This is an item worth repurchasing
5
Ezra
Avatar
4/19/2022 2:41 AM
When I encounter problems in the experiment, ATO engineers will patiently and timely answer my doubts, which improves my favorability of this detector, and my colleagues also say that this is a good ozone gas detector.
Was this review helpful? Yes No (0/0)
delivery time
5
Alian
Avatar
7/29/2022 3:42 PM
If I order a O3 sensor, how long it can arrive (within US)?
Was this review helpful? Yes No (0/0)
ATO Responded
3~4 days to the United States. If the calibration kit is added, it will take about a week.
which measuring range to puchase?
5
Carmen
Avatar
5/28/2025 9:02 AM
I am interested in measuring the ground ozone level inside poorly ventilated spaces. Would the 0-1ppm high precision one fit my need?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, it can meet your needs.
Only registered users can write reviews
Customers who bought this item also bought

Portable Nitric Oxide (NO) Gas Detector, 0 to 20/50/100 ppm

GD200-NO
$846.29
Favorable price Nitric Oxide (NO) Gas Detector for sale. Optional measuring range 0 to 20/50/100/250 ppm, light weight and compact size, portable and convenient to transport. Give sound, light and vibration alarm for NO gas leak, fast response and accurate detection.

Portable Hydrogen Peroxide (H2O2) Gas Detector, 0 to 100/200/500/1000 ppm

GD200-H2O2
$1,312.79
Handheld Hydrogen Peroxide H2O2 gas detector is kind of mini size and high accuracy portable gas detector. Low price portable H2O2 gas detector is with back clip, protected by silicone case, suitable for different kinds of situations. Easy to operate, comprehensive functions, can measure sulfur dioxide gas, measure range from 0 to 100/200/500/1000 ppm.