Handheld Multi-Gas (4-Gas) Detector, CO, H2S, O2, LEL

$449.67
Handheld multi-gas detector provides 4 gases detection, monitoring CO (0-1000ppm), H2S (0-100ppm), O2 (0-30%VOL), EX (0-100%LEL) with high accurate sensors, and give sound, light and vibration alarms, light weight and mini size, portable and easy to carry, long battery life, reliable quality and low price.
SKU: GD500-4GAS
Free Shipping
Delivery date: 6-12 days

Handheld multi gas detector can measure 4 gases (CO, H2S, O2, LEL) at the same time with high accuracy and reliability, min size and high protability, and it is widely used in oil, metallurgy, chemical, medical, agriculture, refinery and other industries.

Features

  • Adopt high precison sensors
  • LCD dot matrix display, , support Chinese and English operation, easy to read
  • Gas unit ppm and mg/m3 can be switched quickly
  • One key to check the battery capacity and voltage.
  • One press to restore factory settings.
  • Alarm with ultra-high buzzer sound and light, high and low alarm values are settable
  • Rechargeable lithium polymer battery with high capacity enables long working time
  • With a alligator clip, easy to carry around
  • Rugged and durable housing, comfortable touch
  • Data storage function: Can record 100,000 data, and historical data can be viewed on the device (optional function).

Specification

ModelGD500-4GAS
Sampling MethodDiffusion
Detection PrincipleElectrochemistry (CO, H2S, O2), Catalytic Combustion (LEL)
GasCarbon Monoxide (CO), Hydrogen Sulfide (H2S), Oxygen (O2), Combustible (LEL)
RangeCO: 0 to 1000ppm, H2S: 0 to 100ppm, O2: 0 to 30% VOL, EX: 0 to 100% LEL
ResolutionCO: 1ppm, H2S: 0.1ppm, O2: 0.1% VOL, EX: 1% LEL
Accuracy≤±3%F.S.
DisplayMonochrome dot matrix 128*128 LCD graphic display
BacklightBacklight time is settable; the backlight will be auto-on when alarming.
Data Logging (Optional Function)Storage capacity of over one hundred thousand sets. Interval times ranging from 10~3600 seconds are settable.
AlarmsSound, light and vibration
Operation LanguageChinese/English
Gas UnitGas units ppm and mg/m3 are switchable
Battery3.7V rechargeable lithium battery with 2300mAh capacity, operating time is about 10-12h
ChargerTravel charger with USB. The typical charge time is 4-6 hours.
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Case MaterialABS+PC
Protection GradeIP65
Operating Temperature-20℃~50℃
Operating Humidity0~90%RH (non-condensing)
Dimension131*85*35mm
Weight240g

Note 1:

  • If you require a gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.


Details

Handheld Multi Gas Detector Details

Tips: What does it mean, the gas units PPM, %LEL, %VOL in multi-gas detector's specification?

1. PPM
PPM refers to parts per million, a unit of gas volume concentration.
For solution: it means that there’s 1/1000 ml solute in the 1L aqueous solution, so its concentration is 1ppm.
For gas: it’s one of representation method of pollutant concentration in the ambient atmosphere (air).
2. %LEL
LEL refers to the lower explosive limit. When the combustible gas reaches 100%LEL, it’s easy to explode, and the explosion occurs as soon as contacting an electric spark. Therefore, 0-100%LEL generally refers to the range of combustible gas measurement. For example, hydrogen: 4%VOL=100%LEL, methane: 5%VOL=100%LEL.
3. %VOL
VOL refers to the volume ratio of target gas in per volume. It’s generally used for high concentration. 1%VOL is equal to 10000PPM, and generally it is for oxygen and combustible gases. For example, how much oxygen in a space.

Operation and Setup of Portable Gas Detectors

This video explains how to operate and set up this portable gas detector.

Product reviews
Useful multi gas detector.
5
Zachary
Avatar
8/28/2018 8:03 PM
Useful multi gas detector. It helps me a lot in my work.
Was this review helpful? Yes No (0/0)
Calibration Password
5
Masoud
Avatar
7/4/2021 3:07 AM
Hi, I needed a password to calibrate the gas meter.
thank you
Was this review helpful? Yes No (0/0)
ATO Responded
For this question, please contact the after sales technical department.
We need to ask some questions about the gas detector.
5
Ran
Avatar
1/26/2022 10:49 PM
Can you add wireless function to your handheld gas detector, so can you get the data directly to my PC?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can add a wireless module to the handheld gas detector, so you can monitor and record data on your PC.
I do have some additional questions though
5
joseph
Avatar
11/23/2023 8:00 PM
I do have some additional questions though. What is the accuracy of all channels? Can the device be delivered with an outlet port such that vent gas can be sent to a safe location? For example, can a ¼” BSP female connection be provided at the outlet port? Regarding the frequency, and correct me if I’m wrong, electrochemical analysis is batch wise, meaning that you can have a maximum amount of analysis cycles per time unit. What would that be for this device?
Was this review helpful? Yes No (0/0)
ATO Responded
1. All channels have an accuracy of 2-3%FS.
2. The instrument has an air outlet and can be connected to a safe location.
3. Sorry, we have Not calculated this analysis cycles.
Multi-Gas detection needs
5
Gunas
Avatar
6/15/2026 9:04 PM
I need a wearable multi-gas detector, powered by a lithium-ion battery, capable of detecting four gases: CO, H2S, and O2, and that can be clipped directly into a pocket, clothing, belt, or backpack.
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, our GD500-4GAS portable gas detector should meet your requirements.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Handheld multi gas detector can measure 4 gases (CO, H2S, O2, LEL) at the same time with high accuracy and reliability, min size and high protability, and it is widely used in oil, metallurgy, chemical, medical, agriculture, refinery and other industries.

Features

  • Adopt high precison sensors
  • LCD dot matrix display, , support Chinese and English operation, easy to read
  • Gas unit ppm and mg/m3 can be switched quickly
  • One key to check the battery capacity and voltage.
  • One press to restore factory settings.
  • Alarm with ultra-high buzzer sound and light, high and low alarm values are settable
  • Rechargeable lithium polymer battery with high capacity enables long working time
  • With a alligator clip, easy to carry around
  • Rugged and durable housing, comfortable touch
  • Data storage function: Can record 100,000 data, and historical data can be viewed on the device (optional function).

Specification

ModelGD500-4GAS
Sampling MethodDiffusion
Detection PrincipleElectrochemistry (CO, H2S, O2), Catalytic Combustion (LEL)
GasCarbon Monoxide (CO), Hydrogen Sulfide (H2S), Oxygen (O2), Combustible (LEL)
RangeCO: 0 to 1000ppm, H2S: 0 to 100ppm, O2: 0 to 30% VOL, EX: 0 to 100% LEL
ResolutionCO: 1ppm, H2S: 0.1ppm, O2: 0.1% VOL, EX: 1% LEL
Accuracy≤±3%F.S.
DisplayMonochrome dot matrix 128*128 LCD graphic display
BacklightBacklight time is settable; the backlight will be auto-on when alarming.
Data Logging (Optional Function)Storage capacity of over one hundred thousand sets. Interval times ranging from 10~3600 seconds are settable.
AlarmsSound, light and vibration
Operation LanguageChinese/English
Gas UnitGas units ppm and mg/m3 are switchable
Battery3.7V rechargeable lithium battery with 2300mAh capacity, operating time is about 10-12h
ChargerTravel charger with USB. The typical charge time is 4-6 hours.
Explosion-proof GradeII 1G Ex da ia IIC T4 Ga
CertificationCE, ATEX (Standard: EN IEC 60079-0:2018, EN 60079-1:2014)
Case MaterialABS+PC
Protection GradeIP65
Operating Temperature-20℃~50℃
Operating Humidity0~90%RH (non-condensing)
Dimension131*85*35mm
Weight240g

Note 1:

  • If you require a gas detector with a measuring range not listed in the table above, please contact us with details about your operating environment. We can help you choose the right detector for your application.

  • We also offer gas detectors for other common gases. Please refer to the ATO Gas Detector Catalog for available gas types and measuring ranges.

Note 2:

Regarding the flow rate for gas detectors, there are 2 types:

  • Pump-Suction Type: Equipped with a built-in pump, with a flow rate of 600 mL/min. (Models: GD200, GD400, GD600)
  • Diffusion Type: Not equipped with a built-in pump, with a flow rate of 300 mL/min. (Models: GD300, GD500, GD800)

If you require a customized flow rate, please let us know your specific requirements. We will evaluate whether customization is possible. A flow rate that is too high or too low can affect measurement accuracy, so we recommend using an appropriate flow rate for your application.

Flow rate only needs to be considered when sampling gas from pipelines. For measuring gas concentrations in normal ambient air, you do not need to consider the flow rate. To measure confined spaces such as pipelines, please get in touch with us and provide the detailed conditions of use.


Details

Handheld Multi Gas Detector Details

Tips: What does it mean, the gas units PPM, %LEL, %VOL in multi-gas detector's specification?

1. PPM
PPM refers to parts per million, a unit of gas volume concentration.
For solution: it means that there’s 1/1000 ml solute in the 1L aqueous solution, so its concentration is 1ppm.
For gas: it’s one of representation method of pollutant concentration in the ambient atmosphere (air).
2. %LEL
LEL refers to the lower explosive limit. When the combustible gas reaches 100%LEL, it’s easy to explode, and the explosion occurs as soon as contacting an electric spark. Therefore, 0-100%LEL generally refers to the range of combustible gas measurement. For example, hydrogen: 4%VOL=100%LEL, methane: 5%VOL=100%LEL.
3. %VOL
VOL refers to the volume ratio of target gas in per volume. It’s generally used for high concentration. 1%VOL is equal to 10000PPM, and generally it is for oxygen and combustible gases. For example, how much oxygen in a space.

Product reviews
Useful multi gas detector.
5
Zachary
Avatar
8/28/2018 8:03 PM
Useful multi gas detector. It helps me a lot in my work.
Was this review helpful? Yes No (0/0)
Calibration Password
5
Masoud
Avatar
7/4/2021 3:07 AM
Hi, I needed a password to calibrate the gas meter.
thank you
Was this review helpful? Yes No (0/0)
ATO Responded
For this question, please contact the after sales technical department.
We need to ask some questions about the gas detector.
5
Ran
Avatar
1/26/2022 10:49 PM
Can you add wireless function to your handheld gas detector, so can you get the data directly to my PC?
Was this review helpful? Yes No (0/0)
ATO Responded
Yes, we can add a wireless module to the handheld gas detector, so you can monitor and record data on your PC.
I do have some additional questions though
5
joseph
Avatar
11/23/2023 8:00 PM
I do have some additional questions though. What is the accuracy of all channels? Can the device be delivered with an outlet port such that vent gas can be sent to a safe location? For example, can a ¼” BSP female connection be provided at the outlet port? Regarding the frequency, and correct me if I’m wrong, electrochemical analysis is batch wise, meaning that you can have a maximum amount of analysis cycles per time unit. What would that be for this device?
Was this review helpful? Yes No (0/0)
ATO Responded
1. All channels have an accuracy of 2-3%FS.
2. The instrument has an air outlet and can be connected to a safe location.
3. Sorry, we have Not calculated this analysis cycles.
Multi-Gas detection needs
5
Gunas
Avatar
6/15/2026 9:04 PM
I need a wearable multi-gas detector, powered by a lithium-ion battery, capable of detecting four gases: CO, H2S, and O2, and that can be clipped directly into a pocket, clothing, belt, or backpack.
Was this review helpful? Yes No (0/0)
ATO Responded
Hello, our GD500-4GAS portable gas detector should meet your requirements.
Only registered users can write reviews