AC/DC High Voltage Sensor 1500V/2000V, Hall Effect, AC/DC 50mA Output

$514.29
Hall effect voltage sensor is a high voltage sensor with a measuring range from AC/DC 1500V to 2000V, output signal AC/DC ±50mA, work temperature -25~+70℃ and protection class IP20. AC/DC Hall effect voltage sensor has the hermetically sealed structure and can be used in harsh conditions.
SKU: ATO-VOS-ACDC2000
*
*
*
Free Shipping
Delivery date: 8-12 days

AC/DC Hall effect voltage sensor has measuring range of AC/DC 1500V to 2000V.

Specification:

ModelATO-WBV023YB08-DDATO-WBV023YB08-SS
Shipping weight1.5kg
Measuring range of input voltage *AC/DC 0-1500V ~ 0-2000V
Working rangeAC/DC 0-2000V ~ 0-3000V
Turns ratio of coil *10000:3000, 10000:2000
Coil impedance1.8kΩ+R1 (primary external resistance)
Zero current offsetWhen primary voltage VN=0, maximum value: ±0.3mA
Output signal *DC 50mAAC/DC ±50mA
Power supply *DC 24VDC ±12V, ±15V
Accuracy1.0%F.S.
Linearity≤0.1%
Load impedance150Ω
Response time≤200μs
Temperature drift of current offset<±0.3mA, maximum value: ±0.5mA
Power consumption current10mA+IM (measuring current)
Isolation featuresIsolation between input, output and power supplyIsolation between input and output, output terminals provides power supply
Isolation voltageBetween the primary and secondary circuit: RMS 10kV, 50Hz, 1min
Work temperature-25~+70℃
Storage temperature-40~+85℃
Frequency bandDC ~5kHz
Mean time between failures>50000h
Housing materialFire-retardant ABS
WiringTerminal connection
InstallationScrew fixation

Hall effect voltage sensor AC/DC 1500V to 2000V dimensional drawing (unit: mm):
AC/DC Hall effect high voltage sensor 1500V/2000V dimension
Hall effect voltage sensor AC/DC 1500V to 2000V wiring diagram:
AC/DC Hall effect high voltage sensor 1500V/2000V wiring
Tips: What is the working principle of Hall effect voltage sensor?

The Hall effect voltage sensor uses Hall effect to pass the primary voltage through an external or built-in resistor to limit the current to 10mA. After this current passes through multiple turns of winding, the magnetic field, which is generated through a magnetic material, will be detected by the Hall element in the air gap, and the corresponding electromotive force is induced. The electromotive force is adjusted by the circuit and fed back to the compensation coil to compensate. The magnetic flux generated by the compensation coil and the primary current (The measured voltage is generated by current limiting resistor.) the generated magnetic flux is equal in magnitude and opposite in direction, thus keeping the magnetic flux in the magnetic core to be zero. In fact, the Hall voltage sensor uses the same technology as the magnetic balance closed-loop Hall effect current sensor, that is, the zero flux Hall current sensor.

Product reviews
I thought of your voltage sensor
5
Meghanb
Avatar
9/22/2021 8:38 PM
I have come up with your product below:
Voltage Sensor
ATO-VOS-DC1000
Though, I have 2 questions:
1) I see there are several inputs for voltage from 0V – 1000V. My first question is how can I select a range of fe150V?
In such case, what will the accuracy at low voltages fe 4V (I need accuracy of 2 decimals)?
Is there an option to switch between 2 ranges in one single sensor?
2) If I adjust the output range to 0-10V (this is my acceptable PLC input), what will be the output in case of reverse polarity connection? I really want to avoid a negative signal on my PLC input.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Select required measuring range as you like from the pull down menu seen on the web site, and accuracy is: 0.2%F.S.
No option is to switch between 2 ranges in one single sensor.
2. This is a DC voltage sensor, so the input voltage cannot reverse polarity connection, otherwise it may cause damage to the sensor.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

AC/DC Hall effect voltage sensor has measuring range of AC/DC 1500V to 2000V.

Specification:

ModelATO-WBV023YB08-DDATO-WBV023YB08-SS
Shipping weight1.5kg
Measuring range of input voltage *AC/DC 0-1500V ~ 0-2000V
Working rangeAC/DC 0-2000V ~ 0-3000V
Turns ratio of coil *10000:3000, 10000:2000
Coil impedance1.8kΩ+R1 (primary external resistance)
Zero current offsetWhen primary voltage VN=0, maximum value: ±0.3mA
Output signal *DC 50mAAC/DC ±50mA
Power supply *DC 24VDC ±12V, ±15V
Accuracy1.0%F.S.
Linearity≤0.1%
Load impedance150Ω
Response time≤200μs
Temperature drift of current offset<±0.3mA, maximum value: ±0.5mA
Power consumption current10mA+IM (measuring current)
Isolation featuresIsolation between input, output and power supplyIsolation between input and output, output terminals provides power supply
Isolation voltageBetween the primary and secondary circuit: RMS 10kV, 50Hz, 1min
Work temperature-25~+70℃
Storage temperature-40~+85℃
Frequency bandDC ~5kHz
Mean time between failures>50000h
Housing materialFire-retardant ABS
WiringTerminal connection
InstallationScrew fixation

Hall effect voltage sensor AC/DC 1500V to 2000V dimensional drawing (unit: mm):
AC/DC Hall effect high voltage sensor 1500V/2000V dimension
Hall effect voltage sensor AC/DC 1500V to 2000V wiring diagram:
AC/DC Hall effect high voltage sensor 1500V/2000V wiring
Tips: What is the working principle of Hall effect voltage sensor?

The Hall effect voltage sensor uses Hall effect to pass the primary voltage through an external or built-in resistor to limit the current to 10mA. After this current passes through multiple turns of winding, the magnetic field, which is generated through a magnetic material, will be detected by the Hall element in the air gap, and the corresponding electromotive force is induced. The electromotive force is adjusted by the circuit and fed back to the compensation coil to compensate. The magnetic flux generated by the compensation coil and the primary current (The measured voltage is generated by current limiting resistor.) the generated magnetic flux is equal in magnitude and opposite in direction, thus keeping the magnetic flux in the magnetic core to be zero. In fact, the Hall voltage sensor uses the same technology as the magnetic balance closed-loop Hall effect current sensor, that is, the zero flux Hall current sensor.

Product reviews
I thought of your voltage sensor
5
Meghanb
Avatar
9/22/2021 8:38 PM
I have come up with your product below:
Voltage Sensor
ATO-VOS-DC1000
Though, I have 2 questions:
1) I see there are several inputs for voltage from 0V – 1000V. My first question is how can I select a range of fe150V?
In such case, what will the accuracy at low voltages fe 4V (I need accuracy of 2 decimals)?
Is there an option to switch between 2 ranges in one single sensor?
2) If I adjust the output range to 0-10V (this is my acceptable PLC input), what will be the output in case of reverse polarity connection? I really want to avoid a negative signal on my PLC input.
Was this review helpful? Yes No (0/0)
ATO Responded
1. Select required measuring range as you like from the pull down menu seen on the web site, and accuracy is: 0.2%F.S.
No option is to switch between 2 ranges in one single sensor.
2. This is a DC voltage sensor, so the input voltage cannot reverse polarity connection, otherwise it may cause damage to the sensor.
Only registered users can write reviews
Customers who bought this item also bought

Hall Effect Current Sensor 50A/100A/300A/800A/1200A to 1500A

ATO-CUS-ACDC1500
$93.23
Hall effect current sensors are AC/DC universal current sensors, with split-core structure, 5us fast response time, 1.0%FS accuracy, 0-5V/ 0-±5VDC output signal, ±15V power supply, fixed installation. Open loop current sensors are widely used for AC and DC current monitoring, system signal acquisition and feedback control.

Hall Effect Current Sensor 400A/2000A/3000A/5000A/8000A to 20000A

ATO-CUS-ACDC20000
$122.98
Hall effect current sensors are AC/DC universal current sensors, with non-invasive structure, 5us fast response time, 1.0%FS accuracy, 0-5V output signal, ±15V power supply, measuring range can be 0-400A ~ 0-20000A or even higher current. Open loop current sensors are widely used for AC and DC high current detection, such as the high frequency switching power supply and solar power supply management system.

AC Voltage Sensor, Range 10V to 1000V, Power Supply DC 12V/24V/36V

ATO-VOS-AC1000
$174.92
AC voltage sensors have voltage measuring range from 10V/50V/100V/200V/500V/800V to 1000V, supply voltage DC 9V~36V, work temperature -25~+70℃, frequency range 25Hz ~ 3kHz and good EMC design. Voltage sensors have two installation methods, DIN rail installation and M3 screw fixation.

Isolated DC Voltage Sensor 10mV to 1000V, Power Supply DC 12V/24V

ATO-VOS-DC1000
$141.96
DC voltage sensor uses modulation and demodulation technology to achieve input/output/power supply isolation. Isolated voltage transducer has measuring range from DC 10mV/50mV/75mV/5V/150V/300V/500V to 1000V, supply voltage DC 12V/24V, accuracy 0.2%FS, output signal 0-5V/0-10V/0-20mA/4-20mA and strong anti-interference capability. DC voltage sensor is widely used for voltage isolated measuring and control, such as electric power, remote monitoring, medical equipment, etc.