Insertion Electromagnetic Water Flow Meter, DN100-DN3000

$2,257.41
Reasonable price and high quality insertion type magnetic flow meter for sale online. The medium of insertion magnetic flowmeter is water. Working temperature of insertion electromagnetic flow meter between -20°C and 70°C. It often used in petrochemical, electric power, metallurgy and textile.
SKU: ATO-FLOW-IEFM
*
*
*
*
Free Shipping
Delivery date: 6-12 days

The insertion magnetic water flow meter is a type of flowmeter divided by structure. When a conductive medium is flowing through, an induced voltage is generated.

Specification

ModelATO-LDGC-SUP-L
Port SizeDN100-3000 mm (port size more than DN1000 please contact us)
Working Pressure1.6 Mpa
Working Temperature≤70°C
Upper Limit Range1-10 m/s
Accuracy of Measurement±2.5%
Conductivity≥50%
Mediumwater
Electrode Material304, 304L, 316, 316L, Hastelloy alloy, titanium
Converter Output4-20 mA output
Frequency Outputpluse output
Communication OutputRS485
Power Supply24V DC, 220V AC
Maximum Distance≤50m
CableRVVP double core shielded cable or STT3200 four core three shield cable
Compact TypeIP65 / IP68
Buried DepthNot deeper than 5 meters
Repetitiveness0.0016
Maxium Measurement Error±0.1°C


Features

  • Wide Compatibility: Suitable for environmental protection sewage/municipal water supply/agricultural irrigation/water conservancy and other fields, not affected by viscosity, temperature, pressure and so on.
  • Convenient Installation: Flow meter installation process without disconnection, maintenance, easy installation.
  • 304 Stainless Steel Material: The flow meter is made of corrosion-resistant stainless steel material is easy to maintain and has a long service life.
  • Bidirectional Flow Measurement: Adopting bi-directional measurement system, easy to set the direction of flow measurement, making the measurement more convenient.

Dimension (unit: mm)

Insertion electromagnetic flow meter dimension

DNabfDDon*APressure Resistance
1002504102151808*181.6 MPa
1252504402452108*18
1503004692802408*23
20035052233529512*23
25045082440535512*25
30050062444040012*231 MPa
350550102950046016*23
40060073756551516*25
45060078661556520*25
50060083967062020*25
60060094478072520*30
700700105289584024*30
8008001164101595024*33
90090012641115105028*33
1000100013741230116028*36
1200120015891405134032*330.6 MPa


Structure

Structure insertion electromagnetic flow meter

Tips: Why should maintain insertion electromagnetic flow meter?

The insertion electromagnetic flow meter is simple to operate, but long-term use will still make the electrode stain or damage, so to ensure the accuracy of measurement, regular maintenance of the insertion electromagnetic flowmeter is very necessary. For the plug-in electromagnetic meteor meter, each maintenance must be closed system, the liquid in the pipeline is emptied, can be disassembled.

Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The insertion magnetic water flow meter is a type of flowmeter divided by structure. When a conductive medium is flowing through, an induced voltage is generated.

Specification

ModelATO-LDGC-SUP-L
Port SizeDN100-3000 mm (port size more than DN1000 please contact us)
Working Pressure1.6 Mpa
Working Temperature≤70°C
Upper Limit Range1-10 m/s
Accuracy of Measurement±2.5%
Conductivity≥50%
Mediumwater
Electrode Material304, 304L, 316, 316L, Hastelloy alloy, titanium
Converter Output4-20 mA output
Frequency Outputpluse output
Communication OutputRS485
Power Supply24V DC, 220V AC
Maximum Distance≤50m
CableRVVP double core shielded cable or STT3200 four core three shield cable
Compact TypeIP65 / IP68
Buried DepthNot deeper than 5 meters
Repetitiveness0.0016
Maxium Measurement Error±0.1°C


Features

  • Wide Compatibility: Suitable for environmental protection sewage/municipal water supply/agricultural irrigation/water conservancy and other fields, not affected by viscosity, temperature, pressure and so on.
  • Convenient Installation: Flow meter installation process without disconnection, maintenance, easy installation.
  • 304 Stainless Steel Material: The flow meter is made of corrosion-resistant stainless steel material is easy to maintain and has a long service life.
  • Bidirectional Flow Measurement: Adopting bi-directional measurement system, easy to set the direction of flow measurement, making the measurement more convenient.

Dimension (unit: mm)

Insertion electromagnetic flow meter dimension

DNabfDDon*APressure Resistance
1002504102151808*181.6 MPa
1252504402452108*18
1503004692802408*23
20035052233529512*23
25045082440535512*25
30050062444040012*231 MPa
350550102950046016*23
40060073756551516*25
45060078661556520*25
50060083967062020*25
60060094478072520*30
700700105289584024*30
8008001164101595024*33
90090012641115105028*33
1000100013741230116028*36
1200120015891405134032*330.6 MPa


Structure

Structure insertion electromagnetic flow meter

Tips: Why should maintain insertion electromagnetic flow meter?

The insertion electromagnetic flow meter is simple to operate, but long-term use will still make the electrode stain or damage, so to ensure the accuracy of measurement, regular maintenance of the insertion electromagnetic flowmeter is very necessary. For the plug-in electromagnetic meteor meter, each maintenance must be closed system, the liquid in the pipeline is emptied, can be disassembled.

Only registered users can write reviews
Customers who bought this item also bought

Custom Order

ATO-CUSTOM
Pay for custom orders, or extra amount of existing orders.
Indicate the item specification you pay for, and specify PI / PO number if you have.

Float Switch Level Sensor, Stainless Steel/ Plastic

ATO-ES12010-2A1
$61.43
Stainless steel and plastic float switch level sensor is composed magnetic spring switch and floating ball to detecting the position of the liquid level. Vertical mounted, contact power rating 50W.

Ultrasonic Tank Level Sensor, Output 4-20mA/1-5V/RS485, 0-40M

ATO-LEVS-U40M
$475.98
Ultrasonic level sensor has high accuracy 0.3%FS and measuring range 0-5m, 0-10m, 0-15m to 0-40m. It also adopts integrated structure and mainly consists of OLED display, waterproof connectors and ultrasonic probe. Ultrasonic tank level sensor using advanced non-contact ultrasonic measurement technology can be used for liquid/solid/powder level of tapered/spherical tank, tapered feed outlet tank, sewage tank, river, lake, etc. It has optional output signal 4-20mA, RS485, HART, 2 relays or 3 NPN, optional power supply DC 12-16V, DC 24-28V, AC 220V or built-in battery.

10 hp (7.5 kW) Soft starter, 15 A, 3ph 220v/400v/480v

GS-7d5
$352.31
Favorable price 10 hp soft starter, 7.5 kW 3 phase 220v, 400v, 480v electric motor soft starts, make motor in soft start & soft stop, direct sale from manufacturer.

100W Brushless DC Motor, 12V/24V, 0.32 Nm

ATO-BLDC-100R3
$178.58
100W BLDC motor for sales at affordable price. 3 phase electric brushless motor with 3000 rpm rated speed, 0.32 Nm holding torque and peak torque up to 0.96 Nm. Combines with BLDC controller/ gearbox providing higher torque at 12V or 24V DC.