Thermal Gas Mass Flow Meter, DN65-DN1000

$2,034.61
Thermal gas mass flow meter with digital design at affordable price for sale online. The response speed of gas mass flow meter is 1s. Structure form of this flow meter is plug-in type. Thermal gas mass flowmeter widely used in cement plant, glass factory and water treatment.
SKU: ATO-FLOW-TGFM
*
*
*
*
Free Shipping
Delivery date: 6-12 days

The thermal gas mass flow meter is an instrument to measure the gas flow by the principle of thermal diffusion. Convenient installation and low maintenance cost. Thermal gas mass flow meter adopts a variety of signals to achieve automation.

Specification

ModelATO-SUP-MF
Structural Formplug-in type
Measuring Mediumcommon steady state gas
Pipe Diameter RangeDN65-DN1000
Velocity Range0.1-100 Nm/s
Accuracy±2.5%
Working TemperatureSensor: -40°C ~ 300°C; Converter: -20°C ~ 45°C
Pressure≤2.5 MPa
Power SupplyAC 220V; DC 24V
Response Speed1s
Output Signal2-wire 4-20mA with Display; 3-wire 4-20mA with Display; 2-wire 4-20mA+Hart with Display; RS485+Pulse with Display
Alarm1-2 normally open contacts
Displayliquid crystal display
Sensor Materialstainless steel
Level of ProtectionIP65


Features

  • Easy to install and maintain.
  • Good seismic performance and long service life.
  • No temperature and pressure compensation is required for gas flow measurement.
  • RS485 communication or HART communication, can achieve factory automation, integration.

Dimension (unit: mm)

Thermal gas mass flow meter size

Port SizeAB
DN65-DN200431mm250mm
DN200-DN500551mm370mm
DN500-DN1000811mm630mm


Thermal Gas Mass Flow Meter Wiring Instruction

Thermal gas mass flow meter wiring instruction

Note: (This is demonstrated by the accumulator, PLC system with (4~20)mA receiving function or other devices can be wired in this way.)

Installation Requires

Installation of the flowmeter should be away from elbows, obstacles, reducers and valves to ensure a stable flow field, one side of the upper limit requires a longer straight pipe, the front straight pipe length is greater than 10D, after the straight section is greater than 5D. the following chart for the field often encountered in several cases of the required length of the straight pipe section:

Thermal gas mass flow meter installation require

Pipe Installation TypeNo.Front Straight Pipe SectionBack Straight Pipe Section
Horizontal Pipe110D5D
Bend210D5D
Expanded Pipe315D5D
Downstream of Gate420D5D
Shrinkage Pipe520D5D
Pump Downstream630D5D

Installation Precautions

  1. If the thermal gas mass flow meter is installed outdoors, it should be covered with a meter sunshade to avoid sunshine and rain.
  2. Prohibit installation in strong vibration occasions.
  3. Prohibit exposure to environments containing large amounts of corrosive gases.
  4. Do not share the power supply with inverters, welding machines and other equipment that pollute the power supply. If necessary, install purified power supply for the converter.

Application

Thermal gas mass flow meter application

Tips: Advantages of Thermal Gas Mass Flow Meter

  • It is convenient and accurate to measure gas flow without temperature and pressure compensation.
  • Compared with the general measuring equipment, the gas flowmeter has good seismic performance and long service life. The sensor has no moving parts and pressure sensing parts, and is not affected by vibration on the measurement accuracy.
  • Easy installation and maintenance. If site conditions permit, it can be installed and maintained without stopping production.
  • Digital design. Overall digital circuit measurement, accurate measurement, easy to maintain.
Product reviews
Looking for suitable flow meters
5
Enliss
Avatar
3/25/2026 12:06 AM
I am looking for the following flow meters for air at 60 degrees Celsius: 0.8 m³/min, 1.5 m³/min, 2 m³/min, and 3 m³/min. What is the maximum capacity?
Was this review helpful? Yes No (0/0)
ATO Responded
1. For air at 60 degrees Celsius 0.8 m³/min, you can use our micro gas mass flow meter, 100-5000 sccm/1-100 SLPM, SKU: ATO-FLOW-MFM, 0-800 SPL/Min, NPT 3/4''-male, see on: https://www.ato.com/micro-gas-mass-flow-meter
2. For larger flow rates of 1.5~3 m³/min, we recommend our thermal gas mass flow meter, DN65-DN1000, SKU: ATO-FLOW-TGFM.
Reliable and accurate gas flow meter
5
Finn
Avatar
6/30/2026 7:24 PM
Using this thermal gas mass flow meter in our plant has improved process monitoring. The readings are repeatable, the LCD is easy to read, and setup was straightforward. Very satisfied with the overall performance.
Was this review helpful? Yes No (0/0)
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

The thermal gas mass flow meter is an instrument to measure the gas flow by the principle of thermal diffusion. Convenient installation and low maintenance cost. Thermal gas mass flow meter adopts a variety of signals to achieve automation.

Specification

ModelATO-SUP-MF
Structural Formplug-in type
Measuring Mediumcommon steady state gas
Pipe Diameter RangeDN65-DN1000
Velocity Range0.1-100 Nm/s
Accuracy±2.5%
Working TemperatureSensor: -40°C ~ 300°C; Converter: -20°C ~ 45°C
Pressure≤2.5 MPa
Power SupplyAC 220V; DC 24V
Response Speed1s
Output Signal2-wire 4-20mA with Display; 3-wire 4-20mA with Display; 2-wire 4-20mA+Hart with Display; RS485+Pulse with Display
Alarm1-2 normally open contacts
Displayliquid crystal display
Sensor Materialstainless steel
Level of ProtectionIP65


Features

  • Easy to install and maintain.
  • Good seismic performance and long service life.
  • No temperature and pressure compensation is required for gas flow measurement.
  • RS485 communication or HART communication, can achieve factory automation, integration.

Dimension (unit: mm)

Thermal gas mass flow meter size

Port SizeAB
DN65-DN200431mm250mm
DN200-DN500551mm370mm
DN500-DN1000811mm630mm


Thermal Gas Mass Flow Meter Wiring Instruction

Thermal gas mass flow meter wiring instruction

Note: (This is demonstrated by the accumulator, PLC system with (4~20)mA receiving function or other devices can be wired in this way.)

Installation Requires

Installation of the flowmeter should be away from elbows, obstacles, reducers and valves to ensure a stable flow field, one side of the upper limit requires a longer straight pipe, the front straight pipe length is greater than 10D, after the straight section is greater than 5D. the following chart for the field often encountered in several cases of the required length of the straight pipe section:

Thermal gas mass flow meter installation require

Pipe Installation TypeNo.Front Straight Pipe SectionBack Straight Pipe Section
Horizontal Pipe110D5D
Bend210D5D
Expanded Pipe315D5D
Downstream of Gate420D5D
Shrinkage Pipe520D5D
Pump Downstream630D5D

Installation Precautions

  1. If the thermal gas mass flow meter is installed outdoors, it should be covered with a meter sunshade to avoid sunshine and rain.
  2. Prohibit installation in strong vibration occasions.
  3. Prohibit exposure to environments containing large amounts of corrosive gases.
  4. Do not share the power supply with inverters, welding machines and other equipment that pollute the power supply. If necessary, install purified power supply for the converter.

Application

Thermal gas mass flow meter application

Tips: Advantages of Thermal Gas Mass Flow Meter

  • It is convenient and accurate to measure gas flow without temperature and pressure compensation.
  • Compared with the general measuring equipment, the gas flowmeter has good seismic performance and long service life. The sensor has no moving parts and pressure sensing parts, and is not affected by vibration on the measurement accuracy.
  • Easy installation and maintenance. If site conditions permit, it can be installed and maintained without stopping production.
  • Digital design. Overall digital circuit measurement, accurate measurement, easy to maintain.
Product reviews
Looking for suitable flow meters
5
Enliss
Avatar
3/25/2026 12:06 AM
I am looking for the following flow meters for air at 60 degrees Celsius: 0.8 m³/min, 1.5 m³/min, 2 m³/min, and 3 m³/min. What is the maximum capacity?
Was this review helpful? Yes No (0/0)
ATO Responded
1. For air at 60 degrees Celsius 0.8 m³/min, you can use our micro gas mass flow meter, 100-5000 sccm/1-100 SLPM, SKU: ATO-FLOW-MFM, 0-800 SPL/Min, NPT 3/4''-male, see on: https://www.ato.com/micro-gas-mass-flow-meter
2. For larger flow rates of 1.5~3 m³/min, we recommend our thermal gas mass flow meter, DN65-DN1000, SKU: ATO-FLOW-TGFM.
Reliable and accurate gas flow meter
5
Finn
Avatar
6/30/2026 7:24 PM
Using this thermal gas mass flow meter in our plant has improved process monitoring. The readings are repeatable, the LCD is easy to read, and setup was straightforward. Very satisfied with the overall performance.
Was this review helpful? Yes No (0/0)
Only registered users can write reviews