Specification

ModelATO-LC-E
Displaypointer single time, cumulative intelligent liquid crystal display
Output Signaloutput of pulse, 4-20 mA output, RS485
Return to Zerooptional
Measurement Mediumdiesel oil, gasoline
Port SizeDN10-200
Measurement Range0.04-340 m3/h
Accuracy0.5 grade (default), 0.2 grade (contact us)
Medium Temperature20°C ~ 100°C
Temperature Range

Conventional Pointer Type: -20℃~+80℃; High Temperature Pointer Type: -20℃~+200℃
Conventional Liquid Crystal Type: -20℃~+60℃; High Temperature Liquid Crystal Type: -20℃~+150℃
Conventional pointer (default), please get in touch with us for other options.

Working Pressure6.4 Mpa
Working Temperature-20°C ~ 200°C
Power SupplyDC 12V ~ DC 24V
Protection LevelIP65
Explosion Proof GradeCT6
Materialcast iron (default), cast steel or stainless steel (contact us)


Features

  • It is simple to install and easy to maintain.
  • The scene showed zero back. The pointer indicates the flow, and the double value shows the single and cumulative flow respectively.
  • The workmanship is exquisite. Multi-process construction, strong pressure resistance.

Dimension (unit: mm)

Oval gear flow meter dimension

DNLHBCIDD1Nφ
10150100210120459060414
15170118226136489565414
202001502381485310575414
252601802461566011585414
402451802711817714510418
100515418458278131215180818
150540515557377210280240823
2006506506244442473352951223


Detail

Ova gear flow meter detail

  1. Scale Dial: Lightweight volumetric flowmeter with pointer display, word wheel totalizing device, and return-to-zero device.
  2. Gear Rotor: The elliptical gear keeps rotating and discharging the liquid to get the total amount of liquid and instantaneous flow rate.
  3. Flange Connection: It can make the product get better and more convenient maintenance in the later stage, and play the role of sewage, balance pressure.

Installation Diagram

Ova gear flow meter installation diagram

Installation Precautions

  • Horizontal Installation
  1. Install the oval gear in a horizontal position as much as possible.
  2. Install the meter at the output end of the pump body.
  3. Install a filter in front of the meter to stop the passage of 0.2 mm microliter and prevent the meter from clogging.
  • Vertical Installation
  1. It is advisable to install a back valve in front of the meter so that only one-way flow is possible in the pipeline to prevent counter loss.
  2. Installation can be from top to bottom left to right.

Application

Ova gear flow meter application

Tips: Oval Gear Flow Meter Using Tips

  • Clean the line. The new pipeline should be cleaned before operation, and often then washed with solid flow to remove residual welding chips, dirt, etc. At this time, the front and rear stop valves of the instrument should be closed to let the liquid flow through the bypass pipe. If there is no bypass pipe, install short pipe instead.
  • Exhaust the gas. Usually after the solid liquid sweeps, there is still a lot of air left in the pipeline. With the pressure operation, the air flows through the positive displacement flowmeter at a higher velocity, and the movable measuring element may run too fast, damaging the shaft and bearing.
Write your review
  • Only registered users can write reviews
*
*
  • Bad
  • Excellent
*
*
*
*

Note*: This flow meter is not equipped with explosion-proof certification. Caution is required when using it with flammable media.

Oval gear flowmeter belongs to a positive displacement flowmeter, in the flow meter is a class of high accuracy. The flow meter uses precision gears to make accurate measurements.

Specification

ModelATO-LC-E
Displaypointer single time, cumulative intelligent liquid crystal display
Output Signaloutput of pulse, 4-20 mA output, RS485
Return to Zerooptional
Measurement Mediumdiesel oil, gasoline
Port SizeDN10-200
Measurement Range0.04-340 m3/h
Accuracy0.5 grade (default), 0.2 grade (contact us)
Medium Temperature20°C ~ 100°C
Temperature Range

Conventional Pointer Type: -20℃~+80℃; High Temperature Pointer Type: -20℃~+200℃
Conventional Liquid Crystal Type: -20℃~+60℃; High Temperature Liquid Crystal Type: -20℃~+150℃
Conventional pointer (default), please get in touch with us for other options.

Working Pressure6.4 Mpa
Working Temperature-20°C ~ 200°C
Power SupplyDC 12V ~ DC 24V
Protection LevelIP65
Explosion Proof GradeCT6
Materialcast iron (default), cast steel or stainless steel (contact us)


Features

  • It is simple to install and easy to maintain.
  • The scene showed zero back. The pointer indicates the flow, and the double value shows the single and cumulative flow respectively.
  • The workmanship is exquisite. Multi-process construction, strong pressure resistance.

Dimension (unit: mm)

Oval gear flow meter dimension

DNLHBCIDD1Nφ
10150100210120459060414
15170118226136489565414
202001502381485310575414
252601802461566011585414
402451802711817714510418
100515418458278131215180818
150540515557377210280240823
2006506506244442473352951223


Detail

Ova gear flow meter detail

  1. Scale Dial: Lightweight volumetric flowmeter with pointer display, word wheel totalizing device, and return-to-zero device.
  2. Gear Rotor: The elliptical gear keeps rotating and discharging the liquid to get the total amount of liquid and instantaneous flow rate.
  3. Flange Connection: It can make the product get better and more convenient maintenance in the later stage, and play the role of sewage, balance pressure.

Installation Diagram

Ova gear flow meter installation diagram

Installation Precautions

  • Horizontal Installation
  1. Install the oval gear in a horizontal position as much as possible.
  2. Install the meter at the output end of the pump body.
  3. Install a filter in front of the meter to stop the passage of 0.2 mm microliter and prevent the meter from clogging.
  • Vertical Installation
  1. It is advisable to install a back valve in front of the meter so that only one-way flow is possible in the pipeline to prevent counter loss.
  2. Installation can be from top to bottom left to right.

Application

Ova gear flow meter application

Tips: Oval Gear Flow Meter Using Tips

  • Clean the line. The new pipeline should be cleaned before operation, and often then washed with solid flow to remove residual welding chips, dirt, etc. At this time, the front and rear stop valves of the instrument should be closed to let the liquid flow through the bypass pipe. If there is no bypass pipe, install short pipe instead.
  • Exhaust the gas. Usually after the solid liquid sweeps, there is still a lot of air left in the pipeline. With the pressure operation, the air flows through the positive displacement flowmeter at a higher velocity, and the movable measuring element may run too fast, damaging the shaft and bearing.
Only registered users can write reviews